CeraView

Network Element Manager

User Guide

Part ID: BM-0105-0 Doc ID: DOC-00015446 Rev a.02 January 2007

Notice
This document contains information that is proprietary to Ceragon Networks Ltd. No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.

Registered TradeMarks
Ceragon Networks is a registered trademark of Ceragon Networks Ltd. FibeAir is a registered trademark of Ceragon Networks Ltd. CeraView is a registered trademark of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.

TradeMarks
CeraMapTM, PolyViewTM, EncryptAirTM, ConfigAirTM, CeraMonTM, EtherAirTM, and MicroWave FiberTM, are trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.

Statement of Conditions
The information contained in this document is subject to change without notice. Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.

Information to User
Any changes or modifications of equipment not expressly approved by the manufacturer could void the users authority to operate the equipment and the warranty for such equipment. Copyright 2007 by Ceragon Networks Ltd. All rights reserved.

Corporate Headquarters: Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: info@ceragon.com North American Headquarters: Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: infous@ceragon.com

www.ceragon.com

European Headquarters: Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: infoeuro@ceragon.com APAC Headquarters Ceragon Networks (HK) Ltd. Singapore RO Level 34 Centennial Tower 3 Temasek Avenue Singapore 039190 Tel - + 65 6549 7886 Fax: +65 6549 7011

Contents
General .......................................................................................................... 1 Installation ..................................................................................................... 2 CeraView Configuration ..............................................................................14 CeraView Security........................................................................................18 Logging in to CeraView ...............................................................................23 CeraView Main Window...............................................................................24 Menus ...........................................................................................................33
File Menu.............................................................................................................. 33 Configuration Menu ............................................................................................ 40 Alarms Menu........................................................................................................ 63 Performance Menu .............................................................................................. 67 Maintenance Menu .............................................................................................. 76 Protection for FibeAir 1500P/640P..................................................................... 82 Protection for FibeAir 3200T .............................................................................. 85

General
This guide explains how Ceragons CeraView management software is used to configure and monitor FibeAir systems. The FibeAir systems covered in this guide include: FibeAir 1500P FibeAir IP-MAX FibeAir 640P FibeAir 1500HP FibeAir 1500SP FibeAir 3200T

System Requirements
The following are system requirements for the CeraView management software. For Windows:
Specification Hardware Type Processor Memory (RAM) Available Drive Space Operating System Display Monitor Serial Port Ethernet Ports Minimum Any type Pentium 4, 2.8 GHz 256 MB 400 MB Windows 2000/2003/XP 1024x768 True Color RS-232 (HyperTerminal) 1 Recommended Any type Pentium 4, 3.2 GHz or higher 512 MB 1 GB Windows 2000/2003/XP 1024x768 True Color RS-232 (HyperTerminal) 1

For UNIX:
Specification Hardware Type Memory (RAM) Available Drive Space Operating System Display Monitor Ethernet Ports Minimum Blade 100, Ultra 5 256 MB 400 MB Solaris 8 or 10 1024x768 True Color 1 Recommended Ultra 10 512 MB 1 GB Solaris 8 or 10 1024x768 True Color 1

CeraView User Guide

Installation
CeraView installation is a simple process that takes just a few minutes. This section provides CeraView installation procedures for different platforms.

Installation for Standalone


To install CeraView as a standalone platform: 1. Run the CeraView installation program provided with the CeraView software. The main window appears:

2.

Click Next. The License Agreement window appears:

CeraView User Guide

3.

Click I accept and Next. The NMS Integration window appears:

CeraView User Guide

4.

Select StandAlone and click Next. The Standalone Folder window appears.

CeraView User Guide

5.

Click Choose and select the directory in which you want to install the CeraView software. If you want to restore the system-selected directory, click Restore Default Folder.

6.

Click Next. If a message appears informing you that a previous version of CeraView will be uninstalled, click Continue. Follow the remaining instructions. CeraView files are installed in the directory you specified.

CeraView User Guide

Installation for HP OpenView


To install CeraView for HP OpenView: 1. Run the CeraView installation program provided with the CeraView software. The main window appears:

2.

Click Next. The License Agreement window appears:

CeraView User Guide

3.

Click I accept and Next. The NMS Integration window appears:

CeraView User Guide

4.

Select HP OpenView and click Next. The HP OpenView Folder window appears.

CeraView User Guide

5.

Click Choose and select the directory in which HP OpenView was installed. If you want to restore the system-selected default directory, click Restore Default Folder.

6.

Click Next. If a message appears informing you that a previous version of CeraView will be uninstalled, click Continue. Follow the remaining instructions. CeraView integration files are installed in the HP OpenView directory.

CeraView User Guide

Installation for SNMPc


To install CeraView for SNMPc: 1. Run the CeraView installation program provided with the CeraView software. The main window appears:

2.

Click Next. The License Agreement window appears:

CeraView User Guide

10

3.

Click I accept and Next. The NMS Integration window appears:

CeraView User Guide

11

4.

Select SNMPc and click Next. The SNMPc Folder window appears.

CeraView User Guide

12

5.

Click Choose and select the directory in which SNMPc was installed. If you want to restore the system-selected default directory, click Restore Default Folder.

6.

Click Next. If a message appears informing you that a previous version of CeraView will be uninstalled, click Continue. Follow the remaining instructions. CeraView integration files are installed in the SNMPc directory.

CeraView User Guide

13

CeraView Configuration
Before you run CeraView, you can configure the way CeraView will operate and to which servers it will connect. CeraView configuration is performed using the CeraView Configuration utility, as follows: Click Start on the desktop, and select Programs, CeraView, CeraView Configuration. The CeraView Configuration utility main window appears.

CeraView Configuration Utility Main Window

The CeraView Configuration utility is divided into the following sections: Time and Intervals Remote Hosts

CeraView User Guide

14

File Transfer Advanced To open a section, click on its icon on the left side of the window. In each section, if you want to restore default values, click Restore Defaults. If you want to reload the page after you made changes, click Reload Page. Each section is described in the following paragraphs.

Time and Intervals In the Time and Intervals section, you can configure the following:
Short Refresh Interval

The value (seconds) determines how often windows that require frequent refreshing will be refreshed. The value (seconds) determines how often windows that do not require frequent refreshing will be refreshed. The value (seconds) determines how often the network element will be checked for connectivity. The value (seconds) determines the maximum time the system will wait after an SNMP command before timing out. The value determines the maximum number of times a request can be made to an element after a timeout.

Long Refresh Interval

Keep Alive Interval

SNMP Timeout

SNMP Number of Retries

Remote Hosts In the Remote Hosts section, you can configure the following:
User Actions Logger Host Address

The IP or host name of the user actions logger server. If left blank, logging will be disabled. The number of the port from which the user actions logger will receive data. CeraViews Security Server IP or host name. Leave this field blank if CeraView security is run locally. The number of the port from which the Security Server will receive data.

User Actions Logger Port Number

Security Server Host Address

Security Server Port Number

CeraView User Guide

15

Enable Connect Via Proxy Primary Proxy Server Address

To enable a CeraView connection via a proxy server. The address of the primary proxy server to which you are connecting. The port number of the primary proxy server to which you are connecting. The address of the secondary proxy server to which you are connecting. The port number of the secondary proxy server to which you are connecting.

Primary Proxy Server Port Number

Secondary Proxy Server Address

Secondary Proxy Server Port Number

File Transfer Configuration In the File Transfer Configuration section, you can configure the following:
TFTP Server Address

Trivial File Transfer Protocol server IP. You must enter an IP associated with your PC. The directory in which the network element software files are located. If you installed PolyView, make sure the same location is specified in the PolyView configuration. The value (seconds) determines when the TFTP server will time out after a request. The value determines the maximum number of times a TFTP request can be made to an element after a timeout.
Select True if you are using an intrenal TFTP server. Select False if you

TFTP Files Location

TFTP Timeout

TFTP Retries

Use Internal TFTP Server

are using an external TFTP server. If you installed PolyView on this PC, select False, since PolyView uses its own TFTP server.

CeraView User Guide

16

Advanced Configuration In the Advanced Configuration section, you can configure the following:
VC Calculation from KLM

For ADM tributary paths. Defines the formula used to calculate the VC (Virtual Container) from the KLM values. Select True if you want values to be displayed in metric units. The default SNMP write community. Leave this field blank if you didnt change the SNMP write community value in the network element configuration. The language in which the CeraView application will appear.

Use Metric Display SNMP Default Write Community

Select Interface Language

CeraView User Guide

17

CeraView Security
This section explains how to set up CeraView security.

Starting the Security Application


To start the CeraView Security Application, in the Start menu on your desktop, select Programs, CeraView, CeraView Security. The Security application main window appears.

