Wall hydrant cabinet

FireDos wall hydrant cabinets WHS130

Wall hydrant cabinet with collapsible hose

Wall hydrant cabinet with hose reel

www.firedos.de
1

Illustrations and explanatory notes


Figure 1 Figure 2 Figure 3

FireDos wall hydrant cabinet WHS130 with collapsible hose The well-proven FireDos admixing system FD130 for extinguishing water flow rates of up to 130 l/min is the centrepiece of the system. The admixture rate is either 1% or 3%. The version of the wall hydrant cabinet shown above has a collapsible hose type C-42 with a length of 20 metres fitted. The delivery also includes a regular jet nozzle as standard. The optionally available foam concentrate can be supplied in standard tanks of 20 or 60 litres volume (the above illustration shows 20 litres). The connection to the water supply offers a female thread 1 .

FireDos wall hydrant cabinet WHS130 with hose on reel Design as already described on the left, but with a hose type S-25, length 30 metres on a hose reel. The above illustration shows the optionally available foam concentrate in a 60 litres standard tank.

Base frame Instead of being wall mounted the FireDos wall hydrant cabinets can also stand on an optionally available base frame, which is made of stainless steel.

www.firedos.de
2

Figure 4

Figure 5 Figures 4 to 7 Jet nozzles The FireDos wall hydrant cabinets are available with different jet nozzles. Figure 4: Regular jet nozzle, included in delivery at no extra price Figure 5: Optionally available medium foam nozzle

Figure 6

Figure 7 Figure 6: Optionally available adjustable hollow jet nozzle Figure 7: Foam attachment for the adjustable hollow jet nozzle shown in figure 6

www.firedos.de
3

Figure 8

Figure 9

Figure 10

Backflow preventer PN10 Depending on the connection situation of the FireDos wall hydrant cabinet, a backflow preventer might be necessary to prevent the return flow of the extinguishing water. Important: When the FireDos wall hydrant cabinet is supposed to be connected to the public water network, current local technical regulations must be observed. For operating pressures up to 10 bar.

Pipe disconnector PN16 Depending on the connection situation of the FireDos wall hydrant cabinet, a pipe disconnector might be necessary to prevent the return flow of the extinguishing water. Important: When the FireDos wall hydrant cabinet is supposed to be connected to the public water network, current local technical regulations must be observed. For operating pressures up to 16 bar.

Pressure reducer PN25 To adjust the operating pressure of the water supply to the maximum permissible pressure of the FireDos wall hydrant cabinet.