Switching-Mode Power Supply Design

Approach
As explained in the introduction, a power supply is a buffer circuit that is placed
between an incompatible source and load in order to make them compatible. In this
section we explore some simple circuits that can be placed between a 12 Vdc battery
and a 5 Vdc load to make them compatible. The buffer circuits are simple in that we
will restrict the parts to one each or less of the following parts:

Parts List

• variable resistor
• breakdown diode
• switch
• diode
• single winding inductor
• capacitor

We will be concerned only with the power conversion part of the circuit, not the
control. We will assume that the circuits are open loop and the output voltage is
controlled manually by the value of a variable resistor or the duty cycle of a switch.

Although simple from a parts basis, the circuits we will explore with these parts are
not necessarily simple from an analytical viewpoint. Some of them will contain right-
half-plane zeroes, an interesting topic that will be discussed later in this tutorial.

The first two topologies discussed will not be switching-mode circuits, but dissipative
power supplies. The motivation for this is to show the importance of efficiency in
power conversion -- the major reason switching-mode power supplies are used.

In all of the following examples we will assume a 12 Vdc source and the goal of
providing 5 Vdc at a maximum load of 20 A, which equates to a maximum load power
of 100 W and a minimum load resistor of 0.25 ohms.

In comparing regulators we will be using efficiency as one of the figures of merit.


Efficiency is defined as:

Efficiency = (Pout/Pin)
or in terms of power loss
= 1/(1 + (Ploss/Pout))
where efficiency is a fraction that can be converted to percent by
multiplying by 100
Dissipative Power Supplies
Top | Contents | Home | Map

Dissipative regulators achieve regulation by a purposeful conversion of excessive


power to heat, unlike switching-mode power supplies which do not rely on a heat
conversion for regulation. Switching-mode power supplies would be 100% efficient if
components were ideal. Dissipative regulators convert heat with either a series or a
shunt element.

Series Regulators

We start our investigation of simple topologies by selecting the variable resistor from
our parts list and connecting it between the power source and load. What we get is a
simple open-loop series regulator shown in Figure 2-1. R1 is often a transistor.

D
Figure 2-1: Series Regulator

Given:

• Vin = 12 Vdc
• R2 = 0.25 ohm
• Vo = 5 Vdc

Solving and listing the parameters of interest:

• I = 20 A
• R1 = 0.35 ohms
• Pin = 240 W
• Pout (R2) = 100 W
• Power R1 = 140 W
• Efficiency = Pout/Pin = 0.417 => 42%

R1 is varied to obtain 5 Vdc at Vo resulting in 20 A current flowing in the loop and


the load resistor R2. Notice that the 5 V output is obtained by dropping voltage
across the series resistor R1, hence the name series regulator. To provide 100 W to the
load, 240 W is required of the source and 140 W of power is wasted in R1 -- not very
efficient. If the load power is reduced, so is the input power and the efficiency remains
the same for all loads. Since the current cancels when made explicit in the efficiency
equation, the efficiency of this circuit simplifies to Vo/Vin. As we shall see in the next
section, this is not true of shunt regulators.

Notice that the topology is that of a voltage divider. Voltage and current dividers are
used extensively in power supply circuit design and modeling. A future section will be
devoted to them.

Shunt Regulators

From our parts list, we now add a breakdown diode across the load in Figure 2-1 to
get the shunt regulator shown if Figure 2-2.

D
Figure 2-2: Shunt Regulator

This is a very popular topology because it provides voltage regulation with only two
parts, a fixed value R1 and the breakdown diode. The circuit also has inherent short-
circuit protection as long as the wattage of R1 is selected so that it can operate into a
short circuit. The major disadvantage of the circuit is poor efficiency, especially at
lighter than full load. If the load power is a small fraction of total system power, this
can often be tolerated. It should be noted that the topology is also the same as a series
regulator using a breakdown diode as over voltage protection. As we will see in the
section on switching-mode power supply topologies, over voltage protection is a very
important consideration.

