RESIDENTIALINSPECTIONCHECKLISTS

2009

Visit the virtual information kiosk VIK at: cityofcarrollton.com/VIK

Table of Contents

SUBJECT

INSPECTION

Required Inspections by Permit Type Reference of Abbreviations Temporary Electrical Pole/SWPPP......................................................................................1011 Pool Electrical Bond ............................................................................................................1012 Sewer....................................................................................................................................1021 Water Service.......................................................................................................................1022 Gas Wrap/Service ................................................................................................................1023 Lawn Sprinkler.....................................................................................................................1024 Pool P-Trap ..........................................................................................................................1029 Retaining Wall .....................................................................................................................1041 Sidewalks and Approach......................................................................................................1056 Ham Antenna .......................................................................................................................1072 Fence ....................................................................................................................................1090 Foundation Only ..................................................................................................................2001 Plumbing Rough/Energy......................................................................................................2020 Gas Rough and Test .............................................................................................................3021 Pre-Brick ..............................................................................................................................3042 Plumbing Top Out/HVAC Rough/Gas Test/Energy............................................................3065 Electrical Rough/Frame/Building/Energy, Building and Electrical ....................................3066 Insulation..............................................................................................................................3067 Roof Final ............................................................................................................................4003 Utility Release/Plumbing/HVAC/Energy Final...................................................................4005 Pool Work Final...................................................................................................................4042 Electrical/Building/Energy Final, Electrical and Building ..................................................4063 Clean & Show/Construction Heat/Electric Service .............................................................6015 Clean & Show/Construction Heat/Gas Service ...................................................................6020 Clean & Show/Construction Heat/Gas & Electric Service..................................................6060 General Check/Follow-up....................................................................................................7000

BUILDING INSPECTION BldgInsp@cityofcarrollton.com 1945 E. Jackson Road | Carrollton, Texas 75006 | P.O. Box 110535 | Carrollton, TX 75011-0535 Phone: 972/466-3225 | Fax: 972/466-3220

Required Inspections by Permit Type

ELECTRICAL 1011 - Temporary Electrical Pole/SWPPP 3066 - Electrical Rough/Frame/Building/Energy, Building and Electrical 4063 - Electrical/Building/Energy Final, Electrical and Building FENCE 1090 Fence HAM ANTENNA 1072 - Ham Antenna LAWN SPRINKLER 1024 Lawn Sprinkler MECHANICAL 3065 - Plumbing Top Out/HVAC Rough/Gas Test/Energy 4005 - Utility Release/Plumbing/HVAC/Energy Final PLUMBING 1021 Sewer 1022 - Water Service 1023 - Gas Wrap/Service 2020 Plumbing Rough/Energy 3065 - Plumbing Top Out/HVAC Rough/Gas Test/Energy 4005 - Utility Release/Plumbing/HVAC/Energy Final POOLS 1012 Pool Electrical Bond 1029 - Pool P Trap 4042 - Pool Work Final RETAINING WALL 1041 - Retaining Wall SINGLE FAMILY DWELLING 2020 - Plumbing Rough/Energy 2001 Foundation Only 3065 - Plumbing Top Out/HVAC Rough/Gas Test/Energy 3066 - Electrical Rough/Frame/Building/Energy, Building and Electrical 3067 - Insulation 4005 - Utility Release/Plumbing/HVAC/Energy Final 4063 - Electrical/Building/Energy Final, Electrical and Building

Reference of Abbreviations

The following is a reference list of some abbreviations/symbols used in this handbook of inspection checklists. Abbreviations are to be read as singular/plural in context with material. Any reference to a code or ordinance is to be interpreted as the latest version available of that code or ordinance. Periods have been eliminated in abbreviations for ease in reading. A/C Art CDO CFC cfm Ch COG CSC CZO Dwg GDS Mfg NCTCOG NEC Ord p pp psi Sec Specs Std Subdv Tbl IMC IPC Air Conditioning Article Carrollton Drainage Ordinance Carrollton Fire Code Cubic Feet per Minute Chapter See Amendments in Ordinance No. 2024 Carrollton Sign Code (Carrollton) Comprehensive Zoning Ordinance Drawing General Design Standards Manufacturing North Central Texas Council of Governments National Electric Code Ordinance Page Pages Pounds per Square Inch Section Specifications Standard Subdivision Table International Mechanical Code International Plumbing Code

