You are on page 1of 7

1.

NIM Server (URPMGNNIM01) Installation and Configuration


Following are the steps used to configure the NIM server. Since the NIM server has to be at the latest leve of AIX available at any given time, AIX v5.3 ML5 will be installed on the NIM server.

1.1. Data Repository creation


This section is to create a new directory structure that provides the necessary structure to support the NIM environment. As the root user issue the following commands: 1. 2. 3. 4. 5. 6. mklv t jfs2 y lvaix53 rootvg 8G mklv t jfs2 y lvbackups rootvg 20G crfs v jfs2 d lvaix53 m /export/aix53 A yes crfs v jfs2 d lvbackups m /export/backups A yes mount a check that the following file systems are mounted and available: a. /export/aix53 b. /export/backups 7. create the additional two directories: a. mkdir /export/aix53/mksysb

1.2. Configure the NIM Master


This outlines the steps required to configure the NIM Master. To configure the NIM Master, do the following (This may take 30mins): 1. Ensure that the AIX v5.3 CD 1 of 8 (or DVD) is inserted into the CD-ROM drive 2. nim_master_setup a device=/dev/cd0 a file_system=/export/aix53 volume_group=NIM_VG1 B 3. After the command has completed, verify that the following are created: a. /export/nim b. /export/aix53/5300-03bid_ow c. /export/aix53/resolv.conf d. /export/aix53/spot/530spot_res/image.data e. /export/aix53/spot/530spot_res/bosinst.data f. /export/aix53/spot/530spot_res/lpp_name g. /export/aix53/spot/530spot_res/usr h. /export/aix53/lpp_source/530lpp_res/RPMS i. /export/aix53/lpp_source/530lpp_res/usr/swlag j. /export/aix53/lpp_source/530lpp_res/installp/ppc

1.3. Create the AIX v?.? lpp_source and SPOT


If the NIM master was to support other versions of AIX like AIX v5.1/5.2, follow the steps in this section to create the AIX v5.2 lpp_source and SPOT resources (This may take 30mins). To create the resources, do the following: 1. 2. 3. 4. 5. 6. 7. mklv t jfs2 y lvaix52 rootvg 8G crfs v jfs2 d lvaix52 m /export/aix52 A yes mount /export/aix52 check /export/aix52 is mounted and available mkdir /export/aix53/mksysb Ensure that the AIX v5.2 CD 1 of 7 (or DVD) is inserted smitty nim_mkres_inst and update the following fields: a. Input device for installation images b. LPP_SOURCE Name c. LPP_SOURCE Directory d. Create new filesystem for LPP_SOURCE? e. SPOT Name f. SPOT Directory g. Create new filesystem for SPOT?

into the CD-ROM drive cd0 520lpp_res /export/aix52/lpp_source no 520spot_res /export/aix52/spot no

h. Leave the rest as is, a bosinst_data resource for 5.2 could be created but the one for 5.3 is identical 8. Once the operation has completed, proceed with the verification from step 3 in section 1.2

1.4. Update the lpp_sources for 5.2 and 5.3


This step involves adding (copying) the filesets from the remaining AIX CDs into the lpp_source directory. This step can be skipped if an AIX DVD was used. 1. 2. 3. 4. 5. 6. 7. Insert AIX v5.3 CD 2 of 8 into the CD-ROM drive smitty bffcreate /dev/cd0 as the input device /export/aix53/lpp_source/530lpp_res as the DIRECTORY for storing software package Repeat for all the install CDs Add the AIX fixes to the directory the same way Once done remember to update the toc file: a. cd /export/aix53/lpp_source/530lpp_res/installp/ppc b. inutoc .

1.5. Install AIX Fixes/Device Drivers/Maintenance Levels


Always remember to update the O/S. In this case, the lpp_source and spot need to be at AIX v5.3 ML4 CSP. As well, if additional device drivers like SDD (Subsystem Device Drivers) need to be installed on the client systems, they need to be in the lpp_source/SPOT. Here are the steps: 1. Go to the SDD website and download all the required/additional device drivers/scripts needed: http://www-03.ibm.com/servers/storage/support/software/sdd/downloading.html 2. Make sure to save them in the appropriate lpp_source directory (for example: /export/aix53/lpp_source/530lpp_res/installp/ppc) 3. Also download latest level of the device driver (also available from the same website) 4. On saved: a. Cd to the lpp_source: cd /export/aix53/lpp_source/530lpp_res/installp/ppc b. Run inutoc .