CeraView Security Application Main Window

Using the Security Application


Security for CeraView is obtained by creating users and user groups with designated access rights to the different CeraView components. Note that upon installation, two users and two groups are created, as follows: Users: Admin - Always placed in the Admin group Viewer - Initially placed in the Observer group

CeraView User Guide

18

Groups: Admin - Full access Observer - Read-only access The administrator can add new users and groups, and modify existing ones, but cannot rename or delete the Admin user or group.

Creating a New User


To create a new CeraView user: 1. In the main window (shown above), right click Users, and select Add User. You can also select Users, and in the Edit menu, select Add User. The User Configuration window appears

User Configuration Window

2. 3. 4.

Enter the new users name and password in the fields at the top of the window. User changed password at ... appears if you selected Users can change their passwords in the Setting window (described below), and the user changed their password. In the Access by Subnet area, you can assign different access rights to the new user according to subnet. For example, you can give the user Administrator rights on one subnet and Observer rights on another. Notes: * * * You cannot enter the same subnet twice for the same user. If none of the subnets you entered match an IP the user tries to connect to, the user will be denied access to that IP. If more than one subnet matches an IP the user tries to connect to, the group that belongs to the subnet that matches the IP the closest will be used for the IP access. For example, you created the user Joe with the following rights: 172.24.0.0 : Observer, and 172.24.30.0 : Administrator. If Joe requests access to 172.24.30.5, he will be granted Administrator rights for that IP.

CeraView User Guide

19

Even though both subnets you assigned to Joe match the IP he requested, the subnet 172.24.30.0 is closer to the IP than the other one. In order to obtain default Observer rights for IP addresses that do not match any of the subnets in the list, you need to assign the subnet 0.0.0.0 : Observer to the user, and the subnet mask must also be 0.0.0.0. 5. Click OK.

Working with Users


Once you create users, you can perform several user-related operations. Modify User Defnition 1. In the main window, expand the Users list, right click the name of a user you want to modify, and select Configure User. Or, select the user in the list, and in the Edit menu, select Configure User. The User Configuration window appears (shown above in the section Creating a New User). 2. Change the user configuration as desired in accordance with the explanation provided in the Creating a New User section above.

Copy User 1. In the main window, expand the Users list, right click the name of a user you want to copy, and select Copy User. Or, select the user in the list, and in the Edit menu, select Copy User. The Copy User window appears.

Copy User Window

2.

Enter the new users name and password, and click OK. A new user will be created with the same access rights as the user you chose to copy.

Delete User Note that you cannot delete the Admin user.

CeraView User Guide

20

In the main window, expand the Users list, right click the name of a user you want to delete, and select Delete User. Or, select the user in the list, and in the Edit menu, select Delete User. Import/Export Users To import users from an external file to your current CeraView session, in the main window select File, Import Users. To export users from your current CeraView session to a different CeraView session, in the main window select File, Export Users. User Password Configuration To configure user password settings: 1. In the main window, select File, Setting.

User Password Configuration Window

2.

Select the desired options, and click Apply.

Creating a New User Group


User groups can be assigned collective rights to different CeraView components. To create a new group of users: 1. In the main window, click Groups, and in the Edit menu select Add read-only Group or Add read-write Group. If you select Read-Only Group, initially the group will only have read-only access rights. If you select Read-Write Group, initially the group will have read-write access rights. 2. Enter the name of the group in the window that appears, and click OK.

CeraView User Guide

21

Working with Groups


Once you create groups, you can perform several group-related operations. To perform a group-related operation: 1. 2. In the main window, expand the Groups list, and click the name of the group you want to work with. In the Edit menu, select Configure Group if you want to rename the group. Note that you cannot rename the Admin group. 3. Select Copy Group if you want to duplicate the group you selected. In the Copy Group window that appears, enter the groups name, and click OK. A new group will be created with the same access rights as the group you chose to copy. 4. Select Delete Group if you want to delete the group you selected. Note that you cannot delete the Admin group. 5. For each group, to configure access rights for specific CeraView components, double-click the key icon beside the component name. The Access Rights window appears.

Access Rights Window

Mark the checkbox of each CeraView component you want the group to have access to, and click OK.

CeraView User Guide

22

Logging in to CeraView
Note: For Windows 2000/2003/XP, the user on the local PC must be defined as an Administrator, which can be done as follows: 1. 2. 3. 4. 5. 6. In the Control Panel, double-click Users and Passwords. Click Add. Click Browse, and select the user from the list. Click Next. Select Other and Administrators. Click Finish.

To log in to CeraView: 1. Select Start, Programs, CeraView, CeraView Element Manager. The Login window appears.

CeraView Login Window

2.

Enter the relevant information in the fields. The default Administrator login is: User Name: admin Password: ceragon The default Viewer login is: User Name: viewer Password: viewer Select Save Password if you want CeraView to remember the user name and password you entered.

3.

Click OK.

CeraView User Guide

23

CeraView Main Window


After you log in to CeraView, the Main window appears. The Main window is your starting point for all operations. Below is a description of the menus, toolbars and other features of the Main window.

CeraView Main Window for FibeAir 1500P

Main Window for FibeAir 1500P 311 Mbps with Diversity Protection

CeraView User Guide

24

Main Window for FibeAir IP-MAX

Main Window for FibeAir 640P

CeraView User Guide

25

Main Window for FibeAir 3200T

Title Bar
The Title Bar displays the CeraView version, the agents system name, and the agents IP address.

Menu Bar
The Menu Bar contains menus and menu items used to perform CeraView operations.

Status Line
The line at the bottom of the window indicates if the unit is connected directly to the management station, or through a designated server. The text in the line can include Connected directly, Connected via server, or Connected via server (secured), whereby secured refers to an encoded connection. A secured connection is indicated by a lock icon .

Status Panel
The Status Panel appears on the right side of the window, and includes icons that represent different system information (described in detail below).

CeraView User Guide

26

Toolbar
The Toolbar includes several icons that you can click to perform different operations. Icon Function System Information - used to view and define system information, such as contact personnel and system up time. Trap Forwarding Configuration - used for trap configuration, such as designating managers to which traps will be forwarded. Current Alarms - used to view current active alarms.

Alarm Log - used to view historical alarm records. Input/Output External Alarms - used to configure alarms sent to/from external sources. ODU Configuration - used to configure the left and right ODUs. When XPIC is enabled, an x will appear in the icon.

RFU Configuration - used to configure the FibeAir 1500HP RFU. When XPIC is enabled, an x will appear in the icon. Loopback - used to configure and run left and right unit loopbacks for testing and troubleshooting. Refresh - used to update the front panel view in the main window. Online Help - used to view the online help file.

CeraView User Guide

27

Status Panel Icons


The Status Panel can include the following icons: AES AES is active in the left drawer. AES failure in the left drawer. AES is active in the right drawer. AES failure in the right drawer. AES is active in both drawers. AES failure in both drawers. AES is active in the left drawer, AES failure in the right drawer. AES is active in the right drawer, AES failure in the left drawer. XPIC XPIC is enabled. Top-Most Active Alarm Indicates all clear. Indicates and event alarm. Indicates a warning alarm. Indicates a minor alarm. Indicates a major alarm. Indicates a critical alarm. External Protection External protection, unit is active. External protection, unit is in standby mode. External protection, and the protection or diversity is locked. External protection, unit is in standby mode, and the protection or diversity is locked.

CeraView User Guide

28

Internal Protection Internal protection, left drawer is active. Internal protection, right drawer is active. Internal protection, left drawer is active, and the protection or diversity is locked (described below). Internal protection, right drawer is active, and the protection or diversity is locked (described below). Protection in FibeAir 3200T Protecting carrier in the FibeAir 3200T system. Protected carrier in the FibeAir 3200T system (in-group). Unprotected carrier in the FibeAir 3200T system (in-group). The key icon indicates that the system is in the Lockout or Forced Switch mode. It appears as a result of either a Force Switch or Lockout option selection from the Protection menu. If you select Lockout, protection switching will not occur even if switch criteria is met, until you select Clear Lockout. If you select Force Switch, a switch will occur between the active and standby shelfs, and there will be no further switching until you select Clear Force. In addition, note the following: - If you select Lockout, you cannot perform a Force Switch or Request Switch. - If you select Force Switch, you cannot perform a Request Switch. - Commands that you cannot perform will be disabled in the menu.

Physical View
A physical view of the FibeAir unit is displayed in the Main window. The view provides a virtual display of the IDU front panel.

Example of Physical View in Main Window

The LEDs that appear in the physical view indicate the actual status of the LEDs on the front panel of the IDU. (LED changes on the actual front panels of the units will be updated in the physical views after a slight delay.)

