You are on page 1of 3

TM

SRT=STEEL ROUND TAPERED


20'39' Mounting Height

Catalog # Project Comments

Type

Date

Fixed Tenon or Drilled

Prepared by

SPECIFICATION FEATURES 1 ASTM Grade steel base plate with ASTM A366 base cover. 2 Hand hole assembly 3" x 5" on SRT poles. 3 Steel shaft minimum yield 55,000 PSI. Shot blasted and painted with premium TGIC polyester powder coat. 4 Drilled or Tenon (specify). 5 Anchor bolt per ASTM A576 with (2) nuts, (2) flat washer, and (1) lock washer. Nuts, washers and threaded portion of bolt are hot dip galvanized. 3" hook for 3/4" bolt. 4" hook for 1" bolt.
3
Mounting Height (MH)

POLE COMPATIBILITY MATRIX

DRILL PATTERN Single w/Arm [1] 0.69 1.09 0.71 1.11 1.27 1.6 1.28 1.82 0.85 1.35 1.03 1.64 1.15 2.1

EPA + MOUNTING CONFIGURATIONS 2 @ 180 [2] 1.38 2.18 1.42 2.22 2.54 3.20 2.56 3.64 1.70 2.70 2.06 3.28 2.30 4.20 2 @ 90 [5] 1.38 2.18 1.42 2.22 2.54 3.20 2.56 3.64 1.70 2.70 2.06 3.28 2.30 4.20 3 @ 90 [3] 1.84 2.86 1.90 2.92 3.60 4.50 3.63 4.96 2.35 3.83 2.89 4.70 3.20 6.00 3 @ 120 [6] 1.84 2.86 1.90 2.92 3.60 4.50 3.63 4.96 2.35 3.83 2.89 4.70 3.20 6.00 4 @ 90 [4] 2.07 3.20 2.14 3.27 4.13 5.55 4.17 5.62 2.68 4.56 3.49 5.77 3.81 7.50

PRODUCT ICON SMALL ICON MEDIUM ICON SMALL STRUCTURAL MOUNT ICON MEDIUM STRUCTURAL MOUNT VISION SMALL

TENON A C J K E M F G A C A C E M

2
Hand Hole 12 5/16"

VISION MEDIUM VISION SMALL STRUCTURAL MOUNT

1
B

VISION MEDIUM STRUCTURAL MOUNT ASCENT SMALL ASCENT MEDIUM STRUT SMALL STRUT MEDIUM

Base View S BC

X-FORM SMALL X-FORM MEDIUM See Drill Patterns on page 3.

D BP

5
AB

F O U R B O L T A N C H O R A G E [see ordering information] PB=Bolt Projection AB=Bolt Dimensions D=Bolt Diameter

H=Bolt Dimensions

www.cooperlighting.com

Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes.

AVU082205

S R T STEEL ROUND TAPERED

The following information illustrates the correct way to enter an order for SRT8A30SGMA2G. The ordering designation is detailed as follows.
Shaft 3 Size 8 Wall Thickness A Mounting Height (ft.) 30 Base Type S Fixture Mounting + Type A No. + Location of Arms 2 Accessories (Ground Lug) G

Steel S

Round R

Tapered T

Colors GM

Mtg. Height MH 20 25 30 35 35 39 39

Catalog 1, 2 Number SRT6A20SBZ SRT7A25SBZ SRT8A30SBZ SRT8A35SBZ SRT9D35SBZ SRT9A39SBZ SRT9D39SBZ

Wall Thickness .120 .120 .120 .120 .180 .120 .180

Base Square (In.) S 10 1/2 10 1/2 12 1/2 12 1/2 12 1/2 12 1/2 12 1/2

Bolt Circle Dia. (In.) BC 11.0 11.0 12.5 12.5 12.5 12.5 12.5

Bolt Proj. (In.) BP 4 1/2 4 1/2 5 5 5 5 5

Shaft Size (In.) B 6.3 x 3.5 7.0 x 3.5 7.7 x 3.5 8.4 x 3.5 8.4 x 3.5 8.9 x 3.5 8.9 x 3.5

Anchor Bolt Dia. + Length (In.) AB 3/4 x 25 x 3 3/4 x 25 x 3 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4

Net. Wt. (Lbs.) 173 214 290 342 482 341 536

EPA (Sq. Ft.) 4 At Pole Top 70 80 90 29.8 22.7 17.8 28.1 21.4 16.7 24.0 18.2 14.2 23.0 17.3 13.5 38.9 29.6 23.2 21.5 16.2 12.4 38.2 29.0 22.5

