LCP-10G3A4EDRx-G 10GBASE-SR SFP+ Optical Transceiver

FEATURES
RoHS compliant Compliant to SFP+ Electrical MSA SFF-8431 Compliant with SFF-8472 MSA Standard LC duplex fiber-optic connector I C for integrated Digital Optical Monitoring Power consumption 1W
2

Description
The LCP-10G3A4EDRx-G is a hot pluggable 10Gbps small form factor plus transceiver module integrated with the high performance 850nm VCSEL transmitter, high sensitivity PIN receiver and limiting amplifier for 10Gbps applications. It is compliant with the SFF-8431 SFP+ Electrical Multi-source Agreement (MSA) with five digital monitoring functions:

Applications
10G LAN switch 10G Ethernet switch/router 10G Fiber channel SAN applications

Temperature, Vcc, Tx optical power, Tx laser bias current and Rx received optical power.

1
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Absolute Maximum Ratings
Parameter Storage Temperature Supply Voltage Range @3.3V Symbol TS VCC3 Min. -40 -0.5 Typ. Max. 85 3.6 Unit C V

Recommended Operating Conditions


Parameter Case Operating Temperature LCP-10G3A4EDR-G LCP-10G3A4EDRH-G Supply Voltage @3.3V DC Common Mode Voltage Symbol TC VCC3 VCM Min. -5 -10 3.135 0 Typ. Max. +70 +85 3.465 3.6 Unit C V V

3.30

Low Speed Electrical Characteristics


(VCC=3.135V to 3.465V) Parameter Total Supply Current Power Consumption TX_Fault, RX_LOS TX_Disable RS0, RS1
1. 2.

Symbol ICC VOL VOH VIL VIH VIL VIH

Min.

Typ.

0 Host_Vcc-0.5 -0.3 2.0 -0.3 2.0

Max. 300 1 0.4 Host_Vcc+0.3 0.8 VccT+0.3 0.8 VccT+0.3

Unit mA W V V V V V V

Note

1 1 2 2

Shall be pulled up with 4.7k-10k ohms to VccT in the module. Shall be pulled low to VeeT with a 30k ohms resistor in the module.

2
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Optical Transmitter Characteristics
Parameter Data Rate Signaling speed variation from nominal. Average Output Power Wavelength Spectral Width RMS Transmitter OFF Output Power Extinction Ratio Optical Modulation Amplitude Relative Intensity Noise Optical Return Loss Transmitter eye mask definition {X1, X2, X3, Y1, Y2, Y3} Symbol R Min. Typ. 10.3125 Max. 100 Pavg Poff ER OMA RIN ORL -5 840 860 0.45 -30 Unit Gb/s ppm dBm nm nm dBm dBm dB/Hz dB 1 Note

3 Compliant with Minimum OMA relation table -128 12

{0.25, 0.40, 0.45, 0.25, 0.28, 0.40} Transmitter eye mask definition

3
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G

Optical Receiver Characteristics


Parameter Symbol Min. Typ. Max. Unit Note Signaling speed (nominal) TS 10.3125 Gb/s Signaling speed variation from 100 ppm nominal. Center Wavelength 840 860 nm Overload PO 0 dBm Receiver sensitivity in OMA RSO -11.1 dBm 2 LOS De-assert LOSD -11 dBm LOS Assert LOSA -27 dBm 3 LOS Hysteresis LOSD-LOSA 0.5 dB Receiver Reflectance -12 dB 4 Differential Output Amplitude 150 850 mV Stressed Receive sensitivity OMA -7.5 dBm Notes: 1. Max output optical power is lesser than Class 1 safety limits (CDRH and EN 60825) -12 2. Measured by reference TX with 4.75dB extinction ratio at 10 BER 3. When LOS asserted, the data output is Low-Level (fixed) 4. When the terminal is viewed from the optical path, the reflection toward the optical path of the optical signal with a central wavelength of 840nm to 860nm transmitted to terminal. 5. Distance, shown in the Link Length table, are calculated for worst case fiber and transceiver characteristics based on the optical and electrical specifications shown in this document using techniques utilized in IEEE 802.3. In the nominal case, longer distance are achievable.

