Centrifugal Exhaust Fans

Series C
Roof Upblast and Sidewall

January
2005

Series C Spun Aluminum


Roof Upblast & Sidewall Centrifugal Exhaust Fans
When you buy a Greenheck Series C, you receive a fan with the industrys best performance and durability for
general clean air, high grease, and other contaminant applications (as found in restaurants, food service, and
fume hood exhaust). Both Roof Upblast and Sidewall configurations are specifically designed to discharge air
directly away from the mounting surface.
Broadest performance in the industry, up to 5 in. wg and 30,000 cfm.
Most advanced motor cooling of any fan in its class.
Greenheck pioneered leakproof construction for the entire life of the fan utilizing a onepiece windband that is continuously welded to the curb cap.
Performance as cataloged is assured. All fan sizes are
tested in our AMCA Accredited Laboratory, and all models
are licensed to bear the AMCA sound and air
performance seals.
UL Listed for electrical and grease.
Greenheck subjects these products to
extensive life testing, assuring you that
the fans will provide many years of
reliable performance.

CUE, CUBE, CW, and


CWB models are listed for
electrical (UL/cUL 705)
File no. E40001
CUE, CUBE, CW, and
CWB models are listed
for grease removal
(UL/cUL 762) File no.
MH11745

Greenheck Fan Corporation certifies that the Models


CUE, CUBE, CW and CWB fans shown herein are
licensed to bear the AMCA Seal. The ratings shown are
based on tests and procedures performed in
accordance with AMCA Publication 211 and Publication
311 and comply with the requirements of the AMCA
Certified Ratings Program. The certified ratings for
Models CUE, CUBE, CW, and CWB are shown on
pages 8 to 33.

The Industry Standard


Over the past 40 years, we have listened to your input
and needs to remain the industry leader with the
Series C. This results in:
Specified 2 to 1 over any other fan in its class.
Number 1 in product quality and reliability.
Number 1 in combined reputation and after-sale
service/support.
Over 100 times a day a new Series C fan is put into
service.
Restaurants of all types, schools, and manufacturing
facilities to name a few, turn to the Series C to meet
their requirements.
2

Quick Delivery and Quick Build Programs


You can order from more than 40 Series C configurations, hundreds of in-stock ventilation products,
and accessories that can ship to your job site, in less than 24 hours from our four strategically located
warehouses. Speed up your process even
more, order your units over the Internet
using QD Online at

www.greenheck.com/qd
For other sizes and configurations
where rapid response time is
required, our Quick Build (QB)
Program can manufacture and ship
your custom products in one, three,
five or ten days.

World Class Manufacturing


Our advanced manufacturing processes, superior engineering, and quality control procedures always ensure the
highest product quality. Our skilled production workers use cost-effective machines and unique die designs built by
our own engineers to add innovative features and greater strength to our centrifugal exhaust fans. And just to be sure
you get the peace-of-mind you expect when you specify Greenheck, our assembly inspectors test run and monitor
every fan before it leaves the factory.

Leading Edge Technical Support


When you need extensive product and IOM (Installation and Operating Manual)
information, our products are supported by the industry's best product literature,
electronic media, and computer aided selection program (CAPS). Youll also find this
information on our website at www.greenheck.com
You can always count on personal service and expertise from our national
and international representative organization. To locate your nearest
Greenheck representative, call 715-359-6171 or visit our website at

www.greenheck.com

Roof Upblast and Sidewall - Model Comparison


Performance
Standard Models
CUE & CW Direct Drive
Available in fourteen sizes with nominal wheel
diameters ranging from 9 through 20 inches.
(Sizes 060 through 200)
Capacities range from 70 to 6,400 cfm with static
pressures to 2-1/4 in. wg

CUBE & CWB Belt Drive


Available in fourteen sizes with nominal wheel
diameters ranging from 9 through 48 inches
(Models CUBE-098 through CUBE-480).
Capacities range from 200 through 30,000 cfm with
static pressures to 1.5 in. wg
(Models CWB-098 through CWB-300)
Capacities range from 200 through 12,000 cfm with
static pressures to 1.5 in. wg

High Pressure Models


CUBE-HP & CWB-HP
Belt Drive
Available in nine sizes with nominal wheel
diameters ranging from 10 through 36 inches
(Models CUBE-101HP through CUBE-360HP).
Capacities range from 200 through 17,000 cfm
with static pressures to 2.5 in. wg
(Models CWB-101HP through CWB-300HP).
Capacities range from 200 through 9,000 cfm
with static pressures to 2.5 in. wg

Extended Pressure Models


CUBE-XP
Belt Drive
Available in four sizes with nominal wheel
diameters ranging from 14 through 24
inches
(Models CUBE-161XP, 240XP, 300XP, and
360XP). Capacities range from 700 through
10,700 cfm with static pressures to 5 in. wg

Roof Upblast and Sidewall Construction Features


WHEEL - An aluminum, backward-inclined, nonoverloading centrifugal wheel is utilized to generate high
efficiency and minimal sound. Wheel cones are carefully
matched to the venturi for maximum efficiency. Each
wheel is statically and dynamically balanced for long life
and quiet operation.

DRIVE ASSEMBLY - Belts, pulleys, and keys are oversized


150% of driven horsepower. Machined cast pulleys are
adjustable for final system balancing. Belts are static free
and oil resistant.

10

WINDBAND - One piece, heavy gauge aluminum with a


rolled bead for extra strength directs exhaust air away
from the mounting surface. The curb cap and integral
deep spun venturi are attached to the windband and also
constructed of aluminum to prevent corrosion.

11

LEAKPROOF CONSTRUCTION - The one-piece windband


is continuously welded to the curb cap and drain trough,
for leakproof protection on CUE and CUBE sizes, 98
through 360 and all sizes with UL and CUL-762.

12

BEARINGS - 100% factory tested and designed


specifically for air handling applications with a minimum
(L10) life in excess of 100,000 hours.

CURBCAPS WITH MOUNTING HOLES - Curb cap has


prepunched mounting holes to ensure correct attachment
to the roof. (Roof Upblast only)

13

DRAIN TROUGH - Allows for one-point drainage of water,


grease, and other residues. (Roof Upblast only)

MOTOR - Carefully matched to the fan load and is


mounted out of air stream.

14

MOTOR COVER - Constructed of aluminum and is easily


removed for access to the motor compartment and drive
assembly.

GALVANIZED BIRDSCREEN - Galvanized rigid wire


protects the fans discharge from birds or small objects.
(Standard on Sidewall)

15

MOUNTING PLATE - Allows mounting and sealing to the


wall prior to locating the entire unit. The remainder of the
unit is attached to the mounting plate without locating
and fastening problems associated with mounting a heavy
sidewall unit to a wall. (Sidewall Only)

DISCONNECT SWITCH - Nema-1 switch is factory


mounted and wiring is provided from the motor as
standard (other switches are available). All wiring and
electrical components comply with the National Electric
Codes (NEC) and are either UL listed or recognized.

FAN SHAFT - Is precisely sized, ground, and polished so


the first critical speed is at least 25% over the maximum
operating speed. Where the shaft makes contact with
bearings, close tolerances result in longer bearing life.

MOTOR COOLING - Cooling fins located on top of fan


wheel draw outside air through a large breather tube
directly into the motor compartment. Positive motor
cooling with fresh air results in maximum motor life.

VIBRATION ISOLATION - True vibration isolators are two


independent studs with rubber neoprene which support
the drive assembly and wheel for long life and quiet
operation. (No steel to steel contact)
9

INTERNAL CONDUIT CHASE - For easy internal electrical


wiring in applications not subject to NFPA.
NAME PLATE - Permanent stamped aluminum plate for
exact model and serial identification.
6

10

5
2

7
1

13

15

14
11

12

Options and Accessories


NON STICK WHEEL Patented coating helps
prevent wheel imbalance
in heavy grease
applications and allows
buildup on wheel to be
easily removed. Patent
No. 5,809,993
CLEAN OUT PORT Patented removable plug
allows for easy spray or
steam cleaning of wheel
through the windband.
(Roof Upblast only)
Patent No. 5,809,993
SELF DRAINING GREASE SYSTEM - Drain grease and rain
water back through the ductwork
into the specially designed
Greenheck hood. The hood then
channels grease and rain water
into the restaurant's floor grease
trap.
COATINGS - Wide variety of
coatings and colors are available
for decorative to acidic
applications.
BIRDSCREEN - Galvanized or aluminum rigid wire to
protect the fans discharge from birds or small objects.
(Galvanized is standard on Sidewall)
CURB SEAL - Rubber seal between fan and curb to assure
proper sealing when attached to a curb.
ROOF CURBS - Wide
variety of roof curbs are
available for mounting the
fan to the roof, including:
vented, flanged, pitched,
and sound-absorbing.

HINGE KIT - Allows


maintenance personnel to
hinge the entire fan up to
gain access to wheel and
ductwork for regular
inspection and cleaning.
(Roof Upblast only)

DISCONNECT SWITCHES Assorted Nema rated


switches are available for
positive electrical shutoff
and safety, including: dusttight, rainproof, and
corrosion-resistant.
TIE DOWN POINTS - Four brackets located on the
windband for securing the fan in heavy wind applications.
DAMPERS - Designed to prevent
outside air from entering back
into the building when fan is off.
Includes: backdraft and
motorized dampers.
(N/A w/ UL/cUL 762)
DRAIN CONNECTION Allows for single point
drainage of grease, water
or other residues. (Roof
Upblast only)
GREASE TRAP - Aluminum
trap designed to collect
grease residue to avoid
drainage onto roof surface.
(Roof Upblast only)

VENTED CURB EXTENSION Mounts between roof curb


and roof mounted fans to
meet NFPA requirements of 40
in. minimum discharge above
the roof when mounted on a
minimum 8 in. high roof curb.

GREASE TRAP WITH


ABSORBENT MATERIAL Same as above with an
absorbent material to collect
grease residue for easy
disposal. (Roof Upblast only)

WINDBAND EXTENSION - Aluminum tube that raises fans


discharge an additional 36 in. for special code requirements.

SPEED CONTROLLERS Available for use with shaded pole


and permanent split capacitor
open motors on direct drive fans.
They provide an economical
means of system balancing.

CUE, CUBE, CW, and CWB models


are listed for electrical (UL/cUL 705)
File no. E40001
CUE, CUBE, CW, and CWB models
are listed for grease removal
(UL/cUL 762) File no. MH11745

Typical Installations
Typical Installation - General Clean Air or Fume Hood (Non Grease)
Series C exhaust fans are designed
for applications ranging from clean
air to contaminated air. A typical
installation is shown.

Factory Wired
Motor to
Disconnect

Wall
Damper

Mounting
Bolt Hole
Circle

Recommended
Duct and
Damper Size

Recommended
Wall Opening

Wiring by
Others

8" or 12" in.

Damper

Roof Deck

Wiring by
others

Recommended
Duct and
Damper Size

Factory wired
motor to
disconnect

Recommended
Roof Opening

Typical Installation - Commercial Kitchen (Grease)

Sizes 098 and larger are designed to meet restaurant and food service applications. These fans are UL and cUL Listed for grease
removal and have been tested under high temperature (400 degrees F) and abnormal flare-up (600 degrees F) conditions.
Due to high temperatures and grease-laden air streams in commercial kitchen ventilation, system designers must be aware of
governing codes and guidelines. The National Fire Protection Association (NFPA) is the primary source upon where many codes for
commercial kitchens ventilation are based. Selected information from NFPA is shown below. Local code authorities should be
consulted before proceeding with any kitchen ventilation project.
Exhaust fans used in kitchen ventilation applications must have external wiring. (Wiring must not be installed in air stream.)
Installation must include a means for inspecting, cleaning and servicing the exhaust fan. (e.g. Hinged Curb Cap)
No dampers are to be installed in the system.
Disconnect
factory wired
from motor to
disconnect
through the
breather tube
(Optional)

Wall

Mounting
Bolt Hole
Circle
Recommended
Wall Opening

Minimum 40 in.
Discharge
Height

Grease
Trap

Welded Duct
by others
min. of 18 in.
above roof
deck per
NFPA

Welded Duct
by Others

Vented Curb
Extension

External Wiring
Liquid Tight
Flexible Conduit
by Others

8 in. min.

External Wiring
Liquid Tight
Flexible Conduit
by Others

Roof Deck

Note: Above installations are recommendations based on national


codes. Local authority may supersede these recommendations.

Recommended
Roof Opening

Model Number Code


The Model number system is designed to completely identify the fan. The correct code letters must be specified to designate
belt or direct drive and roof or wall mounted configurations. The remainder of the model number is determined by the size and
performance selected from pages 12 through 35.

