Test case serial numberError! Reference source not found.

Test Project: MSOFTX3000V200C03SPH219 Patch Installation Sub ProjectSystem automatically isolate fault board in case of double fabric fault Test objectTo verify protect solution provide by patch Reference <<OSTA2.0 Information Collection Instructor V2.7>> Prediction Site works well, there are no communication alarm about board Test environment configuration At least two process boards (1 pair) in the subrack and it work normal. Test steps 1 SOL login SMM according to section 1.3 of <<OSTA2.0 Information Collection Instructor V2.7>> 2 Shutdown the fabric port of slot #1 at SWU slot #6 (If you process board on other slot, please change the corresponding selection) (1) Select slot #6(SWU 0) input 7 (*Since physical slot is numbered from 1, it is deferent with logical slot number, so logical slot #6 is physical slot #7) (2) Select GE port-input 2

(3) Query corresponding port number of slot #1 at SWU0 Execute display port-connection-relationships command

It shows the corresponding fabric port of slot #1 is: G0/9, and write down it. (*Since physical slot is numbered from 1, it is deferent with logical slot number, so logical slot #1 is physical slot #2) (4) Execute system-view and inter G0/9 command to configure the port. And then execute shutdown command:

3 Press Ctrl+R return to slot select interface, and then select 8. This time we shutdown the fabric port of slot 1# at SWU slot #7. It is same with step 2. 4 In 5 minutes, the process board slot #1 is power off automatically and all process is swapped to assistant board (Slot 0#) except the singling handling process(BSG and IFM) 5 After slot #1 is power off automatically, make a call test

6 Restore the double fabric port communication: same as step 2 and step 3, the different is last execute undo shutdown command instead of shutdown command

7 On the device pane, right click the powered off board, and power on the board 8 Use DSP PORT/DSP PORTSTAT MML commands to check the SWU0 and SWU1 is both work well: to confirm the port of SWU boards is work normal and the send and receive traffic are increasing on both base and fabric port, while the corresponding process board are power on and work well. Correct result 1 After shutdown a fabric port of slot #1 at SWU0, the alarm ALM-1023 Board Port Fault appeared 2 After shutdown fabric port of slot #1 at both SWU0 and SWU1, the alarm ALM-6418 Communication Failure Between Boards appeared in 1 minutes 3 The slot #1 can be power off automatically in 5 minutes after shutdown fabric port of slot #1 at both SWU0 and SWU1 4 All process is swapped to assistant board (Slot #0) except the singling handling process(BSG and IFM) 5 Test call is success while the slot #1 board is shutdown