A More Realistic Characterization Of Power MOSFET

Output Capacitance Coss

Introduction: manufacturer’s data sheets are at 25V


Vds which is not really useful in actual
The Power MOSFET has gained circuit application.
popularity and become the dominant
switching device in power electronics In an effort to better aid circuit
since 1975. Its fast switching speed has designers, International Rectifier has
extended power conversion switching taken the extra steps to specify the
frequencies from the 20kHz range of effective Coss (Coss at Vds of 1V and
bipolar transistor to beyond 100kHz. in 80% Vdss) and also extend the
hard switching. With soft switching capacitance curves to 80% of Vdss ,
techniques such as zero voltage instead of 50V, for IRs new range of
switching (ZVS) and zero current high voltage HEXFETs. An example of
switching (ZCS), the switching these curves for a new 600V HEXFET is
frequency can exceed Mega Hertz. shown in Fig. 1 below :

As switching frequency moves upward, 100000


V GS = 0V, f = 1MHz
power MOSFET parasitic parameters C iss = Cgs + Cgd , Cds SHORTED
such as inductance and capacitance C rss = C gd
10000 C oss = Cds + C gd
should be well defined and understood in
C, Capacitance (pF)

order to optimize the particular power


conversion design. This design tip Ciss
1000

focuses on explaining the power


Coss
MOSFET output capacitance Coss and
100
how it actually affects the power
conversion circuit. Other capacitance’s
such as input capacitance Ciss, and 10 Crss
reverse transfer capacitance Crss, and the
related gate charges have been well 1 A
explained in previous International 1 10 100 1000
VDS , Drain-to-Source Voltage (V)
Rectifier publications.

In hard switching circuits, Coss is used


to calculate the additional power Fig. 1:. Typical Capacitance Vs. Drain to Source
dissipation of power MOSFET due to Voltage
discharging this output capacitor every
switching cycle. In soft switching Listed below are the definitions of Coss
circuits, Coss may be used to calculate effective and Coss @ 80% of Vdss, how
the resonant frequency or transition time, they are measured and how to apply
which is critical in establishing ZVS and them in circuit design calculations.
/ or ZCS conditions. Unfortunately the
value of Coss varies non-linearly as a Coss effective:
function of drain to source voltage Vds. Coss effective is defined as a fixed
The value of Coss specified in most capacitance that would give the same
charging time as the output capacitance
of a MOSFET while Vds is rising from Drive Circuit
Q1
100

zero to 80% Vdss at Vgs = 0V. Figure 2 For The

shows the test circuit and the associated Totem Pole +


waveforms used to measure the Coss Pair (Q1, Q2) 100K Vdd
effective of this 600V HEXFET. The Q2 DUT
10
totem pole driver HEXFET is driven on /
off by a short single pulse, at the end of
this pulse, Vds of the device under test
(DUT) starts rising, Coss is being
charged by the 100kΩ to Vdd of 600V.
The time it takes for Vds to rise from
zero to 480V, which is 80% of rated
Vdss, tc is measured. Coss effective is
then calculated per following equations:

Vc = 600 V( 1- e-t/RC ) = 480V

Where t is the measured tc, R = 100kΩ,


and C is Coss effective. Solving for Coss
effective:
Fig. 2. Circuit For Measuring Coss Effective
Coss effective = 6.21* tc pF and The Associated Waveforms
( tc is in µS )
Coss at 80% Vdss:
The 80% Vdss value is chosen as a
This capacitance value is the Coss
convenient measuring point. It is this
measured at Vds = 80% Vdss. Figure 3
Coss effective that should be used in any
shows the standard Coss test circuit.
resonant type of calculation that involves
Coss, not the value specified in the
Fig. 3. Test Circuit For Coss (CB is
standard data sheet, which is a single
value at 25V Vds. The Coss at 25V may 620K