Assume the same conditions as Figure 1-1 and that the breakdown diode breaks an
infinitesimal amount above 5 Vdc so it draws no current. Then the the efficiency of
the circuit is the same as the 42% of the series regulator circuit.

Now reduce the load to one half by increasing the load resistor R2 from 0.25 ohms to
0.5 ohms so only 10 A flow in the load and the load power is 50 W. The voltage would
rise, but the breakdown diode constrains it to 5V and the excess current flows in the
breakdown diode. The efficiency is now 50/240 W => 21% compared to 42% for the
series regulator example. At zero load current, the efficiency is 0%.

In practice, some current always flows in the breakdown diode. This leads to the
conclusion that a series dissipative regulator is always more efficient than a shunt
dissipative regulator, everything else being equal.
One interesting observation about the shunt regulator is the maximum efficiency
occurs at an input voltage that is only a function of the input voltage tolerance and
independent of the R1 or R2. By setting up the power loss as a function of the circuit
parameters and input voltage tolerance, taking the partial and setting to zero, the
following equation is obtained.

Vin = Vo*(1+SQRT(1-a))/a
where a = 1-tolerence.
and
R2 = a*(Vin - Vo)/Imax
where Imax is the maximum load current

For our example and a 20% input voltage tolerance (a = 1-0.2 = 0.8), the input
voltage that yields the maximum efficiency and the value of R1 are:

Example:
Vin = 5*(1+SQRT(1-0.8))/0.8 = 5*(1+0.447)/0.8 = 9.05 Vdc
R1 = 0.8*(9.05 - 5.0)/20 = 0.162 ohms
Efficiency = Pout/Pin => 100 W / 181 W => 55%

By selecting the optimum input voltage (instead of 12V) for a 20% tolerance, the
maximum efficiency of the shunt regulator has been increased from 42% to 55%.
However, note that the efficiency of a series regulator for the same lower input
voltage (5/9.05 => 55%) is also increased to the 55% maximum efficiency of the shunt
regulator, as would be expected.

This finishes our look at dissipative regulators. In our examples, the power losses were
always greater than the load power for a 12 Vdc input and 5 Vdc output -- a terrible
waste of power.

What are the system implications of this power loss?

Implications of Power Loss

Two factors influence the size of a power supply, the size of the components and
packaging, and the thermal density - the power dissipated per unit volume. The latter
is a very useful measure. It is used to discuss the system impact of efficiency on
system size, weight, reliability, cost of power, and cost of cooling.

Assume that an electronic load and its cooling system operate at a power density that
limits the temperature rise above ambient to a fixed value. If the power supply uses
the same type of components and is limited to the same temperature rise, then the size
of the power supply is determined by its efficiency -- assuming you can packaged the
parts in the thermal-density volume, which is usually the case.
Figure 2-3 shows three systems with the same electronic load with power supplies of
three different efficiencies, 35%, 65%, and 83%. The volume of the load is shown in
blue and the relative volume of the power supply is shown in red. For equal thermal
density design, a 35% efficient power supply is 1.86 times the size of the load, a 65%
efficient supply is 0.54 the size, and a 83% efficient supply is only 0.20 the size of the
load. These efficiencies are not arbitrary but represent the history of power supply
design for 5 Vdc logic circuits.

D
Figure 2-3: Equal Thermal Density Vs Efficiency

The first supplies for 5 Vdc logic circuits used transformer-rectifier sets followed by
series dissipative regulators. The efficiency for power conversion was about 35% and
the power supplies were larger than the load and required more cooling than the load.
This was totally unacceptable to systems engineers and considerable pressure was
applied to designers to reduce the size of the power supply. The initial approach was
to increase the power density of the power supply, by running the components hotter,
taking out design margin, and packaging the power supply differently than the rest of
the load. This reduced the size of the power supply but increased the cost and greatly
reduced the reliability due to higher component temperatures. In fact, power supply
reliability got so bad it was usually the major reason for system failure. Switching-
mode power supplies were avoided since they were perceived (erroneously) as an
electromagnetic interference problem.

