Type LDU 68.1/68.2/69.1/78.

1 Load Cell Digitizing Unit

Product Description The Load Cell Digitizing Units LDU 68.1 / 68.2 / 69.1 / 78.1 are accurate, veritable A/D convertors for static and / or dynamic weighing applications. LDU 68.1 / 69.1 / 79.1 are approved by Weights & Measures Authorities for use in Accuracy Class III applications with up to 10 000 increments (e) according to OIML R76; details see specs. Communication via serial interface RS422/RS485, making it easy to connect to PC, PLC and other devices. Standard weighing functions are available. Special commands e.g. in LDU 78.1 are implemented for applications like lling / dosing / check weighing etc. Software calibration and set up. The LDU 69.1 covers features like mV/V calibration, high resolution, 7 point linearization, synchronization with other LDU 69.1. Therefore it is the ideal instrument for high precision high resolution measurements in multi channel applications. The LDU family will be supported by the DOP software (easy set up, recording dynamic graphs, etc.) and the AppMon software for long time multi channel data records. Both software packages require Windows 2000/XP.

Key Features Easy converting analogue load cells to digital Internal resolution up to 1 050 000 counts EU Type approved Digital lter, programmable Special commands for diff. applications Linearity better than 0.002 % 6 wire load cell connection Network function by RS422/RS485 Power supply 12 24 V DC Available Accessories Adaptor board(s) with screw terminals for mounting on rail 8 channel adaptor board with screw terminals for mounting on rail Setup software running under MS Windows

E146-Rev0-E-1(2) WWW.FLINTEC.COM

Specifications
Type Accuracy Class EU Type approved according OIML R76 Linearity Excitation: load cells 250-2000 , 6 wire technique Analogue input range Min. input per verication scale interval (vsi) non approved / approved Resolution internal / external (counts) A/D converter Conversion rate in meas. per second int./ext. Digital lter (Hz) Filter Mode Calibration mV/V calibration / linearization Computer interface Weighing functions Inputs opto-isol., 10 30 V DC max. 3 mA Outputs, OC, < 30 V DC, 200 mA Temperature effects on zero typ. / max. Temperature effects on span typ. / max. Temperature range Enclosure Dimensions Power supply Options EMC LDU 68.1 III 5000 d LDU 69.1 LDU 78.1 III III 10000 d 5000 d < 0.002 % FS < 0.001 % FS < 0.002 % FS 5 V DC 5 V AC 5 V DC 2.2 mV/V (bipolar, for weighing applications and force measurements) 0.1 V / n.a. 0.02 V / 0.1 V 0.05 V / 0.7 V LDU 68.2 n.a. n.a.

0.1 V / 0.7 V

/C) (/C)

1 050 000 / 999 999 260 000 / 199 999 20-Bit 18-Bit 172 / up to 172 2400 / up to 600 0.2 - 3 / 6 steps 0.25 - 18 / 2,5 - 19,7 Bessel / Gauss / Bessel FIR / IIR | 8 steps each Butterworth software calibration and set up n.a. 7 points n.a. RS485 or RS422, full duplex, 9600 115200 Baud; bus capability up to 32 devices (RS485) zero, gross, tare, net, lter etc. 2 n.a. 2 2 n.a. 2 5 ppm / <10 ppm 15 ppm / <30 ppm 1 ppm / <2 ppm 5 ppm /<10 ppm 3 ppm / <5 ppm 8 ppm / <15 ppm 1 ppm / <2 ppm 4 ppm / <8 ppm 10 C to +50 C (compensated); 20 C to +60 C (storage) tinned steel enclosure, protection IP20, special housing IP65 on request 82 x 31 x 6 mm, weight approx. 30 g; with adaptor board 99 x 41 x 12 mm, approx. 50 g 12 24 V DC 10 %, < 60 mA, not galvanically isolated adaptor board UA 73.2 (RS485 / RS422) or UA 77.1 (RS422 to RS232) CE 73/23/EEC, 93/98/EEC and 89/336/EEC

130 000 / 99 999 17-Bit 90 / up to 90 0.02 - 5 / 8 steps

System Configuration (example LDU 78.1)


P1

Load cells; 6-wire connection

R1 Zero Adj.

R3 R4

0 Gnd 1+ Exc 2+ Sen 3+ Sig 4 Sig 5 Sen 6 Exc 7 Gnd 8 NC 9 NC


P2 Span Adj. R2

Load cell Digitizing Unit

LDU 78.1
nmax = 5000 Temp. -15C/+50C Certificate no. DK 0199 - R76 - 02.02

www.flintec.com
Made in EU

10 Rx 11 Tx 12 + Tx 13 0 In 14 0 Out 15 1 In 16 1 Out 17 + 18 Gnd19


F1
Buss 1/4A

+ Rx

PLC system

RS422/485-interface for PLC/PC-connection


Silo Nr.: 1 Netto : 17285 kg Tara : 1458 kg

LDU 78.1 plugged on adaptor board (optional): UA73.2 with RS485 / RS422 output UA77.1 with converter RS422 to RS232 (Outline dimensions 99 x 41 x 12)

Power supply 12 ... 24 V DC max. 60 mA

2 inputs 2 outputs

Dimensions (example LDU 78.1)


82 3.8
P1

31

0 Gnd 1+ Exc 2+ Sen 3+ Sig 4 Sig 5 Sen 6 Exc 7 Gnd 8 NC 9 NC

Load cell Digitizing Unit

R1

LDU 78.1
nmax = 5000 Temp. -15C/+50C Certificate no. DK 0199 - R76 - 02.02

+ Rx

R3

www.flintec.com

10 Rx 11 Tx 12 + Tx 13 0 In 14 0 Out 15 1 In 16 1 Out 17 + 18 Gnd19