100 14.3 13.4 11.3 10.5 18.3 9.5 17.7

EPA (Sq. Ft.) 4 2' Above Pole Top 70 80 90 100 27.1 20.6 16.2 13.1 26.0 19.8 15.5 12.5 22.5 17.0 13.3 10.6 21.7 16.4 12.7 9.9 36.8 28.0 21.9 17.3 20.5 15.4 11.8 9.0 36.4 27.6 21.4 16.8

Max. Fixture LoadInclude Bracket (Lbs.) 400 400 400 400 400 400 400

NOTES: 1 Catalog number includes pole with anchor bolts with double nuts. (BEFORE INSTALLING ANCHOR BOLTS MAKE SURE PROPER ANCHOR BOLT TEMPLATE IS OBTAINED FROM COOPER LIGHTING). 2 Tenon size or machining for rectangular arms must be specified. Hand hole is located 180 from single arm. 3 Shaft size, base plate, anchor bolts and projections may vary slightlyall dimensions nominal. 4 EPAs based on shaft properties with wind normal to flat. EPAs calculated using base wind velocity as indicated plus 30% gust factor. 5 Two piece pole. Shipped in two sections and is easily joined together at the job site by slip-fitting together.

MOUNTING OPTIONS=FIXED Designation O.D. Number (in.) 1 2 3/8" 2 2 3/8" 3 3 1/2" 5 3"

TENON [add as suffix] Length O.D. (in.) 3 1/2" 4" 5" 4"

LENGTH

ACCESSORIES A=1/2" Tapped Hub 1 B=3/4" Tapped Hub 1 C=Convenience Outlet 2 G=Grounding Lug (Max. Wire #8 AWG) H=Additional Hand Hole and Cover (12" Below Pole Top90 from Hand Hole) NOTES: 1 Location is 3' above base 90 from hand hole. 2 Outlet is located 4' above base and on same side of pole as hand hole, unless specified otherwise. Receptacle not included, provision only.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com


Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 AVU082205

S R T STEEL ROUND TAPERED

DRILL PATTERNS (TYPE A)

(TYPE C)

(TYPE J)
.312'' [8 mm] dia. hole

(TYPE K)
.312'' [8 mm] dia. hole 2 3/4" [70 mm] 16 3/8" [416 mm] 3/4'' [20 mm] dia. holes 3" [77 mm] 1 1/2" [39 mm] (2) 9/16'' [15 mm] dia. holes

2 1/8" [54 mm] 3/4'' [20 mm] dia. hole 2 1/2'' [64 mm] 1 1/4'' [32 mm] (2) 3/8'' [10 mm] dia. holes

2 1/8" [54 mm] 3/4'' [20 mm] dia. hole 3'' [77 mm] 1 1/2'' [39 mm] (2) 9/16'' [15 mm] dia. holes

2 3/4" [70 mm] 12 23/32" [322 mm] 3/4'' [20 mm] dia. holes 2 1/2" [64 mm] 1 1/4" [32 mm] (2) 3/8'' [10 mm] dia. holes

(TYPE E)

(TYPE M)

(TYPE F)
.312'' [8 mm] dia. hole

(TYPE G)
.312'' [8 mm] dia. hole 2 3/4" [70 mm] 15 7/8" [405 mm] 3/4'' [20 mm] dia. holes 4 7/8" [124 mm] 2 7/16" [62 mm] (2) 9/16'' [15 mm] dia. holes

2 13/16'' [71 mm] 3/4'' [20 mm] dia. hole 7/8'' [23 mm] 3 7/8'' [99 mm] (2) 3/8" [10 mm] dia. holes

2 5/16'' [59 mm] 3/4'' [20 mm] dia. hole 2 7/16'' [124 mm] 4 7/8'' [124 mm] (2) 5/8'' [16 mm] dia. holes

2 3/4" [70 mm] 11" [280 mm] 3/4'' [20 mm] dia. holes 3 7/8" [99 mm] 3" [77 mm] (2) 3/8'' [10 mm] dia. holes

FIXTURE DRILLING OPTIONS [Note handhole position relative to drill locations]

Single

2 @180

3 @ 90

4 @ 90

2 @ 90

3 @ 120

2 @ 120

CAUTION: Cooper Lighting poles have been designed to support only the luminaires and equipment originally intended. Miscellaneous items such as pennants, signs, and decorations may cause pole failure because of overloading. Addition of these items voids The Cooper Lighting warranty. Cooper Lighting will, however, supply information regarding total loading capacity on request. Cooper Lighting poles are guaranteed only when used in a pole/luminaire or floodlight combination. Any other application of poles, including application without a luminaire or floodlight, voids Cooper Lightings warranty.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com


Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 AVU082205

You might also like