You are on page 1of 2

W A T L O W

Power Controllers
SERIES CZR
The SERIES CZR solid state contactor
provides a low-cost, highly compact
and versatile solid state option for
controlling electric heat. With din-rail
and back panel mounting standard on
every controller, the CZR allows for
simple and quick installation.
The extensive capabilities of the
SERIES CZR include single-phase,
18 to 50 amp zero-cross and random
switching up to 600VÅ(ac) (see
output rating curve). The unique
integrated design removes the
guesswork associated with selecting
a proper heat sink and precise
terminations for the application.
SERIES CZR contactors are available
in Vı(ac/dc) input contactor versions. Back-to-back SCR design Output Voltage
All configurations are model number • Rugged design • 24 volt; 24VÅ(ac) min. to
dependent and factory selectable. Specifications 280VÅ(ac) max.
The SERIES CZR is reliably backed Control Mode • 480 volt; 48VÅ(ac) min. to
by a two-year warranty from Watlow 530VÅ(ac) max.
• Zero-cross or random fired
Winona. • 600 volt; 48VÅ(ac) min. to
contactor output
Performance Capabilities 660VÅ(ac) max. (not available on
Operator Interface
• Output 18 to 50 amps 18 amp version)
• Command signal input
• Output voltage up to 660VÅ(ac) • Off state leakage
• Input signal indication LED 1mA at 25°C (77°F) max. for
Features and Benefits
Input Command Signal 600VÅ(ac) models; 10mA at 25°C
DIN-rail or standard panel mount (77°F) max. for 24 through
• Input Type DC1
• Versatile, quick and low-cost 480VÅ(ac) models
• Turn on voltage 4VÎ(dc) max.,
installation • Holding current: 250mA max.
turn off voltage 1VÎ(dc) min.
Compact size Output Amperage
• Input current: dc typically 10mA
• Reduces panel space; less cost @ 4VÎ(dc),13mA @ 32VÎ(dc) • See output rating curve. Ratings

Power Controllers
Touch-safe terminals • Input Type AC1 are into a resistive heater load
• Increase safety for installer and • 90 to 140Vrms, must turn on at Output Amperage Rating SERIES CZR
operator 90VÅ(ac), must turn off at Model 18 24 34
Mercury-free 10VÅ(ac) Maximum Surge Current 625 250 625
• Input current: 15mA typical 16.6 mSec
• Environmentally safe
@120VÅ(ac) Maximum I2t for fusing 1,620 260 1,620
Faster switching with solid state
• Saves energy and extends • Input Type AC2 Model 42 50
heater life • 18 to 36VÅ(ac) input, must turn Maximum Surge Current 1,000 1,000
Agency Approvals on at 18VÅ(ac), must turn off at 16.6 mSec
10VÅ(ac) Maximum I2t for fusing 4,150 6,000
• UL® recognized, CSA certified,
VDE and CE • Input current: 10mA typical @
24VÅ(ac)
• Applications requiring agency
approval

173
Power Controllers F.O.B.: Winona, Minnesota

SERIES CZR Mounting Weight/Dimensions


Options include DIN-rail or standard • 260 g (9.2 oz)
Specifications Cont. back panel mounting. • 24 to 50 amp models: 100 mm
Agency Approvals • The DIN-rail specification: (3.95 in.) high x 45 mm (1.75 in.)
DIN EN 50022, 35 mm x 7.5 mm wide x 109 mm (4.3 in.) deep
• Class II construction
(1.37 in. x 0.30 in.) • 18 amp models: 100 mm (3.95 in.)
• UL® 508 recognition, File #E73741
• Minimum clipping distance: high x 22.6 mm (0.89 in.) wide x
and CSA File LR 700195
34.8 mm (1.37 in.) 99 mm (3.9 in.) deep
• 73/23/EEC CE Low Voltage
• Maximum clipping distance:
Directive
35.3 mm (1.39 in.)
• VDE 0805, registration number
• Mount cooling fins vertical
126921
• License number 136037 for
18 amp models Output Rating Curves
• License number 130515 for Maximum Ambient Temperature °F Maximum Ambient Temperature °F
24 to 50 amp models 50 68 86 104 122 140 158 176 50 68 86 104 122 140 158 176
Output Terminals 60 90
Current (Amps)

Current (Amps)
50 75
• Compression type 34 A 50 A
40 60
• For 18 amp models: 30
24 A
45
• Maximum wire size 3.0 mm 20
18 A 42 A
30
(10 AWG), torque to 0.6 Nm
10 15
(5.3 in. lbs)
0 0
• For 24 to 50 amp models: 10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80
• Maximum wire size 16.0 mm Maximum Ambient Temperature °C Maximum Ambient Temperature °C
(6 AWG stranded) torque to
1.5-1.7 Nm (13-15 in. lbs) Ordering Information
Operating Environment To order, complete the code number to the right with the information below:
• Up to 80°C (176°F). See output
rating curves for your application. C___-A__V-___0
Control Mode
• 0 to 90 percent RH, non-
R = Random
condensing
Z = Zero-cross
• Insulation only tested to 3,000 Output Amperage
meters 18 = 18 amp (not available with 600V output)
• Units are suitable for “pollution 24 = 24 amp
degree 2” 34 = 34 amp
42 = 42 amp
• Cycle time should be less than
50 = 50 amp
three seconds
Output Voltage
24 = 24 to 280VÅ(ac)
48 = 48 to 530VÅ(ac)
60 = 60 to 660VÅ(ac) (not available with 18A model)
Input Type (Contactor)
DC1 = 4 to 32VÎ(dc)
AC1 = 90 to 140VÅ(ac)
AC2 = 18 to 36VÅ(ac)

Note: Do not use the AC1 and AC2 input type models with temperature control outputs that
include an AC snubber filter. This could cause the CZR to stay full on.