Finally, after successful use of 20 kHz switching-mode power supplies in several


systems, they became the norm. For more than a decade, these power supplies ranged
from about 62% to 71% efficient. A 65% efficient power supply is shown in Figure 2-
3. Even though the power supply was only 0.54 the volume of the load, the pressure
remained for smaller power supplies, hence more efficiency. This was achieved with
Schottky diodes, synchronous rectifiers, and power MOSFET transistors to get to the
present 83% efficiency for 5V logic. The power supply is about 0.2 the volume of the
load and is shown in Figure 2-3. Efficiency keeps improving and you now see
efficiency of greater than 90% for 5V power supplies.
Unfortunately, the trend for logic circuits is to use lower voltages. For the 1.8 to 2.0
Vdc supplies used for 0.25 um logic, even using all the techniques to get 83%
efficiency for 5 Vdc logic only results in 65% efficiency for a 1.8 Vdc power supply.
Again, efficiency keeps improving with time even for low voltage power supplies.

The system implications of poor efficiency not only include size and the associated
weight, but the cost of the electrical power and cooling added to the system due to
poor efficiency. Electrical power is often included in system trade-off calculations to
determine the system cost of poor efficiency. Of equal or greater impact is the cost of
cooling, it is often greater than the cost of the wasted electrical power and is often left
out of trade studies.

The bottom line of this discussion is that there are overwhelming system reasons to
use power conversion techniques that are ideally 100% efficient and to constantly
work on less than ideal components to get as close to 100% efficiency as possible. For
the most part this means dissipative techniques are out of favor and lossless
techniques, including switching-mode power supplies, are in favor.

Switching-Mode Power Supplies

The primary advantage of switching-mode power supplies is they can accomplish


power conversion and regulation at 100% efficiency -- given ideal parts. All power loss
is do to less than ideal parts and the power loss in the control circuitry. In this section
we explore some of the switching-mode power supplies that can be constructed using
only one each of the parts from our simple.

Heater

One of the simpler switching-mode power supplies is one that is used to control a
heater. For example, an inexpensive space heater I have applies full household ac
voltage to a heater element when the temperature is less than that set by a simple
thermostat and turns the ac power off when the temperature is above the set point.
The heater turns on and off every several minutes to keep the room temperature
constant. Closer to our example might be a heater in a crystal-oscillator oven used to
keep the temperature of the crystal within narrow limits. For this circuit, we only
need to use the switch from our list of components.

The schematic is shown in Figure 2-4 below.


D
Figure 2-4: Heater Schematic

As with our previous examples, Vin is 12 Vdc and the load resistor R2 is 0.25 ohms.
The objective is to open and close the switch so that the average voltage across R2 is 5
Vdc. The wave form of the voltage across R2 is shown in Figure 2-5.

D
Figure 2-5: Heater Waveform

This is the first waveform we have encountered in this tutorial. In your design of
switching-mode power supplies you will have to work with many waveforms and
calculate properties such as period, frequency, duty cycle, harmonics, average and
rms (root-mean-square) values -- both with and without the dc component, etc.
Unless you really like solving definite integrals and doing Fourier analysis, you will
want a handbook that gives you characteristics of common pulse and periodic
waveforms.

In Figure 2-5, the period, T, of the waveform is Ton + Toff, and by definition, the
reciprocal of the period is the frequency. For example, a period of 50 us results in a
frequency of 20 kHz. The ratio of Ton/(Ton + Toff) is called the Duty cycle, D, -- a
parameter much used in switching-mode power supply calculations. The average
value of the waveform over a period is shown by a dotted line.

For those who have had calculus you will remember the the average value of a
function is (1/T)*(Integral zero to T of the function). In this case you have to evaluate
the integral from 0 to Ton and from Ton to T and add them. Or you can look it up in
a handbook and see the average is Vin*D.

