You are on page 1of 24

TENTATIVE BOQ FOR JAITALA RESIDENTIAL PROJECT

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

1 1.01

EARTHWORK Excavation for foundations, substructures, trenches,sumps, tunnels, pits etc. in all types of ordinary, sandy, gravelly, murrum soil with or without boulders,hard soils, slashy/marshy soil including necessary shoring, strutting and stacking selected material for backfilling or disposing excess excavated material within an initial lead of 100 m including dewatering complete as per specifications to depths from ground level. a) 0.0-0.3 m cum 1567.06

1.02

Disposal of surplus excavated material for the following leads beyond the initial lead of 100 m including loading/ unloading, dressing etc complete as per specifications a) Lead upto 500m cum 4701.14

1.03

Backfilling around foundations in trenches, sumps, pits, substructures, including thorough compaction upto 90% standard proctor density of backfill in layers not exceeding 200mm in depth, at all depths, watering etc. complete: a) With selected excavated earth b) With selected earth brought from outside including its supply and transport c) With coarse sand brought from outside including its supply and transport Note: Borrow areas shall be approved by Engineerin-charge before starting work. cum cum cum 300 200 200

1.04

Filling in plinth or where directed soil including compaction upto 90% Standard Proctor Density in layers not exceeding 200 mm in depth, watering etc. complete as per specifications a) With selected excavated earth b) With selected earth brought from outside including supply and transport c)With coarse brought from outside including its supply and transport (Borrow areas shall be approved by Engineer - in-charge before starting work.) cum cum cum 150 150 500

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

1.05

Providing and injecting chemical emulsion for preconstruction anti-termite treatment and creating a chemical barrier under and trenches, basemat excavation, top,surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, surrounding of pipes, wastes, conduits etc. treating termite mounds within the plinth and contingent apron etc. Complete(plinth area of the building at ground floor only shall be measured) chlorophyriphos 20% EC shall be used asper specifications.

sqm

540

1.06

Excavation in rock including removal of excavated material, separating and stacking as directed the rock pieces and disposing the balance material upto 100 m from the periphery of the area,etc complete Hard Rock Blasting not permitted a) 0.3-1.5 m PLAIN AND REINFORCED CONCRETE WORK Providing and laying plain cement concrete in all kinds of work below plinth upto all depths complete but excluding form work using 20/40 mm nominal size aggregate and coarse sand a) Concrete Mix 1:2:4 (1 cement : 2 coarse sand :4 aggregate) b) Concrete Mix 1.4:8 (1 cement : 4 coarse sand : 8 aggregate) cum cum 181.2 81

i)

cum

7834.85

2 2.01

2.02

Providing and laying plain cement concrete (1:2:4 ) over roof as leveling course Same as item no. 2.01 but in super structure upto m height a) Concrete mix 1:2:4 (1 cement : 2 coarse sand :4 aggregate) 10

cum

2.03

cum

5000

2.04

Providing and laying 1:5:10 mix (1cement :5 fine sand : 10 broken brick ballast of 20 mm nominal size)including ramming curing etc.complete below plinth.

cum

271.8

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

2.05

Providing and placing reinforced cement concrete for all kind of work up to 5 m below grade level upto plinth level (Finished Floor level) excluding reinforcement and formwork but including compaction, leveling ,finishing,curing etc. complete. (Block Foundatons like pump pads, equipment and tank foundations shall be paid under this item even if some portion of the foundation is above plinth level) a) Grade M20 concrete cum 375

2.06

Extra for placing reinforced cement concrete at depths exceding 5m below grade level but not exceeding 10m for any garde of concrete. Providing and placing reinforced cement concrete for all kind of work in superstructure upto 10m above plinth level excluding reinforcement and formwork but including compaction leveling ,finishing,curing etc. complete. a) Grade M15 concrete b) Grade M20 concrete

cum

2.07

cum cum

410 300

2.08

Extra over item no 2.07 for placing reinforced cement concrete at heights greater than 10 metre above plinth level for any grade of concrete Providing, placing and fixing in position precast concrete units including suitable formwork to provide smooth finish, casting, curing storing, protecting under appropriate conditions, erecting them in position etc. complete including providing, lifts tackles, tools etc (reinforcement and inserts shall be paid seperately)using concrete of grade M20 a) Trench, sump or hatch covers b) Perforated R.C.C Slab any thickness with 20mm dia holes @ 100mm c/c both ways as per drawing