UBE - 240

XP

5
Motor HP

C-Series fan
Configuration

4
3
5
7

=
=
=
=

1/4
1/3
1/2
3/4

(Belt Drive only)


10 = 1
30 = 3
15 = 1 1/2 50 = 5
20 = 2
75 = 7 1/2

UBE - Belt Drive Roof Mounted


UE - Direct Drive Roof Mounted

Motor RPM

(Direct Drive only)


D = 1550
E = 1050
G = 1300

W - Direct Drive Wall Mounted

A = 1725
B = 1140
C = 860

Fan Size

Pressure Level

WB - Belt Drive Wall Mounted

060 through 480

(Belt Drive only)


HP - High Pressure Wheel
XP - Extended High Pressure Wheel

Series C

Direct Drive
Exhaust Fans

SIZE 060-095 PERFORMANCE DATA


1050 RPM

Size 060-095 Dimensional Data


CUE
B

C
D

1300 RPM

13/4 in.
A
Dimensional
Data
A
B
C
D
Damper Size
Roof Opening
Unit Weight**

060 - 075
17
1838
1312
1138
8x8
1012 x 1012
29

Model CUE
080 - 090
19
21
1338
1112
10 x 10
1212 x 1212
40

095
19
21
1514
13716
10 x 10
1212 x 1212
40

CW
F

Wall Opening

Mounting Hole Bolt Circle

1550 RPM

Dimensional
Data
E
F
G
Wall Opening
Damper Size
Damper Fr. Size
Mtg. Bolt Circle
Unit Weight**
8

060 - 075
1838
1312
1434
812 x 812
8x8
10 x 10
1134
29

Model CW
080 - 090
21
1338
1778
1012 x 1012
10 x 10
12 x 12
15
40

095
21
1514
1778
1012 x 1012
10 x 10
12 x 12
15
40

All Dimensions are in inches.


** Weight shown is largest cataloged Open Drip Proof motor.

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

ROOF UPBLAST AND SIDEWALL


STANDARD PERFORMANCE
Size 060
DRIVE
DIRECT
CUE
&
CW

MODEL

HP

RPM

060-E

1/200

1050

060-G

1/100

1300

060-D

1/60

1550

1/100

1050

0
Sones BHP
133
1.7
0.006
165
2.8
0.012
197
4.2
0.02

0.10
Sones BHP
94
1.7
0.006
134
2.5
0.012
169
3.9
0.02

STATIC PRESSURE IN INCHES OF W.G.


0.125
0.25
0.375
Sones BHP Sones BHP Sones BHP
81
1.7
0.007
126
70
2.5
0.012
2.5
0.012
164
128
3.9
0.02
4.0
0.021

0.50
0.625
Sones BHP Sones
BHP

Size 065
DIRECT
CUE
&
CW

065-E

180
2.2

126
0.008

1.9

223

065-G

1/60

1300

065-D

1/30

1550

4.7

070-E

1/100

1050

2.6

070-G

1/60

1300

4.0

070-D

1/30

1550

5.5

075-E

1/80

1050

3.4

075-G

1/50

1300

4.0

075-D

1/25

1550

6.0

1/40

1050

3.8

3.2

109
0.009

2.0

0.016

3.1

181
0.015

3.1

266

231
0.026

4.2

0.007

1.6

0.009
170

97
0.017

0.015
172
4.1
0.028

3.9

0.025

152
0.013
269
4.7
0.026

3.9

160
0.022

0.039

185
0.021
291
4.9
0.039

4.8

204
0.035

0.015

4.2

222
0.027

4.2

0.008

1.4

0.028

2.9

95

Size 070
DIRECT
CUE
&
CW

250

193

309

171

267
0.014

3.4

0.023

5.2

0.012

2.8

369

0.008
255

0.015

3.3

0.025

5.1

0.012

2.7

333

0.015
325
0.025

2.4

Size 075
DIRECT
CUE
&
CW

287

210

356

188

294
0.023

3.7

0.039

5.4

0.012

3.7

424

0.012
279

0.023

3.7

0.039

5.3

0.014

3.6

372

0.024
359

3.4

Size 080
DIRECT
CUE
&
CW

080-E

325

265

403

080-G

1/30

1300

5.4

080-D

1/20

1550

7.3

085-E

1/40

1050

4.0

085-G

1/30

1300

5.4

247

356
0.022

5.4

0.037

7.3

0.012

3.9

0.024

5.3

480

0.042

133
0.016
272
5.5
0.031
376
7.2
0.048

0.017

4.3

343
0.025

5.4

0.041

7.3

0.016

3.9

0.027

5.3

441

0.026
431

173
0.031
314
7.3
0.052

7.6

235
0.035
395
7.4
0.058

7.6

391
0.052
604
7.4
0.082

7.4

5.9

235
0.053

Size 085
DIRECT
CUE
&
CW

085-D

389

323

481

430

574

1/20

1550

7.5

090-E

1/40

1050

4.1

090-G

1/25

1300

5.5

090-D

1/15

1550

7.8

095-E

1/30

1050

5.3

095-G

1/12

1300

7.5

095-D

1/8

1550

305

7.4

0.019

3.9

0.035

5.4

0.06

7.6

0.032

4.5

0.061
1049
9.6
0.1

6.8

0.045

0.024

4.2

416

532
0.04

182
0.018
340
5.3
0.034
461
7.4
0.052

0.029
520

0.044

7.4

0.023

3.9

0.041

5.4

0.066

7.6

0.036

4.5

0.066

6.7

5.5

312

161
0.061

8.1

0.087

7.8

0.051

Size 090
DIRECT
CUE
&
CW

549

470

680

451

616

811

0.068

306
0.027
517
5.4
0.048
677
7.5
0.076

0.037

4.5

600

757

0.042
744

5.6

501

347
0.084

Size 095
DIRECT
CUE
&
CW

711

603

880

570

797

774

983
9.3

0.067
964

0.11

9.3

0.11

381
0.037
641
6.4
0.072
861
8.5
0.12

484
0.071
747
8.3
0.12

6.4

199
6.8

0.054
616

8.1

442
0.12

7.8

0.11

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances in the
airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

Series C

Direct Drive
Exhaust Fans

SIZE 098-200 PERFORMANCE DATA


860 RPM

Size 098-200 Dimensional Data


CUE
B

C
D

1140 RPM
13/4 in.
A
Dimensional
Data
A
B
C
D
Damper Size
Roof Opening
Unit Weight**
Max Motor
Frame Size

098 - 131
19
2478
2814
1738
12 x 12
1412 x 1412
64

Model CUE
141 - 161 (HP)
22
2878
2934
1938
16 x 16
1812 x 1812
60

180 - 200
30
3538
2858
21
18 x 18
2012 x 2012
142

56

145T

184T

CW
F

Wall Opening

Mounting Hole Bolt Circle

1725 RPM

Dimensional
Data
E
F
G
Wall Opening
Damper Size
Damper Fr. Size
Mtg. Bolt Circle
Unit Weight**
Max Motor
Frame Size
10

098 - 131
2478
2814
1934
1212 x 1212
12 x 12
14 x 14
1678
64

Model CW
141 - 161 (HP)
2878
2934
2218
1512 x 1512
15 x 15
17 x 17
1938
90

180 - 200
3538
2858
2734
1712 x 1712
17 x 17
19 x 19
25
127

56

145T

184T

All Dimensions are in inches.


** Weight shown is largest cataloged Open Drip Proof motor.

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

ROOF UPBLAST AND SIDEWALL


STANDARD PERFORMANCE
Size 098
DRIVE
DIRECT
CUE
&
CW

MODEL

HP

RPM

098-C

1/8

860

98-B

1/6

1140

98-A

1/4

1725

101-C

1/8

860

101-B

1/6

1140

101-A

1/4

1725

1/8

860

0
Sones BHP
588
8.4
0.02
780
9.1
0.05
1180
13.8
0.18

0.125
Sones BHP
409
8.7
0.02
656
8.7
0.06
1094
13.4
0.18

0.25
Sones BHP
502
0.06
1017
13.0
0.18

STATIC PRESSURE IN INCHES OF W.G.


0.50
0.75
1.00
Sones BHP Sones BHP Sones BHP

1.25
Sones BHP

1.50
Sones BHP

8.3

824
12.2

586
0.20

12.3

0.20

Size 101
DIRECT
CUE
&
CW

732
4.6

625
0.03

2.4

970
7.2

0.07
1468
13.3
0.24

481
0.04

0.6

897

0.04
806

7.0

0.08
1422
12.9
0.26

6.5

0.08
1373
12.5
0.27

1255
11.7
0.29

1129
10.8
0.29

9.7

970
0.29

0.14
1816
17.9
0.44

1710
18.4
0.46

18.7

1571
0.47

18.6

1406
0.48

1176
18.4
0.46

1144
10.3
0.17
2122
18.0
0.56

1994
17.2
0.58

16.4

1838
0.60

15.3

1646
0.60

1365
14.1
0.57

1605
10.3
0.29
2865
24
0.94

1167
10.0
0.27
2711
15.1
0.97

13.4

2539
0.99

14.3

2339
1.00

2085
13.8
0.98

Size 121
DIRECT
CUE
&
CW

121-C
121-B

1/6

1140

121-A

1/2

1725

131-C

1/8

860

131-B

1/6

1140

131-A

3/4

1725

141-C

1/8

860

141-B

1/4

1140

141-A

1725

161-C

1/4

860

161-B

1/2

1140

180-C

1/2

860

180-B

1140

200-C

3/4

860

200-B

1140

1015
0.05
1346
7.4
0.11
2037
15.6
0.39
5.3

905
5.7

781
0.05

5.6

1261
7.9

0.06
1180

0.12

1979
16.1
0.40

8.2

981
0.13

1923
16.7
0.42

8.0

Size 131
DIRECT
CUE
&
CW

1180
0.06
1564
12.5
0.14
2366
18.8
0.50
8.5

1057
8.3

914
0.07

1471
12.2
0.15
2305
18.6
0.51

7.7

0.07
1379
11.8
0.16
2244
18.4
0.53

Size 141
DIRECT
CUE
&
CW

1558
0.11
2065
11.3
0.25
3125
26
0.87

1973
11.3
0.26
3066
23
0.89

2472
10.7
0.22
3277
15.7
0.51

2315
10.2
0.24
3161
15.2
0.55

3035
14.8
0.57

0.24
2745
14.1
0.58

2421
13.5
0.57

12.9

1983
0.55

3249
12.3
0.34
4307
17.6
0.80

3074
11.7
0.37
4173
17.1
0.83

2922
11.1
0.39
4045
16.5
0.86

2474
10.2
0.40
3822
16.1
0.91

3470
15.4
0.93

14.6

3072
0.92

13.6

2477
0.85

4837
15.7
0.71
6412
24
1.65

4587
15.7
0.73
6224
24
1.68

4346
14.6
0.74
6036
23
1.70

3815
12.9
0.75
5674
22
1.74

3084
11.9
0.74
5283
21
1.74

20

4837
1.74

19.2

4276
1.73

3445
19.9
1.63

2.00
Sones BHP

2.25
Sones BHP

2003
1.12

1810
16.6
1.11

7.3

1427
7.5

1264
0.12

7.1

0.12
1864
11.0
0.27
3005
22
0.90

Size 161
DIRECT
CUE
&
CW

2126
9.9

1680
0.25

9.5

Size 180
DIRECT
CUE
&
CW

Size 200
DIRECT
CUE
&
CW

HIGH PRESSURE PERFORMANCE


Size 161HP
DRIVE
DIRECT
CUE
&
CW

MODEL

HP

RPM

161HP-B

1/3

1140

161HP-A

1 2

1725

0.50
Sones BHP
1645
12.5
0.31
2787
22
0.97

0.75
Sones BHP
1444
11.9
0.32
2680
22
1.01

1.00
Sones BHP
1175
11.1
0.32
2560
21
1.04

STATIC PRESSURE IN INCHES OF W.G.


1.25
1.50
1.75
Sones BHP Sones BHP Sones BHP
2439
20

2310
1.07

20

1.10

19.6

2167
1.11

18.3

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances in the
airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

11

Series C

Belt Drive
Exhaust Fans

SIZE 098 PERFORMANCE DATA


STANDARD PERFORMANCE

Size 098/101 Dimensional Data


CUBE
24 7/8

281/4*
173/8

SIZE 101 PERFORMANCE DATA


STANDARD PERFORMANCE

13/4
19
Damper Size = 12 x 12
Roof Opening = 14 1/2 x 14 1/2
Windband Thickness= 0.051
Motor Cover Thickness = 0.040
Curb Cap Metal Thickness = 0.064 Unit Weight**=58 lbs.