Temporary Electrical Pole/SWPPP Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Panel grounded and bonded Breaker/outlet requirements-sizing for outlets used Wire sizes and insulation No open holes / to remain water tight Unused breaker openings filled Clearances: 18 above traffic for overhead drop. Distance from public property R.O.W Raceway used and installed Weather resistant receptacles 115-250 volt GFCI Protection / in use covers for exposed outlets Address Bracing: 45 degrees to support pole CODE 2008 NEC 2008 NEC 2008 NEC 2008 NEC 2008 NEC 2008 NEC SECTION 250-28 250-52&53 210-19 310-16 314-17 408.7 225-18 230-50 230-54 406.8 406.8 505 600

2008 NEC 2008 NEC 2008 NEC 2006 IRC Encore service guidelines

SWPPP Inspection Checklist A. Erosion controls are to be in place at the temporary electric pole inspection. B. Erosion control fencing or soil stabilization fabric must be installed in an approved manner and maintained throughout the construction project until the Utility Release/Plumbing/ HVAC final inspections. C. Large piles of dirt are required to be protected with erosion control fencing, NOT soil stabilization fabric. D. Erosion control protection should be proactively maintained at least once a week. E. Storm water inlet protection F. 50 feet rock entryway on commercial projects.

Temporary Electrical Pole/SWPPP 1011

Pool Electrical Bond Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Grounding with minimum #8 ground wire around deck with ground clamps and all metal with 5 Grounding of copper conduit for pool lights/fixtures Position of plugs in relation to pool sides Low voltage lighting / transformer ground run to equipment ground to panel CODE 2008 NEC 2008 NEC 2008 NEC 2008 NEC SECTION 680-26 680-23 680-22 680.24

Pool Electrical Bond 1012

Sewer Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM CODE 2006 IRC 2006 IPC Technical Policy for SDR 17 Trenchless pipe 2006 IRC 2006 IPC 2006 IRC 2006 IPC SECTION

Pipe materials

P3002 702

Pipe sizes Grade of pipe

P3005 710 P3005 Table 704.1

Sewer 1021

Water Service Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Pipe materials NTCOG Amendment (no polybutylene pipe allowed) Pipe sizes Pressure test CODE 2006 IRC 2006 IPC 2006 IRC 2006 IPC 2006 IRC 2006 IPC SECTION P2904 605 P2903 604.10 P2503 107, 312

Water Service 1022

Gas Wrap/Service Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Pipe materials Pipe sizes Pressure test (gas) NTCOG Amendments Connections/Joints Tracer wire for non-metallic piping CODE 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC Carrollton Policy 2006 IRC 2006 IFGC G2414.8 404.8 SECTION G2413 403 G2413 402 G2417 406 G2414 Ch. 4 G2415.14.3 404.14.3 G2415.9 404.9 G2414.6.1 Ch. 4 G2416 405

Pipe depth NTCOG Amendments

Gas risers Gas pipes not to be bent or strained Separate ditch for gas piping Protection from corrosion

Gas Wrap/Service 1023

Irrigation Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Check that city approved plans are on site. Approved back flow prevention device required with y strainer installed before device. Full port ball type isolation valve between meter and back flow device. Test cocks on B/F device are to be plugged with threaded plugs. Installed min. 3 ft. from water service on customer side of property line. Master valve (if required) installed on discharge side of B/F device (full port ball type valve). Check location of controllers and sensors (rain/freeze); each controller must be labeled with installers name and company name, license number, telephone number and warranty period. Check location and water emission devices, valves (zone, master, and isolation). Check all underground wiring for UL burial rating and sizing to manufacturers specifications; all wire splices must be moisture proof. All wiring is buried min. 6 inches. Check PVC piping for sizing, rating, installation and depth (min. 6 inches). Pop up water emission devices must be installed a min. 4 inches from hardscape and direct flow away. CODE House bill 1656 SECTION

House bill 1656

House bill 1656

House bill 1656

House bill 1656

House bill 1656 House bill 1656 and 2006 IPC House bill 1656

Section 605

NOTE: Double check backflow prevention permitted in ground if protected by a box.