CeraView User Guide

29

The LEDcolors are as follows: Green - indicates proper operation Yellow - indicates a warning Red - indicates a major alarm or severe malfunction Grey - the function is disabled Notes: When a hot swap occurs (a front panel shelf is replaced while the FibeAir unit is operating) the physical view in CeraView will be updated and continue its display. Clicking on some areas in the physical view front panel display will invoke a configuration window. If a hand icon appears when you move the mouse over an area in the panel display, you can click on that area to invoke the relevant configuration window. The following table lists front panel LEDs and their functions.
Module LED Name CH1 hardwareactivated Indications Green - valid signal (when the Wayside channel is supported in hardware) Red - LOS in line Gray - interface is not supported, or Wayside channel is disabled CH 2 hardwareactivated IDC Green or blinking green - active signal Gray - no link or no cable Green - IDC OK Yellow - configuration/firmware mismatch, or fan failure Red - hardware failure in IDC module IDC RMT Red - major alarm in one or both of the remote drawers Red - local remote communication error Green - OK Yellow - minor alarm in one or both of the remote drawers. (If there are both minor and major alarms in the remote, the LED will be red -m indicating the worst alarm) Yellow - fan failure in the remote Prot Green - protection cable OK Red - protection cable failure Gray - protection disabled ----Minor --------Minor Warning Major Major ----Major ------------Severity

CeraView User Guide

30

Module

LED Name Drawer

Indications Green - drawer OK Yellow - drawer in standby mode Red - drawer hardware failure --------Major ----Major Major Major Major --------Major ----Major Minor Major Minor ---------

Severity

ODU

Green - ODU OK Red - ODU failure

CBL

Red - cable open Red - cable short Red - cable swap

Drawer LPBK Radio

Green - OK Green - OK Red - loopback in progress Green - OK Red - LOF/EXC Yellow - SD Line Red - LOS/LOF/EXC Yellow - SD/unexpected Green - OK Gray - disabled

Explanation of FibeAir 3200T Physical View


In the main window for FibeAir 3200T, select the subrack you want to work with by clicking the relevant tab at the top of the window. Then, select a floor to work with by clicking in the floor area. Menus and buttons invoke windows that relate to the floor you are working with. However, some windows relate to all floors, such as the Current Alarms, Alarm Log, and H/W Protection Type windows. Note that FibeAir 1500P panels may be inserted in the carrier levels. When inserted, the panels will operate the same way as those in a FibeAir 1500P system. Upper Level The top level in the window contains the RF unit interfaces, power interfaces, and auxiliary interfaces for all floors in the subrack.

CeraView User Guide

31

The right side of the panel shows the carrier connections to the RF units. Clicking on a connector will invoke the radio configuration window for that carrier. The power input connectors are shown in the middle of the panel. Clicking on a power input connector will invoke the Power input configuration window. At the extreme left side of the panel, the two 9-pin connectors can be used for user channels. When you click the connectors, the auxiliary window opens for configuration. Clicking the upper connector will open the auxiliary window for the upper floor, and clicking the lower connector will open the auxiliary window for the lower floor. The first two RJ-45 type connectors from the left support two management channels. The second pair of RJ-45 type connectors from the left support two Ethernet wayside channels or user channels. When you click the connectors, the appropriate Auxiliary window opens for wayside channel configuration. The third pair of RJ-45 type connectors from the left support two E1/T1 wayside channels. When you click the connectors, the Auxiliary window opens for the appropriate channel configuration. The upper port of the fourth pair of RJ-45 type connectors from the left supports EOW (Engineer Order Wire) cascading. The LED beside the lower connector indicates EOW presence. When you click the connector, the Auxiliary window opens for channel configuration. The window that appears is the auxiliary channel configuration window for the second floor. The remaining pair of 9-pin connectors are used to connect external alarms. FibeAir 3200T supports eight alarm inputs and five outputs. When you click the connectors, the External Alarms window opens for alarm input/output configuration. The lower connector is used for external alarms inputs and the upper is used for external alarms outputs. When you click the input connector, the External Alarms window opens for alarm input/output configuration for the second floor. When you click the output connector, a window opens for floor selection. After choosing a floor, the External Alarms window opens for alarm output configuration for the relevant floor. This feature is relevant only for subrack #1. Lower Levels

The lower (carrier) levels in the main window include the following functions: Modem area, which includes the LED indicators, similar to those of FibeAir 1500P. Mux area, whereby clicking on a connector will invoke the interface configuration window for that carrier. The LED indicators are similar to those for FibeAir 1500P. Cross-connect drawer, which controls the protected system data flow. Clicking on the connector will invoke the cross-connect configuration window.

CeraView User Guide

32

Menus
The following sections describe the CeraView window menus.

File Menu
System Information
This option allows you to view and define information for the FibeAir system. 1. Select File, System, Information., or click the System Information icon. The System Information window appears.

System Information Window

2. 3. 4.

In the Current Time area, click Date/Time Configuration and set the date and the time (in the format HH:MM:SS). The read-only Description field provides information about the FibeAir system. (Optional) In the Name field, enter a name for this link. By convention, this is the nodes fully-qualified domain name.

CeraView User Guide

33

5. 6. 7. 8. 9.

(Optional) In the Contact field, enter the name of the person to be contacted when a problem with the system occurs. Include information on how to contact the designated person. (Optional) In the Location field, enter the actual physical location of the node or agent. The Up Time field is read-only and shows how long the system has been operating continuously. For Left/Right Carrier Name, specify the name you want to give the carrier for identification purposes. Click Apply to save the settings.

10. Click Close.

Versions
The Versions window displays current software versions and relevant serial numbers. It also displays software versions that will take effect after the unit is reset. 1. Select File, System, Versions. The Versions window appears.

Versions Window

2. 3.

Click the Post Reset Versions tab to see the versions that will appear after the modules are reset. Click the Serial Numbers tab for a list of current component serial numbers.

CeraView User Guide

34

Software Download
This option enables you to download the latest software versions. 1. Select File, Software Download. The Software Download window appears.

Software Download Window

2. 3. 4.

The Files Location field shows the directory in which the software files are located. The TFTP Server Address field shows the IP of the TFTP server used to download the software. In the file selection area, click Select to choose the software file you want to download from a list that opens in a separate window.

CeraView User Guide

35

Note that the Single File DL option enables you to download a single file that includes all relevant upto-date software files. 5. Select an option for Perform ODU Internal Download if you want an internal ODU download for the right drawer, left drawer, or both drawers. If you select an option, the download will occur automatically after the ODU download is completed. Select Reset IDC after Download if you want the unit to reset after the files are downloaded successfully. In the Software Download window, click Apply. The Progress bar in the Software Download window shows how the download process is progressing. To terminate the process, click Abort. Results of the operation appear in the Download Log area.

6. 7. 8.

Configuration Report
This option generates a report that includes various parameters and their values, such as system description, software versions, and Tx/Rx frequencies. 1. Select File, Configuration Report. The Configuration Report window appears.

Configuration Report Window

2.

Click Save to save the report in a file for later analysis.

Configuration File Upload/Download


This option is used to upload a configuration file from a FibeAir unit to the management module, or download a file from the management module to the FibeAir unit. 1. Select File, Configuration File, Upload from Element/Download to Element.

CeraView User Guide

36

The Upload/Download Configuration File window appears.

Upload/Download Configuration File Windows

2.

When uploading, click Browse, and select the directory and name of the file you want the configuration to be uploaded into. Then click Upload. When downloading, click Browse and select the configuration file you want to download. Then click Download. After the file is uploaded/downloaded, changes will take place only after the unit is reset.

Disk Files
This option is used to view information about the disks and files stored in the IDU. 1. Select File, System, Disk Files. The Disk Files window appears.

CeraView User Guide

37

Disk Fles Window

2.

The window displays disk space information and information concerning each file stored in the disk. In the Properties column, the following icons may appear: Indicates that the file is compressed. Indicates a system CRC file (Cyclic Redundancy Check) Indicates a security-related DSS file (Digital Signature Standard)

AES (Advanced Encryption Standard)


When FibeAir is configured with encryption, data received from the line interface (plain text) is coded, and sent via the radio. The remote site will receive the data in its coded form, decode it back to plain text, and then send it on through the line to the user. The encryption used is the AES (Advanced Encryption Standard) algorithm, as specified by the FIPS 140-2 Level 2 Security standard. AES is a symmetric block cipher that can encrypt (encipher) and decrypt (decipher) information. Integrated in the FibeAir IDU, the encryption algorithm is completely transparent to the operator, functioning automatically without the need for manual key loading or replacement. To view AES information: 1. Select File, AES, Left/Right. The AES window appears.

CeraView User Guide

38

AES Information Window

2.

If AES is configured for your system, this window displays the AES state, which is configured via the terminal setup.

New Session
Select this item to log in for a new CeraView session. The new session will appear in addition to the current session. When you select this item, the CeraView login window appears for you to specify the IP address of the FibeAir unit you want to access.

Remote Session
Select this item to log in for a new CeraView remote session. The new session will appear in addition to the current session. When you select this item, the CeraView login window appears for you to specify the IP address of the FibeAir unit you want to access.