Again, those with calculus know to get the the RMS (Root-Mean-Square) of a
function you first square it and then take the mean or average of the result as before.
You then take the square root to get the answer. Or you can look it up in a handbook
and see the RMS is Vin*SQRT(D).

Example:
Vin = 12 Vdc
Vo = 5 Vdc (average)
D = (5 V)/(12 V) = 0.417
Vrms=(12 V)*SQRT(0.417) = (12 V)*0.645 = 7.75 Vrms.
Iaverage = (0.417)*(12 V)/(0.25 ohm) = 20 A
Pin = (12 V)*(20 A) = 240 W

These are the answers we got in our series and shunt regulator examples and are no
surprise.

We might expect that the power in R2 is the same as before, (5 V)*(20 A) = 100 W,
but that doesn't make sense, since we are taking 240 W from the source and there is
nowhere it can go except into R2. Recalling that power in a resistor is
(Vrms)*(Vrms)/R, and the rms voltage is 7.75 Vrms, then we get (7.75 Vrms)(7.75
Vrms)/(0.25 ohms) = 240 W in R2, and everything balances.

Notice that the rms value of the waveform is higher than the average value. This is
true in all duty cycle controlled switching-mode power supplies. Also notice that all
the power taken from the source is delivered to the load assuming ideal components.
This will be true in all the examples discussed in this section, however, there is one
notable exception. The exception is if you try to switch directly into a capacitor,
which we discuss next.

Switched Capacitor Converter

From our parts list we will add a capacitor to our heater circuit and get the schematic
shown in Figure 2-6.

D
Figure 2-6: Switched Capacitor Converter

One might erroneously argue that the only dissipative element in this circuit is the
load and all energy from the source goes to the load. Therefore if we control the switch
to maintain 5 Vdc on the capacitor we have a 100% efficient converter. This is not the
case since charging a capacitor directly from from a voltage source or capacitor
dissipates as much energy as is transferred to the capacitor. This problem, Energy
Loss in Charging a Capacitor, is discussed in the problem section of the SMPS
Technology Knowledge Base. Since you will see this circuit in many variations
throughout your design career, it is well to recognize it and understand it. This circuit
has it uses, but high efficiency power conversion from a source that is significantly
different from the output is not one of them. In order to keep the voltages near each
other and increase efficiency, many applications switch topologies during operation
(e.g. from a voltage doubler to a tripler) to improve the efficiency of this circuit.

Switched Inductor Converter

From our parts list we will add an inductor and diode to our heater circuit and get the
schematic shown Figure 2-7.

D
Figure 2-7: Switched Inductor Converter

Unlike our capacitor example, this circuit is 100% efficient with ideal components.
It's major problem is terrible load transient response. If the load is removed, the
current must continue to flow in the inductor and the output voltage tends to go to
infinity. If the load is increased by two, the output voltage is halved, since the
inductor current remains the same until adjusted by the L/R time constant. Because
of the terrible load transient response this circuit is rarely used as a voltage regulator.
But it is interesting to note that in the type of dc-dc converter we are discussing in
this section, an inductor is always needed, but a capacitor is not. It is also interesting
to note that this is the equivalent circuit of a switching-mode control of current in a
motor field winding, which is represented as an inductor and series resistor.

Note that the diode is necessary to provide a current path for the inductor current
when the switch opens. Otherwise the voltage across the inductor would build up to
several hundred volts until the energy stored in the inductor would dissipate as an arc
in the switch, charge the parasitic capacitance of the inductor windings, or result in
some other undesired phenomenon.

A rule of thumb, which we will use later for selecting a value of inductance in an LC
filter, is to start with an inductor value that results in a peak-to-peak inductor current
that is 10% of the full load current. For our example of a 12 V input, 5 V output, 20 A
load, and 20 kHz switching frequency, the inductor can be calculated from the
formula V = L*(di/dt). This is a formula you will constantly use in switching-mode
power supply design, hence worth memorizing.