Irrigation Inspection 1024

Pool P-Trap Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM P-Trap for pools/spas with air break 1 " minimum backwash/drain pipe CODE Carrollton Policy Carrollton Policy SECTION

Pool P-Trap 1029

Retaining Wall Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Retaining walls which do not require a permit are not inspected. If under 4 feet from the bottom of footing to the top Inspect based on engineered approved plans for retaining walls requiring permit CODE SECTION

2006 IRC

R105.2

2006 IBC

1610.1

Retaining Wall 1041

Sidewalks and Approach Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Sand cushion for leveling only 1 (sidewalks only) Concrete thickness: Sidewalks/ driveways Location of sidewalk with respect to street and other existing sidewalk Width of sidewalk is 4 or 5 Tooling joints spacing Construction joint requirements Expansion joint spacing (no tear off strips allowed in the sidewalks) Expansion joint materials Five foot flare instead of radius and curb omission for approaches attached to alleys Reinforcing steel Storm drain inlet and separation from approach Location of driveway from intersection 30 Residential or Alley 40 Collector / Industrial 50 Residential Arterial Bollards for thin brick wall required? Note on this inspection if needed. CODE GDS 2007 GDS 2007 GDS 2007 GDS 2007 GDS 2007 GDS 2007 GDS 2007 GDS 2007 GDS 2007 GDS 2007 GDS 2007 SECTION P-17 P-16, P-17 P-17 P-17 P-17 P-11, P-16, P-17 P-12, P-17 P-16, P-17 P-16 P-11, P-16, P-17 D-1

Driveway Ord

Ord 1604 as amended

GDS 2007

M-4

Sidewalks and Approach 1056

Ham Antenna Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Anchor tie and foundations per approved plans and specifications Location of antenna (allowed only behind the main building Location of antenna in the back yard Prohibited location of guy wire anchors Height of anchor points Setback from property lines and right of way Maximum height Fence or anti-climb devices Attachments prohibited CODE CZO CZO CZO CZO CZO CZO CZO CZO CZO SECTION Art XXVIII Sec D Art XXVIII Sec D Art XXVIII Sec D Art XXVIII Sec D Art XXVIII Sec D Art XXVIII Sec D Art XXVIII Sec D Art XXVIII Sec D Art XXVIII Sec D

NOTE: Lintels installation occurs after the pre-brick inspection and is the responsibility of the contractors.

Ham Antenna 1072

Fence Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Proper setback from drainage easements Proper height restriction for front yards or certain corner lots (key lots) 3' front yards, 4' key lots Proper requirements for pool enclosure Gates across driveways as a pool enclosure Zero lot lines (check CZO) Gates across driveways (electric) If electric need inspection / burial depth and conduits secured / gfci needed ? Gates across driveways (manual) Proper location for visibility from streets & alleys No metal, barbed wire, or electric fencing permitted. Exception: Wrought iron is allowed. CODE CZO CZO 2006 IRC CZO Technical Policy CZO Technical Policy 2008 NEC Technical Policy Visibility Ord. CZO Ord. 2803 SECTION XXV 11-12 A-D XXVI-A Appendix G XXVII.7 Sec V UBC CAAB ruling Article VII Pages 88-90 Sec V -UBC 300.5 Conduit type 210.8 Sec. I 49 Ord. 1325 as amended Article XXV Sec 11 Sec 92-10

Note: CZO 3/16/04 version

Fence 1090

Foundation Only Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Inspect based on engineered plans: - Reinforcement size and spacing - Reinforcement supports (chairs) - Concrete thickness - Beam spacings and depth/width - Debris and mud and water on slab and beams Read permit for special notes such as minimum finished floor elevations. Wrap copper water lines Provide protection for any horizontal plumbing pipe embedded in concrete along the length of the beams Driveway not allowed to street if alley exists Garage not allowed to face streets certain exceptions may be applicable Driveway separation from intersections Has the lot grade been drastically changed by cuts, fill, or other obstruction which may alter subdivision drainage patterns from what was accepted by Carrollton Engineering Department? CODE SECTION

2006 IRC

R109.1

2006 IRC 2006 IRC CSO Ord. Driveway Ord.

P2603 P2603.2.1 Technical Policy Article X 2402 Ord. 1604 as amended Ord. 1964 as amended

Carrollton Drainage Ord.