4
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Link Length
Fiber type 62.5 um MMF 50 um MMF Minimum modal bandwidth @ 850nm (MHz*km) 160 200 400 500 2000 Operating range (meters) 2 to 26 2 to 33 2 to 66 2 to 82 2 to 300 Note 5 5 5 5 5

SFP+ Transceiver Electrical Pad Layout

5
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Module Electrical Pin Definition
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CML-I CML-I CML-O CML-O LVTTL-I LVTTL-O LVTTL-I LVTTL-O LVTTL-I LVTTL-I/O LVTTL-I/O Logic Symbol VeeT TX_Fault TX_Disable SDA SCL MOD_ABS RS0 RX_LOS RS1 VeeR VeeR RDRD+ VeeR VccR VccT VeeT TD+ TDVeeT Name/Description Module Transmitter Ground Module Transmitter Fault Transmitter Disable; Turns off transmitter laser output 2- write Serial Interface Data Line 2- write Serial Interface Clock Module Absent, connected to VeeT or VeeR in the module Not Implement Receiver Loss of Signal Indication Not Implement Module Receiver Ground Module Receiver Ground Receiver Inverted Data Output Receiver Non-Inverter Data Output Module Receiver Ground Module Receiver 3.3V Supply Module Transmitter 3.3V Supply Module Transmitter Ground Transmitter Non-Inverted Data Input Transmitter Inverted Data Input Module Transmitter Griund 1 1 1 1 1 2 4 Note 1 2 3

Note: 1. The module signal ground pins, VeeR and VeeT, shall be isolated from the module case. 2. This pin is an open collector/drain output pin and shall be pulled up with 4.7k-10k ohms to Host_Vcc on the host board. Pull ups can be connected to multiple power supplies, however the host board design shall ensure that no module pin has voltage exceeding module VccT/R + 0.5V. 3. This pin is an open collector/drain input pin and shall be pulled up with 4.7k-10k ohms to VccT in the Module. 4. This pin shall be pulled up with 4.7k-10k ohms to Host_Vcc on the host board.

6
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Low speed electrical control pins and 2-wire interface
In addition to the 2-wire serial interface, the SFP+ module has the following low speed pins for control and status: TX_Fault TX_Disable RS0/RS1 MOD_ABS RX_LOS

1 TX_Fault TX_Fault is a module output pin that when High, indicates that the module transmitter has detected a fault condition related to laser operation or safety. The TX_Fault output pin is an open drain/collector and must be pulled p to the Host_Vcc with 4.7k-10k ohms on the host board 2 TX_Disable TX_Disable is a module input pin. When TX_Disable is asserted High or Left open, the SFP+ module transmitter output must be turned off. The TX_DIS pin must be pulled up to VccT in the SFP+ module.. 3 RS0/RS1 RS0 and RS1 are module input rate select pins and are pulled low to VeeT with a > 30k resistor in the module. RS0 is an input hardware pin which optionally selects the optical receive data path rate coverage for an SFP+ module. RS1 is an input hardware pin which optionally selects the optical transmit path data rate coverage for an SFP+ module. RS1 is commonly connected to VeeT or VeeR in the legacy SFP modules. The host needs to ensure that it will not be damaged if this pin is connected to VeeT or VeeR in the module. 4 MOD_ABS Mod_ABS is pulled up to Host_Vcc with 4.7k-10k ohms on the host board and connected to VeeT or VeeR in the SFP+ module. MOD_ABS is then asserted High when the SFP+ module is physically absent from a host slot. In the SFP MSA (INF8074i) this pin had the same function but is called MOD_DEF0. 5 SCL/SDA SCL is the 2-wire interface clock and SDA is the 2-wire interface data line. SCL and SDA are pulled up to a voltage in the range of 3.14V to 3.46V on the host. 6 RX_LOS RX_LOS when High indicated an optical signal level below that specified in the relevant standard. The RX_LOS pin is an open drain/collector output and must be pulled up to host Vcc with a 4.7k-10k ohms on the host board. RX_LOS assert min and de-assert max are defined in the relevant standard. To avoid spurious transition of RX_LOS a minimum hysteresis of 0.5 dB is recommended.