Example:
L = V*Ton/I
V = 12 V - 5 V = 7 V
Ton = D*T = 0.417*50E-6 = 20.85E-6
I = 20 A * 10% = 2 A
L = (7 V)*(20.85E-6 s)/(2 A) = 72.3 uH
=> 75 uH

The resulting two amps (1.94 A) peak-to-peak ripple current gives about a half volt
peak-to-peak ripple current in the 5 V, 20 A load. Note that you can decrease the
ripple current to as small as you want by increasing L, or make L smaller by allowing
more ripple current.

Buck Converter
From our parts list we will add a capacitor to our switched inductor converter and get
the buck converter as shown in Figure 2-8.

D
Figure 2-8: Buck Converter

The buck converter goes by many names, voltage step-down converter, current step-
up converter, chopper, direct converter, et.al. No matter the name, converters derived
from this topology account for 80 to 90 % of all the converters sold. Understanding its
operation is basic to switching-mode power supply design.

Our first problem is to select initial values of L and C. Later the design can be
optimized. In our switched inductor example we used the rule of thumb of designing L
to get a peak-to-peak ripple current of 10% of the full load output current and got a
value of 75 uH. We will use overshoot to get a value for C and then check the output
ripple.

The problem of overshoot, Output Filter Design - Overshoot, is discussed in the


problem section of the SMPS Technology Knowledge Base and it is an important
consideration in output filter design -- enough so that it is prudent to consider
overshoot first, rather than output ripple as is normally done, so that overshoot is not
forgotten. We will use a simple rule of thumb of making the characteristic impedance
of the filter, Zo, equal the load resistor, which gives an overshoot of SQRT(2)= 1.41
and a slightly over-damped filter at full load. For our example, if our full load 20 A is
removed, the 5 Vdc voltage goes to (5 V)*1.41 = 7.07 V.

Solving Zo=SQRT(L/C) for C = L/(Zo*Zo) = 75E-6/(0.25*0.25) = 1,200 uF


In checking for ripple we will use another formula that is used enough in switching-
mode power supply design that it is worth memorizing, V = (1/C)*INTEGRAL(
i(t)*dt), which combined with V=L*(di/dt) allows us to calculate output ripple due to
the capacitor capacitive impedance (which is often less than the contribution of
capacitor equivalent series resistance (ESR) to output ripple).

Example:
Solving for current as a function of time in the output capacitor
The current in the capacitor is the triangular current in the inductor which
has the slope K
K = di/dt = V/L, from V=L*(di/dt)
K = (12 V - 5 V)/(75 uH) = 0.093E+6 A/s
Solving for capacitor ripple voltage
V = (1/C)*INTEGRAL ((K*t)dt)
= (K/(2*C)*t^2
where t = Ton
Ton = D*T = 0.417*(50E-6 s) = 20.85E-6 s
V = ((0.093E+6 A/s)/(2*1200E-6 F))*(20.85E-6 s)*(20.85E-6 s)
= 0.0168 V

With less than 17 mV ripple due to the capacitance of C and assuming a 50 mV ripple
specification, this would leave 33 mV for ripple due to the equivalent series resistance
of C or for design margin. If we needed less overshoot or less ripple, we could
experiment with other values of LC, however, this seems good enough for our tutorial
purposes.

Two useful properties for any filter are the characteristic impedance, Zo=SQRT(L/C),
and the cutoff frequency, Fo = 1/(2*PI*SQRT(L*C). These can be calculated or read
off of impedance graph paper. Impedance graph paper is so useful that it should
always be handy. How to use it for many purposes will be discussed in this tutorial.
Using impedance paper we look for the intersection of L and C and read Zo on the
Ordinate and Fo on the Abscissa. Or we can calculate it.

