Generac Standby Generator Automatic Voltage Regulator

s Excellent stability. s Responds in less than one cycle. s Less than 1% steady state regulation. s LED display indicates shutdown conditions. s Handles direct or brushless excitation. s Adjustable gain and stability for custom genset application. s Minimal start-up overshoot.

More Than Fast Response


Today's generator specifier must have voltage regulation response in mere hundredths of a second. Steady state regulation must be less than 1%, with an absolute minimum of overshoot at start-up. The Generac Standby Voltage Regulator meets those critical requirements. And measures up to performance standards only Generac regulators supply. We offer critical power that is as close to uninterrupted as possible with our affordable, flexible regulator.

Reliable, Consistent Regulation


You can count on less-than-onecycle response from your Generac automatic voltage regulator. Pulse-width modulation controls the Silicon-Controlled Rectifier, ensuring excellent latching and no false triggering. Bench testing can be performed without applying a load. Adjust for direct or brushless excitation with the flip of a switch. Gain and stability adjustments allow you to customize for your application.

Featured for Accurate Monitoring and Designed to Last


LED indicator lights monitor excitation, sensing voltage, and the SCR fire signal. Potential generator failure conditions such as loss of sensing or excitation voltage or failed circuit reference are reflected on the LED display to alert the operator to problems. Circuits are protected by a high temperature-resistant varnish. The Generac Automatic Voltage Regulator is built for long-term performance you can count on.

Automatic Voltage Regulator Specifications*


* Meets or exceeds all EGSA voltage regulator performance standards.

Response Temperature Tracking (32 - 120oF) Temperature Drift Steady State Regulation Droop (voltage over frequency)

Maximum Output Current to Field

Regulator Turn On SCR Control Maximum DPE Energy Startup Overshoot Startup Voltage Time Stability (100A, 0.8 PF) LED Indicators

Less than one cycle 0.41% <1% for 40oC change 0.75% RMS conditionally 0 - 4 Volts/Hz Selectable start 52 - 62 Hz (underfrequency pot) Rate 4/8 V/Hz (jumper select) 100A @ 1 cycle peak 10A @ 50oC cont. 20A one minute forcing 4 Volts RMS (DPE) Pulse width modulation 93% 10% conditionally 1 second 0% oscillation

Excitation Voltage Sensing Input Field Flash Panel Voltage Control Bench Testing Feedback Method Heat Sink Circuit Seal

Green - Excitation on Red - SCR fire signal Yellow - Sensing voltage present 40 - 240 Volts RMS 1 Ph 60 Hz., 190 - 240 Volts RMS On board 5K pot No load required State variable Stamped case High temperature varnish

User-Adjustable Settings
Voltage Gain Response Compensation Droop Excitation 20% @ regulator, 10% @ panel x10 variation 5 - 52 Hz 4 Volts/Hz<62 to 52 Hz Brushless or direct

Regulator Shutdown Conditions:


Loss of sensing voltage Loss of excitation voltage Loss of circuit reference

GENERAC POWER SYSTEMS, INC P.O. BOX 8 WAUKESHA, WI 53187 262/544-4811 FAX 262/544-4851
Bulletin 050120000S / Printed in USA 4.97, 6.97, 9.99 All specifications subject to change without notice.