Exit
Select this item to exit the CeraView application. You can also exit by clicking on the Close icon (x) in the title bar. If you select Exit and a continuous logging operation is still active, you will be prompted to confirm the exit. Note: It is recommended to use this option if you need to manage more than one FibeAir unit simultaneously.

CeraView User Guide

39

Configuration Menu
IDU
External Alarms The procedure detailed in this section is required only if alarms generated by external equipment are connected to the IDU, or if the IDU alarm outputs are connected to other equipment (alarms I/O connector). 1. Select Configuration, IDU, External Alarms, or click the External Alarms icon, or click the Alarms In/Out area in the physical view. The External Alarms window appears.

Input/Output External Alarms Window

Note: The window above appears in a FibeAir 1500P system. Other systems support different numbers of external alarm inputs/outputs. For example, In FibeAir 3200T systems, the middle floor manages 8 external alarm inputs and 5 alarm outputs, and the top and bottom floors manage 5 external alarm inputs. The microcontroller in the IDU reads alarm inputs (dry contact) and transfers them to CeraView. This allows FibeAir to report external alarms that are not related to its own system. For each alarm on the left side of the window, do the following: 2. 3. 4. 5. Click the box next to the alarm number to enable/disable the alarm. If you enable an alarm, enter a description of the alarm in the text field. Select the alarms severity level from the drop-down list (Major, Minor, Warning, Critical, or Event). FibeAir provides three or five alarm outputs that can be used by other systems to sense FibeAir alarms. The outputs are configured in the Alarm Outputs area. The alarm outputs are Form C Relays. Each output relay provides three pins, as follows: Normally Open (NO), Normally Closed (NC), Common (C).

CeraView User Guide

40

Select the alarm output type (Major, Minor, Warning, External, Power, etc.). The default type for all relays is Power. The relays may be connected to customer-specific applications. 6. 7. Click Apply to save the settings. Click Close.

Auxiliary Channel (appears only if the channel exists) 1. Select Configuration, IDU, AuxiliaryChannel. The Auxiliary Channel window appears.

Auxiliary Channel Configuration Window

The example above shows a dual Ethernet Wayside channel. A different channel may appear (such as T1 or RJ-45 bridge) according to the system configuration. In addition, other options may or may not appear, depending on your system configuration. 2. 3. 4. 5. 6. 7. 8. Select Enabled to activate the respective EOW, Wayside, or User channels. Select the Cascade Enabled option to activate the dual EOW channels in cascade mode. The Route to Radio is read-only, and shows the default route, whereby the right drawer is set for Channel 1 and the left drawer is set for Channel 2. In the Wayside/User Channel Type areas, select the type of channel you want to use. If Bandwidth is supported for the channel, specify the desired rate, Low or High. Click Apply to save the settings. Click Close.

CeraView User Guide

41

Transport The Transport Configuration window is used to configure the communication protocol. 1. Select Configuration, IDU, Transport. The Transport Configuration window appears.

Transport Configuration Window

2. 3. 4.

Click the drop-down list and select the protocol your radio is using. Click Apply to save the settings. Click Close.

Power Input (FibeAir 3200T) The Power Input window is used to enable or disable alarms for the power source. 1. Select Configuration, IDU, Power Input. The Power Input window appears.

Power Input Configuration Window

2.

Select the power source for which you want to enable alarms.

CeraView User Guide

42

ODU/RFU Configuration

ODU Configuration 1. Select Configuration, ODU/RFU, Left/Right, ODU Configuration, or click the Left/Right ODU Configuration icon. The ODU Configuration window appears.

ODU Configuration Window

2. 3.

The ODU Parameters area is read-only. The Duplex Frequency value changes in accordance with the TX/RX frequency values. You can change the TX and RX frequencies of the ODU in one of the following ways: Manually enter the TX frequency and/or RX frequency (6, 7, 8, 10, 11 GHz only) in the respective fields. Or click the up/down arrows in the TX Channel field to select the channel (the frequency will be updated accordingly).

4.

For the Frequency Control area, note the following: Only one standard is generally shown, predetermined by the ODU parameters. When the standard is unknown, the Tx Channel field will be disabled.

CeraView User Guide

43

Tx Channel selection is possible only when a predefined standard file was installed. In some cases, you may be able to select more than one standard. The Rx Frequency field is read-only for systems other than 6, 7, 8, 10, and 11 GHz. The arrow on the right side in the Frequency Control area is green when communication exists between the local and remote units. If there is no communication between the units, the arrow is red. 5. Select the XPIC Enabled option if you want to activate the XPIC mechanism. With FibeAir operating in co-channel dual polarization (CCDP) mode, using the cross polarization interference canceller (XPIC) algorithm, two STM-1 signals can be transmitted over a single 28 MHz channel, using vertical and horizontal polarization. This enables double capacity in the same spectrum bandwidth. Note: Setting XPIC for the right drawer will effect the left drawer as well, and vice versa. 6. Select Local Only if you want to frequency changes to affect only the local unit. Select Local + Remote if you want frequency changes to affect the remote unit as well. Note: If there is a communication failure between the local and remote units, the Local + Remote option will be disabled. 7. In the Transmitter Configuration area, select Tx Mute to block transmission to the remote unit. By default, this option is not selected. Select ATPC to activate the Automatic Transmit Power Control feature. For Set Tx Level, enter or select the designated signal level. Possible range is -10 to max power level. By default, the transmit signal level is set to the maximum power level. The Monitored Tx Level field (read-only) displays the system's transmitted power level. 8. In the Receiver Configuration area, the Set Reference Rx Level field should be set to the Rx level to which the actual level will be compared. This field is active only if ATPC is enabled. The Monitored Rx Level field (read-only) displays the received power level. 9. Click Apply to save the settings. 10. Click Close.

RFU Configuration 1. Select Configuration, ODU/RFU, Left/Right, RFU Configuration, or click the Left/Right RFU Configuration icon. The RFU Configuration window appears.

CeraView User Guide

44

RFU Configuration Window

Note: In the window shown above, the RFU illustration shows two antennas. Only one antenna appears in the illustration if the IFC (IF Combiner) is not supported. For All-Indoor systems, the RFU Configuration window appears as follows:

CeraView User Guide

45

RFU Configuration Window for All-Indoor Systems

The fields in the RFU Configuration window are the same as those described in the ODU Configuration section above. Additional fields in the RFU Configuration window include the following: Location - This field indicates the physical location of the RFU. Receiver Mode - the Rx path, which can be set to Main, Diversity, or Combined. This field appears only if IFC (IF Combiner) is supported. RSL Connector Source - can be Diversity or Main. This field appears only if XPIC is not supported and IFC is supported. Monitored Rx Level (Diversity) - (read-only) displays the received power level of the Diversity channel. RFU Log File The RFU log file is a cyclic log file that records system parameters in an RFU-based memory module. For more information about the file, see the FibeAir Troubleshooting Guide. 1. Select Configuration, ODU/RFU, Left/Right, RFU Log File.

CeraView User Guide

46

RFU Log File Configuration Window

2. 3. 4. 5.

Click Enabled to activate the file. For RFU Log Period, specify the amount of time, in seconds, that the file will be active. Click Apply to save the settings. Click Close to close the window.

Multi Rate Multi Constellation This option allows you to set the modulation and bit rate of the system. 1. Select Configuration, ODU/RFU, Left/Right, Multi Rate Multi Constellation. The Multi Rate Multi Constellation window appears.

Multi Rate Multi Constellation Window

2. 3.

Select a bit rate and an occupied bandwidth. The selection you make will determine the modulation (16, 32, 64, 128, or 256 QAM), and the system will be configured accordingly. Click Apply.

CeraView User Guide

47

Note: After you apply the setting, the relevant drawer will be reset. 4. Click Close.

Delay Calibration This window enables you to calculate the data transfer delay between antennas, for system use. Note: This window will not appear if IFC is not supported. 1. Select Configuration, ODU/RFU, Left/Right, Delay Calibration. The Delay Calibration window appears.

Delay Calibration Window

2.

For Time Delay, if you know the amount of time (in nanoseconds) of the delay between antennas, enter it in the field manually, or use the up/down buttons. If you don't use the Time Delay field, you can use the WG Length Difference field to enter the waveguide length difference (in meters) between the Main and Diversity paths. If you select this option, you must first use the Select WG Type field to specify the waveguide you are using. The type can be EW63, EW64, EW77, EW85, or EW90.

3. 4.

After you enter the waveguide type and length difference, and click Apply, CeraView will calculate the delay difference in nanoseconds and record the result as the delay calibration value, for system use. If you do not use the manual calibration fields described above, you can instruct CeraView to send a request to the agent to calculate the delay automatically. To do so, select Click to Auto Calibrate, and click Calibrate. A message will appear warning that the delay calculation process will affect traffic. Confirm the operation in the window by clicking Yes.