Example:
Zo = SQRT(L/C) = SQRT(75E-6/1200E-6) = 0.25 ohms
Fo = 1/(2*PI*SQRT(LC)) = 1/(6.28*SQRT(75E-6*1200E-6) = 532 Hz

We will start our understanding of the buck converter by turning the switch on and
off and examining what happens, first as a function of time and then in the state-
plane.

The state-plane, sometimes called the phase-plane, is a plot with two state-variables
as coordinates. State-variables are variables whose initial conditions are required to
determine the future behavior of the system. Typically they are anything that stores
energy, like inductors and capacitors, or anything with a memory, such as a flip-flop.
Common state-planes in switching-mode power supply design are inductor current
versus capacitor voltage in the output LC filter (approximates load current and load
voltage), the derivative of capacitor voltage (approximates the inductor current
without the dc component) versus capacitor voltage, and the derivative of the output
capacitor voltage versus the voltage (you do not have to be concerned with any
currents and the derivative always crosses the voltage axis at right angles).
Trajectories are unique for a set of initial conditions and never cross each other.
Trajectories in the state-plane can easily be determined by most SPICE programs
that are used to determine the time response of a circuit.

Buck Converter Turn-On and Turn-Off Versus Time

First let's turn on the switch and watch what happens to the output voltage versus
time. For illustrative purposes we want the filter under-damped so we will decrease
the load by increasing the load resistor from 0.25 ohms to 1.0 ohms.

As shown in Figure 2-9, the wave form overshoots 12 V to 20 V and then has a
damped ringing related to the filter resonant frequency (532 Hz) and final settles at 12
V, the input voltage. If the filter were unloaded, it would overshoot to 24 V (twice the
input voltage) and would oscillate between zero and 24 V at a frequency of 532 Hz.

Figure 2-9: Buck Converter Turn-On and Turn-Off Versus Time

The turn-off waveform starts at 12 V and exponentially decays to zero volts without
ringing. The cycle then starts again.

It is instructive to look at both of these events in the state-plane.

Buck Converter Turn-On and Turn-Off in the State-Plane


Figure 2-10 shows an approximate state-plane plot of the turn-on and turn-off events.
The horizontal axis is the voltage across the output capacitor which approximates the
output voltage. The vertical axis could one of several state-variables such as the
inductor current, the derivative of the capacitor voltage, or the current through the
capacitor. The inductor current, which approximates the load current is chosen. The
steady-state turn-off conditions are 0 V and 0 A. The steady-state turn-on conditions
are 12 V and 12 A (point one in the plot). The trajectories to reach these steady state
conditions are shown in state-plane, Figure 2-10.

Figure 2-10: Buck Converter Turn-On and Turn-Off State-Plane

Turn-on

If there were no load, then the normalized turn-on trajectory would trace a clockwise
circle reaching a positive peak current of Vin/Zo = (12 V)/(0.25 ohm) = 48 A, a peak
voltage of twice the input voltage, 2*(12 V) = 24 V, and negative current equal to the
positive current, return to zero volts, and then repeat itself until the circuit is
disturbed, since there is nothing in the circuit that dissipates energy.

Since there is a load to dissipate energy, the circle spirals in to the steady state value
of 12 V and 12 A (point 1) as energy is lost to the load or other dissipative elements as
shown in Figure 2-10.

The state-plane turn-on trajectory tells us some things about this circuit that are
worth remembering. On turn-on, buck-derived converters (and LC filters in general)
tend to overshoot the final voltage, and can have an in-rush current much greater
than the load current. Later in the design cycle it may be necessary to compensate for
these inherent turn-on characteristics by adding soft-start circuits and in-rush
current-limiting circuits to the design.

Also, the turn-on characteristics are dependent on the type of switch. In our ideal
example, the switch can pass the inductor current in either direction, which is true of
a relay contact or a power MOSFET, where the body parasitic diode will conduct
current in the reverse direction. Other switches may not behave this way. For
example, the reverse current behavior of a bipolar transistor depends on the reverse
beta of the transistor and the base drive current. For old alloy junction transistors,
the reverse and forward beta can be the same. For modern planar bipolar transistors,
the reverse beta may be less than one and the transistor can carry only a small
fraction of the forward current in the reverse direction. If the switch can not carry
current in the reverse direction, the voltage rings up to the first peak and stays there
until the load discharges it.