NOTE: Effective May 1, 2003, all foundation inspections must have an engineers inspection letter of approval.

Foundation Only 2001

Plumbing Rough/Energy Inspection Checklist p. 1 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Check for setback survey Drainage piping materials Drainage pipe installation Drainage pipe joints Drainage pipe slope Drainage system sizing Drainage prohibited items CODE CZO 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC SECTION Use Districts P3002 P3005.1 P3003 P3005.4.2 P3005.4 P3003 P3005.1.5 P3005.2.11 P3005.2.3 P3005.2.10 P3005.2.9 P3005.2 P3008 P3102 P3201 P3201.7 P2903.6 P2903.8.1

Drainage system clean outs

2006 IRC

Backwater valves Fixtures stack vented P-trap installation requirements P-trap sizing Water distribution Water manifold sizing 2 Hose bibs required on SFD ( front/side and rear) 1 required on Town houses and Condo's (rear) Water piping materials Polybutylene Pipe not allowed ( COG Amend.) Trenching, excavation, and backfill Back flow prevention

2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC COC Technical Policy 2006 IRC 2006 IRC 2006 IRC

P2904 P2604 P2902

Plumbing Rough/Energy p. 1 of 2 2020

Plumbing Rough/Energy Inspection Checklist p. 2 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Cut-off valves CODE 2006 IRC SECTION P2903.9 P2903.9.1 P2903.9.3 P2903.9.2 P2503 G2413&17 G2412.5 G2414 G2415 & G2417 2415.14.3 G2415.8 G2415.8.2 504.5

Testing and inspection Gas pipe sizing Gas pipe labeling Gas pipe materials Gas pipe system installation & Testing Gas tracer wire Protection of piping

2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC

Insulate hot water lines

2006 IECC

Plumbing Rough/Energy p. 2 of 2 2020

Gas Rough and Test Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Pipe materials Pipe sizes Pressure test (gas) Connections/joints Tracer wire for non-metallic piping CODE 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC 2006 IRC 2006 IFGC Carrollton Policy 2006 IRC 2006 IFGC G2414.8 404.8 SECTION G2414 403 G2413 402 G2417 404 G2414 Ch. 4 G2415.14.3 404.14.3 G2415.9 404.9 COG Amendment G2414.6.1 Ch. 4 G2416 405

Pipe depth

Gas risers Gas pipes not to be bent or strained Separate ditch for gas piping Protection from corrosion

Gas Rough and Test 3021

Pre Brick Inspection Checklist p. 1 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Sheathing will be free of all holes No framing shall be visible The roofing process has been completed Exterior openings exposed to weather shall be flashed Exterior veneer shall not be attached to wood frame construction at or point more than 30 in height When wall ties are installed: ties shall be spaced to support not more than 2.67 sq. ft. of wall; wall ties shall not be more than 24 on centers horizontally & vertically When anchored veneer is applied over 2x4 stud construction, stud spacing shall not exceed 16 When anchored veneer is applied over 2x6 stud construction, stud spacing shall not exceed 24 CODE 2006 IRC 2006 IRC Tech Policy 2006 IRC 2006 IRC SECTION R703 R703 6-21-99 R703 Table R703.7

2006 IRC

R703.7.4.1

Tech. policy Tech. policy

Sec. V 32-33c Sec. V 32-33c R703.7.5 R703.7.8 Sec v 32 Brick Supported by Wood 9-93 703.7.2 703.7.2.1 703.7.2.2 703.7.3 Sec v 32 Brick Supported by Wood 9-93