CeraView User Guide

48

Interfaces
STM1/OC3 1. Select Configuration, Interfaces, Left/Right, STM1/OC3, or click the STM1/OC3 area in the physical view of the CeraView main window. STM1 Interface Configuration:

STM1 Interface Configuration Window

OC3 Interface Configuration Window

CeraView User Guide

49

2 x STM1 Interface Configuration:

2 x STM1 Interface Configuration Window In the configuration window for 2 x STM1, each interface is configured in a separate section by clicking the tabs at the top of the window. 2. 3. 4. 5. 6. In the Fiber STM1 Mode field, select Enabled if you want the channel to be active with alarm generation. If Enabled is not selected, the channel will be active, but no alarms will be generated. In the Excessive Error field, select the level above which an Excessive BER alarm is issued for errors detected over the radio link. In the Signal Degrade field, select the level above which a Signal Degrade alarm is issued for errors detected over the radio link. The BER field shows the value above which a BER alarm is issued for errors detected over the radio link. In the Trace Identifier area, select J0 Operation to use the J0 byte as a trace identifier in the SDH RSOH. If you activate J0, use the Transmitted J0 and Expected J0 fields to define the IDU identifier string. Select Send AIS on RS TIM if you want Alarm Indication Signals to be sent in the event of RS TIM (Trace Identification Mismatch). 7. 8. Click Apply to save the settings. Click Close.

CeraView User Guide

50

Fast Ethernet 1. Select Configuration, Interfaces, Left/Right, Fast Ethernet, or click the Fast Ethernet interface area in the physical view of the CeraView main window.

Fast Ethernet Interface Configuration Window Note: Two Fast Ethernet tabs will appear only if the unit is configured with a 2 x Fast Ethernet port. 2. 3. 4. 5. Select Enabled if you want the channel to be active with alarm generation. If Enabled is not selected, the channel will be active, but no alarms will be generated. Select Auto Negotiation if you want the unit to determine the Fast Ethernet data transfer protocol automatically and operate accordingly. If you did not select Auto Negotiation, select either 10BaseT or 100BaseT, and either Half Duplex or Full Duplex. If the unit is configured for 2 x Fast Ethernet and QOS (Quality of Service), in the Priority Options area, select the traffic type to which you want to assign top priority. For Queuing Scheme, select one of the following: Fixed Priority - Algorithm used to ensure that a queue with a higher priority is always served before a queue with a lower priority.

CeraView User Guide

51

Weighted Fair - A dynamic scheduling method that provides fair bandwidth allocation to all network traffic. The method applies priority or weights to identified traffic, to classify traffic into conversations and determine how much bandwidth each conversation is allowed relative to other conversations. The algorithm is flow-based, simultaneously scheduling interactive traffic to the front of a queue to reduce response time and evenly share the remaining bandwidth among high-bandwidth flows. 6. 7. Click Apply to save the settings. Click Close.

Gigabit Ethernet
1. Select Configuration, Interfaces, Left/Right, Gigabit Ethernet, or click the Gigabit Ethernet interface area in the physical view of the CeraView main window.

Gigabit Ethernet Interface Configuration Window 2. 3. 4. Select Enabled if you want the channel to be active with alarm generation. If Enabled is not selected, the channel will be active, but no alarms will be generated. In the Gigabit Ethernet Tx Mute Criteria area, select one or more the criteria that will force the transmission of data to be muted. For Gigabit Ethernet Flow Control, select Enabled if you want the system to control the data flow automatically. This means that if an E1/T1 interface is not in use, the E1/T1 capacity will automatically be allocated for the Ethernet traffic. Click Apply to save the settings. Click Close.

5. 6.

CeraView User Guide

52

DS3/E3
1. Select Configuration, Interfaces, Left/Right, DS3/E3, or click the DS3/E3 interface area in the physical view of the CeraView main window.

DS3 Interface Configuration Window Note: Shown above is a window that appears for the DS3 interface. The window is similar for E3 interfaces. 2. 3. 4. 5. 6. 7. 8. In the Excessive Error field, select the level above which an Excessive BER alarm is issued for errors detected over the line. In the Signal Degrade field, select the level above which a Signal Degrade alarm is issued for errors detected over the line. In the DS3/E3 area, select Enabled to activate the port. The Line Coding fields show the coding system used for each DS3/E3 line. For Cable Length, select the length of the cable used for each DS3 line. Click Apply to save the settings. Click Close to close the window.

CeraView User Guide

53

E1/T1 1. Select Configuration, Interfaces, Left/Right, E1/T1, or click the E1/T1 interface area in the physical view of the CeraView main window.

E1 Interface Configuration Window for FibeAir 1500P

CeraView User Guide

54

T1 Interface Configuration Window for FibeAir 640P 2. In the Trib Thresholds area, for Excessive Error, select the level above which an Excessive BER alarm is issued for errors detected over the radio link. For Signal Degrade, select the level above which a Signal Degrade alarm is issued for errors detected over the radio link. 3. 4. 5. 6. 7. In the E1/T1 Ports area, select the ports you want to enable. For T1s, in the Line Coding area, select the appropriate protocol. For T1s, in the Cable Length area, select the lengths of the cables that will connect the ports to the network. Click Apply to save the settings. Click Close.

CeraView User Guide

55

Radio 1. Select Configuration, Interfaces, Left/Right, Radio, or click the Radio or East or West area in the physical view. The Radio Configuration window appears.

Radio Configuration Window

2.

In the Radio Thresholds area, for Excessive Error, click the drop-down list and select the level above which an Excessive BER alarm is issued for errors detected over the radio link. For Signal Degrade, select the level above which a Signal Degrade alarm is issued for errors detected over the radio link. The BER field is read-only and shows the value above which a BER alarm is issued for errors detected over the radio link.

3. 4.

In the Link Parameters area, select the direction of the FibeAir radio. The direction you select will be indicated in the physical view. For Link ID, specify the identification number of the link. Note: When working with an IDU that has the Link ID feature on one end and an IDU that does not have this feature on the other end, set the Link ID to 1.

5.

For Latency Type, select High (default value) if you want the ATM and channel interleavers to be active. Select Low to bypass the interleavers. If you select Low, the latency of the link will be lower than the high latency by 50-200 msecs (depending on the modem's Fsymbol), and the system gain will be approximately 0.2 dB lower. Note: If you change the latency value and click Apply, you will be prompted to reset the drawer you were configuring.

6. 7.

Click Apply to save the settings. Click Close.

CeraView User Guide

56

Management System
IP Configuration 1. Select Configuration, Management System, IP Configuration. The IP Configuration window appears.

IP Configuration Window

2. 3. 4. 5.

In the Ethernet Addresses area, specify the Ethernet IP Mask and Default Router IP Address. In the Serial NMS area, select Enabled to enable the serial port. Then specify the IP Mask, Baud Rate, and Modem Phone Number. Click Apply to save the changes. Click Close.

Trap Configuration Used to configure traps sent from a Network Element to the NMS system. To configure traps sent from Ceragon's NMS to other NMS systems, see Trap Forwarding Configuration Utility at the beginning of this guide. 1. Select Configuration, Management System, Trap Forwarding, or click the Trap Forwarding icon. The Traps Configuration window appears.

CeraView User Guide

57

Traps Configuration Window

2. 3. 4.

In the Managers IP Address area, specify the IP addresses of the managers to which you want traps to be sent. For each manager IP you specify, specify the Trap Port. In the Send Trap for Alarms area, for of Group, you determine which alarms will be sent as SNMP traps to each manager. In each manager column, select the alarm types you want to include for that manager. To select/deselect all traps in a column, click the Select All checkbox at the bottom of the column.

5. 6.

For with Severity, select the severity filter to determine which types of alarms will be forwarded. To select/deselect all alarm types in a column, click the Select All checkbox at the bottom of the column. In the Trap Options area, select Standard traps include serial number if you want trap messages to include the IDU serial number. Select Report local traps of far end IDU if you want remote IDU trap messages to be reported locally. Select Use different ID for each alarm type if you want each type of alarm to receive a unique ID. Select Send clear traps with zero severity if you want to receive information concerning clear traps. Select Send traps with extended alarm information if you want the Alarm ID, origin, and unit from the current alarm table to be added to the end of each FibeAir-related trap.

CeraView User Guide

58

7. 8. 9.

For CLLI (Common Language Location Identifier), enter up to 18 characters that will represent your system ID when traps are sent. For Heartbeat Period, a heartbeat signal will be generated every x minutes (the number you enter) to tell your system that the trap meachnism is working. Click Apply to save the settings.