cum

2.09

cum sqm

2.1

Providing and fixing in position 40mm thick precast jail of approved design in cement mortar 1:4 with 3mm dia M.S wire used as reinforcement. FORMWORK: Providing erecting and removing straight formwork in shuttering plywood for concrete items including forming chamfers, drip moulds, pockets etc., and including scaffoldingand centring upto propping height of 5 m, finishing concrete surface after striking the formwork etc.complete (Net area of concrete formed shall be measured): a) For smooth finish of surfaces below plinth level

sqm

2.11

sqm

4530

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

b) For smooth finish of surface above plinth level at all heights. 2.12 Providing,erecting and removing formwork in shuttering plywood in column's and beams etc. at any position and at all levels including all operations required for making required shapes and sizes complete as per specifications and drawings Providing, erecting and removing circular and/ or curved formwork in shuttering plywood for concrete items including forming chamfers, drip moulds, pockets etc. and including scaffolding,centring, finishing concrete surface after striking the form-work etc.complete at all heights (Net area of concrete formed shall be measured). a) For non-exposed surfaces below plinth level. b) For smooth finish of surface above plinth level at all heights. 2.14 Extra over item 2.11 for centring and shuttering where height of propping exceeds 5m,including providing adequate bracing, proping complete.(plan area will be measured) REINFORCEMENT STEEL :Supplying, cleaning,cutting, bending, binding with 16 SWG soft annealed wire and placing in position on/at all levels and locations as per drawings, including handling and transport complete for all R.C.C works at all height: a) T.M.T

sqm

1000

sqm

1000

2.13

sqm sqm

sqm

2.15

tonnes

2500

3 3.01

MASONRY AND ALLIED WORKS Providing brick masonry with bricks of class 75, in foundation and plinth including curing etc. complete in: a) Cement mortar 1:6 ( 1 cement : 6 coarse sand) cum 500

3.02

Providing brick masonry with bricks of class designation 75 in cement mortar including scaffolding,curing etc for brick work above plinth at all levels and heights, joints/wall surface prepared either for pointing or plastering complete: a) Cement mortar 1:6 ( 1 cement : 6 coarse sand) cum 6496.87

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

3.03

Half brick masonry work in cement mortar 1:4 (1 cement: 4 coarse sand) incl. providing 2 nos 6 mm dia M.S. bars in every fourth course, excluding cost of reinforcement at all heights and levels. PLASTERING Providing interior plaster in cement mortar 1:4 (1 cement;4 coarse sand) for walls, columns, beams etc. Including chipping concrete surface, finishing, scaffolding, providing grooves, bands, mouldings etc. complete at all heights and levels. a) Cement plaster 12 mm thick on fair face of brickwork and 15 mm thick on rough face of brickwork

sqm

4 4.01

sqm

40000

4.02

Providing 6mm thick plain faced cement plaster in cement mortar 1:4 for underside of ceillings including chipping concrete surface, finishing, scaffolding, providing grooves, bands mouldings etc.complete

sqm

9060

4.03

Providing 18 mm thick exterior cement plaster in two layers, under layer 12 mm thick cement plaster 1:5 (1Cement ; 5 coarse sand) finished with top layer 6 mm thick cement plaster 1:3 (1 Cement : 3 coarse sand) finished rough with sponge, for external surfaces including chipping concerete surface providing bands, drip moulds, grooves etc. finishing curing scaffolding etc, complete (Waterproofing compound where specified shall be paid for seperately)

a) Sand faced plaster in cement mortar 1:3 4.04 Providing and fixing in position mesh/jali for use in plastering including cutting overlaps fixing nails etc complete 20mm mesh size 18 gauge galvanised chiken wire mesh

sqm

16500

sqm

1000

4.05

Cement poiniting on brickwork in cement mortar 1:3 (1Cement : 3 Fine Sand) including ranking joints, scaffolding, curing etc a) Flush Pointing b) Ruled Pointing sqm sqm

FLOOR FINISHES AND ALLIED WORKS

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

5.01

Providing and fixing 1st quality ceramic glazed tiles conforming to IS : 13753 of minimum thickness 5 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA, or equivalent make in all colours, shades except begundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

sq.m

500

5.02

Providing and laying 300X300 mm minimum 5 mm thick Ceramic glazed floor tiles conforming to IS 13753 of 1st qualirty of NITCO, ORIENT, KAJARIA, SOMANY or equivalent make in all clolours, shades except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc. complete.