Flashing and counter flashing

2006 IRC Tech Policy

Veneer height and support limitations 30 max height to footing rafter size per 2006 IRC, then doubled

2006 IRC Tech Policy

Pre Brick p. 1 of 2 3042

Pre Brick Inspection Checklist p. 2 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM CODE SECTION R703 Sec V 32 Brick Supported by Wood 9-93 R703.4.1.2 Sec v 32 Brick Supported by Wood 9-93 R602.10 Table R602.3.(1) R703.2 402.4

Brick on wood rafters 3 2x8

2006 IRC Tech Policy

Wind sheer Scab 2x4 on side of each stud

2006 IRC Tech Policy

Wall bracing Water resistance barrier Exterior wall envelope Seal exterior wall envelope

2006 IRC

2006 IRC 2006 IECC

*NOTE: Lintel installation occurs after the pre-brick inspection and is the responsibility of the contractors. Lintel = the horizontal beam forming the upper member of a door or window frame supporting part of the structure above it.

Pre Brick p. 2 of 2 3042

Plumbing Top Out/HVAC Rough/Gas Test/Energy Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Plumbing vent termination with respect to openings Water heater vent location Gas pipe sizing and tests. CSST must be supported every 4ft. and a min. of 12" clearance from roof deck unless installed in a flexible metal sleeve must be bonded from manifold to breaker panel with min. # 6 wire or equivalent. Tested 10lbs. on 20 lb. 3 1/2" diaphragm test gauge and 3lbs. on a 6lb. 3 1/2 diaphragm test gauge on low side with current calibration sticker. Ventilation Protection of piping (freeze or damage) Fixture drainage lines Tests and inspection (sanitary drainage and potable water Required Hose bibs ( 2 on SFD front & rear) 1 on Town homes and Condo's Showers (material, installation and testing) Island fixture venting Vent connection and grades Stack venting Wet venting limitations Trap arm and p-trap Prohibited traps Clothes washer trap and tail piece height requirement CODE 2006 IRC 2006 IRC SECTION P3103 M1804

2006 IRC & COC Technical Policy

G2413&17

2006 IRC 2006 IRC 2006 IRC 2006 IRC COC Tech. Policy COG Amendment 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC

M1507 P2603.6 P3005 P2503

P2708 P3112 P3104 P3102 P3108 P3201.5 P3201.5 Table 3201.7 P2706.2

Plumbing Top Out/HVAC Rough/Gas Test/Energy p. 1 of 3 3065

Plumbing Top Out/HVAC Rough/Gas Test/Energy Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM CODE 2006 IRC & COC Technical Policy for CSST 2006 IRC & COC Technical Policy 2006 IECC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IECC 2006 IECC 2006 IECC 2006 IECC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC COG Amendment 2006 IRC SECTION

Piping support

P2605

Water heaters: Regulations and installation Insulate hot water lines Above ceiling pan and drain for water heater Combustion air Ducts (HVAC)

P2801.5.1 P2801.5 504.5 P2801 M1701 M1601.2 1601.3.4 C.O.G. Table. 503.3.3.3 503.2.8 C.O.G 504.5 C.O.G 503.2.7 M1305.1 M1411 M1602 M1507 M1502 504.6 Chapter 10 M1805

Duct insulation

Refrigerant piping insulation Hot water pipe insulation Plenums: Sealed & secure HVAC equipment: access and service space Condensation Return air Exhaust fans: vent termination Clothes dryer duct

Chimney & vents

Plumbing Top Out/HVAC Rough/Gas Test/Energy p. 2 of 3 3065

Plumbing Top Out/HVAC Rough/Gas Test/Energy Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM CODE Specific appliances (fireplace and fuel burning equipment) 2006 IRC SECTION

Specific appliances (fireplace and fuel burning equipment)

2006 IRC M1901

Water heaters

M2005

Plumbing Top Out/HVAC Rough/Gas Test/Energy p. 3 of 3 3065

Electrical Rough/Frame/Building/Energy Inspection Checklist Building Sheet p. 1 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM
Wall heights/stud heights Safety glazing