10. Click Close. In-band Configuration In-band Management refers to a method in which the network management software sends management packets through the same network it is managing. This differs from out-of-band management in which the network management software uses a different network (overlay network) to communicate with the managed elements. The method by which you select the In-band Channels is as follows: Up to 9 In-band channels are avialable for selection in the window (when 4 ODUs are installed). The channels in the upper section (up to 4) represent the radio mapping of the In-band management, and those in the lower section (up to 4) represent the line mapping of the In-band management. An additional virtual mapping channel, PPPoE, is available on the IDC. A total of 1 or 2 channels may be selected for In-band management mapping. If you select 2 channels, you will not be able to select an additional channel. Notes: - Upon a change of the protection configuration from internal to no protection, all In-band channels will be disabled automatically. - After you set the required channels, the window will refresh and display the values in the unit. In some cases, the values will not be the same as those you requested. For example, the virtual mapping channel (PPPoE) is automatically selected if you did not select a line channel. To configure In-Band Management: 1. Select Configuration, Management System, In-band. The In-band Configuration window appears.

CeraView User Guide

59

In-Band Configuration Window

2. 3. 4.

Select In-Band Management Enabled to activate this management method. If you enabled In-Band Management, select the channels you want to use for in-band management data transfer, and select the communication method (DCCR, DCCM, or Proprietary). Click the Netwrk Element Type drop-down list and select the type of element. If you selected Gateway, specify the Gateway Ring Subnet Address and the Gateway Ring Subnet Mask.

5. 6. 7. 8.

For Time To Live, use the up/down arrows to select the desired value. For Network ID, use the up/down arrows to select the ID. Click Apply to save the changes. Click Close.

Neighbors The Neighbors window displays a table of all STM-1 interfaces (radio, line, trib) and their remote connections. 1. Select Configuration, Management System, Neighbors. The Neighbors window appears.

CeraView User Guide

60

Example of Neighbors Window 2. Select Manual in the Detect Mode column to enter the unit's IP address manually. When you enter an IP address, CeraView will try to connect to the unit and learn the Neighbor Type and Interface. If the IP address you entered is not configured or not able to be reached, the Neighbor Type field will display Unknown, and the Neighbor Interface field will list all available options than can be configured. SNMP Configuration 1. Select Configuration, Management System, SNMP Configuration. The SNMP Configuration window appears.

SNMP Configuration Window

2.

For Read Community, enter the community name for read-only access. For Write Community, enter the community name for read-write access. For Trap Community, enter the community name for trap forwarding.

3. 4.

Click Apply to save the settings. Click Close to close the window.

Note: Changes to community settings will take effect only after the unit is reset.

CeraView User Guide

61

NTP Configuration NTP (Network Time Protocol) configuration is performed when an NTP server is used to synchronize network activity. The Network Time Protocol is used to synchronize the time of a computer client or server to another server or reference time source, such as a radio or satellite receiver or modem. It provides accuracies typically within a millisecond on LANs and up to a few tens of milliseconds on WANs relative to Coordinated Universal Time (UTC) via a Global Positioning Service (GPS) receiver, for example. Typical NTP configurations utilize multiple redundant servers and diverse network paths in order to achieve high accuracy and reliability. To configure FibeAir for operation with NTP: 1. Select Configuration, Management System, NTP. The NTP Configuration window appears.

NTP Configuration Window

2. 3. 4. 5. 6. 7.

Enter the IP of the NTP server. For NTP Update Interval, use the up/down arrows to select the amount of time (minutes) between synchronization updates. For Offset from GMT, use the arrow buttons and the drop-down list to select the amount of time required to compensate for offset from the GMT (Greenwich Mean Time). For Daylight Saving Time Offset, click the arrow buttons to set the amount of time required to compensate for daylight saving. For Daylight Saving Time Start, click Configure to set the beginning of the daylight saving time period. For Daylight Saving Time End, click Configure to set the end of the daylight saving time period.

CeraView User Guide

62

8.

Select Enable NTP Authentication for secure access to the NTP server. If you enable NTP, enter the Authentication Public Key, and the Authentication Secret Key numbers.

9.

Click Apply to save the settings.

10. Click Close to close the window.

Alarms Menu
Current Alarms Select Alarms, Current Alarms, or click the Current Alarms icon. The Current Alarms window appears.

Current Alarms Window

Each line in the window describes a different alarm. You can click on a column title to sort the information in the table accordingly. When you move the cursor over a line, a window appears with the details of the alarm, it's probable cause, and the corrective actions to perform. In the Severity Filter area, select one or more alarm severity types to be displayed in the list. The time and date the alarm was triggered appear in the Time and Date column.

CeraView User Guide

63

The color in the Severity column indicates the severity of the alarm, as shown at the top of the alarm list. The source of the alarm appears in the Module column. The unit associated with the alarm is indicated in the Origin column. A description of the alarm appears in the Description column. To save the current alarm list in a file, click Save. To send the alarm list to the printer, click Print. Notes for FibeAir 3200T The window includes alarms for all floors. You can view alarms related to a specific floor by selecting the floor from the drop-down list in the Floor Filter area. If you opened the window using the icon in the main window status panel, the window that appears will be filtered for the selected floor.

Alarm Log Select Alarms, Alarm Log, or click the Alarm Log icon. The Alarm Log window appears.

CeraView User Guide

64

Alarm Log Window

The Alarm Log displays the last 200 alarms that occurred. If the number of alarms exceeds 200, the first alarms will be removed. You can click on a column title to sort the information in the table accordingly. The window displays the following information: Time and Date - The time and date the alarm was triggered. Severity - The severity of the alarm. You can determine which severity levels will be displayed in the window by selecting the levels at the top of the window. Origin - The drawer containing the unit that generated the alarm. Description - A description of the alarm, and its status (RAISED, CLEARED). To clear the alarm list in the window, click Clear Log. To print the alarm list, click Print. To save the alarm list in a file, click Save. Note: The alarms in the window are not saved in a file, unless you click Save.

CeraView User Guide

65

Notes for FibeAir 3200T The window includes alarms for all unit floors. However, if you open the window using the icon in the main window status panel, the window will be filtered for the selected floor. You can view alarms related to a specific floor by selecting the floor from the drop-down list in the Floor Filter area.

Continuous Alarm Logging To save alarms in a continuous logging file, select Alarms, Start Saving Log. In the Choose Alarm Log File window that appears, select the file you want to save the alarms to and click Save. Alarms will be added to the file you selected until you select Stop Saving Log. or exit the application. If you exit CeraView and the log file is still active, you will be notified.

CeraView User Guide

66

Performance Menu
Radio
RSL The RSL Performance Monitoring window displays received signal level values measured over the past 24 hours. 1. Select Performance, Radio, Left/Right, RSL. The RSL Monitoring window appears.

RSL Performance Monitoring Window

Time Elapsed is the current interval in seconds. The value can be between 0 and 900 (15 minutes). Current Min RSL values are the minimum received level measured during the interval. Current Max RSL values are the maximum received level measured during the interval. Threshold Exceeded displays the number of seconds threshold values were exceeded during the current interval.

CeraView User Guide

67

Current MSE displays a value calculated by the agent for Ceragon technical support personnel. Current XPI displays a value calculated by the agent for Ceragon technical support personnel. Doubtful values are values that were not generated during normal system operation. For example, the values may have been generated during a system reset or failure. Unfaded RSL is the theoretical expected RSL value (not the actual value), which can be calculated by the user (as a function of distance, frequency, etc.). The value is used only for reference purposes. RSL Threshold (1 and 2) are values that you can set. When an RSL value exceeds the thresholds you set, the Threshold Exceeded counters at the top of the PM window will display the number of seconds the threshold values were exceeded. Click Save to save the values to a file. Click Print to send the listed values to the printer. Value Table The value table displays RSL values over the last 24 hours. The values are the same as those that appear in the graph, only in table format. The columns show the levels measured during the current interval. The Integrity column indicates whether or not the values received at that time and date are reliable. A red x in the column indicates that the values are not reliable due to a possible power surge or power failure that occurred at that time. The values in this column are indicated in the graph as "Doubtful" (red) values. 2. To view historical RSL values over a one-month period, click History.

CeraView User Guide

68

RSL Historical Window

The values shown in the window are values that were received over the last 30 days. Note that since the current day's data is not complete until the end of the day, its partial data is presented above the table area. Click Save to save the values to a file. Click Print to send the listed values to the printer. TSL The TSL Performance Monitoring window displays details about the transmitted signal level measured every 15 minutes, over the last 24 hours. Select Performance, Radio, Left/Right, TSL. The TSL Monitoring window appears.

CeraView User Guide

69

TSL Performance Monitoring Window

Time Elapsed is the current interval in seconds. The value can be between 0 and 900 (15 minutes). Current Min Set TSL values are the minimum transmitted level measured during the interval. Current Max Set TSL values are the maximum transmitted level measured during the interval. Threshold Exceeded displays the number of seconds the threshold value was exceeded during the current interval. Doubtful values are values that were not generated during normal system operation. For example, the values may have been generated during a system reset or failure. Set TSL Threshold is a value that you can set. When a TSL value exceeds the threshold you set, the Threshold Exceeded field will display the number of seconds the threshold value was exceeded. The format of the value table is similar to the RSL value table described above. Click Save to save the values to a file. Click Print to send the listed values to the printer. Click History to view historical values. The values shown in the window that appears are values that were received over the last 30 days.