CWB

Wall Opening

193/4

Mounting Hole Bolt Circle

28 1/4*

Wall Opening = 12 1/2 x 12 1/2


Damper Size = 12 x 12
Damper Frame Size = 14 x 14
Unit Weight**= 58 lbs.

HIGH PRESSURE PERFORMANCE


247/8

Mtg. Bolt Circle = 16 7/8


Windband Thickness= 0.051
Motor Cover Thickness = 0.040

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

12

ROOF UPBLAST AND SIDEWALL


AVG. DISCHARGE VEL. (FPM) - CFM/1.28
MAX. BHP AT A GIVEN RPM - (RPM/3099)3
TIP SPEED = RPM X 2.846

DRIVE

MODEL

HP

RPM
650
920

BELT
CUBE
&
CWB

1055
098-4

1/4

1190
1325
1460
1595
1725

0
Sones BHP
445
8.1 0.01
629
8.6 0.03
721
8.9 0.04
814
9.5 0.06
906
10.7 0.08
998
12.0 0.11
1091
13.2 0.14
1180
13.8 0.18

0.05
Sones BHP
357
8.5 0.01
567
8.5 0.03
666
8.7 0.04
763
9.3 0.06
860
10.5 0.08
957
11.8 0.11
1053
13.1 0.14
1144
13.6 0.18

0.10
Sones BHP
239
9.9 0.01
505
8.5 0.03
615
8.6 0.04
720
9.1 0.06
820
10.3 0.08
918
11.6 0.11
1016
12.8 0.14
1109
13.5 0.18

MAXIMUM RPM - 1725


MAX. MOTOR FRAME SIZE - 56

STATIC PRESSURE IN INCHES OF W.G.


0.125
0.20
0.25
0.375
0.50
0.625
0.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
468
0.03
587
8.6 0.05
696
9.0 0.06
800
10.2 0.08
901
11.6 0.11
1000
12.8 0.14
1094
13.4 0.18
8.5

339
0.03
485
8.4 0.05
617
8.8 0.07
735
10.2 0.09
845
11.5 0.12
950
12.5 0.14
1049
13.1 0.18
8.8

410
8.4

0.05
553

8.7

373
0.07 8.4

685
10.0 0.09
803
11.5 0.12
914
12.5 0.15
1017
13.0 0.18

0.07
540

353
0.09
679
542
11.2
0.12 11.2 0.12
813
692
12.3
0.16 12.1 0.16
929
824
12.7
0.20 12.2 0.20
9.7

0.09 9.6

560
12.2 0.16
712
586
12.1 0.20 12.3 0.20

ROOF UPBLAST AND SIDEWALL


AVG. DISCHARGE VEL. (FPM) - CFM/1.28
MAX. BHP AT A GIVEN RPM - (RPM/2591)3
TIP SPEED = RPM X 2.913

DRIVE

MODEL

HP

RPM
960
1100

BELT
CUBE
&
CWB

1240
101-4

1/4
1380
1520
1660
1740

101-3

1/3
1820

0
Sones BHP
817
5.6 0.04
936
6.9 0.06
1056
7.9 0.09
1175
9.4 0.12
1294
11.5 0.17
1413
12.7 0.22
1481
13.4 0.25
1549
14.3 0.28

0.125
Sones BHP
724
4.5 0.05
859
6.6 0.07
989
7.9 0.10
1116
9.3 0.14
1241
11.3 0.18
1365
12.3 0.23
1435
13.0 0.26
1505
13.7 0.30

0.25
Sones BHP
611
3.3 0.05
765
6.1 0.08
908
7.5 0.11
1046
9.1 0.14
1181
11.0 0.19
1313
12.0 0.24
1386
12.6 0.27
1459
13.4 0.31

STATIC PRESSURE IN INCHES OF W.G.


0.375
0.50
0.625
0.75
0.875
1.00
1.25
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
657
0.08
821
6.8 0.11
971
8.5 0.15
1113
10.7 0.19
1251
11.6 0.25
1329
12.1 0.28
1406
12.7 0.32
5.7

715
0.11
890
790
7.9 0.15 7.4 0.15
1045
969
878
10.2 0.20 9.5 0.20 9.0 0.20
1189
1125
1056
11.3 0.26 10.8 0.26 10.2 0.26
1270
1210
1146
11.8 0.29 11.4 0.30 10.9 0.30
1350
1293
1234
12.4 0.33 12.0 0.34 11.6 0.35
6.4

AVG. DISCHARGE VEL. (FPM) - CFM/1.28


MAX. BHP AT A GIVEN RPM - (RPM/3195)3
TIP SPEED = RPM X 2.913
DRIVE

MODEL

HP

RPM
1300
1550

101HP-4

1/4
1800

BELT
CUBE
&
CWB

2045
2150
101HP-3

1/3
2250
2415

101HP-5

1/2
2580

0.50
Sones BHP
335
6.0 0.07
497
7.9 0.11
637
10.6 0.18
761
13.9 0.24
812
14.1 0.28
860
14.4 0.32
938
15.1 0.39
1014
16.8 0.48

0.625
Sones BHP
182
6.3 0.06
445
7.6 0.11
595
10.1 0.18
729
13.5 0.26
782
14.1 0.29
832
14.4 0.33
914
15.0 0.39
992
16.4 0.48

MAXIMUM RPM - 1820


MAX. MOTOR FRAME SIZE - 56

717
8.7

0.18
974

9.6
0.26
1079
10.4 0.30
1171
11.2 0.35

861
0.25
991
9.7 0.30
1106
900
10.6 0.35 10.1 0.33
9.4

MAXIMUM RPM - 2580


MAX. MOTOR FRAME SIZE - 56

STATIC PRESSURE IN INCHES OF W.G.


0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
379
0.11
550
9.8 0.18
693
12.7 0.26
752
13.5 0.30
804
14.2 0.34
887
15.0 0.41
969
16.0 0.49
7.3

445
0.18
615
12.1 0.26
678
12.5 0.30
737
13.2 0.35
831
14.5 0.43
919
15.7 0.52
9.3

522
11.5 0.26
600
12.0 0.30
665
12.5 0.35
765
13.7 0.43
861
15.1 0.53

346
11.4 0.23
500
11.5 0.30
579
11.9 0.35
697
12.9 0.43
799
14.4 0.53

456
11.6 0.32
614
498
12.2 0.43 12.0 0.40
735
655
550
323
13.7 0.53 13.2 0.53 12.9 0.49 12.5 0.43

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

13

Series C

Belt Drive
Exhaust Fans

SIZE 121 PERFORMANCE DATA


STANDARD PERFORMANCE

Size 121/131 Dimensional Data


CUBE
24 7/8

281/4*
173/8

13/4
19

SIZE 131 PERFORMANCE DATA

Damper Size = 12 x 12
Roof Opening = 14 1/2 x 14 1/2
Windband Thickness= 0.051
Motor Cover Thickness = 0.040
Curb Cap Metal Thickness = 0.064 Unit Weight**=66 lbs.

STANDARD PERFORMANCE

CWB

Wall Opening

193/4

Mounting Hole Bolt Circle

28 1/4*

Wall Opening = 12 1/2 x 12 1/2


Damper Size = 12 x 12
Damper Frame Size = 14 x 14
Unit Weight**= 66 lbs.

247/8

Mtg. Bolt Circle = 16 7/8


Windband Thickness= 0.051
Motor Cover Thickness = 0.040

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

14

ROOF UPBLAST AND SIDEWALL


AVG. DISCHARGE VEL. (FPM) - CFM/1.28
MAX. BHP AT A GIVEN RPM - (RPM/2199)3
TIP SPEED = RPM X 3.419

DRIVE

MODEL

HP

RPM
685
789
893
997

121-4

1/4
1101

BELT
CUBE
&
CWB

1205
1309
1410
1480
121-3

1/3
1545
1635

121-5

1/2
1725

0
Sones BHP
809
4.4 0.02
932
4.9 0.04
1054
5.5 0.05
1177
6.2 0.08
1300
6.9 0.10
1423
8.2 0.13
1546
9.7 0.17
1665
11.1 0.21
1748
11.9 0.25
1824
12.8 0.28
1931
14.1 0.33
2037
15.6 0.39

0.125
Sones BHP
670
4.4 0.03
812
5.2 0.04
947
5.9 0.06
1081
6.6 0.08
1212
7.4 0.11
1342
8.7 0.14
1470
10.3 0.18
1595
11.6 0.22
1681
12.4 0.26
1760
13.4 0.29
1870
14.7 0.34
1979
16.1 0.40

MAXIMUM RPM - 1725


MAX. MOTOR FRAME SIZE - 56

STATIC PRESSURE IN INCHES OF W.G.


0.25
0.375
0.50
0.625
0.75
1.00
1.25
1.50
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
663
0.05
834
5.9 0.07
989
6.7 0.09
1128
7.7 0.12
1265
9.1 0.15
1399
10.9 0.19
1528
12.2 0.23
1617
13.1 0.27
1699
14.0 0.30
1811
15.2 0.36
1923
16.7 0.42
5.2

666
0.07
865
6.6 0.09
1032
7.7 0.12
1188
9.2 0.16
1329
11.0 0.20
1463
12.5 0.24
1555
13.5 0.28
1639
14.5 0.31
1755
15.9 0.37
1869
17.3 0.43
5.9

682
0.09
909
7.4 0.13
1087
9.1 0.16
1249
11.0 0.21
1398
12.6 0.25
1493
13.7 0.29
1580
14.7 0.32
1699
16.2 0.38
1816
17.9 0.44
6.7

724
0.12
965
9.0 0.16
1153
11.0 0.21
1315
12.7 0.26
1421
13.8 0.30
1518
14.8 0.33
1643
16.4 0.39
1763
18.2 0.45
7.6

790
9.0 0.16
1035
10.9 0.21
1224
12.7 0.26
1338
13.8 0.30
1441
14.9 0.34
1577
16.6 0.40
1710
18.4 0.46

965
12.3 0.25
1132
13.6 0.30
1262
14.9 0.34
1424
16.7 0.41
1571
18.7 0.47

990
14.6 0.33
1226
16.5 0.40
1406
1176
18.6 0.48 18.4 0.46

ROOF UPBLAST AND SIDEWALL


AVG. DISCHARGE VEL. (FPM) - CFM/1.28
MAX. BHP AT A GIVEN RPM - (RPM/2041)3
TIP SPEED = RPM X 3.420

DRIVE

MODEL

HP

RPM
650
743
836
929

131-4

1/4
1022

BELT
CUBE
&
CWB

1115
1208
1305
131-3

1/3

1435
1540

131-5

1/2

1592
1645

0
Sones BHP
892
6.2 0.03
1019
7.1 0.04
1147
8.2 0.06
1274
9.6 0.08
1402
11.1 0.10
1529
12.2 0.13
1657
13.4 0.17
1790
14.6 0.22
1968
15.7 0.29
2112
16.7 0.35
2183
17.3 0.39
2256
17.9 0.43

0.125
Sones BHP
724
6.0 0.03
876
6.9 0.05
1021
8.0 0.06
1161
9.4 0.09
1299
10.8 0.11
1435
11.9 0.14
1570
13.1 0.18
1709
14.3 0.23
1895
15.5 0.30
2044
16.5 0.37
2117
17.0 0.41
2192
17.6 0.45

MAXIMUM RPM - 1645


MAX. MOTOR FRAME SIZE - 56

STATIC PRESSURE IN INCHES OF W.G.


0.25
0.375
0.50
0.625
0.75
0.875
1.00
1.25
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
668
0.05
868
7.4 0.07
1042
8.8 0.09
1193
10.3 0.12
1341
11.5 0.15
1483
12.7 0.19
1629
13.9 0.24
1822
15.1 0.31
1976
16.2 0.38
2052
16.8 0.42
2128
17.4 0.46
6.2

864
8.0 0.09
1060
9.6 0.13
1235
10.9 0.16
1391
12.2 0.20
1547
13.5 0.25
1749
14.8 0.32
1908
16.0 0.39
1986
16.6 0.43
2065
17.2 0.47

869
8.7 0.12
1094
10.0 0.16
1277
11.4 0.21
1458
13.0 0.26
1671
14.3 0.33
1838
15.6 0.41
1920
16.2 0.45
2001
16.9 0.49

886
9.3 0.15
1136
10.6 0.21
1340
12.0 0.26
1586
13.8 0.34
1764
15.2 0.42
1848
15.8 0.46
1933
16.5 0.50

928
10.0 0.19
1201
11.5 0.26
1479
13.1 0.35
1678
14.6 0.43
1774
15.3 0.47
1864
16.1 0.51

1003
10.8 0.24
1358
12.5 0.34
1577
14.0 0.43
1678
14.8 0.47
1778
15.6 0.52

1198
11.9 0.33
1465
13.4 0.43
1578
1301
14.3 0.47 13.0 0.45
1684
1455
15.1 0.52 13.9 0.51

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

15

Series C

Belt Drive
Exhaust Fans

SIZE 141 PERFORMANCE DATA

STANDARD PERFORMANCE

Size 141 Dimensional Data


CUBE
287/8

29 3/4*
193/8

13/4
22
Damper Size = 16 x 16
Roof Opening = 18 1/2 x 18 1/2
Windband Thickness= 0.051
Motor Cover Thickness = 0.040
Curb Cap Metal Thickness = 0.064 Unit Weight**=84 lbs.

