Solid State Sensors Linear Current Sensors


FEATURES Linear output AC or DC current sensing Through-hole design Fast response time Output voltage isolation from input Minimum energy dissipation Maximum current limited only by conductor size Adjustable performance and built-in temperature compensation assures reliable operation Accurate, low cost sensing Operating temperature range 25 to 85C Housing: PET polyester ORDER GUIDE BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT
Mtg. Dim. Fig. 1 1 2 1 2 1 2 1a 2 1a 1a Supply Volt. (Volts DC) 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 8 to 16 Supply Current (mA Max.) 19 19 19 19 19 19 19 19 19 19 19 Sensed Current (Amps Peak) 57 75 75 100 120 150 225 225 325 325 625 Offset Volt. (Volts10%) Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Sensitivity mV N* At 12 VDC Nominal TOL 49.6 39.4 39.1 29.7 24.6 19.6 13.2 13.2 9.1 9.4 5.6 5.8 4.4 4.8 2.7 2.1 1.8 1.2 1.5 1.7 1.3 1.3 Offset Shift (%/C) .05 .05 .05 .05 .05 .05 .05 .05 .05 .05 .05

CS Series
LINEAR CURRENT SENSORS MICRO SWITCH CS series linear current sensors incorporate our 91SS12-2 and SS94A1 linear output Hall effect transducer (LOHETTM). The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configuration as shown in mounting dimension figures 1, 1a, 2 and 2a. Normal mounting is with 0.375 inch long 4-40 screw and square nut (not provided) inserted in the housing or a 6-20 self-tapping screw. The combination of the sensor, flux collector, and housing comprises the holder assembly. These sensors are ratiometric.

Catalog Listing CSLA1CD CSLA1CE CSLA1DE CSLA1CF CSLA1DG CSLA1CH CSLA1DJ CSLA1EJ CSLA1DK CSLA1EK CSLA1EL

Response Time ( Sec.) 3 3 3 3 3 3 3 3 3 3 3

BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT


Mtg. Dim. Fig. 1 1 2 1 2 2 2 1a 2 1a 1a 1a Supply Volt. (Volts DC) 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 6 to 12 Supply Current (mA Max.) 20 20 20 20 20 20 20 20 20 20 20 20 Sensed Current (Amps Peak) 72 92 92 125 150 225 235 310 400 550 765 950 Offset Volt. (Volts2%) Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Vcc/2 Sensitivity mV N* At 8 VDC Nominal TOL 32.7 26.1 25.6 19.6 16.2 8.7 9.8 7.6 5.8 4.3 3.1 2.3 3.0 2.1 2.2 1.3 1.1 0.6 1.1 0.7 0.5 0.4 0.3 0.2 Offset Shift (%/C) .02 .02 .02 .02 .02 .020 .0125 .0125 .0125 .0125 .007 .007 Response Time ( Sec.) 3 3 3 3 3 3 3 3 3 3 3 3

Catalog Listing CSLA2CD CSLA2CE CSLA2DE CSLA2CF CSLA2DG CSLA2DJ CSLA2DH CSLA2EJ CSLA2DK CSLA2EL CSLA2EM CSLA2EN

NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. * N = number of turns
PDFINFO p a g e - 0 5 8

58

Honeywell Sensing and Control 1-800-537-6945 USA

1-815-235-6847 International 1-800-737-3360 Canada

Solid State Sensors Linear Current Sensors


SIDE MOUNT WITH 9SS SENSOR, SOURCE OUTPUT
Sensed Offset Volt. (Volts10%) Vcc/2 Vcc/2 Vcc/2 Sensitivity mV N* At 12 VDC Nominal 49.6 39.4 29.7 TOL 5.8 4.4 2.7 Offset Shift (%/C) .05 .05 .05

CS Series

Catalog Listing CSLA1GD CSLA1GE CSLA1GF

Mtg. Dim. Fig. 2a 2a 2a

Supply Volt. (Volts DC) 8 to 16 8 to 16 8 to 16

Supply Current (mA Max.) 19 19 19

Current (Amps Peak) 57 75 100

Response Time ( Sec.) 3 3 3

SIDE MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT


Mtg. Dim. Fig. 2a 2a 2a 2a Supply Volt. (Volts DC) 6 to 12 6 to 12 6 to 12 6 to 12 Supply Current (mA Max.) 20 20 20 20 Sensed Current (Amps Peak) 72 92 125 150 Offset Volt. (Volts2%) Vcc/2 Vcc/2 Vcc/2 Vcc/2 Sensitivity mV N* At 8 VDC Nominal 32.7 26.1 19.6 12.7 TOL 3.0 2.1 1.3 0.6 Offset Shift (%/C) .02 .02 .02 .02 Response Time ( Sec.) 8 8 8 8

Catalog Listing CSLA2GD CSLA2GE CSLA2GF CSLA2GG

NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. *N = number of turns.

MOUNTING DIMENSIONS (for reference only) Figure 1 Figure 2