CODE
2006 IRC 2006 IRC

SECTION
R602.3.1 Carrollton Tbl R308.4 R602.10.3 R602.10.6 C.O.G. Amend. R802.5.1 NCTCOG Policy R502.8 R502.8.1 R502.8.2 602.6.1 R502.6 R303.3 R806.1 R806.2 R806.3 R802.3 R502.4 R602.7 R804.3 R313.1.1 R403.1.6 R320.1 R602.8

Wind bracing

2006 IRC

Struts and purlins Brick supported by wood members

2006 IRC 2006 IRC

Cutting, notching and boring

2006 IRC

Floor joist bearing Bathroom and laundry room ventilation Attic ventilation (This only for a reminder at this stage. Shall not cause inspection disapproval.)

2006 IRC 2006 IRC

2006 IRC

Rafter, joist, header construction

2006 IRC

New additions or remodel, smoke detector requirements/wiring Bottom plates anchor - bolts or shot Perimeter bottom plates treated Fire blocking - holes and openings in top plates

2006 IRC 2006 IRC 2006 IRC 2006 IRC

Electrical Rough/Frame/Building/Energy Building Sheet p. 1 of 2 3066

Electrical Rough/Frame/Building/Energy Inspection Checklist Building Sheet p. 2 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM
Draft stop Stairs: run, rise, width Fireplace lintel support

CODE
2006 IRC 2006 IRC 2006 IRC

SECTION
R502.12 R311.5 R1003.7 N1102.1 C.O.G. Amend. R802.1 R320.1.1 R802 R703 R802.9 R602.3.3 R310.1 Ord 1604 as amended R 602.10 R702.3.8

Windows / Skylights U-Factor, SHGC

2006 IECC

Proper lumber grade stamps Roof and ceiling framing Exterior wood protection/sheathing Framing at skylights Line up of floor and ceiling joists to studs Size & location of emergency bedroom windows Driveway not allowed to street if alley exists Nailing Patterns on exterior sheathing No green board allowed in bathroom shower/tub areas

2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC CZO 2006 IRC 2006 IRC

Electrical Rough/Frame/Building/Energy Building Sheet p. 2 of 2 3066

Electrical Rough/Frame/Building/Energy Inspection Checklist Electrical Sheet p. 1 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM
Required outlet spacing / location

CODE
2008 NEC

SECTION
210.52 210.63 210-52 210.70

Required outlets/switches circuits Kitchen counter top spacing

2008 NEC

Protection of wires run through framing/studs

2008 NEC

300.4 334 314.17 334 334.12

Support of NM cables (staples)

2008 NEC

NM cable in wet locations / kitchen islands (not allowed)

2008 NEC

Grouping / bundling of cables ( no more than 4- #12 & #14 )

2008 NEC

334.8

Damaged, pinched or torn cables

2008 NEC

110

Sealing penetrations top plates and fire blocking

2008 NEC

300.21

Recessed lighting fixtures clearances / energy

2008 NEC

410

2008 NEC Bonding of metal boxes / ground pigtails / grounding

250.148 314.4 404.9 314.27 R313

Ceiling fan rated boxes Smoke / fire alarm locations

2008 NEC IRC 2006

Electrical Rough/Frame/Building/Energy Electrical Sheet p. 1 of 2 3066

Electrical Rough/Frame/Building/Energy Inspection Checklist Electrical Sheet p. 2 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM
Attic space requirements: switches , service outlet , a/c disconnect & exhaust fan controls

CODE
2008 NEC

SECTION
210.70 210.63 320.23 680.71 Through 681.74 314.16 310.15 200.6 408.41

2008 NEC Jacuzzi tub requirements: circuits, gfci, & bonding

Conductor fill for boxes / number or cables in box Panel service conductor size Neutral identification (white tape) One neutral per termination point on bar/ buss Grounds may be doubled Sub- panel isolation / no bond at to neutral at sub-panel Coverage of panel during contruction