HIGH PRESSURE PERFORMANCE

CWB

Wall Opening

221/8

Mounting Hole Bolt Circle

293/4*

Wall Opening = 15 1/2 x 15 1/2


Damper Size = 15 x 15
Damper Frame Size = 17 x 17
Unit Weight**= 84 lbs.

287/8

Mtg. Bolt Circle = 19 3/8


Windband Thickness= 0.051
Motor Cover Thickness = 0.040

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

16

ROOF UPBLAST AND SIDEWALL

AVG. DISCHARGE VEL. (FPM) - CFM/1.72


MAX. BHP AT A GIVEN RPM - (RPM/1726)3
TIP SPEED = RPM X 3.829

DRIVE

MODEL

HP

RPM
590
690
790

141-4

1/4

890
990

BELT
CUBE
&
CWB

1090
1105
141-3

1/3

1210

141-5

1/2

1390

141-7

3/4

1495
1595
141-10

1725

0
Sones BHP
1069
5.0 0.04
1250
5.8 0.06
1431
6.6 0.08
1612
7.7 0.12
1793
8.9 0.16
1974
10.7 0.22
2001
10.9 0.23
2192
12.2 0.30
2518
14.9 0.45
2708
17.2 0.57
2889
20 0.69
3125
26 0.87

0.125
Sones BHP
851
4.5 0.04
1076
5.7 0.06
1285
6.8 0.09
1488
7.8 0.13
1684
9.1 0.17
1877
10.6 0.23
1906
10.8 0.24
2106
12.2 0.31
2445
14.7 0.47
2640
16.5 0.58
2826
19.0 0.70
3066
23 0.89

STATIC PRESSURE IN INCHES OF W.G.


0.25
0.375
0.5
0.75
1.00
1.25
1.50
1.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
805
4.7 0.06
1094
6.1 0.10
1333
7.5 0.14
1552
8.9 0.18
1762
10.5 0.24
1793
10.6 0.25
2006
11.7 0.32
2362
14.2 0.48
2565
16.3 0.60
2757
18.5 0.72
3005
22 0.90

748
5.3 0.09
1130
6.9 0.14
1396
8.5 0.19
1633
10.2 0.25
1667
10.3 0.26
1896
11.6 0.33
2271
13.2 0.50
2483
15.6 0.61
2683
19.5 0.74
2936
24 0.92

1184
8.2 0.18
1476
9.9 0.25
1515
10.0 0.26
1773
11.2 0.34
2174
12.9 0.51
2396
13.9 0.62
2602
16.1 0.75
2865
24 0.94

998
9.6 0.23
1443
10.9 0.34
1949
12.1 0.52
2202
12.5 0.64
2430
13.3 0.77
2711
15.1 0.97

1643
11.0 0.51
1967
12.2 0.65
2225
12.3 0.79
2539
13.4 0.99

AVG. DISCHARGE VEL. (FPM) - CFM/1.72


MAX. BHP AT A GIVEN RPM - (RPM/2285)3
TIP SPEED = RPM X 3.829

DRIVE

MODEL

HP

RPM
895
1010
1125

141HP-4

BELT
CUBE
&
CWB

1/4

1240
1350
1465

141HP-3

1/3

1605
1725

141HP-5

1/2
1845
1960

141HP-7

3/4

2090
2110

0.50
Sones BHP
331
6.1 0.06
528
6.4 0.09
671
8.0 0.12
797
10.2 0.16
906
12.9 0.20
1016
14.2 0.24
1146
15.2 0.31
1256
16.1 0.38
1363
17.0 0.46
1463
18.1 0.54
1575
19.5 0.65
1592
19.8 0.67

MAXIMUM RPM - 1725


MAX. MOTOR FRAME SIZE - 145T

1617
10.8 0.61
1968
1568
12.6 0.78 11.6 0.72
2339
2085
14.3 1.00 13.8 0.98

1704
13.8 0.91

MAXIMUM RPM - 2110


MAX. MOTOR FRAME SIZE - 145T

STATIC PRESSURE IN INCHES OF W.G.


0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

478
0.12
651
9.7 0.16
790
12.3 0.20
920
13.5 0.26
1063
14.4 0.33
1178
15.4 0.40
1292
16.6 0.48
1399
17.7 0.57
1518
19.1 0.68
1536
19.3 0.70
9.3

633
13.2 0.20
798
13.2 0.26
965
14.2 0.34
1098
15.0 0.42
1219
16.2 0.50
1330
17.4 0.59
1454
18.9 0.71
1473
19.1 0.72

642
15.5 0.26
846
14.0 0.34
999
14.9 0.43
1137
16.0 0.52
1260
17.2 0.61
1389
18.7 0.73
1409
19.0 0.75

704
15.2 0.34
879
14.7 0.43
1042
15.9 0.52
1176
17.1 0.62
1320
18.6 0.75
1341
18.9 0.77

747
15.7 0.42
924
15.6 0.52
1086
17.0 0.63
1239
18.5 0.76
1262
18.8 0.78

800
16.1 0.51
970
854
16.8 0.62 16.9
0.62
1154
1045
936
753
18.4 0.76 18.2
0.76 18.0
0.75 22
0.70
1178
1073
965
804
18.6 0.78 18.5
0.78 18.3
0.77 20
0.73

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

17

Series C

Belt Drive
Exhaust Fans

SIZE 161 PERFORMANCE DATA


STANDARD PERFORMANCE

Size 161 Dimensional Data


CUBE
287/8

29 3/4*

HIGH PRESSURE PERFORMANCE

193/8

13/4
22
Damper Size = 16 x 16
Roof Opening = 18 1/2 x 18 1/2
Windband Thickness= 0.051
Motor Cover Thickness = 0.040
Curb Cap Metal Thickness = 0.064 Unit Weight**=87 lbs.

CWB

EXTENDED PRESSURE PERFORMANCE


Wall Opening

221/8

Mounting Hole Bolt Circle

293/4*

Wall Opening = 15 1/2 x 15 1/2


Damper Size = 15 x 15
Damper Frame Size = 17 x 17
Unit Weight**= 85 lbs.

287/8

Mtg. Bolt Circle = 19 3/8


Windband Thickness= 0.051
Motor Cover Thickness = 0.040

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

18

ROOF UPBLAST AND SIDEWALL


AVG. DISCHARGE VEL. (FPM) - CFM/1.72
MAX. BHP AT A GIVEN RPM - (RPM/1365)3
TIP SPEED = RPM X 4.352

DRIVE

MODEL

HP

RPM
730
778

161-4
BELT
CUBE
&
CWB

1/4
826
875

161-3

1/3

965

161-5

1/2

1110

161-7

3/4

1265

161-10

1390

0
Sones BHP
2098
8.1 0.13
2236
8.9 0.16
2374
9.9 0.20
2515
11.0 0.23
2774
12.4 0.31
3191
15.0 0.47
3636
18.5 0.70
3996
22 0.93

0.125
Sones BHP
1905
8.0 0.15
2058
8.7 0.18
2209
9.6 0.22
2362
10.6 0.26
2637
12.0 0.34
3072
14.6 0.51
3532
18.1 0.74
3901
21 0.97

0.25
Sones BHP
1669
7.8 0.15
1843
8.5 0.19
2010
9.3 0.22
2177
10.1 0.26
2477
11.5 0.35
2941
14.2 0.53
3426
17.7 0.78
3806
21 1.02

STATIC PRESSURE IN INCHES OF W.G.


0.375
0.50
0.625
0.75
Sones BHP Sones BHP Sones BHP Sones BHP
1389
7.8 0.15
1596
8.4 0.18
1790
1512
9.1 0.22 9.0 0.21
1974
1744
1365
9.9 0.26 9.7 0.26 9.7 0.24
2300
2109
1893
1584
11.2 0.35 10.8 0.35 10.6 0.34 10.5 0.33
2796
2641
2475
2297
13.8 0.53 13.5 0.54 13.1 0.53 12.9 0.53
3301
3172
3036
2894
17.2 0.78 16.8 0.79 16.5 0.79 16.3 0.79
3698
3584
3464
3340
20 1.03 19.9 1.04 19.6 1.04 19.4 1.05
AVG. DISCHARGE VEL. (FPM) - CFM/1.72
MAX. BHP AT A GIVEN RPM - (RPM/1660)3
TIP SPEED = RPM X 4.352

DRIVE

MODEL

HP

161HP-4

1/4

RPM
825
1065

BELT
CUBE
&
CWB

161HP-3

1/3

161HP-5

1/2

1165
1255
1340

161HP-7

3/4

161HP-10

1535
1610
1690

0.50
Sones BHP
889
7.0 0.12
1487
11.0 0.25
1697
12.8 0.32
1882
13.1 0.40
2053
14.4 0.48
2433
18.1 0.70
2573
19.6 0.80
2722
21 0.92

MODEL

HP

161XP-5

1/2

RPM
1550
1750
1880

BELT
CUBE

161XP-7

3/4
2005

161XP-10

2205
2310

161XP-15

1 - 1/2

2420
2525

1.00
Sones BHP
968
10.0 0.34
1322
12.1 0.52
1515
13.7 0.65
1684
15.0 0.77
1946
17.5 1.01
2076
19.0 1.17
2212
20 1.34
2339
22 1.52

1.00
1.25
1.50
Sones BHP Sones BHP Sones BHP

1770
12.2 0.49
2583
15.8 0.78
3078
19.0 1.04

2163
15.2 0.75
2785
18.6 1.03

2394
18.0 1.00

MAXIMUM RPM - 1690


MAX. MOTOR FRAME SIZE - 145T

STATIC PRESSURE IN INCHES OF W.G.


0.625
0.75
0.875
1.00
1.25
1.50
1.75
2.00
2.25
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1377
10.6 0.26
1608
12.7 0.33
1799
12.8 0.41
1975
13.8 0.49
2368
17.7 0.72
2516
19.2 0.82
2671
21 0.94

1252
10.2 0.26
1504
12.2 0.34
1715
12.5 0.42
1897
13.3 0.50
2301
17.2 0.73
2452
18.8 0.83
2611
21 0.95

1093
9.8 0.26
1395
11.7 0.34
1617
12.0 0.43
1816
12.8 0.51
2233
16.8 0.74
2387
18.4 0.85
2550
20 0.97

1252
11.3 0.34
1519
11.5 0.43
1724
12.3 0.52
2165
16.4 0.76
2322
18.1 0.86
2488
20 0.98

1218
10.6 0.42
1513
11.3 0.52
2015
1855
1638
15.7 0.78 14.9 0.79 13.5 0.78
2190
2037
1863
1651
17.5 0.89 16.9 0.90 15.8 0.91 14.3 0.90
2365
2228
2082
1899
1664
19.5 1.01 19.1 1.03 18.6 1.05 16.9 1.05 15.0 1.03

AVG. DISCHARGE VEL. (FPM) - CFM/1.72


MAX. BHP AT A GIVEN RPM - (RPM/2170)3
TIP SPEED = RPM X 3.534

DRIVE

MAXIMUM RPM - 1390


MAX. MOTOR FRAME SIZE - 145T

MAXIMUM RPM - 2525


MAX. MOTOR FRAME SIZE - 145T

STATIC PRESSURE IN INCHES OF W.G.