7
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Recommend Circuit Schematic

8
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Package Outline Drawing for Metal Housing with Bail de-latch

Latch Color Identifier Black

SEE COLOR CODE

SEE COLOR CODE NOTES: 1.UNIT:mm 2.COLOR CODE: SINGLE MODE IS BLUE MULTI MODE IS BLACK

9
DELTA ELECTRONICS, INC.

Complies with 21 CFR 1040.10 and 1040.11 Made in x FS

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Timing parameters for SFP+ management
Parameter Symbol TX_DISABLE Assert time t_off TX_DISABLE Negate time t_on Time to initialize 2-wire t_2w_start_up interfase Time to initialize t_start_up Time to initialize cooled t_start_up_cooled module Time to Power Up to Level 2 t_power_level2 Time to Power Down from T_power_down Level 2 TX_Fault assert TX_Fault_on TX_Fault assert for cooled TX_Fault_on module TX_Fault Reset t_reset RS0, RS1 rate select timing t_RS0_FC, for FC RS1_FC RS0, RS1 rate select timing t_RS0, t_RS1 non FC RX_LOS assert delay t_los_on RX_LOS negate delay t_los_off Notes:
1) 2) 3) 4)

Min.

Max. 100 2 300 300 90 300 300 1 50

Unit sec msec msec msec sec msec msec msec msec sec

Note 1 2 3 4 4 5 6 7 7 8 9 9 10 11

10 500 10 100 100

sec msec sec sec

Rising edge of TX_Disable to fall of output signal below 10% of nominal. Falling edge of TX_Disable to rise of output signal above 90% of nominal. This only applies in normal operation, not during start up or fault recovery. From power on or negation of TX_Disable. From power on or TX_Disable negated during power up, or TX_Fault recovery, until non-cooled power level 1 part (or non-cooled power level 2 part already enabled at power level 2 for TX_Fault recovery) is fully operational.

5) From falling edge of stop bit enabling power level 2 until non-cooled module is fully operational. 6) From falling edge of stop bit disabling power level 2 until module is within power level 1 requirements. 7) From Occurrence of fault to assertion of TX_Fault. 8) Time TX_Disable must be held High to reset TX_Fault. 9) From assertion till stable output. 10) From Occurrence of loss of signal to assertion of LOS 11) From Occurrence of presence of signal to negation of RX_LOS.

10
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Enhanced Digital Diagnostic Interface
The memory map in the following describes an extension to the memory map defined in SFP MSA. The enhanced interface uses the two wire serial bus address 1010001X (A2h) to provide diagnostic information about the modules present operating conditions.

2 wire address 1010000 X (A0h) 0 0

2 wire address 1010001 X (A2h)

Alarm and Warning Thresholds (56 bytes) Serial ID Defined by SFP MSA (96 bytes) 55 56 Cal Constants (40 bytes) 95 96 95 96 Real Time Diagnostic Interface (24 bytes) Vender Specific (32 bytes) 119 120 Vender Specific 127 128 127 128 User Writable EEPROM (120 bytes) Reserved in SFP MSA (128 bytes) 255 247 248 255 Vender Specific (8 bytes)

Digital Diagnostic Memory Map Specific Data Field Descriptions

11
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
EEPROM Serial ID Memory Contents (2-Wire Address A0h)
Address 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Hex 03 04 07 10 00 00 00 00 00 00 00 03 67 00 00 00 08 03 00 1E 44 45 4C 54 41 20 20 20 20 20 20 20 20 20 20 20 00 00 00 00 4C 43 50 ASCII Address 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 Hex 2D 31 30 47 33 41 34 45 44 52 20 20 20 41 20 20 20 03 52 00 CS1 00 1A 00 00 SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN DC DC ASCII 1 0 G 3 A 4 E D R Note 1 Address 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 Hex DC DC DC DC DC DC 68 F0 03 CS2 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ASCII

Note 5

D E L T A

Note 2

Note 3

L C P

Note 4

Note 6

Notes: 1) 2) 3) 4) 5) 6) Byte 53: Base on part number. Please reference ordering information. Byte 63: Check sum of bytes 0-62. Byte 68-83: Serial number. Byte 84-91: Date code. Byte 95: Check sum of bytes 64-94. Byte 128 to 255 had been set hex 00.