2008 NEC 2008 NEC 2008 NEC 2008 NEC C.O.C 2008 NEC

250.24

2008 NEC 2008 NEC

110.12 250.28 250.52 250.53 250.92 250.32 250.64 408.58 408.54

Bonding / grounding : all metal enclosures / cold water bonding

Concrete encased electrode /other electrodes / access Panel identification / marking phases /amps/ voltage Panel maximum 42 circuits

2008 NEC

2008 NEC 2008 NEC

Electrical Rough/Frame/Building/Energy Electrical Sheet p. 2 of 2 3066

Insulation Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM CODE SECTION 102 402 502 1102.1 R 703.2

Insulation walls, ceilings, floors 2006 C.O.G. Amendments Water resistance barrier on exterior wall envelope

2006 IECC 2006 IRC 2006 IRC

Insulation 3067

Roof Final Inspection


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM CODE 2006 IRC COG Amendment 2006 IRC 2006 IRC SECTION

Minimum class C roof

R902 Table R503.2.1(1) M1306.1

Minimum deck thickness 7/16 Clearance from combustibles

Note: Inspection shall be requested at the completion of the deck replacement process. The contractor is completely responsible for installing the roof in accordance with the manufacturers specifications. The final roof inspection is limited to materials and clearance from combustibles.

Roof Final 4003

Utility Release/Plumbing, HVAC/Energy Final Inspection Checklist p. 1 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Gas hooked up to appliances All plumbing fixtures in place, connected and water on No leaks in fixture drains Gas shut-off valves and connectors Water heater temperature and pressure relief valve Water heater clearance (if installed) Service water heating Furnace AFUE rating (seasonal) Valve box at house Vacuum breakers/frost proof hose bibbs Seal firebox where penetrated by gas log lighter A/C pad Catwalk and working space for attic units Appliance venting (if installed) *Vent-A-Hood not included Electrical safely capped (or fixture installed) A/C overcurrent protection to manufacturers specs Electric panel feeder size Grounding electrode system Jacuzzi motor No unused openings in panel 2006 IRC 2006 IRC 2006 IRC 2008 NEC 2008 NEC 2008 NEC 2008 NEC 2008 NEC 2008 NEC CODE 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IRC 2006 IECC 2006 IECC 2006 IRC 2006 IRC SECTION G2422 P2503 P2503.5.2 G2420 P2803 M2005 504 Tbl.503.2 P2903.9.1 P2903.8.7 P2903.10 Mfg Specs 1403.2 1305.1 M1801 410-5 440.22 310.15 250 680 & 681 110.12

Utility Release/Plumbing, HVAC/Energy Final p. 1 of 2 4005

Utility Release/Plumbing, HVAC/Energy Final Inspection Checklist p. 2 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM City clean out Water meter can Controls / Temperature Clearance from combustibles Termite certification Bollards behind driveways for subdivision screening walls CODE GDS GDS 2006 IECC 2006 IRC 2006 IRC GDS SECTION S11 W-7 503.3.2.2 M1306.1 R320 M-4

Utility Release/Plumbing, HVAC/Energy Final p. 2 of 2 4005

Pool Work Final Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM CODE 2006 IPC Carrollton Policy 2008 NEC 2008 NEC 2008 NEC 2006 IRC 2006 IPC Carrollton Policy SECTION 802.1.4 802.2.1 680 680 680 AG105.2 AG105.2.4 608

P-Trap GFCI for pool lights GFCI location & testing Grounding terminations Fence enclosure, gates and latches Backflow protection Backwash/drain pipe Any gas line related items Lo pressure 3 lbs on 6 lb visibly certifiable diaphragm gauge High or med. 60 lbs on 100 lb visibly certifiable diaphragm gauge Pool heaters ON-OFF switch Pool cover for heated pools Pool time clocks setting Drainage Entrapment protection / svrs system in place