1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.25
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1116
11.4 0.49
1359
13.1 0.63
1552
14.7 0.78
1834
17.3 1.03
1974
18.7 1.18
2118
20 1.34
2250
22 1.52

726
10.9 0.43
1139
12.3 0.60
1392
14.1 0.76
1713
17.0 1.04
1865
18.5 1.20
2015
20 1.36
2155
22 1.54

744
12.2 0.52
1161
13.4 0.72
1578
16.4 1.01
1741
18.1 1.18
1908
19.8 1.38
2056
22 1.56

777
13.6 0.63
1395
1127
634
15.9 0.99 15.5 0.92 16.7 0.73
1597
1415
1134
644
17.5 1.16 17.1 1.12 16.8 1.04 18.4 0.83
1785
1637
1451
1179
19.4 1.35 18.9 1.32 18.5 1.28 18.6 1.19
1946
1828
1676
1487
21 1.56 21
1.53 20
1.50 20
1.45

731
0.99
1221
20 1.35

20

22

810
1.16

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

19

Series C

Belt Drive
Exhaust Fans

SIZE 180 PERFORMANCE DATA

STANDARD PERFORMANCE

Size 180 Dimensional Data


CUBE
353/8

285/8*
21

13/4
30
Damper Size = 18 x 18
Roof Opening = 20 1/2 x 20 1/2
Windband Thickness= 0.051
Motor Cover Thickness = 0.040
Curb Cap Metal Thickness = 0.064 Unit Weight**=126 lbs.

HIGH PRESSURE PERFORMANCE


CWB

Wall Opening

273/4

Mounting Hole Bolt Circle

285/8*

Wall Opening = 17 1/2 x 17 1/2


Damper Size = 17 x 17
Damper Frame Size = 19 x 19
Unit Weight**= 126 lbs.

353/8

Mtg. Bolt Circle = 25


Windband Thickness= 0.051
Motor Cover Thickness = 0.040

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

20

ROOF UPBLAST AND SIDEWALL

AVG. DISCHARGE VEL. (FPM) - CFM/2.92


MAX. BHP AT A GIVEN RPM - (RPM/1167)3
TIP SPEED = RPM X 4.843

DRIVE

MODEL

HP

180-4

1/4

RPM
630
745

180-3

1/3

180-5

1/2

820
880

BELT
CUBE
&
CWB

940
1010
180-7

3/4
1075

180-10

180-15

1-1/2

1185
1275
1360
1430

180-20

2
1495

0
Sones BHP
2380
7.1 0.13
2815
9.2 0.22
3098
11.2 0.30
3325
12.7 0.37
3551
13.8 0.45
3816
15.4 0.56
4061
16.5 0.67
4477
18.5 0.90
4817
21 1.12
5138
23 1.36
5402
25 1.58
5648
28 1.80

0.125
Sones BHP
2154
6.4 0.15
2617
8.6 0.24
2916
10.4 0.32
3152
12.2 0.39
3389
13.5 0.47
3664
15.2 0.58
3919
16.2 0.70
4348
17.9 0.93
4697
20 1.15
5026
23 1.39
5296
25 1.62
5546
27 1.84

0.25
Sones BHP
1861
5.5 0.16
2448
8.1 0.26
2759
10.0 0.34
3002
11.7 0.41
3243
13.1 0.49
3526
14.9 0.61
3786
15.8 0.73
4224
17.1 0.96
4578
19.5 1.19
4913
22 1.43
5189
25 1.66
5443
27 1.89

STATIC PRESSURE IN INCHES OF W.G.


0.50
0.75
1.00
1.25
1.50
1.75
2.00
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1763
7.1 0.25
2257
9.0 0.34
2576
10.8 0.43
2879
12.4 0.52
3242
14.7 0.65
3554
15.5 0.78
4005
16.5 1.01
4369
18.7 1.24
4710
21 1.49
4993
24 1.72
5254
26 1.96

1893
9.7 0.39
2363
11.2 0.50
2799
13.7 0.64
3141
14.7 0.78
3703
16.0 1.04
4163
18.2 1.30
4532
21 1.56
4819
23 1.79
5082
25 2.02

2105
11.8 0.58
2652
13.3 0.75
3336
2841
15.2 1.04 14.4 0.99
3799
3437
2930
17.5 1.30 16.7 1.28 15.9 1.22
4232
3912
3537
3023
20 1.58 19.2 1.58 18.3 1.54 17.3 1.46
4593
4270
3968
3567
3001
22 1.83 22
1.83 21 1.83 19.5 1.76 18.2 1.66
4921
4598
4313
3983
3564
25 2.10 24
2.10 23 2.10 22 2.06 21 1.99

AVG. DISCHARGE VEL. (FPM) - CFM/2.92


MAX. BHP AT A GIVEN RPM - (RPM/1315)3
TIP SPEED = RPM X 4.843

DRIVE

MODEL

HP

180HP-4

1/4

RPM
795
845

BELT
CUBE
&
CWB

180HP-3

1/3

925

180HP-5

1/2

1065

180HP-7

3/4

1140
1215
1275
180HP-10

1
1335
1430

180HP-15

1-1/2
1530
1610

180HP-20

2
1685

MAXIMUM RPM - 1495


MAX. MOTOR FRAME SIZE - 184T

MAXIMUM RPM - 1685


MAX. MOTOR FRAME SIZE - 184T

STATIC PRESSURE IN INCHES OF W.G.


0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1570
8.3 0.22
1799
9.5 0.26
2104
1688
10.8 0.34 9.8 0.35
2581
2323
1933
13.8 0.50 12.5 0.52 12.4 0.53
2823
2604
2294
1886
14.4 0.60 13.6 0.64 13.0 0.65 12.8 0.63
3063
2868
2626
2286
1854
15.0 0.72 14.5 0.76 14.0 0.78 13.4 0.79 12.9 0.75
3253
3066
2853
2566
2209
16.7 0.82 15.8 0.87 15.4 0.89 14.9 0.91 14.3 0.89
3441
3261
3075
2839
2523
2156
18.7 0.93 17.4 0.98 17.0 1.02 16.6 1.04 16.1 1.04 15.6 1.01
3735
3566
3401
3206
2964
2669
2320
22 1.13 21 1.19 19.7 1.23 19.3 1.26 18.9 1.27 18.4 1.28 17.9 1.24
4035
3884
3728
3574
3376
3135
2859
2534
24 1.36 23 1.43 22 1.48 21 1.53 20 1.55 19.8 1.56 19.3 1.57 18.6 1.53
4273
4136
3986
3840
3674
3485
3233
2965
2656
25 1.58 24 1.64 23 1.70 23 1.76 22 1.79 21 1.81 21
1.82 20
1.82 19.2 1.78
4495
4369
4226
4085
3945
3768
3575
3325
3061
2766
27 1.79 26 1.86 25 1.93 26 1.99 24 2.04 23 2.07 22
2.08 21
2.09 21
2.08 20 2.04

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

21

Series C

Belt Drive
Exhaust Fans

SIZE 200 PERFORMANCE DATA

STANDARD PERFORMANCE

Size 200 Dimensional Data


CUBE
353/8

285/8*
21

13/4
30
Damper Size = 18 x 18
Roof Opening = 20 1/2 x 20 1/2
Windband Thickness= 0.051
Motor Cover Thickness = 0.040
Curb Cap Metal Thickness = 0.064 Unit Weight**=142 lbs.

HIGH PRESSURE PERFORMANCE


CWB

Wall Opening

273/4

Mounting Hole Bolt Circle

285/8*

Wall Opening = 17 1/2 x 17 1/2


Damper Size = 17 x 17
Damper Frame Size = 19 x 19
Unit Weight**= 127 lbs.

353/8

Mtg. Bolt Circle = 25


Windband Thickness= 0.051
Motor Cover Thickness = 0.040

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

22

ROOF UPBLAST AND SIDEWALL

AVG. DISCHARGE VEL. (FPM) - CFM/2.92 MAXIMUM RPM - 1210


MAX. BHP AT A GIVEN RPM - (RPM/946)3 MAX. MOTOR FRAME SIZE - 184T
TIP SPEED = RPM X 5.595

DRIVE

MODEL

HP

200-4

1/4

RPM
500
605

200-3

1/3

200-5

1/2

665
710

BELT
CUBE
&
CWB

760
820
200-7

3/4
875

200-10

200-15

1-1/2

960
1030
1100
1155

200-20

2
1210

0
Sones BHP
2812
6.2 0.14
3403
8.1 0.25
3740
9.4 0.33
3994
10.6 0.40
4275
12.1 0.49
4612
14.1 0.61
4922
16.3 0.75
5400
18.7 0.98
5793
21 1.22
6187
23 1.48
6496
24 1.72
6806
25 1.97

0.125
Sones BHP
2386
5.4 0.15
3054
7.4 0.26
3422
8.8 0.34
3694
10.1 0.41
3994
11.7 0.51
4350
14.1 0.63
4676
16.3 0.77
5176
18.4 1.01
5585
21 1.24
5992
23 1.51
6311
24 1.74
6628
24 2.00

0.25
Sones BHP
1822
4.6 0.15
2675
6.7 0.26
3096
8.1 0.35
3393
9.3 0.42
3718
10.9 0.52
4098
13.0 0.65
4439
15.2 0.78
4958
17.7 1.03
5380
20 1.26
5798
23 1.53
6125
23 1.77
6451
23 2.03

STATIC PRESSURE IN INCHES OF W.G.


0.375
0.50
0.75
1.00
1.25
1.50
1.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2144
6.1 0.25
2699
7.5 0.35
3050
8.6 0.42
3413
10.1 0.52
3828
12.2 0.65
4192
14.7 0.79
4742
17.0 1.04
5179
19.2 1.28
5610
22 1.55
5946
23 1.79
6279
23 2.05

2073
7.0 0.33
2606
8.1 0.42
3048
9.4 0.51
3523
11.4 0.65
3922
13.5 0.79
4508
16.4 1.04
4968
18.7 1.29
5421
21 1.57
5767
22 1.81
6108
22 2.07

2606
10.7 0.61
3240
12.4 0.78
3985
3169
15.0 1.04 14.4 1.00
4503
3917
17.5 1.29 16.4 1.27
5006
4529
20 1.57 19.3 1.57
5383
4948
21 1.81 20 1.81
5748
5350
21 2.09 21 2.09

AVG. DISCHARGE VEL. (FPM) - CFM/2.92


MAX. BHP AT A GIVEN RPM - (RPM/1093)3
TIP SPEED = RPM X 5.595

DRIVE

MODEL

HP

200HP-5

1/2

RPM
740
880
945

200HP-7

3/4
1010

BELT
CUBE
&
CWB

200HP-10

200HP-15

1-1/2

1110
1190
1270
1335

200HP-20

2
1400
1465

BELT
CUBE

200HP-30

1535
1600

0.50
Sones BHP
2024
8.1 0.31
2779
10.5 0.51
3094
12.2 0.62
3397
14.5 0.75
3851
16.9 0.98
4207
19.0 1.20
4558
22 1.44
4837
23 1.67
5110
24 1.91
5382
26 2.18
5674
27 2.50
5943
29 2.81

2972
16.8 1.18
3861
18.6 1.53
4410
3629
19.2 1.80 19.9 1.71
4892
4289
19.8 2.08 19.7 2.04

3365
21 1.88

MAXIMUM RPM - 1600 (CUBE)


MAXIMUM RPM - 1400 (CWB)
MAX. MOTOR FRAME SIZE - 184T

STATIC PRESSURE IN INCHES OF W.G.


0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2317
9.5 0.52
2711
11.5 0.64
3067
13.7 0.78
3561
16.2 1.02
3944
18.1 1.24
4312
21 1.49
4606
23 1.71
4898
24 1.96
5186
25 2.23
5494
27 2.55
5775
28 2.88

2092
10.6 0.62
2637
13.2 0.79
3242
2806
15.7 1.04 15.5 1.04
3661
3321
17.5 1.27 17.3 1.29
4055
3789
20 1.53 19.7 1.56
4369
4116
22 1.76 21 1.79
4674
4436
24 2.01 23 2.05
4972
4752
25 2.28 25 2.33
5290
5085
27 2.61 27 2.66
5581
5385
29 2.93 30 2.99

2850
17.5 1.26
3433
2944
19.3 1.56 19.8 1.53
3826
3482
21 1.82 21 1.82
4195
3880
21 2.09 22 2.09
4521
4269
23 2.37 23 2.40
4867
4646
25 2.70 23 2.74
5182
4971
29 3.03 26 3.08

2946
22 1.75
3515
23 2.08
3956
24 2.40
4379
24 2.76
4760
24 3.13

3556
25 2.37
4080
26 2.76
4476
26 3.13

3668
28
2.71
4189
28
3.13

3760
31 3.06

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

23

Series C

Belt Drive
Exhaust Fans

SIZE 220 PERFORMANCE DATA

STANDARD PERFORMANCE

Size 220 Dimensional Data


CUBE
423/4

337/8*
251/2

13/4
34
Damper Size = 24 x 24
Roof Opening = 26 1/2 x 26 1/2
Windband Thickness= 0.064
Motor Cover Thickness = 0.051
Curb Cap Metal Thickness = 0.064 Unit Weight**=174 lbs.

