You are on page 1of 14

Greenship Rating Tools : The Challenge & Barriers for Building Energy Efficiency in Indonesia

22 June 2011 Ir. Rana Yusuf Nasir Director of Rating & Technology Green Building Council Indonesia

POLICY DIRECTION
ENERGY SUPPLY SIDE MANAGEMENT SUPPLY Fossil energy (subsidized) RE as alternative energy DEMAND Unefficient sectoral energy demand : House hold Transportation Industry Commercial
4300 BOE

ENERGY DEMAND SIDE MANAGEMENT DEMAND Efficient sectoral energy demand : House hold Transportation Industry Commercial SUPPLY
(DIVERSIFICATION)

Fossil energy as secondary energy sources

3,1%
3200 Mil.BOE 2852 Mil.BOE

34.6%

ENERGY CONSERVATION (33,85%)


25 % NRE

17% 20,6%
1131,3 Mil.BOE

33% 22 % Coal

ENERGY DIVERSIFICATION

NRE Coal

4,4 % 30,7 % 21 %

30% 41.7% 20%

Gas

23 % Gas 30 % Oil

Oil

43,9%

2010*

2015

2020 2025 2

Source: *Projection 2010, DEN 2010-2025, **BAU Ditjen EBTKE

Energy Efficiency Movement


Regulation /Standard Financial Support
Capacity Building
Institutional Strengthening

- MEMR - Jakarta Local Gov - GBCI - Gov Reg 70/2009 - SNI - Product Labeling - Gov Decree GB - Greenship Rating

- MOF - Central Bank

- MEMR - DANIDA - GBCI - Energy Manager - Energy Auditor - ESCO - Greenship Professional

- MEMR - DANIDA

- Incentive Scheme - Banking Regulation

- Portal Energy Efficiency - EE&C Database

NB & EB Greenship RatingTools


Kategori Appropriate Site Development Energy Efficiency & Conservation Water Conservation Material Resource and Cycle Indoor Health and Comfort Building Environment Management TOTAL POINT

New Building (NB) Criteria Points % 8 7 7 7 8 8 45

Existing Buildin (EB) Criteria Points % 10 9 9 8 9 6 51

17 26 21 14 10 13
101

16.8% 3 25.7% 1 20.8% 2 13.9% 9.9% 12.9% 100%

16 36 20 12 20 13 117

13.7% 30.8% 1 17.1% 2 10.3% 17.1% 3 11.1% 100%

Related Greenship Criteria to Energy Efficiency Measures

Site
Heat Island

Energy Effi& Conservation


PASSIVE DESIGN

Indoor Health & Comfort


Thermal Comfort

Bld Environment Management


Proper Commissioning

- OTTV
- Building Envelope - Natural Lighting

Micro Climate

- Natural Ventilation ACTIVE DESIGN -Plant Efficiency -Artificial Lighting - Bldg Transportation

Visual Comfort

Green Building Council Indonesia

PROJECT TO BE CERTIFIED
Pilot project
New Building : C
V 1. C V V 2. C V 3. V C V 4. V

Existing Building : C

Public Works Ministry Office Jakarta City Hall Jakarta Parliament Bldg Lemigas Bldg V 5. Austrian Embassy 6. ITSB 7. Jakarta Eye Center 8. Ciputra World Jakarta 9. Royal Springhill Apartment

1. V V

Environment Ministry Office 2. German Center 3. Central Park Mall 4. Grand Indonesia Office 5. Sampurna Strategic 6. Surya Toto 7. Bakrie Tower

As per end of May 2011 - 42 project : Registration & Exercised

Target 2011 : 4 building certified


6

PEMBERI TUGAS

DEPARTEMEN PEKERJAAN UMUM SEKRETARIAT JENDERAL


SNVT PENGEMBANGAN, PENGENDALIAN DAN PELAKSANAAN PEKERJAAN STRATEGIS BIDANG PU LAINNYA

Public Works Ministry Office

EEI (KWH/m2.yr)
300 250 200 150 100 50 250 155

0
Average Office Public Works Bldg

Saving 38%

LOUVRE GRILL ALUMINIUM METAL CLADDING

PHOTOVOLTAIC PANEL DOUBLE SIDE TYPE

GRASS AT ROOF TOP


MIRROR REFLECTOR INSULATION WALL

EEI (KWH/m2.yr)
300 200 100 0 Average Office This building 250 175

Saving 30%

GEDUNG TEKNOLOGI GAS PPPTMGB LEMIGAS

Austrian Embassy Jakarta

Photovoltaic Radiant Cooling Air tight and high thermal insulation building envelopes

EEI (KWH/m2.yr) Sun shading


300 250 250 200 Day lighting 150 100 50 0 Average Office

145

AEJ

Saving 42%

Existing Building

EEI (KWH/m2.yr)
300
250 200 150 100 50 0 250 210 173

Average Office

Before

After

Saving vs Ave : 30% Saving vs Previ : 18,6%


10

EE renovation of office in MEMR


AC-VRF multi split system Double glass panelling Sustainable materials On-line monitoring Space organization Eco friendly sanitary Airtighness & high ceiling T5 lighting

200 150 100 50 0

EEI (KWH/m2.yr)
170 95

Before Retrofit After Retrofit

Saving 41%
11

Barriers & Challenge to Green Building Adoption


Lack of Confidence & Experience
Limited supply of accredited professionals
Psychological resistance of change,

Lack of public awareness / demand


Lack of knowledge about the environment, social, and

economic risk of inefficient conventional building

Lack of Financial Issue Financial support Green products seen as expensive and unreliable

12

Opportunity for EE & Green Building Adoption


Opportunity :
Most building is still inefficient
Increasing demand from market throughout country Government initiative in supporting regulations

&standards, capacity building, institutional strengthening and financial support Green building movement

13

Green Building Council Indonesia

Thank you . . .

14

You might also like