2006 IRC 2006 IFGC

App. G

2006 IECC 2006 IECC 2006 IECC CDO 2006 IRC 2006 IRC

504.3.1 504.3.2 504.3.3 Ord. 1964 R401.3 Appendix G AG 106

Pool Work Final 4042

Electrical/Building/Energy Final Inspection Checklist Building Sheet p. 1 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Safety glass and glazing Attic access and appliance access Smoke detectors (with battery backup) Front and rear address (minimum 4 inch numbers) Hearth size Combustibles clearance from fireplace opening Separation between garage and house Percentage of exterior brick(SF@70%) Water meter cans (boxes) CODE 2006 IRC 2006 IRC 2006 IRC Policy 2006 IRC 2006 IRC 2006 IRC CZO 2007 GDS Subdv Ord GDS SECTION R308 R807.1 M1305 R313 Fire Dept. R1001.10 Tbl 1001.01 1001.11 1003.18 R309.2 Art. VII W-7 Art. X, Sec. G & X1sec B P-15, P-22 P-26 Water & Sewer Chapters

City walks and approaches

Sewer cleanouts, water valves, manholes; level and accessible Any work done without permit such as fences exceeding 20 feet in length, lawn sprinkler, dish, pool, etc. Attic ventilation *Includes Vent-A-Hood duct Exterior refrigerant piping Blown-in insulation shall comply with IECC

2007 GDS

General Brochure 2006 IRC 2006 IECC 2006 IECC 2006 IRC R806 402.4.1 102.11,1101.4 402.1.2

Electrical/Building/Energy Final Inspection Checklist Building Sheet p. 1 of 2 4063

Electrical/Building/Energy Final Inspection Checklist Building Sheet p. 2 of 2


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Surface drainage shall be directed to swales to ensure drainage away from foundation.
Stair and handrail requirements

CODE 2006 IRC


2006 IBC 2006 IRC

SECTION R401.3
1009.1& 1012.4 311.51

Electrical/Building/Energy Final Inspection Checklist Building Sheet p. 2 of 2 4063

Electrical/Building/Energy Final Inspection Checklist Electrical Sheet


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline CODE ITEM
Covers, face plates & canopies a. Outlet boxes b. Snap switches c. Receptacles d. Damp locations e. Fixtures f. Closet fixtures GFCI locations a. Bathroom b. Garage c. Outdoor d. Crawl space e. Unfinished basement f. Kitchen g. Bar sink Appliance installation Stair and handrail requirements Electrical panel Grounding electrode system

CODE

SECTION

2005 NEC

314.25 314.41

2005 NEC

210-8

2005 NEC 2006 IBC 2006 IRC

422 1009.1& 1012.4 311.51 250.50 250-52 310.16 440-11 440.12 440.22 320.23 110-26 408 220 310-16 310-16

2005 NEC

2005 NEC A/C disconnect, wire & fuse size

Protection of wiring in attics Electrical panel installation

2005 NEC 2005 NEC

Service conductor size Other electrical conductor sizes

2005 NEC 2005 NEC

Electrical/Building/Energy Final Inspection Checklist Electrical Sheet 4063

Clean and Show/Construction Heat/Electric Service Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Proper breaker size for heating unit Panel cover installed access to electrical equipment No holes in panel or unused openings Capping of all loose wires and installed outlet covers Identification of panel service on meter base or disconnect CODE 2008 NEC 2008 NEC 2008 NEC 2008 NEC 2008 NEC 2008 NEC SECTION 424 408 110 408 110-12 110.14 408 110 230

Clean and Show/Construction Heat/Electric Service 6015

Clean and Show/Construction Heat/Gas Service Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Pipe materials (gas) Pipe sizes (gas) Connections (gas) Pressure test (gas) Proper installation Venting of appliance CODE 2006 IFGC 2006 IFGC 2006 IFGC 2006 IFGC 2006 IFGC 2006 IFGC SECTION 403 402 403 406 305 Chapter 5

Clean & Show/Const. Heat/Gas Service 6020

Clean and Show/Construction Heat/Gas and Electric Service Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM Combine 6015 & 6020 inspections CODE SECTION

Clean and Show/Construction Heat/Gas and Electric Service 6060

General Check/Follow-up Inspection Checklist


This checklist is not to be construed as all-inclusive; it is only to be used as a guideline. CODE ITEM General Check/Follow-up CODE SECTION

General Check/Follow-up 7000