12
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G
Digital Diagnostic Monitoring Interface
Alarm and Warning Thresholds (2-Wire Address A2h)
Address 00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-45 56-91 92-94 95 96-97 98-99 100-101 102-103 104-105 106-109 110 111 112-119 Note: # Bytes 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 16 36 3 1 2 2 2 2 2 4 1 1 8 Name Temp High Alarm Temp Low Alarm Temp High Warning Temp Low Warning Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reversed External Calibration Constants Reversed Checksum Real Time Temperature Real Time Supply Voltage Real Time Tx Bias Current Real Time Tx Optical Power Real Time Rx Received Power Reserved Optional Status/ Control Bits Reserved Optional Set of Alarm and Warning Value (Dec.) Tc(Max.)+8 Tc(Min.)-8 Tc(Max.)+3 Tc(Min.)-3 3.8V 2.8V 3.5V 3.1V Iop+10 mA Iop-5 mA Iop+7 mA Iop-3 mA 1.5 -7 0.5 -6 2 -13.1 1 -12.1 Unit Note 1

Volt

mA

dBm

dBm

1) TC: Case Operating temperature 2) IOP: Operating current at room temperature. The min. setting current is 0 mA.

13
DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G

State/ Control Bits


Byte 110 110 110 110 110 110 110 110 Bit 7 6 5 4 3 2 1 0 Name Tx Disable State Soft Tx Disable Reserved Rate Select State Soft Rate Select Tx Fault LOS Data_Ready_Bar Description Digital state of the Tx disable input pin Read/ Write bit that allow software disable of laser Rate Select State Software Rate Select State Digital state of the Tx fault output pin Digital state of the LOS output pin. NA

Optional Set of Alarm and Warning


Byte 112 112 112 112 112 112 112 112 113 113 113 116 116 116 116 116 116 116 116 117 117 117 Bit 7 6 5 4 3 2 1 0 7 6 5-0 7 6 5 4 3 2 1 0 7 6 5-0 Name Temp High Alarm Temp Low Alarm Vcc High Alarm Vcc Low Alarm Tx Bias High Alarm Tx Bias Low Alarm Tx Power High Alarm Tx Power Low Alarm Rx Power High Alarm Rx Power Low Alarm Reserved Temp High Warning Temp Low Warning Vcc High Warning Vcc Low Warning Tx Bias High Warning Tx Bias Low Warning Tx Power High Warning Tx Power Low Warning Rx Power High Warning Rx Power Low Warning Reserved Description Set when internal temperature exceeds high alarm level Set when internal temperature is below low alarm level Set when internal supply voltage exceeds high alarm level Set when internal supply voltage is below low alarm level Set when Tx Bias current exceeds high alarm level Set when Tx Bias current is below low alarm level Set when Tx output power exceeds high alarm level Set when Tx output power is below low alarm level Set when received power exceeds high alarm level Set when received power is below low alarm level Set when internal temperature exceeds high warning level Set when internal temperature is below low warning level Set when internal supply voltage exceeds high warning level Set when internal supply voltage is below low warning level Set when Tx Bias current exceeds high warning level Set when Tx Bias current is below low warning level Set when Tx output power exceeds high warning level Set when Tx output power is below low warning level Set when received power exceeds high warning level Set when received power is below low warning level

Digital Diagnostic Monitor Accuracy Parameter


Transceiver Temperature Power Supply Voltage TX Bias Current TX Optical Power RX Optical Power Notes: 1) Temperature is measured internal to the transceiver

Typical Value
3C 3% 10% 3dB 3dB

Note
1 2

2) Voltage is measured internal to the transceiver 14


DELTA ELECTRONICS, INC.

Revision: S0 2011/9/21

www.deltaww.com

LCP-10G3A4EDRx-G

Regulatory Compliance
Feature Electromagnetic Interference (EMI) Reference FCC Part15 Class B

Electrostatic Discharge (ESD)

IEC/EN 61000-4-2 MIL-STD-883E EIA-JESD22-A115-A IEC 60825-1:2001 EN 60825 IEC/EN 60950-1 UL60950

Laser Eye Safety

Component Recognition

Ordering Information for SFP modules


LCP-10G3A4EDRX1-G X1: Temperature Blank: -5 to +70 degree C H: -10 to +85 degree C