CeraView User Guide

70

SDH The SDH Performance Monitoring window displays values measured every 15 minutes, over the last 24 hours. Select Performance, Radio, Left/Right, SDH. The SDH Monitoring window appears.

SDH Performance Monitoring Window

Time Elapsed is the current interval in seconds. The value can be between 0 and 900 (15 minutes). UAS is the Unavailable Seconds value of the current interval. The value can be between 0 and 900 seconds (15 minutes). ES is the number of seconds during which errors occurred. SES is the number of severely errored seconds. BBE is the number of background block errors. OFS is the number of out-of-frame seconds. Doubtful values are values that were not generated during normal system operation. For example, the values may have been generated during a system reset or failure.

CeraView User Guide

71

The format of the value table is similar to the RSL value table described above. Click Save to save the values to a file. Click Print to send the listed values to the printer. Click History to view historical values. The values shown in the window that appears are values that were received over the last 30 days. Tributaries The Tributaries Performance Monitoring window displays values measured every 15 minutes, over the last 24 hours, for the E1/T1 or DS3 interface. Select Performance, Tributaries, E1 # / DS3. The Tributary monitoring window appears.

Tributary Performance Monitoring Window

Time Elapsed is the current interval in seconds. The value can be between 0 and 900 (15 minutes). UAS is the Unavailable Seconds value of the current interval. The value can be between 0 and 900 seconds (15 minutes). ES is the number of seconds during which errors occurred.

CeraView User Guide

72

SES is the number of severely errored seconds. BBE is the number of background block errors. OFS is the number of out-of-frame seconds. Doubtful values are values that were not generated during normal system operation. For example, the values may have been generated during a system reset or failure. The format of the value table is similar to the RSL value table described earlier. Click Save to save the values to a file. Click Print to send the listed values to the printer. Click History to view historical values. The values shown in the window that appears are values that were received over the last 30 days. Cross Connect Select Performance, XC, Carrier #. The Cross Connect monitoring window appears.

Corss Connect Performance Monitoring Window

Time Elapsed is the current interval in seconds. The value can be between 0 and 900 (15 minutes).

CeraView User Guide

73

PSAC - Protection Switch Actual Count The number of occurrences of a switch from the protected channel to the protecting channel. PSAD - Protection Switch Actual Duration The number of seconds the channel is in the switched state for at least a fraction of one second. FSRC - Failed Switch Request Count The number of occurrences of the following events: - A protection switch request is activated on the channel and the protecting channel is not available. - A channel is restored from a protecting channel while a protection switch request is still active on the channel. FSRD - Failed Switch Request Duration The number of seconds for which a protection switch request is detected on the channel carrying regular traffic and the request cannot be serviced. Doubtful values are values that were not generated during normal system operation. For example, the values may have been generated during a system reset or failure. The format of the value table is similar to the RSL value table described earlier. Click Save to save the values to a file. Click Print to send the listed values to the printer. Click History to view historical values. The values shown in the window that appears are values that were received over the last 30 days. Line The Line Performance Monitoring window displays values measured every 15 minutes, over the last 24 hours. Select Performance, Line, Left/Right. The Line monitoring window appears.

CeraView User Guide

74

Line Performance Monitoring Window

Time Elapsed is the current interval in seconds. The value can be between 0 and 900 (15 minutes). UAS is the Unavailable Seconds value of the current interval. The value can be between 0 and 900 seconds (15 minutes). ES is the number of seconds during which errors occurred. SES is the number of severely errored seconds. BBE is the number of background block errors. OFS is the number of out-of-frame seconds. Doubtful values are values that were not generated during normal system operation. For example, the values may have been generated during a system reset or failure. The format of the value table is similar to the RSL value table described earlier. Click Save to save the values to a file. Click Print to send the listed values to the printer. Click History to view historical values. The values shown in the window that appears are values that were received over the last 30 days.

CeraView User Guide

75

Maintenance Menu
Loopback 1. Select Maintenance, Loopback, Left/Right, or click the Left/Right Loopback icon. The Loopback window appears.

Loopback Window for FibeAir with ODU

CeraView User Guide

76

Loopback Window for FibeAir with RFU

Loopback Window for FibeAir 640P

CeraView User Guide

77

2.

Click the upper button on the west side Click the lower button on the west side Click the button on the east side Click the button on the ODU or RFU

to select an internal radio loopback test. to select an external radio loopback test.

to select an internal line loopback test. to select an internal ODU or RFU loopback test.

3.

Set the LoopBack Clear Timeout scale to the amount of time you want the test to run. When a radio or line loopback test is running, a pie display above the timeout scale shows how much time is left for the test (see the figure above).

4. 5.

Click Apply to run the test. When you are done with loopback testing, click Close to close the window. Note that closing the window will not stop the loopback test. To stop a test, unmark it by clicking on the relevant button, and then click Apply.

Software Reset Select Maintenance, Software Reset to reset the software for maintenance purposes, as follows: IDC Left ODC Right ODC Hardware Reset Select Maintenance, Hardware Reset to reset the hardware for maintenance purposes, as follows: IDC Auxiliary Interface Left/Right Modem: Left/Right Mux: Left/Right ODU: Left/Right Drawer: XC Clear PM Data Select this item to reset Performance Monitoring in the unit (the number of available intervals will be 0). The options include: Entire PM Data Clears the performance monitoring log files for both the left and right units. Performs a hardware reset of the Indoor Unit Controller. Performs a hardware reset of the Auxiliary Interface Module (AIM). Performs a hardware reset of the left or right modem. Performs a hardware reset of the left or right multiplexer module. Performs a hardware reset of the ODU for the left or right drawer. Performs a hardware reset of the left or right drawer. Performs a hardware reset of the relevant cross-connect module. Performs a software reset for the Indoor Unit Controller. Performs a software reset for the Left Outdoor Unit Controller. Performs a software reset for the Right Outdoor Unit Controller.

CeraView User Guide

78

Left PM Only Right PM Only

Clears the performance monitoring log files for the left drawer only. Clears the performance monitoring log files for the right drawer only.

Set Default Configuration Select this item to reload the default system configuration. Copy Configuration Select this item to copy a hardware configuration from one source to another. The options include: Auxiliary to IDC - copies the configuration from the auxiliary interface to the IDC. IDC to Auxiliary - copies the configuration from the IDC to the auxiliary interface. Left/Right IDC to Drawer - copies the configuration from the IDC to the drawer. Left/Right Drawer to IDC - copies the configuration from the drawer to the IDC. IDC to XC # - copies the configuration from the IDC to the relevant cross-connect. XC # to IDC - copies the configuration from the relevant cross-connect to the IDC. Force Far End Tx Level Select this item to force the remote Tx level to the value set for the local IDU. Force Far End Mute Off Select this item to enable remote ODU transmission. PRBS Test (for FibeAir 3200T) The PRBS test is designed for maintenance testing of a radio link. When the test is activated, the local modem sends a pseudo-random-binary-sequence to the remote side, and the quality of the link can be evaluated based on the amount of defective blocks detected by the remote (receiving) modem (the larger the amount is, the poorer the radio link quality). To perform a PRBS test, do the following: 1. Select Maintenance, PRBS Test.

CeraView User Guide

79

PRBS Test Window

2. If you prefer not to interrupt traffic, transmit the tested carrier over the protecting channel, and lock the mux to its mate input. 3. Activate the PRBS test in the local subrack (a warning will appear informing you of traffic interruption). 4. Reset the defected block counter in the same carrier in the remote subrack. This will start the counting from zero. 5. Wait for x hours/days depending on the required test time. 6. Check the resulting amount of defective blocks. The value indicates the quality of the link. 7. Stop the test, unlock the mux, and change the cross-connect back to its previous configuration. Note that upon activating the test, a PRBS alarm will be raised in the local subrack. In addition, if you did not perform step 1 above, an LOF alarm will be raised in the remote drawer until the test is stopped. Temporary License The temporary license extends the time period for system usage and supports the maximum system rate, configured in the Multi Rate Multi Constellation (MRMC) window, for one week, or until a permanent license is obtained. You can use the temporary license as long as the counter does not run out. The counter, which is updated every hour, is active only when the temporary license is enabled. If you disable the temporary license, the counter will not be updated. The license is drawer-specific and is enabled for each drawer separately. When the counter of the temporary license reaches 0, the temporary license for the specific drawer will be terminated. Once enabled, a message appears at the bottom of the Main Window, indicating the time left for the license.

In addition, an event will appear in the Current Alarms list, informing you about the license. If you select Disable, the selected drawer will be reset and the MRMC settings in effect before the temporary license option was active, will be restored.