The bottom line is that you have to thoroughly know the behavior of the power
switch to design reliable circuits. Later we will discuss switch topics such as secondary
break-down, Safe Operating Areas (SOA), and parasitic elements that are important
things to know about a switch. Here we see that it can be important to know how a
switch behaves in quadrants other than its normal forward conduction quadrant.

Turn-off

The turn-of trajectory starts at 12 V and 12 A. The inductor keeps supplying 12 V to


the load until it reaches zero amperes. Since the diode does not allow current to go
below zero amperes, the voltage then drops along the zero ampere axis until it reaches
its turn-off steady-state value of zero volts at zero amperes. There is no ringing in the
waveform since the non-linear diode does not allow either voltage or current to go
negative.

Bang-Bang, Ripple, or Hysteresis Control

One easy way to turn our prototype buck converter into a 5 V regulator is to sense the
output and turn the switch on when the voltage is less than 5 V and turn the switch
off when the voltage is greater than 5 V. This form of control is called by various
names including bang-bang control, ripple regulators, and hysteretic control. It is
instructive to exam this operation in the state-plane. For the following plots the
values of L and C are the same (75 uH and 1200 uF) but load is one ohm instead of
0.25 ohm (less damping shows the effects better).

Figure 2-11 shows bang-bang or hysteretic control with no hysteresis. The black line
(1) is output voltage (voltage across the output capacitor) versus time, the blue line is
inductor current (2) versus time, and the green line (3) is inductor current plotted
versus capacitor voltage - the state plane for the two energy storage devices, L and C.
Figure 2-11: Bang-Bang Control - No Hysteresis

At time zero the switch representing the transistor is turned on and the voltage and
current increase until the voltage reaches 5.0V. At this point the switch is turned off
and the current starts to decrease. However, the voltage across the output capacitor
continues to increase as long as current in the inductor is greater than the load
current. The current drops to zero but does not reverse since the switch and diode will
not allow this. When the voltage decays to 5.0V, the switch is turned again and
voltage and current start to increase. This action is repeated with the amplitude of the
voltage ripple and current ripple decreasing each cycle and the frequency increasing
each cycle. In the limit the frequency becomes infinite and the ripple becomes zero
and all that is left is a series dissipative regulator with an LC output filter. In this
example, the initial cycle frequency is about 4.76 kHz, the voltage ripple is 30 mVp-p
and the current ripple is 10Ap-p. This is seen on the state-plane in the outer limit of
the green ellipse at (3). The ellipse is filled in as the ripple goes to zero and the
frequency goes to infinity and we get a series dissipative regulator.

This we do not want. How to we keep things switching? By adding either a time delay
in the control loop (time hysteresis) or voltage hysteresis in the comparator that
senses the output voltage. In practice there is always some time delay in real
components and the regulator may settle into some stable switching frequency.
However, this is not dependable and a controlled delay or voltage hysteresis must be
added.

Figure 2-12 shows the same circuit with a 1.2 microsecond delay added to the control
loop.
Figure 2-12: Bang-Bang Control - Delay Hysteresis

The 1.2 microsecond delay in the feedback loop has stabilized the frequency at about
12.5 kHz with 25 mVp-p voltage ripple and 3 Ap-p current ripple. However, the
overshoot is just as bad as the circuit without hysteresis. (This is shown in the state
plane but not the voltage and current time plots which show the steady state, not the
start-up transient.) How do we cure this? With a soft-start circuit.

Figure 2-13 shows the startup with a soft-start circuit. The soft start is implemented
in this case by slowly bringing up the reference voltage.