HIGH PRESSURE PERFORMANCE


CWB

Wall Opening

311/4

Mounting Hole Bolt Circle

337/8*

Wall Opening = 20 1/2 x 20 1/2


Damper Size = 20 x 20
Damper Frame Size = 22 x 22
Unit Weight**= 159 lbs.

4225/32

Mtg. Bolt Circle = 28 3/8


Windband Thickness= 0.064
Motor Cover Thickness = 0.051

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

24

ROOF UPBLAST AND SIDEWALL

AVG. DISCHARGE VEL. (FPM) - CFM/3.76 MAXIMUM RPM - 955


MAX. BHP AT A GIVEN RPM - (RPM/743)3 MAX. MOTOR FRAME SIZE - 184T
TIP SPEED = RPM X 6.413

DRIVE

MODEL

HP

220-4

1/4

RPM
450
475

BELT
CUBE
&
CWB

220-3

1/3

520

220-5

1/2

600

220-7

3/4

645
685
720
220-10

1
755
810

220-15

1-1/2
865
910

220-20

2
955

0
Sones BHP
3585
7.3 0.19
3784
7.9 0.23
4142
9.3 0.30
4779
12.0 0.46
5138
13.4 0.57
5457
14.8 0.68
5735
16.0 0.79
6014
17.3 0.91
6452
18.7 1.13
6890
20 1.37
7249
23 1.60
7607
25 1.85

0.125
Sones BHP
3155
6.6 0.21
3377
7.2 0.25
3771
8.4 0.32
4457
11.0 0.48
4838
12.6 0.60
5174
14.0 0.71
5466
15.4 0.82
5758
16.7 0.94
6213
18.1 1.16
6667
19.9 1.41
7036
22 1.64
7405
25 1.89

0.25
Sones BHP
2624
6.0 0.22
2896
6.5 0.26
3357
7.6 0.34
4124
10.0 0.51
4539
11.8 0.63
4893
13.4 0.74
5199
14.8 0.86
5502
16.3 0.98
5975
17.7 1.20
6443
19.3 1.45
6823
22 1.68
7202
24 1.93

STATIC PRESSURE IN INCHES OF W.G.


0.375
0.50
0.625
0.75
1.00
1.25
1.50
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2268
6.1 0.25
2845
7.1 0.34
3736
9.3 0.52
4194
11.1 0.64
4581
12.9 0.76
4912
14.4 0.88
5239
16.0 1.01
5737
17.3 1.24
6220
18.9 1.49
6612
21 1.72
7000
24 1.97

3279
8.8 0.52
3811
10.4 0.65
4234
12.1 0.78
4592
13.8 0.90
4944
15.5 1.03
5470
16.9 1.26
5987
18.5 1.52
6400
21 1.76
6799
23 2.02

3346
9.9 0.64
3836
11.6 0.78
4248
13.2 0.91
4620
14.8 1.04
5185
16.2 1.28
5729
17.8 1.54
6158
19.9 1.78
6580
23
2.05

3383
11.1 0.77
3837
12.7 0.90
4258
14.3 1.04
4883
4156
15.6 1.29 14.7 1.27
5453
4835
4111
17.2 1.56 16.3 1.57 15.9 1.53
5909
5365
4704
19.1 1.81 18.0 1.83 17.1 1.81
6347
5844
5261
4602
22
2.07 20
2.11 19.0 2.11 18.6 2.07

AVG. DISCHARGE VEL. (FPM) - CFM/3.76


MAX. BHP AT A GIVEN RPM - (RPM/847)3
TIP SPEED = RPM X 6.413

DRIVE

MODEL

HP

220HP-5

1/2

RPM
650
680
735

220HP-7

3/4
780

BELT
CUBE
&
CWB

220HP-10

220HP-15

1-1/2

860
920
985

220HP-20

1035
1085

BELT
CUBE

1135
220HP-30

1190
1240

0.50
Sones BHP
2909
8.6 0.45
3151
9.6 0.51
3582
11.7 0.63
3902
13.2 0.74
4459
14.8 0.96
4860
16.6 1.16
5281
18.8 1.39
5602
21 1.60
5920
23 1.82
6236
24 2.06
6582
25 2.35
6895
26 2.64

0.75
Sones BHP
1940
7.5 0.42
2405
8.6 0.51
3006
10.8 0.65
3427
12.2 0.78
4075
14.1 1.02
4529
15.6 1.23
4988
17.6 1.48
5335
19.5 1.69
5678
21 1.92
6006
23 2.17
6363
24 2.47
6684
25 2.76

MAXIMUM RPM - 1240 (CUBE)


MAXIMUM RPM - 1085 (CWB)
MAX. MOTOR FRAME SIZE - 184T

STATIC PRESSURE IN INCHES OF W.G.


1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

2716
11.9 0.77
3578
13.7 1.05
4121
15.4 1.27
4642
17.2 1.54
5033
18.6 1.77
5390
20 2.00
5743
22 2.26
6125
24 2.57
6469
25 2.88

2863
12.9 1.01
3593
14.9 1.28
4220
16.9 1.57
4659
18.5 1.81
5061
20 2.06
5456
21 2.34
5863
23 2.66
6217
25 2.97

2756
13.6 1.20
3674
2825
16.2 1.56 14.6 1.46
4209
3630
18.1 1.82 17.0 1.79
4679
4210
3573
19.8 2.10 19.3 2.09 17.8 2.03
5114
4708
4215
3518
21 2.39 21 2.40 20
2.38 19.4 2.28
5556
5221
4811
4309
23 2.72 22 2.77 22
2.77 22
2.73
5950
5637
5283
4885
25 3.05 24 3.10 23
3.13 24
3.13

3598
2.61
4374
25
3.08
22

27

3633
2.92

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

25

Series C

Belt Drive
Exhaust Fans

SIZE 240 PERFORMANCE DATA


STANDARD PERFORMANCE

Size 240 Dimensional Data


CUBE
423/4

337/8*
251/2

HIGH PRESSURE PERFORMANCE

13/4
34
Damper Size = 24 x 24
Roof Opening = 26 1/2 x 26 1/2
Windband Thickness= 0.064
Motor Cover Thickness = 0.051
Curb Cap Metal Thickness = 0.064 Unit Weight**=175 lbs.

CWB

Wall Opening

311/4

Mounting Hole Bolt Circle

337/8*

Wall Opening = 20 1/2 x 20 1/2


Damper Size = 20 x 20
Damper Frame Size = 22 x 22
Unit Weight**= 160 lbs.

EXTENDED PRESSURE PERFORMANCE


4225/32

Mtg. Bolt Circle = 28 3/8


Windband Thickness= 0.064
Motor Cover Thickness = 0.051

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

26

ROOF UPBLAST AND SIDEWALL


AVG. DISCHARGE VEL. (FPM) - CFM/3.76 MAXIMUM RPM - 930
MAX. BHP AT A GIVEN RPM - (RPM/725)3 MAX. MOTOR FRAME SIZE - 184T
TIP SPEED = RPM X 6.413

DRIVE

MODEL

HP

240-4

1/4

RPM
410
465

BELT
CUBE
&
CWB

240-3

1/3

510

240-5

1/2

585

240-7

3/4

670

240-10

735

240-15

1-1/2

845

240-20

930

0
Sones BHP
3717
6.4 0.16
4216
7.6 0.23
4623
8.9 0.31
5303
11.5 0.46
6074
14.3 0.69
6663
16.6 0.92
7660
19.6 1.39
8431
24 1.86

0.125
Sones BHP
3170
5.8 0.18
3768
7.0 0.25
4243
8.1 0.33
4961
10.5 0.49
5763
13.4 0.74
6370
15.9 0.97
7400
19.0 1.46
8194
23 1.93

0.25
Sones BHP
2471
5.3 0.18
3188
6.3 0.26
3717
7.3 0.34
4540
9.5 0.51
5461
12.8 0.76
6133
15.5 0.99
7184
18.6 1.49
7985
23 1.98

STATIC PRESSURE IN INCHES OF W.G.


0.375
0.50
0.625
0.75
1.00
1.25
1.50
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2162
5.9 0.23
3134
6.9 0.34
4093
8.8 0.52
5052
12.2 0.78
5764
15.1 1.01
6947
18.2 1.51
7798
22 2.00

3565
8.4 0.51
4659
4202
11.5 0.79 11.0 0.78
5409
5037
14.6 1.03 13.9 1.04
6615
6304
17.6 1.54 17.0 1.56
7536
7233
22 2.03 21 2.06

3524
10.6 0.73
4618
13.4 1.03
6002
16.4 1.57
6953
19.9 2.08

AVG. DISCHARGE VEL. (FPM) - CFM/3.76


MAX. BHP AT A GIVEN RPM - (RPM/837)3
TIP SPEED = RPM X 6.413

DRIVE

MODEL

HP

240HP-5

1/2

RPM
635
675

BELT
CUBE
&
CWB

BELT
CUBE

240HP-7

3/4

775

240HP-10

850

240HP-15

1-1/2

975

240HP-20

1070

240HP-30

1150
1230

0.50
Sones BHP
3046
8.1 0.43
3405
9.4 0.51
4233
13.1 0.75
4812
14.5 0.96
5737
18.4 1.39
6404
22 1.80
6960
24 2.21
7513
26 2.68

0.625
Sones BHP
2673
7.4 0.43
3070
8.8 0.52
3979
12.5 0.77
4599
14.0 0.99
5567
17.9 1.43
6272
22 1.84
6836
24 2.26
7395
25 2.73

MODEL

HP

240XP-5

1/2

RPM
1100
1195

BELT
CUBE

240XP-7

3/4

1365

240XP-10

1500

240XP-15

1 - 1/2

1720

240XP-20

1895

240XP-30

2030
2165

1.00
Sones BHP
1292
10.9 0.40
1613
11.6 0.53
2079
13.6 0.77
2424
15.9 1.00
2939
21 1.48
3333
24 1.94
3632
26 2.37
3927
29 2.85

1.25
Sones BHP
789
11.9 0.34
1321
12.1 0.51
1886
13.4 0.78
2256
15.3 1.03
2815
19.8 1.51
3222
23 1.98
3529
25 2.40
3830
28 2.89

MAXIMUM RPM - 1230 (CUBE)


MAXIMUM RPM - 1070 (CWB)
MAX. MOTOR FRAME SIZE - 184T

STATIC PRESSURE IN INCHES OF W.G.


0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2607
8.4 0.51
3704
12.1 0.78
4367
13.8 1.01
5387
17.3 1.48
6112
21 1.89
6711
23 2.30
7280
25 2.77

2940
11.8 0.77
3846
13.4 1.04
4988
16.9 1.53
5775
19.7 1.98
6406
22 2.40
7016
25 2.88

3025
12.6 1.00
4539
4006
16.6 1.56 15.9 1.56
5407
4990
19.7 2.04 19.4 2.07
6077
5735
22 2.48 22 2.55
6730
6410
25 2.98 24 3.05

4550
3625
18.8 2.08 16.6 1.95
5335
4925
21
2.57 21 2.58
6090
5709
24
3.13 23 3.14

AVG. DISCHARGE VEL. (FPM) - CFM/3.76


MAX. BHP AT A GIVEN RPM - (RPM/1478)3
TIP SPEED = RPM X 4.778

DRIVE

5282
15.4 1.56
6375
5706
4324
18.7 2.10 17.8 2.07 17.9 1.83

4212
20 2.49
5326
23 3.16

4722
25 3.09

MAXIMUM RPM - 2165


MAX. MOTOR FRAME SIZE - 184T

STATIC PRESSURE IN INCHES OF W.G.


1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
792
13.4 0.43
1645
13.7 0.77
2079
1630
15.1 1.04 15.5 1.01
2671
2366
19.2 1.53 18.4 1.57
3109
2847
22 2.01 21 2.07
3423
3197
25 2.44 24 2.51
3733
3535
28 2.93 27 3.01

1975
18.4 1.53
2566
21 2.10
2945
23 2.56
3305
26 3.07

1336
20 1.35
2202
21 2.05
2667
23 2.58
3063
25 3.12

1706
22 1.92
2319
23 2.51
2787
25 3.11

1852
25 2.38
2461
25 3.05

2048
27 2.93

1324
31 2.47

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

27

Series C

Belt Drive
Exhaust Fans

SIZE 300 PERFORMANCE DATA


STANDARD PERFORMANCE

Size 300 Dimensional Data


CUBE
50

36*

HIGH PRESSURE PERFORMANCE

29

1 3 /4
40
Damper Size = 30 x 30
Roof Opening = 32 1/2 x 32 1/2
Windband Thickness= 0.064
Motor Cover Thickness = 0.051
Curb Cap Metal Thickness = 0.064 Unit Weight**=313 lbs.