sq.m

8060

5.03

Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. 1) size of tile 60x60 cm Cement concrete flooing 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. I). 25mm thick with 12.5mm nominal size stone aggregate ii). 40mm thick with 20mm nominal size stone aggregate iii). 50mm thick with 20mm nominal size stone aggregate

sq.m

1000

5.04

sq.m sq.m sq.m

5.05

Providing an laying R.C.C floor with nominal reinforcement and mix 1:1.5:3 (1 cement :1.5 : coarse sand : 3 aggregrate) reinforcement to be paid seperately

cum

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

5.06

Providing and laying non-metallic dry shake type surface hardener 3 kg/sqm, of approved make and brand on concrete floors all as per manufacturer's specifications and as directed by Engineer-in-charge.

sq.m

6 6.01

DOORS & WINDOWS Providing and fixing ISI marked flush door shutters nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 30mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sq.m 1112.45

a)

6.02

Providing, and fixing best quality hydraulic door closers as per IS: 3564 including all screws, nuts etc. complete.

each

80

6.03

Providing and fixing best quality mortice door lock (vertical type) as per IS: 2209 with: a) Knob type door handle each

80 490

ALUMINIUM WORK 6.04 Providing and fixing anodised aluminium work for doors, windows ventilators and with extruded built up standard tubular and other sections of approved make conforming to IS: 733 and IS:1285, anodised trasparent or dyed to required shade according to IS: 1868 ( Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including neccessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium snap beading for glazing / panelling, C.P brass/stainless steel screws, all complete as per architectural drawings and the direction of Engineer- Incharge ( Glazing and panelling to be paid for seperatly)

sq.m a) For fixed Portion b) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivions and making provision for fixing of fittings whenever required including sq.m the cost of PVC / neoprene gasket required (fittings shall be paid for separately)

379.8

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

6.05

Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions tec. With PVC / neoprene gasket etc.Complete as per the architectural drawings and the direction of engineer-in-charge. ( Cost of aluminium snap beading shall be paid in basic item) a) With glass panes of 4.0mm thickness (weight not less than 10.0Kg/sqm) b) With glass panes of 5.50mm thickness (weight not less than 13.75kg/sqm)

sq.m sq.m

94 94

7 7.01

PAINTING ,WHITE WASHING ETC. Providing one coat of approved primer and two coats of paint of approved manufacture, brand, colour and shade on interior surface including cleaning and preparing surfaces, applying coat of putty, scaffolding etc. complete: b) Oil bound distemper d) Synthetic enamel sq.m sq.m 40000 1112.45

7.02

Providing two or more coats of cement based paint ("Snowcem" or equivalent) to give even smooth shade, of approved manufacture, brand, colour and shade on exterior surfaces including cleaning, preparing surface, scaffolding, curing etc. complete at all heights and levels.

sq.m

16500

8 8.01

WATER PROOFING Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc by applying cement slurry mixed with water proofing cement compound consisting of applying: a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compund @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

sqm

648

8.02

Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations.

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS 2645 over the RCC slab including cleaning the surface before treatment.

sq m

1812.04

Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with proprietary water proofing compound conforming to IS 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.

After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. Finshing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand) admixed with proprietary water proofing compound conforming to IS 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x300 mm square.

8.03

Providing and fixing unplasticised - PVC ( workingpressure 4 kg per sqcm) rain water pipes and all necessary fittings/ accessories confirming to IS : 4985 including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for the thermal expansion, complete at all heights and levels. a). 100 mm dia b) 150mm dia m m 200 300

9 9.01

WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fitting i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charg. Concealed work including cutting chases and making good the walls etc. a) 15 mm nominal outer dia pipes

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

b) 20 mm nominal outer dia pipes c) 25 mm nominal outer dia pipes d) 32 mm nominal outer dia pipes 9.02 Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of engineer in charg. a) 15 mm nominal outer dia pipes b) 20 mm nominal outer dia pipes c) 75 mm nominal outer dia pipes d) 100 mm nominal outer dia pipes 9.03 Providing and fixing 15 mm dia. C.P.brass bib cocks conforming to IS: 781 of tested quality and approved make and design. Providing and fixing C.P. brass stop cocks conforming to IS: 781of tested quality and approved make and design a) 15 mm dia b) 20 mm dia 9.05 Providing and fixing best quality white vitreous China wash down (European type) water doset of approved make conforming to Pattern 2 of IS: 2556 (Part-11) comprising of white glazed closet with 'P or'S' trap, plastic seat and lid flush cistern of 12.5 lit capacity etc., complete including C.I pipe connection up to downtake pipe on external wall and making good chases and holes etc. complete in all respect Providing and fixing best quality approved make and design 550 mm X 400 mm white glazed wash basins including painted C.I. brackets screwed to wall with raw! plug, bolts and screws, 2 Mos.15 mm C.P. pillar tap of approved make, 32 mm C.P waste complete with C.P.bottle trap with C.P pipe pieces upto wall or floor level plus 40 mm lead waste pipe embedded in floor/wall from 32 mm C.P waste extension pipe to the C.I waste shaft on the outside wall complete with brass unions and plumbers wiped soldered joints as directed, with necessary cleaning eyes including making chases and holes and making good the same etc. complete each each 200 300

