Material we will cover
Monitoring:
-
Tile busy
-
Tile trips and status
-
Data quality: digital errors
Calibrations
Other information
DAQ = Data AcQuisition
DQM = Data Quality Monitoring
DCS = Detector Control System
2 Friday, July 29, 2011
What to check before taking shifts (I)
To access the Atlas Control Room (ACR) you need :
Safety courses 1, 2, 3, 4A
ATLAS Control room ATL_CR
Check your access detail sheet on EDH
https://edh.cern.ch/Document/General/ACRQ
It should look like :
More informations on access :
https://twiki.cern.ch/twiki/bin/view/Atlas/TileCalShifterPages
For newcomers : check
your access rights at least
2 weeks before your shift!
Request your access via EDH. More information in this twiki
https://twiki.cern.ch/twiki/bin/viewauth/Atlas/OtpAtlasControlRoomShifts
For newcomers: check
your access rights at
least 2 weeks before
your shift!
3 Friday, July 29, 2011
Exercise Self-training
Ask the previous Tile Shifter for a brieng and the Shift Leader for the plan of
the day
Log-in to RunCom.
Voltage trips
Temperature alarms
Yellow = warning.
Red = Alarm!
https://atlasop.cern.ch/twiki/bin/view/Main/ShifterToolsDCS
9 Friday, July 29, 2011
L1Calo Map
Tile Modules
Masked
Tile Modules/
Channels
without signal
A side C side
10 Friday, July 29, 2011
L1 Calo Map
C side A side
11 Friday, July 29, 2011
Partition
Partitions can exist in parallel, as long as they dont try to use the
same part of the detector.
-
TILE partition: We use it for calibrations. You control it!
-
ATLAS partition: Run Manager uses this for collisions,
cosmics, or any other combined runs. You only watch.
Examples: ATLAS partition, TILE partition.
12 Friday, July 29, 2011
Monitor/Start Partition
MRS
BUSY
OHP
DQMD
...
DAQPanel: Set partition info & laun
1
2
3
1. Congure, from whiteboard.
2. Read Info.
3. Launch the panel you need.
13 Friday, July 29, 2011
How to monitor ATLAS partition?
Keywords
-
Digital errors
-
Occupancy plots
-
Noisy channels
-
Masked channels
-
Known problems (in the whiteboard)
23 Friday, July 29, 2011
24 Friday, July 29, 2011
25
New histogram to monitor digital errors
Last bin is always
current LB
Time when module
was recovered
Fraction of
ANY type of
digital errors
integrates
over LB
One histogram per module and run
Browser:TileGATH-EF->SHIFT->DMUErrors->FracTileDigiErrorsEBA07
25 Friday, July 29, 2011
Back - up
26
TRIP LBC04
5 lumiblocks ago
TRIP LBA45
75 lumiblocks ago
EBC22
Known problem see
whiteboard
LBC03
Small percentage,
just report this in the
e-log
26 Friday, July 29, 2011
27 Friday, July 29, 2011
28 Friday, July 29, 2011
29 Friday, July 29, 2011
30 Friday, July 29, 2011
31 Friday, July 29, 2011
DCS &
Detector Control System
Keywords
-
High Voltage
-
Low Voltage Power Supply (LVPS or fLVPS, where f
is for nger )
-
Power trip!
-
Temperature
-
Alarm Panel
32 Friday, July 29, 2011
FSM panel
Legend
Clickable / Browsable!
33 Friday, July 29, 2011
Alarm screen
34 Friday, July 29, 2011
!"#$%&'(&'$)%*'+,-$+*+./$
01+$23"$4+)1,+'-$'%$'5-$6%..-7(%48-4'$/%8&*-$+48$8.+9-.$
:(-4$%&'(&'$)%*'+,-$(*%'$;%.$+<-6'-8$!"#$
35 Friday, July 29, 2011
!"#$%&'(&'$)%*'+,-$+*+./$012$
3%$'%$45"$(+6-*$+67$8*98:$;&<%6$!"#$%&#'()*$
=.9'-$+6$-*%,$-6'.>$?9'@$+,&-./$+67$+A-8'-7$012B$96798+'-$
8&..-6'$)%*'+,-$+67$%AC-'$)+*&-D$E@-8:$!"#$96$'@-$!"#$%&#'()*$
36 Friday, July 29, 2011
1rlpped Lv examples
A message ln Alarm panel !"#$%&'"#(()* wlll appear!
uCS Lakes auLomauc acuons and recovers Lv of Lhe Lrlpped modules
- lf module falls Lo sLarL +&,-). consecuuvely, auLomauc acuon ls .'/(()*&
AuLomauc recovery ls only for Lhe Lv.