CWB

EXTENDED PRESSURE PERFORMANCE


Wall Opening

383/8

Mounting Hole Bolt Circle

36*

Wall Opening = 25 1/2 x 25 1/2


Damper Size = 25 x 25
Damper Frame Size = 27 x 27
Unit Weight**= 298 lbs.

50

Mtg. Bolt Circle = 35 27/32


Windband Thickness= 0.064
Motor Cover Thickness = 0.051

All Dimensions are in inches.


*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

28

ROOF UPBLAST AND SIDEWALL


AVG. DISCHARGE VEL. (FPM) - CFM/5.50
MAX. BHP AT A GIVEN RPM - (RPM/522)3
TIP SPEED = RPM X 7.983
DRIVE

MODEL

HP

300-3

1/3

RPM
355
365

BELT
CUBE
&
CWB

BELT
CUBE

300-5

1/2

420

300-7

3/4

480

300-10

530

300-15

1-1/2

605

300-20

665

300-30

765

300-50

905

0
Sones BHP
5777
6.9 0.27
5939
7.2 0.29
6835
9.0 0.45
7811
11.0 0.67
8625
13.3 0.90
9845
17.0 1.34
10822
20 1.77
12449
24 2.70
14727
32 4.47

0.125
Sones BHP
5132
6.3 0.30
5316
6.5 0.33
6314
8.2 0.49
7377
10.5 0.72
8231
12.7 0.95
9501
16.4 1.40
10508
19.7 1.85
12176
24 2.78
14497
32 4.57

0.25
Sones BHP
4227
5.3 0.31
4463
5.7 0.34
5660
7.5 0.52
6844
9.9 0.76
7772
12.2 1.00
9127
15.7 1.46
10193
18.6 1.92
11904
23 2.86
14266
32 4.67

STATIC PRESSURE IN INCHES OF W.G.


0.50
0.75
1.00
1.25
1.50
1.75
2.00
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

5440
8.5 0.77
6636
11.2 1.05
8226
14.8 1.54
9411
17.5 2.02
11273
22 3.00
13788
29 4.85

7084
13.5 1.55
8495
7271
16.7 2.07 15.1 2.04
10554
9743
8756
7352
21 3.09 20 3.15 18.7 3.14 17.0 2.98
13223
12614
11963
11191
28 5.00 28 5.11 27 5.19 26 5.21

AVG. DISCHARGE VEL. (FPM) - CFM/5.5


MAX. BHP AT A GIVEN RPM - (RPM/602)3
TIP SPEED = RPM X 7.983

DRIVE

MODEL

HP

300HP-5

1/2

RPM
460
485

BELT
CUBE
&
CWB

BELT
CUBE

300HP-7

3/4

555

300HP-10

610

300HP-15

1-1/2

700

300HP-20

770

300HP-30

885

300HP-50

1045

0.50
Sones BHP
3125
7.3 0.44
3639
7.9 0.52
4788
10.4 0.77
5549
12.4 1.00
6741
16.0 1.47
7613
18.6 1.91
9014
23 2.83
10909
35 4.54

MODEL

HP

300XP-7

3/4

RPM
790
900

BELT
CUBE

300XP-10

990

300XP-15

1 - 1/2

1130

300XP-20

1245

300XP-30

1425

300XP-50

1560
1690

1.00
Sones BHP
1776
9.4 0.48
2958
12.2 0.79
3619
14.6 1.04
4511
18.9 1.48
5182
22 1.92
6199
27 2.78
6941
31 3.57
7643
36 4.47

10357
24 5.20

22

9178
5.01

MAXIMUM RPM - 1045 (CUBE)


MAXIMUM RPM - 885 (CWB)
MAX. MOTOR FRAME SIZE - 213T

STATIC PRESSURE IN INCHES OF W.G.


0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

3651
9.9 0.76
4731
11.3 1.03
6149
15.2 1.53
7107
18.1 2.00
8603
23 2.94
10570
34 4.68

5390
14.0 1.57
6535
5814
17.4 2.06 16.2 2.09
8150
7678
23 3.03 22 3.12
10222
9855
34 4.82 33 4.94

4684
16.0 1.99
7062
21 3.15
9455
32 5.04

6353
21 3.14
9054
31 5.13

8533
31 5.17

AVG. DISCHARGE VEL. (FPM) - CFM/5.5


MAX. BHP AT A GIVEN RPM - (RPM/972)3
TIP SPEED = RPM X 5.825

DRIVE

MAXIMUM RPM - 905 (CUBE)


MAXIMUM RPM - 765 (CWB)
MAX. MOTOR FRAME SIZE - 213T

8002
30
5.21

7330
28 5.15

6463
27 4.99

MAXIMUM RPM - 1690


MAX. MOTOR FRAME SIZE - 213T

STATIC PRESSURE IN INCHES OF W.G.


1.25
1.50
2.00
2.50
3.00
3.50
4.00
4.50
4.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2273
11.3 0.75
3167
13.4 1.05
4201
17.8 1.53
4930
21 1.99
5983
26 2.86
6746
30 3.67
7464
35 4.57

2538
12.8 1.00
3833
2773
16.8 1.56 15.6 1.46
4648
3943
20 2.04 18.6 2.08
5768
5286
25 2.95 24 3.07
6549
6143
30 3.76 28 3.93
7284
6920
34 4.68 33 4.87

2705
17.9 1.86
4695
22 3.14
5684
27 4.05
6528
31 5.04

3886
21 3.03
5134
25 4.12
6091
30 5.16

4441
24 4.02
5587
29 5.24

3049
24 3.50
4951
28 5.14

4100
28 4.88

28

3070
4.32

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

29

Series C

Belt Drive
Exhaust Fans

SIZE 360 PERFORMANCE DATA


STANDARD PERFORMANCE

Size 360 Dimensional Data

CUBE
58 5 /8

HIGH PRESSURE PERFORMANCE


39 1 /8*
29 3 /8

1 3 /4
46
Damper Size = 36 x 36
Roof Opening = 38 1/2 x 38 1/2
Windband Thickness= 0.080
Motor Cover Thickness = 0.064
Curb Cap Metal Thickness = 0.080 Unit Weight**= 440 lbs.
All Dimensions are in inches.
*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

EXTENDED PRESSURE PERFORMANCE

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

30

ROOF UPBLAST
AVG. DISCHARGE VEL. (FPM) - CFM/7.25 MAXIMUM RPM - 690
MAX. BHP AT A GIVEN RPM - (RPM/396)3 MAX. MOTOR FRAME SIZE - 213T
TIP SPEED = RPM X 9.425

DRIVE

MODEL

HP

360-5

1/2

RPM
300
320

BELT
CUBE

360-7

3/4

365

360-10

400

360-15

1-1/2

460

360-20

505

360-30

580

360-50

690

0
0.125
Sones BHP Sones BHP
8092
7206
6.9 0.37 5.9 0.42
8631
7820
7.7 0.44 6.8 0.50
9845
9142
10.2 0.66 9.4 0.72
10789
10153
12.7 0.87 11.9 0.94
12408
11862
16.8 1.32 16.5 1.40
13621
13125
20 1.74 20 1.83
15644
15212
23 2.64 23 2.74
18611
18248
30 4.44 29 4.57

0.25
Sones BHP
6023
5.4 0.43
6755
6.0 0.52
8299
8.5 0.77
9426
11.1 0.99
11281
15.8 1.48
12602
19.8 1.92
14769
23 2.84
17884
28 4.69

STATIC PRESSURE IN INCHES OF W.G.


0.375
0.50
0.75
1.00
1.25
1.50
1.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
5256
6.6 0.51
7286
8.0 0.78
8556
10.3 1.02
10587
15.1 1.53
12022
19.0 1.99
14306
22 2.94
17504
28 4.81

5767
8.3 0.74
7575
9.9 1.02
9814
7809
14.5 1.55 13.5 1.52
11359
9878
18.6 2.04 17.9 2.06
13783
12597
22 3.02 21 3.10
17115
16236
28 4.93 27 5.11

11287
9381
20
3.13 18.4 3.02
15243
14187
25
5.21 24 5.26

12985
23 5.25

11290
22 5.09

AVG. DISCHARGE VEL. (FPM) - CFM/7.25 MAXIMUM RPM - 865


MAX. BHP AT A GIVEN RPM - (RPM/434)3 MAX. MOTOR FRAME SIZE - 213T
TIP SPEED = RPM X 9.425

DRIVE

MODEL

HP

360HP-10

RPM
420
440

BELT
CUBE

360HP-15

1-1/2

505

360HP-20

555

360HP-30

635

360HP-50

695
755
360HP-75

7.5

865

0.50
Sones BHP
6407
9.6 0.90
7003
10.8 1.03
8765
15.3 1.52
10029
17.2 1.97
11934
21 2.87
13321
24 3.70
14688
28 4.68
17129
33 6.89

STATIC PRESSURE IN INCHES OF W.G.


0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

7539
14.3 1.57
9046
16.2 2.06
11157
19.5 3.00
12662
23 3.86
14086
27 4.86
16631
32 7.11

7766
15.4 2.08
10276
9171
18.2 3.09 17.8 3.12
11902
11053
22 3.98 20 4.07
13434
12734
26 5.01 25 5.14
16105
15544
30 7.32 29 7.50

7329
17.3 2.95
10026
8393
20 4.09 19.6 3.92
11922
10973
24 5.23 23 5.24
14933
14315
29 7.64 29 7.79

9593
22 5.10
13565
28 7.87

12738
27 7.89

11789
25 7.83

10197
23 7.50

AVG. DISCHARGE VEL. (FPM) - CFM/7.25 MAXIMUM RPM - 1490


MAX. BHP AT A GIVEN RPM - (RPM/748)3 MAX. MOTOR FRAME SIZE - 213T
TIP SPEED = RPM X 7.069

DRIVE

MODEL

HP

360XP-10

RPM
700
760

BELT
CUBE

360XP-15

1 - 1/2

870

360XP-20

955

360XP-30

1095

360XP-50

1300

360XP-75

7 - 1/2

1395
1490

1.00
Sones BHP
3210
10.5 0.81
4020
11.1 1.05
5243
13.6 1.53
6081
15.4 1.97
7351
19.2 2.85
9113
26 4.54
9910
29 5.50
10699
33 6.61

STATIC PRESSURE IN INCHES OF W.G.


1.25
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
3225
11.1 1.01
4740
12.7 1.57
5679
15.4 2.04
7050
18.4 2.95
8881
25 4.69
9693
28 5.67
10496
32 6.78

4112
12.3 1.55
5216
3949
14.2 2.08 13.0 1.98
6724
5930
17.8 3.03 16.4 3.13
8635
8125
24 4.82 23 5.04
9477
9009
27 5.83 26 6.08
10294
9871
31 6.96 30 7.27

4905
15.4 3.07
7502
22 5.21
8490
25 6.30
9429
29 7.52

6764
21 5.24
7905
24 6.48
8907
27 7.73

5867
20
5.15
7193
23
6.48
8340
26
7.89

4286
4.52
6348
23
6.37
7673
26
7.90
20

5143
23 5.87
6881
26 7.78

27

5830
7.34

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

31

Series C

Belt Drive
Exhaust Fans

SIZE 420 PERFORMANCE DATA


STANDARD PERFORMANCE

Size 420 Dimensional Data


CUBE
65 3 /8

44 3 /4*
35 1 /4

1 3 /4
52
Damper Size = 42 x 42
Roof Opening = 44 1/2 x 44 1/2
Windband Thickness= 0.080
Motor Cover Thickness = 0.064
Curb Cap Metal Thickness = 0.100 Unit Weight**= 578 lbs.

Size 480 Dimensional Data

SIZE 480 PERFORMANCE DATA


STANDARD PERFORMANCE

CUBE
743/16

481/8*
36

13/4
58
Damper Size = 48 x 48
Roof Opening = 50 1/2 x 50 1/2
Windband Thickness= 0.080
Motor Cover Thickness = 0.064
Curb Cap Metal Thickness = 0.100 Unit Weight**= 675 lbs.
All Dimensions are in inches.
*May be greater depending on motor
**Weight shown is largest cataloged Open Drip Proof Motor

Performance shown is for installation type A: Free inlet, Free outlet. Performance ratings do not
include the effects of appurtenances in the airstream.