Figure 2-13: Bang-Bang Control with Soft Start Circuit


The red line (2) is the 5V reference voltage and ramps up from zero to 5V in 2
milliseconds. The black line (hidden 1) is the output voltage which follows the
reference ramp except every time it makes a comparison to the reference and finds it
is low, it turns on and overshoots the reference. At 2 ms it overshoots the desired 5V
slightly and then after several oscillations settles into the steady state ripple. The
green line (4) shows this action in the inductor-current versus output-voltage state
plane.

Figure 2-14 shows the switching details during steady state conditions. The black line
(1) is the output voltage ripple, the blue line (2) is the ripple current in the inductor,
and the green line (3) is the ripple current versus the ripple voltage in the state-plane.
To this has been a vertical red line added at the 5V switching line.

Figure 2-14: Switching Line Detail

When the upper green trace intercepts the red switching line, the comparator
commands the switch to open. But due to the 1.2 microsecond delay added, the
switching occurs some what later. The same with the lower green trace. This shows
how the time hysteresis controls the output ripple and switching frequency (which is
related in a somewhat complex way to the area traced by the trajectory). Note that
although a time delay is used here, by putting two switching lines at the switch points
(a comparator with voltage hysteresis) the ripple and frequency can be controlled by
voltage hysteresis. Current hysteresis switching lines could also be used. Since all
circuits have delays, the ripple and frequency are usually controlled by time delay and
comparator hysteresis in real circuits. The switching line does not have to be fixed.
For example, one converter uses as reference a fixed frequency triangle derived by
chopping a dc reference and integrating the result into a triangle used as a reference
for the comparator. This gives a fixed frequency of operation combined with the
advantages of fast transient response and 90 degrees phase shift.
The state-plane is a very powerful way to look at switching-mode power supplies. For
example, here we see a steady state response for one set of line and load conditions.
Other sets of line and load conditions have their steady states. The state-plane can be
used to find the optimum switching strategy between the two steady state conditions,
optimum in that there is only one switching point that will allow a transition from
one steady-state to the other steady state with a single off-on switching set. The state-
plane has been used in this manner to determine optimum controllers for switching-
mode power supplies. All modern Spice programs, including the free demonstration
programs, allow plotting the state-plane and provide a powerful tool for examining
switching-mode power supplies. I highly recommend looking at them as part of your
simulation and using them to learn more about switching-mode power supplies. Ask
yourself how does the state-plane change if I change the input voltage? How does it
change if I change the load? What does the transition look like in the state plane for
these changes. One caution is that you usually have to control the maximum step size
to get smooth plots. Using the usual defaults for Spice time plots usually produces
jagged state-plane plots. For the plots in this tutorial, I usually set the maximum step
size to the data step time. This increases the time somewhat needed to complete a
simulation but makes much cleaner state-plane plots.

Bang-bang control is very easy to implement. All circuits have a time delay, so a
simple comparator comparing a reference to the output usually works -- and can
always be made to work by adding an extra time delay. However, control is usually
implemented using a comparator with hysteresis, hence the term hysteretic control.
Whence the name bang-bang? This type of control is often used to control rocket and
satellite control thrusters where a valve is either fully on or fully off. When tested in
the atmosphere, these thrusters make a bang each time the are operated. When a
control system is trying to lock on to a target, these thrusters can sound like the
loudest machine-gun you have every heard. Definitely bang-bang!

Besides simplicity, bang-bang or hysteretic controllers only have 90 degrees phase


shift which makes them easy to stabilize, and a rapid transient response. With these
advantages, why do most power supplies use pulse-width-modulation (PWM) control
instead? A minor reason is that hysteretic converters are more prone to chaos than
other converters. But the major reason is their tendency to synchronize or entrain
with a switching load, a periodic input voltage, or random noise -- often with
unwanted or disastrous results, such as ripple on a five volt logic converter increasing
from a tens of millivolts to several volts. All converters can do this, but bang-bang
controllers are far more susceptible to this problem than PWM controllers.
Entrainment will be discussed in detail in an upcoming problem/solution discussion.