each

500

9.04

each

225

9.06

each

80

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

9.07

Providing and fixing sink of best quality, approved make and design including painted C.I. Brackets screwed to wall with raw! plug, bolts and screws, 15 mm C.P pillar tap of approved make, 32 mm C.P.waste complete with plug, C.P. bottle trap, C.P. pipe piece 40 mm lead waste pipe embedded in floor from 32 mm C.P waste shaft on the outside wall complete with brass unions and plumbers wiped soldered joints as directed, with necessary cleaning eyes including making chases and holes and making good the samer etc. complete a) 600 mm X 450 mm X 250 mm stainless steel sink of 18 gauge

each

80

9.08

Providing and fixing 20 mm dia.towel rail of approved make and design, 750 mm long screwed to wall with raw! plugs and C.P. brass screws etc. complete: a) Anodised aluminum towel rail each 225

9.09

Providing and fixing best quality liquid soap dispensers with C.P. brackets, cap etc., complete of approved make and design: a) Plastic dispenser each 225

9.1

Providing and fixing 600 mm X 450 mm approved make berelled edge, mirror with 6 mm thick backing and predrilled holes, fixed to wooden cleats with C.P. Brass dome headed screws etc., complete with: a) Asbestos Cement sheet backing Providing and fixing white glazed vitreous china accessories of size 150 mm x 150 mm complete including finishing with white cement a) toilet paper roll holder b) soap dish each 225

9.11

each each

225 225

9.12

Providing and fixing C.I. Floor trap as per IS: 3989 with hinged grating, fixed in cement concrete, connecting to C.I. Pipe/bend, with lead joints including cutting holes in walls and making good the same etc.,complete: a) Floor trap as per Table 18 of IS : 3989 i) 75 mm nominal dia. And 100 dia. Grating ii) 100 mm nominal dia. And 200 dia. Grating each each 100 125

Sr. No.

DESCRIPTION

UNIT QUANTITY RATE

9.13

Providing and fixing stoneware gully traps with C.I.grating complete with C.I. 300 mm X 300 mm (inside size) hinged frame and cover including 300 mm X 300 mm (inside size) brick masonry chamber with 230 mm thick wall in cement mortar 1:4 and with 20 mm thick cement plaster in cement mortar 1: 3 on insides, 150 mm thick 1:3:6 concrete bedding and concrete for filling space between chamber walls and gully trap, excavation, backfilling etc. complete

each

100

9.14

Providing and fixing C.I. soil, waste and vent pipes conforming to IS : 3989 with G.I clamps on the outside of waits or columns including necessary bends, off-sets junctions, ven cowl, shoes etc., complete with lead joints perfectly air and water tight including necessary scaffolding and two coats of white zinc based paint of approved quality over one coat of red oxide primer with necessary inspection eyes complete:

a) 75 mm nominal dia. b) 100 mm nominal dia. 9.15 Providing stoneware glazed pipes conforming to IS: 651, laying to slope, jointing with stiff mixture of cement mortar 1:1 testing etc., complete (Earthwork and concrete work shall be paid separately): a) 100 mm dia b) 150 mm dia 9.16 Constructing brick masonary manholes, sumps, inspection chambers in 230 mm thick brick wall in cement mortar 1:2 and 20 mm thick plaster in cement mortar 1:2 on both faces including 250 mm minimum thick foundation and coping in M15 concrete, plastering and cement rendering channels and slopping bottom fixing approved quality C.I steps at 300 mm c/c openings for inlet and outlet pipes, excavation and backfilling, dewatering etc. complete ( C.I manhole cover frame and steps will be paid separately ) for

m m

100 125

m m

a) 1000 mm X 1000 mm i. Upto 0.5 m depth ii. 0.5 m to 1 m depth iii. 1 m to 2 m depth b) 610 mm X 610 mm i). Upto 0.5 m depth ii.) 0.5 m to 1 m depth

each each each each each

ECT

AMOUNT

AMOUNT

AMOUNT

AMOUNT

AMOUNT

AMOUNT

AMOUNT

AMOUNT

AMOUNT

AMOUNT

AMOUNT

AMOUNT