32

ROOF UPBLAST
AVG. DISCHARGE VEL. (FPM) - CFM/8.99 MAXIMUM RPM - 600
MAX. BHP AT A GIVEN RPM - (RPM/303)3 MAX. MOTOR FRAME SIZE - 213T
TIP SPEED = RPM X 11.06

DRIVE

MODEL

HP

420-5

1/2

RPM
220
245

Belt
CUBE

420-7

3/4

280

420-10

305

420-15

1 - 1/2

350

420-20

385

420-30

415
440
485
420-50

5
525
565

420-75

7 - 1/2
600

0
Sones BHP
9353
6.5 0.31
10416
7.2 0.43
11904
8.3 0.64
12966
9.4 0.82
14879
11.9 1.24
16367
14.4 1.65
17643
17.2 2.07
18706
17.7 2.47
20619
20 3.31
22319
23 4.19
24020
26 5.23
25508
29 6.26

0.125
Sones BHP
7846
6.0 0.37
9104
6.7 0.50
10785
7.7 0.73
11959
8.8 0.94
14037
11.2 1.38
15629
13.5 1.81
16982
16.1 2.24
18103
17.1 2.65
20076
19.7 3.51
21817
22 4.41
23553
25 5.46
25069
29 6.51

0.25
Sones BHP
5075
5.5 0.35
7304
6.1 0.53
9418
7.1 0.78
10781
8.0 1.00
13050
10.1 1.46
14731
12.4 1.91
16148
14.9 2.37
17316
16.0 2.81
19394
19.1 3.69
21220
22 4.61
23030
25 5.68
24604
29 6.75

STATIC PRESSURE IN INCHES OF W.G.


0.375
0.50
0.75
1.00
1.25
1.50
1.75
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP

7419
6.6 0.77
9272
7.3 1.02
11925
9.4 1.52
13791
11.7 1.99
15303
13.8 2.45
16532
14.7 2.89
18681
17.5 3.81
20560
21 4.78
22417
25 5.88
24027
28 6.96

10562
8.6 1.54
12701
10.7 2.05
14363
13.0 2.53
15691
14.6 2.98
17960
17.2 3.91
19904
20 4.88
21806
24 6.02
23451
28 7.15

9246
8.5 1.92
12028
10.9 2.56
13652
12.8 3.07
16313
16.2 4.07
18497
19.1 5.10
20544
23 6.25
22295
27 7.38

10151
10.6
2.82
14277
14.9
4.09
16795
14802
18.1
5.20 17.6 5.16
19112
17437
21
6.43 21 6.50
21023
19561
25
7.63 24 7.75

15398
21 6.38
17884
24 7.77

15479
26 7.47

ROOF UPBLAST
AVG. DISCHARGE VEL. (FPM) - CFM/11.72 MAXIMUM RPM - 490
MAX. BHP AT A GIVEN RPM - (RPM/246)3 MAX. MOTOR FRAME SIZE - 213T
TIP SPEED = RPM X 12.63

DRIVE

MODEL

HP

480-5

1/2

RPM
180
200

Belt
CUBE

480-7

3/4

225

480-10

250

480-15

1 - 1/2

285

480-20

315

480-30

335
360
395
480-50

5
425
460

480-75

7 - 1/2
490

0
Sones BHP
11016
5.5 0.33
12240
6.3 0.45
13770
7.5 0.65
15300
9.0 0.88
17442
11.1 1.31
19278
12.9 1.77
20502
14.6 2.13
22032
16.8 2.64
24174
21 3.49
26010
22 4.35
28152
25 5.51
29988
28 6.66

0.125
Sones BHP
8924
4.9 0.39
10490
5.8 0.53
12261
7.0 0.73
13988
8.5 0.98
16332
10.6 1.43
18274
12.5 1.90
19558
14.2 2.26
21153
16.5 2.79
23373
20 3.65
25266
21 4.52
27464
24 5.70
29342
27 6.86

STATIC PRESSURE IN INCHES OF W.G.


0.25
0.375
0.50
0.625
0.75
1.00
1.25
1.50
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
7688
5.3 0.52
10132
6.6 0.76
12248
8.2 1.04
14991
10.0 1.52
17116
11.8 2.01
18507
13.6 2.39
20222
16.1 2.93
22572
20 3.81
24521
21 4.69
26776
24 5.89
28697
27 7.06

9988
7.9 1.03
13240
9.6 1.55
15719
11.3 2.08
17320
13.0 2.49
19142
15.3 3.05
21605
19.2 3.94
23679
20 4.85
26064
23 6.07
28051
26 7.26

11154
9.2 1.52
14033
10.4 2.09
15785
12.3 2.51
17848
14.7 3.10
20621
18.5 4.07
22764
19.4 4.98
25219
22 6.22
27291
25 7.43

11996
10.2 2.03
14074
11.2 2.49
16410
13.7 3.12
19343
17.6 4.11
21766
18.7 5.09
24373
22 6.37
26497
25 7.59

11811
11.3 2.38
14749
12.7 3.08
18035
14722
16.6 4.13 14.9 3.97
20556
17922
17.7 5.12 15.6 5.09
23399
21163
21 6.46 18.5 6.52
25704
23674
24 7.75 22 7.85

18582
18.7 6.42
21437
20 7.84

18846
24
7.67

Performance shown is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings
do not include the effects of appurtenances in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

33

Typical Specifications

Belt Drive Specifications


Spun aluminum exhaust fans shall be centrifugal belt
driven type. The fan wheel shall be centrifugal
backward inclined, constructed of aluminum and shall
include a wheel cone carefully matched to the inlet
cone for precise running tolerances. Wheels shall be
statically and dynamically balanced. The fan housing
shall be constructed of heavy gauge aluminum with a
rigid internal support structure. The windband shall be
welded to the one-piece curb cap and on all sizes with
UL/CUL-762.

box installed within the motor compartment. A conduit


chase shall be provided through the base to the motor
compartment for ease of electrical wiring.

Motors shall be heavy duty ball bearing type, carefully


matched to the fan load, and furnished at the
specified voltage, phase and enclosure. Drive frame
assembly shall be constructed of heavy gauge steel.
Motors and drives shall be mounted on vibration
isolators, out of the airstream where no steel to steel
contact between rotating components and the base
shall occur. Fresh air for motor cooling shall be drawn
into the motor compartment through a ten square inch
tube free of discharge contaminants. Motors and
drives shall be readily accessible for maintenance.

Specifier select one of the following mounting


configurations:

Precision ground and polished fan shafts shall be


mounted in permanently sealed, lubricated pillow
block ball bearings. Bearings shall be selected for a
minimum (L10) life in excess of 100,000 hours at
maximum cataloged operating speed. Drives shall be
sized for a minimum of 150% of driven horsepower.
Pulleys shall be of the cast type, keyed and securely
attached to the wheel and motor shafts.
Motor pulleys shall be adjustable for final system
balancing. A disconnect switch shall be factory
installed and wired from the fan motor to a junction
34

All fans shall bear the AMCA Certified Ratings Seal for
sound and air performance.
Each fan shall bear a permanently affixed
manufacturer's engraved metal nameplate containing
the model number and individual serial number for
future identification.

Roof Mounted Upblast Exhaust Fans A leakproof fan housing shall be constructed with
a one piece windband with an integral rolled bead
for added strength and shall be joined to the
curbcap with a continuously welded seam.
Fans shall be Model CUBE, CUBE-HP, or CUBEXP as manufactured by Greenheck.
Sidewall Mounted Exhaust Fans A leakproof fan housing shall be constructed with
a one piece windband with an integral rolled bead
for added strength. Fan shall be provided with a
mounting plate, which is attached and sealed to
the wall prior to locating the entire unit.
Fans shall be Model CWB, or CWB-HP as
manufactured by Greenheck.

Typical Specifications

Direct Drive Specifications


Spun aluminum exhaust fans shall be upblast centrifugal
direct drive type. The fan wheel shall be centrifugal
backward inclined, constructed of aluminum and shall
include a wheel cone carefully matched to the inlet cone
for precise running tolerances. Wheels shall be statically
and dynamically balanced. The fan housing shall be
constructed of heavy gauge aluminum with a rigid internal
support structure.
Motors shall be mounted out of the airstream on vibration
isolators. Fresh air for motor cooling shall be drawn into
the motor compartment free of discharge contaminants.
Motors shall be readily accessible for maintenance.
A disconnect switch shall be factory installed and wired
from the fan motor to a junction box within the motor
compartment. A conduit chase shall be provided through
the curb cap to the motor compartment for ease of
electrical wiring.
All fans shall bear the AMCA Certified Ratings Seal for
sound and air performance.
Each fan shall bear a permanently affixed manufacturers
engraved metal nameplate containing the model number
and individual serial number for future identification.
Specifier select one of the following mounting
configurations:
Roof Mounted Upblast Exhaust Fans

Options and Accessories


For Belt and Direct Drives
UL/cUL Listed
Fans shall be Listed by Underwriters
Laboratory for UL/cUL 705 Listed for all
electrical components.
Fans shall be Listed by Underwriters
Laboratory for UL/cUL 762 Listed for all
electrical components and grease removal
Curb Extensions
Shall be mounted between roof curb and roof
mounted fans to meet NFPA requirements of
40 in. minimum discharge above the roof when
mounted on a minimum 8 in. high roof curb.
Grease Containers
Drain connection shall be constructed of
aluminum and allow for a single point drainage
of grease, water or other residues.
Grease Trap shall include the drain connection
and shall be constructed from aluminum. The
unit shall collect grease and water from the fan
and extract the grease from the water for ease
of grease disposal
Easy Clean Options

A leakproof fan housing shall be constructed with a


one piece windband with an integral rolled bead for
added strength.

Hinge kit shall be constructed of heavy gauge


aluminum hinges and shall include hold open
cables for field installation.

Fans shall be Model CUE as manufactured by


Greenheck.

Non Stick wheel shall be constructed of


aluminum with a non stick coating simular to
Teflon as manufactured by Dupont.

Sidewall Mounted Exhaust Fans


A leakproof fan housing shall be constructed with a
one piece windband with an integral rolled bead for
added strength. Fan shall be provided with a mounting
plate, which is attached and sealed to the wall prior to
locating the entire unit.
Fans shall be Model CW as manufactured by
Greenheck.

Clean out port shall have a hole on the outside


of the windband and a grease repellent
compression rubber fit, allowing access to
entire wheel for cleaning.
Windband Extension shall be constructed from
heavy gauge aluminum tube that raises the
discharge an additional 36 inches.
35

Additional Exhaust Solutions


Series C Models CUE, CUBE, CW, and CWB are commonly used for general clean air, mild grease, and
fume hood exhaust applications. Both Roof Upblast and Sidewall configurations are specifically
designed to discharge air directly away from the mounting surface. These models are constructed of
aluminum and use an aluminum backward inclined wheel. They are UL Listed for electrical or grease.
Performance capacities ranges up to 5 in. wg and up to 30,000 cfm.

Model USGF is ideal for heavy grease exhaust applications as found in char broilers, solid fuel cooking, and
oriental cooking. Sizes range from 140 to 200HP. All are UL Listed for electrical and grease applications and
are capable of exhausting 400 degrees F continuously. The unit is constructed entirely of steel and includes
the non-stick coated steel wheel, Nema-3R disconnect, hinged curb cap, and clean outport. Performance
ranges up to 3 in.wg and up to 7,000 cfm.

Model SWB centrifugal backward inclined belt driven utility fans are designed for supply, exhaust and return
air applications requiring higher discharge velocities and high static pressures. The SWB Series 100 is for
general clean air applicators. The SWB Series 200 fans are constructed with heavy gauge steel. Designed
for light industrial duty and grease applications its capacities ranging from 500 cfm to 30,000 cfm and up
to 5 in. wg of static pressure. SWB fans can be mounted indoors or outdoors.

Model TCB inline belt driven fans are the ideal choice for installations with straight-through air flow
in ducted systems. The wheels used are designed to provide higher efficiencies and lower sound
levels. The fan itself can be mounted horizontally or vertically. Performance capacities range from
306 cfm to 24,000 cfm and up to 4.5 in. wg of static pressure.

Building Value in Air


Greenheck delivers value to

quality, innovative air-related

owners and occupants value

mechanical engineers by

equipment. We offer extra value

the energy efficiency, low

helping them solve virtually any

to contractors by providing

maintenance and quiet

air quality challenges their

easy-to-install, competitively

dependable operation they

clients face with a

priced, reliable products that

experience long after the

comprehensive selection of top

arrive on time. And building

construction project ends.

Our Warranty
Greenheck warrants this equipment to be free from defects in material and workmanship for a period
of one year from the purchase date. Any units or parts which prove defective during the warranty
period will be replaced at our option when returned to our factory, transportation prepaid. Motors are
warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck
prove defective during this period, they should be returned to the nearest authorized motor service
station. Greenheck will not be responsible for any removal or installation costs.
As a result of our commitment to continuous improvement, Greenheck reserves the right to change
specifications without notice.

P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com

Copyright 2005 Greenheck Fan Corp.


Catalog Series C Rev. 5 January 2005 SP

You might also like