37 Friday, July 29, 2011
Calibrations
TileCal TileCalibration
Monitoring is not enable so,
in case histograms need to
be check you should take
manually calibration
40 Friday, July 29, 2011
We use TILE partition for calibrations
Conguration from Whiteboard.
Her we dont just monitor; we START the partition.
Step-by-step in the twiki. Please skim it.
41 Friday, July 29, 2011
To log or not to log?
When to write an e-log:
End of each run.
Include detector and data quality information.
For any significant problem requiring the intervention of an expert.
Power cycle is a significant problem, please report this
At the end of your shift, make a summary.
Rough chronology of what was done, new problems, general comments.
The goal is to have one e-log report per run for routine operations, one
shift summary, and additional posts only in case of serious problems.
E-log TEMPLATES on the whiteboard
https://atlasop.cern.ch/twiki/bin/view/Main/
NewTileCalorimeterOperationManualShifter
42 Friday, July 29, 2011
Hot issues
Module Trips:
-
Look into FSM and ALARM panel to identify if a module trips and auto-recovers.
-
Check in FSM if module is ON again.
-
Check MRS for auto-reconguration is launched (with 3-5 minutes after module is
ON).
-
Check L1Calo for auto-reconguration succeeds.
-
Check RITMO for increasing number of discard events, if that is the case:
re-congure again:
Be prepared!
https://atlasop.cern.ch/twiki/bin/view/Main/TroubleShooting
47 Friday, July 29, 2011
More information
48 Friday, July 29, 2011
TileLBA_resetshafts
This application is
ABSENT during
RUNNING
is OK it should
be like this
49 Friday, July 29, 2011
Masking a super-drawer
50 Friday, July 29, 2011
ECR Mismatch
51 Friday, July 29, 2011
TileCal
52 Friday, July 29, 2011
Basic electroncs
Basics of Tile Electronics
In order to properly understand the various problems that can occur in TileCal, it is important to understand the basics of the TileCal front end
electronics. In case of a trip of a module or barrel, the shifter must be able to identify the nature of the trip and take appropriate action. The
nature of the trip is given by the error messages in the DCS alarm panel and the colored status display on the DCS.
Each TileCal drawer has a High Voltage (830V) input that provides the voltage bias for all pmts in that drawer.
In addition, low voltage is supplied to each drawer via a two-tier system:
1. A 200 V Bulk Power Supply channel serves four tile drawers. These are the represented by the innermost ring of each barrel in the DCS
schematic.
2. The fLVPS (nger Low Voltage Power Supply) transforms the 200V into 8 different output voltages necessary for the functioning of the
TileCal Front-End electronics inside Super-Drawer(S-D). The fLVPS provides two sets of voltages: a low voltage for the readout
electronics (digitizers and motherboard) on on side of S-D and the low voltage for the High Voltage distributor system on the other side of
S-D. These two sets - "MB_side of fLVPS" and "HV_side of fLVPS" has to be distinguish / mentioned in the case of fLVPS trip.
Given this, drawer trips can be classied as follows:
Trip of the HV input channel to the TileCal drawer. One drawer becomes nonoperational and must be restarted by the DCS expert.
Trip of the fLVPS. One TileCal module becomes nonoperational and must be restarted by the DCS expert and in then the case of "MB_side
of fLVPS" recongured for data taking by the DAQ expert.
A drawer can still be operated in so called "emergency mode" if the "HV_side" of the fLVPS is tripped.
Trip of the 200V power supply. In this case, four drawers are made inoperable and each one must be treated as in a fLVPS trip. The DCS
expert must restart the 200 V Bulk Power Supply channel and fLVPS in all 4 drawers and the DAQ expert must recongure all 4 drawers for data taking.
53 Friday, July 29, 2011