be two to three times larger than the


Ck
Coss effective, depending on the silicon Low

cell design and density of the particular + DC BIAS DUT 2000 pF


CB
MOSFET. The classical LC resonant
equation fr = ½ π ( LrCr)1/2 is used in High
620K
many modern power converter circuits,
where the MOSFET Coss effective may Capacitance Bridge)
be whole or part of the resonant Coss (DUT) = Cm * Ck) / Ck - Cm
capacitance. With the defined Coss
effective, circuit designers can more Each time the MOSFET turns on, the
accurately determine some other circuit energy stored in the output capacitance
parameters such as transformer, inductor will be dissipated in the device, with
and other stray capacitance’s to enable Coss at the Vds voltage prior to turning
design optimization. on this energy equal to E = ½ Coss Vds2.
As the switching frequency goes up the
power dissipation ( Pd = E x fs ) in the Coss doubles. The loss due to Coss is
MOSFET due to discharging this energy 77.4% that of conduction loss ( I2 rms x
increases proportionately, which may Rds on ) and 16% of the total losses for
become a limiting factor in hard the type 5 FET at 200kHz.
switching topologies. Figure 4 shows the
loss distribution for various types of Summary:
power MOSFETs in a typical 200W off
line single transistor forward converter Coss at 80% of Vdss and Coss effective
operating at 100kHz. to 80% of Vdss specified are of different
FET Type1 FET Type2 FET Type 3 FET Type 4 FET Type 5 FET Type 6
values, and have different implications.
Pcond
Psw
3.65
3.15
2.54
3.12
2.63
2.95
2.63
2.91
1.86
2.80
3.93
3.32
Coss is used only for the purpose of
Pcoss
Ptotal
0.48
7.28
0.53
6.19
0.53
6.11
0.52
6.06
0.72
5.38
0.6
7.85 calculating its loss’ contribution as this
loss can’t be instrumentally measured.
FET Power Dissipation In A Typical 100 KHz. Offline Hard Coss effective is used solely for
8 Switching RCD Reset Forward Converter At 200W, 100C

7
calculating any resonant circuit that
involves the output capacitance of the
Power Dissipation ( Watt )

5 Pcond
Psw
MOSFET. For all practical purpose,
4

3
Pcoss
Ptotal
these specified values are sufficed to use
2 for operating Vds voltages in the range
1
of 70% to 90% of Vdss with about 10%
0
FET Type1 FET Type2 FET Type( Power
Devices 3 FET Type 4)
MOSFET FET Type 5 FET Type 6 or less error. If more accuracy is
required, the associated test circuits
above can be used to measure to the
Fig. 4: FET Loss Distribution Comparison @ 100kHz.
exact operating voltage .
Figure 5 shows the same loss
distribution as in Figure 4 but at
200kHz. operating frequency. Conclusion:

Pcond
FET Type1 FET Type2 FET Type 3 FET Type 4 FET Type 5 FET Type 6
3.65 2.54 2.63 2.63 1.86 3.93
Historically the energy loss due output
Psw
Pcoss
6.3
0.96
6.24
1.06
5.9
1.06
5.82
1.04
5.60
1.44
6.64
1.2
capacitance in a MOSFET has been
Ptotal 10.91 9.84 9.59 9.49 8.90 11.77
deemed to be insignificant. With the
general increase in application operating
FET Power Dissipation In A Typical 200KHz. Offline Hard
Switching RCD Reset Forward Converter At 200W, 100C frequency and proliferation of differing
12
topologies this design tip demonstrates
Power Dissipation (Watts)

10

8
Pcond how important this capacitance can be
Psw
6 Pcoss and shown a meaningful way of
Ptotal
4
calculating its contribution to the
2

0
switching energy loss.
FET FET FET FET FET FET
Type1 Type2 Type 3 Type 4 Type 5 Type 6
Devices ( Power MOSFET)

Fig. 5: FET Loss Distribution Comparison @ 200kHz.

From Figure 4 and 5, one can observe


that as the switching frequency doubles
the conduction loss remains the same,
but the switching loss and loss due to