CeraView User Guide

80

When a permanent license is acquired, the temporary license will automatically be disabled, without affecting the drawer's traffic (the drawer will not be reset). For Internal Protection In internal protection mode, the temporary license operates as follows: As with other configuration values, enabling the temporary license for a drawer will also enable it for the other drawer, and both period counters for the drawers will be activated. As in non-protection mode, if you disable the temporary license, or let the counter end, both drawers will be reset, and the previously selected MRMC will be restored for both drawers. In the event that the two drawers have different temporary counters (which may occur when the IDU was previously operated in non-protection mode, and the temporary license was enabled for only one of the drawers), the lowest counter will determine the time period. The drawer with lowest counter will automatically be reset when the counter ends, and the previous MRMC value will be restored for both drawers. Important! In internal protection mode, a temporary license should not be enabled for an IDU in which one of the drawers has a counter equal to zero. Doing so may cause erratic IDU behavior.

CeraView User Guide

81

Protection for FibeAir 1500P/640P


Protection Type 1. Select Protection, H/W Protection, H/W Protection Type. The Protection Type window appears.

Protection Type Window

2.

Select one of the following options: Protection Disabled - to disable protection. Internal Protection, Dual Drawer - to activate internal protection, whereby the left drawer will function as the active (primary) unit and the right drawer will function as the standby (secondary) unit. External Protection, Single Drawer - to activate external protection in a 1+1 configuration. The protection mechanism will operate only on the right drawers of the IDU. Left drawers, if they exist, will be muted. External Protection, Dual Drawer - to activate external protection, whereby the IDU will be linked for protection purposes to another IDU. When this option is used, the main window will include tabs at the top showing the active and standby units. Note: When internal or external protection is configured, icons representing the type of protection will appear in the Status Panel on the right side of the main CeraView window. For an explanation of the icons, see the Status Panel Icons section at the beginning of this guide.

3. 4.

Click Apply to save the settings. Click Close to close the window.

Protection Configuration 1. Select Protection, H/W Protection, H/W Protection Configuration. The Protection Configuration window appears.

CeraView User Guide

82

Protection Configration Window

2. 3.

In the Protection Switch Criteria area, select the criteria that will cause a protection switch (only if Off is selected for Protection Lockout). In the Line Output area, select either a single or dual line output. In Single STM-1 Line Output mode, an optical splitter is used and the transmission standby channel is muted. This mode is used when the external SDH multiplexer does not support an MSP 1+1 protection mode for two STM-1 optical interfaces. In Dual STM-1 Line Output mode, a direct connection is made via two STM-1 channels to the external SDH multiplexer. This mode is used when the external SDH multiplexer supports MSP 1+1 protection mode for two STM-1 optical interfaces. In this configuration, both optical STM-1 transmitters in the radio are active and the multiplexer chooses the one transmitting the best quality signals.

4. 5.

Click Apply to save the settings. Click Close to close the window.

Diversity Configuration 1. Select Protection, Diversity, Diversity Configuration to configure Diversity parameters. The Diversity Configuration window appears.

Diversity Configuration Window

2.

In the Diversity Type area, select either Space or Frequency diversity.

CeraView User Guide

83

3.

For Revertive, select Enabled if you want normal traffic on the protection path to be switched back to the original path after it recovers from a fault. Revertive mode may be required to support specific services, whereby the shortest physical route offers better performance. If you dont select Revertive, no switching to the original fault-cleared path will be performed to prevent unnecessary traffic hits and management event reports.

4. 5. 6. 7.

If you selected Enabled, for Hold off Time use the arrow buttons to set the delay period between fault detection and path switching. The value can be from 0 to 10 seconds. The default is 0 seconds. The Receiver Status area shows the last radio from which data was received. Click Apply to save the settings. Click Close to close the window.

Protection Commands Copy Configuration This option causes the configuration of one unit (left or right) to be copied to the other. 1. Select Protection, H/W Protection, Commands, Copy Configuration, IDU to Mate/Left to Mate/Right to Mate. IDU to Mate will copy the IDU configuration to another IDU. Right to Mate will copy the right drawer configuration to the left drawer. Left to Mate will copy the left drawer configuration to the right drawer. 2. In the confirmation message that appears, click Yes.

Request Switch This option requests a switch between the active and standby radios. 1. 2. Select Protection, H/W Protection, Commands, Request Switch. In the confirmation message that appears, click Yes.

Force Switch This option forces a switch between the active and standby radios. 1. 2. 3. Select Protection, H/W Protection, Commands, Force, Force Switch/Clear Force. In the confirmation message that appears, click Yes. To disable the Force Switch option, select Clear Force.

Lockout This option prevents protection switching from occurring. 1. 2. 3. Select Protection, H/W Protection, Commands, Lockout, Lockout/Clear Lockout. In the confirmation message that appears, click Yes. To disable the Lockout option, select Clear Lockout.

CeraView User Guide

84

Diversity Protection Commands Request Switch This option requests a switch between the active and standby radios. 1. 2. Select Protection, Diversity, Commands, Request Switch. In the confirmation message that appears, click Yes.

Lockout This option prevents protection switching from occurring. 1. For FibeAir, select Protection, Diversity, Commands, Lockout, Lock to Left Radio/Lock to Right Radio. For FibeAir 311 Mbps, select Protection, Diversity, Commands, Lockout, Lock to Self Radio/Lock to Mate Radio. 2. 3. In the confirmation message that appears, click Yes. To disable the Lockout option, select Clear Lockout.

Protection for FibeAir 3200T


Setting up the N+1 Configuration 1. Select Protection, H/W protection, H/W protection type.

H/W Protection Type Window 2. Click the Protection Topology drop-down list and select the required configuration, as follows: HSB 1+1 - the upper floor is activated with two drawers that protect each other, while the standby drawer is muted, as in FibeAir 1500P with internal protection.

CeraView User Guide

85

1+1 - the N+1 algorithm is activated. The upper floor includes two carriers, whereby the left one is the protecting carrier. 2+1 - three separate carriers with one protecting. 3+1 - four separate carriers with one protecting. 4+1 - five separate carriers with one protecting. 5+1 - cascade mode, six separate carriers with one protecting. 6+1 - cascade mode, seven separate carriers with one protecting. 7+1 - cascade mode, eight separate carriers with one protecting. 8+1 - cascade mode, nine separate carriers with one protecting. 9+1 - cascade mode, ten separate carriers with one protecting. Note that the protecting carrier is the same in all topologies. 3. Select Protection, H/W protection, H/W protection configuration. The following window will appear if the protection type you selected was between 1+1 and 9+1 (otherwise, the FibeAir 1500P protection configuration window will appear).

H/W Protection Configuration Window

CeraView User Guide

86

4. 5. 6.

Select Protection Enabled. Select Switch On Early Warning if you want the switch to occur when the system reaches an MSE of -28. For Revertive Link, select the carrier that will be transmitted over the protecting carrier when no other fault exists in the system. Your selection will be used in cases where a switch occurs and then the system returns to normal operation. Examples: Revertive = Extra Traffic If a radio or hardware fault occurs at site A, a request is sent to site B to transmit the faulty carrier also through the protecting channel. The switch that is performed is Hitless (up to 10 mS), and the Extra Traffic channel will no longer exist on both sides by definition (generally, the system can protect up to two faults at different sides). The moment the alarm is cleared, the +1 (protecting) modem will refer to the input from the +1 (extra traffic) MUX. Revertive = None The last protected MUX (the carrier in which the last protection switch occurred) will receive two inputs: its own modem, and the +1 modem. The Extra Traffic channel will not exist. Data to the other MUX cards (for each of the defined carriers) will be received from its own modem until the first hitless fault. When the fault is cleared, the last protected MUX will receive data from two sources: the +1 modem, and its own modem, meaning the next fault in this channel will be errorless (if other carriers fail, the switch performed will be hitless). Revertive = Carrier#X MUX number X will always receive two sources: the +1, and its own, unless there is a fault in another carrier. If MUX number X receives two sources, and a fault occurs, the switch is errorless. In all the other cases, the switch is hitless.

7. 8.

For Revertive Switch Timeout, specify the period (in seconds) after which the revertive mode will be activated. For High Priority Threshold, click the drop-down list and select the minimum fault severity criteria. If the crietria is met, the system will perform a switch to the channel you chose as high priority, rather than switch to a normal priority channel (even if its fault severity is higher). The options include: Baseband Loss of Frame, Baseband Excessive BER, Baseband Signal Degrade, and Early Warning.

9.

In the priority table, designate the high priority channel(s). A high priority channel will be switched first when the criteria chosen for the threshold is met, even if a higher severity fault occurs in a lower priority channel. The Priority Level options include: - Normal - regular operation according to the N+1 mechanism - High Priority - Not Protected - stand-alone channel without protection

CeraView User Guide

87