You are on page 1of 7

DPP B5

Kolej Kemahiran Tinggi MARA Pasir Mas, Kelantan.


JOB SHEET
PROGRAMME : SESSION : CODE/COURSE : DTEI JULY DEC 2011 DFT 4322 ELECTRONIC SOFTWARE APPLICATION 3 Hours MS. NORSYURIATIE ABD AZIZ 1. MANAGING THE DATABASE At the end of the lesson, students should be able to: 1. Add and remove component families from User or Corporate Library database 2. Set up or modify user field titles for any database 3. Add or change toolbar button symbols for component families in User. 1. Computer 2. Printer 3. Electronic Workbench Software - Multisim 10.0 SEMESTER : 4 SHEET NO : WEEK : VENUE : JS 3 05 M17

NO OF STUDENTS : 4A DURATION : LECTURER : TOPIC : SUB-TOPIC :

LEARNING OUTCOME :

TOOLS / EQUIPMENTS / MATERIALS :

DATA :

Page 1 of 7

DPP B5

INSTRUCTION :

This experiment is to approach the student by doing the practical base on the theory that has been learned before. By adapting the theory the student should be able to do the experiment and implementation such as on safety, cleanliness, tidiness and etc.

PROCEDURE STEP KEY POINT


Safety : Make sure the wearing is suitable for the work. Avoid wear the metal materials. Avoid playing while doing work.

1. Open Multisim
2.

a. Open Multisim Circuit Window as usual a. Set your Grid and Title Block. a. Click the Component Editing button on the Design Bar and choose Database Manager from the pop up menu that appears. Or Choose Tools/Database Manager. The Database Manager screen appears as figure 1.

Setting up your circuit window and Setting up your Title Block. To invoke the Management screen. Database

3.

Figure 1

4. To add a component family to the User or Corporate Library database

a. In the Database list, choose the database in which you want to work (Select the User) b. Click Add. You prompted to select a family group: Select Family Group : TTL Enter Family Name : 74LS

ii.

Page 2 of 7

DPP B5

PROCEDURE STEP KEY POINT


c. Click OK. You return to the Database Manager screen. d. A default icon of the group is automatically assigned to the new family as in figure 2

5. To load a component toolbar button

Figure 2 a. With the desired component family selected, click Load. You will be prompted to navigate to the desired toolbar button file as in figure 3.

Figure 3 b. Selected the desired toolbar button file (AND_DSW) and click Open. c. The new toolbar button will be displayed on the Database Manager screen in the button Toolbar area as in figure 4.

6. To edit the component toolbar button

default

Figure 4 a. With the desire component family selected, click Edit b. Your paint program is launched and the bitmap file of the button opened. c. Edit the bitmap file to your requirement and then save and close the paint program.

Page 3 of 7

DPP B5

PROCEDURE STEP KEY POINT


d. The revised toolbar button will appear as the component toolbar button.

7. To delete a component family from the User Database.

a. In the Database list, choose the database from which you want to delete a component family b. In the family list, choose the component family that you want to delete. c. Click Delete. You are prompted to confirm your deletion. d. To complete the delete process, click OK. You return to the Database Manager screen

8. To delete empty families from the User Database.


a. Click Delete Empty families. You are prompted to confirm your command to delete empty family folders. b. To proceed click OK. All empty family folders will be deleted from the family list on Database Manager screen for the selected database

9.

Copying Components

a. Click the component editing button on the design bar and choose Copy Component from the pop-up menu that appears.
OR Choose Tool/Data Manager The Data Manager screen appears. b. Using the drop-down list, identify the component you want to copy and click Copy you are prompted to select a destination. c. Select the component database and component family that you want to copy the component to and click OK. A confirmation screen appears, assuring you that the component has been copied. i. Database Name : Multisim Master ii. Family Name : 74LS iii. Component Name : 74LS00D

Page 4 of 7

DPP B5

PROCEDURE STEP KEY POINT


d. Click OK to return to the Copy component screen. e. When you are component, click Exit. finished copying

10. To component

check

the

copied
a. From component Database) b. Click TTL c. Choose 74LS00 Section A d. Drag and paste the NAND gate on the schematic page/circuit window. toolbar (User

Page 5 of 7

DPP B5

RESULT :

QUESTION/DISCUSSION : 1. By using steps and key points number 4 to 10 please create a component family under User Database for resistor, transistor and capacitor and attach into your lab report. 2. state it In Multisim 10.0 Components are stored in three different database please

3. Give the differences between Multisim Master Database and User Database? 4. .
Wrap up your results from observations, data, and calculations and tie them to the objectives of the lab. Did it work? Why? What do your results mean? Did you prove your hypothesis or something different? Back up your explanations with scientific theories or information you have learned in class or found by research. Cite any sources of information that you use for research. If the lab didnt work for some reason, explain what went wrong. (Not more than 200 words)

Why we cant modify the component under Multisim Master Database?

ANSWER : ... ... ... ... ... ...

Page 6 of 7

DPP B5 ... ...

REFERENCE : 1. 2. 3. 4. 5. Mastering CAD/CAM with Engineering Subscription Ibrahim Zeid Mc Grawhill Applied Numerical Methods with MATLAB for engineering Steven Chopra Mc Grawhill I-Deas Student Guide EDS Mc Grawhill Mechanical Engineering Design Richard Budy Mc Grawhill Autodesk Inventor CP James Leake Mc Grawhill

Checked by : Signature : Name : Designation : Date :

Page 7 of 7

You might also like