You are on page 1of 10

BTS Alarms and Troubleshooting Definition In a network, the Maintenance System has a significant role in maintaining correct network

operation and ensuring that all network elements function correctly. The maintenance system generates a notification in case there is some: Fault Misbehaved activity Some abnormal situation during the operation of any network element This notification is called an ALARM. Types of alarms The alarms arriving in the Network can be divided into various classes depending upon the criterion chosen.

Based on Network Architecture the alarms are divided into three categories:

Network Architecture i. Base Station Subsystem Alarms

Alarms related to the radio access part of the Network come under this category.

These include alarms on BTS, Cells within BTS, transmission alarms (between BSC and BTS or between BTSs themselves), BSC alarms, TCSM alarms and external alarms on all these elements. Examples:

Alarms groups and numbers The Alarm Reference documentation consists of alarm printouts and diagnosis reports. The alarms have been divided into four groups, and each of them is described in a dedicated piece of documentation. The alarms are numbered in ascending order as follows: Table: Alarm groups and numbers

Reasons for alarm triggering Tramsmission Problem Cable/Connector Mux M/W ODU/IDU M/W fading/interference Configuration problem Hardware problem at BTS. VSWR/loose cables at BTS Configuration Problem in BSC. Hardware Problem at BSC. Configuration Problem in BTS.

Equipment failure(BSC/BTS) Equipment failure(BSC/BTS) Configuration Problem in MSC. Configuration Problem in SGSN. Wrong RF parameters.

Alarm in BTS What is it? Any alarm which is generated from functional unit of BSC caused by BTS Network Elements is called a BTS alarm

Example of the Alarms


SNo.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Ref
ENVIR ENVIR ENVIR EQUIPM EQUIPM EQUIPM EQUIPM EQUIPM PROCES EQUIPM EQUIPM COMM COMM ENVIR ENVIR

Alarms No.
7405 7409 7410 7600 7601 7604 7606 7607 7616 7701 7704 7705 7706 7711 7712

Service_affecting (SA)
YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES HIGH ROOM TEMPERATURE FIRE ALARM LOW VOLTAGE D.C BCF FAULTY BCF OPERATION DEGRADED BTS OPERATION DEGRADED TRX FAULTY TRX OPERATION DEGRADED

Details

OSCILLATOR ADJUSTING TEMPORARILY INTERRUPTED BCF INITIALIZATION PCM FAILURE LAPD FAILURE BTS O&M LINK FAILURE WORKING FULL RATE TCH RATIO BELOW THRESHOLD WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD

16 17 18

PROCES ENVIR COMM

7715 7717 7723

YES YES YES

CONTINUOUS RESTARTS OF BCF/TRX WORKING HALF RATE TCH RATIO BELOW THRESHOLD FAILURE IN SENDING SYSTEM INFORMATION TO BTS SITE

19 20 21

ENVIR EQUIPM PROCES

7724 7725 7729

YES YES YES

CONFLICT BETWEEN BSS RADIO NETWORK DATABASE AND CALL CONTROL TRAFFIC CHANNEL ACTIVATION FAILURE RADIO NETWORK RECOVERY FAILED

22 23 24 25

PROCES QUAL QUAL QUAL

7737 7738 7743 7744

YES YES YES YES

INCONSISTENT DATA IN RADIO RESOURCE MANAGEMENT STATE FILES BTS WITH NO TRANSACTIONS MEAN HOLDING TIME BELOW DEFINED THRESHOLD EXCESSIVE TCH INTERFERENCE