1.6. Update the spot


Once the lpp_source has been built, the SPOT (Shared Product Object Tree) must be updated. To update the SPOT, do the following: 1. 2. 3. 4. smitty nim_update_all select the target SPOT select the appropriate lpp_source check to make sure the SPOT and lpp_source are correct and press enter

1.7. Create the mksysb resources


Once the SPOT has been updated, mksysb resources must be created for each version of AIX. Usually, the mksysb image is a base AIX image taken from a standard AIX Server. The mksysbs contain all the required filesets and any common customizations. Customization would include AIX fixes, paging space changes, vmm, mirroring, network options, etc Below are some common examples: 1. The /etc/security/limits file was edited. In the default stanza, the fsize = 2097151 line was changed to fsize = -1 2. The /etc/profile file was edited. The set o vi line at the end of the file 3. The SDD and Host Attachment Scripts filesets were installed 4. The /etc/hosts could be edited 5. The /etc/netsvc.conf file could be edited For the ALDO Environment, the NIM Master will also be used for migrating servers from old systems to new LPARs hence the mksysb resources will be actual server mksysbs. The mksysbs were created using the mksysb i /mnt/mksysb_name command. Where /mnt was nfs mounted from

URPMGNNIM01:/export/backups. Once the mksysbs are created on URPMGNNIM01, proceed with the following steps: 1. cp /export/backups/mksysb5300_03 /export/aix53/mksysb/. 2. smitty nim_mkres, select mksysb from the list and update the following fields: a. Resource Name mksysb530003 b. Server of Resource master c. Location of Resource /export/aix53/mksysb/mksysb5300_03 d. Comments AIX v5.3 ML3 base mksysb 3. Repeat for all mksysbs

1.8. Edit the /export/aix53/5300-03bid_ow File


The default bosinst.data file that NIM created must be edited to support your requirements. In order to accomplish this, do the following: 1. a. b. c. d. Edit the /export/aix53/5300-03bid_ow file and set the following lines to yes: Make sure RECOVER_DEVICES = no ENABLE_64BIT_KERNEL = no CREATE_JFS2_FS = yes HDISKNAME = hdisk0 A bosinst_install resource can also be created for each bid_ow file: 1. smitty nim_mkres, select bosinst.data from the list and update the following fields: a. Resource Name bid_ow.32bit b. Server of Resource master c. Location of Resource /export/aix53/bid_ow.32bit d. Comments 32bit Bosinst data file 2. Repeat for all bosinst data files

1.9. Verify the NIM Configuration


This step involves running the lsnim command and verifying that the all the resources weve created so far are there. The output should look as follows: # lsnim master machines master boot resources boot nim_script resources nim_script master_net networks ent master_net1 resources resolv_conf 5300-03bid_ow resources bosinst_data 530lpp_res resources lpp_source mksysb530003 resources mksysb mksysb520007 resources mksysb 530spot_res resources spot 520lpp_res resources lpp_source 520spot_res resources spot For a more detailed output, run the lsnim l command.

2. NIM Client install


There are two stages to configuring and installing a new client partition from the NIM master. The first step involves adding the client to the NIM master. The second step involves configuring the client partition for a NIM action, and then initiating a NIM boot of the partition over the network.

2.1. Adding the Client to the NIM Master


This is a 2 step process. First, the /etc/hosts file on the NIM Master is edited to add the clients network information (unless DNS is used) and second, the client is configured on the master. Since the /etc/hosts file has already been edited with the appropriate information, let us proceed with the addition of the client to the NIM Master. Following are the steps needed to accomplish this task: 1. smitty nim_mkmac 2. enter the hostname (RSDRTKDB1-UAT) and press enter 3. update only the following fields: a. Kernel to use for Network Boot DO NOT change to [up] for LPARs with 1 CPU b. Network Speed Setting auto c. Network Duplex Setting auto d. Network Adapter Logical Device Name ent0 e. Comments Used it to specify the AIX version of the LPAR 4. Press enter when done 5. lsnim l client_name to check that the client was created properly. Check that the Cstate field is set to ready for a NIM operation. If it is in any state other than this one, repeat the above procedures fixing any errors # lsnim -l RSDRTKDB1-UAT RSDRTKDB1-UAT: class = machines type = standalone comments = AIX v5.3 connect = shell platform = chrp netboot_kernel = mp if1 = master_net1 RSDRTKDB1-UAT 0 ent0 net_settings1 = auto auto cable_type1 = tp Cstate = ready for a NIM operation prev_state = ready for a NIM operation Mstate = not running 6. Repeat for all systems

2.2. Preparing the Client for Installation on the NIM Master


To start, the newly created NIM client must have a bosinst.data resource allocated to it in order to make it serviceable. To allocate the bosinst.data, run the following command: 1. smitty nim_bosinst 2. Select the appropriate client partition (RSDRTKDB1-UAT) 3. Select mksysb for the installation type 4. Select the appropriate mksysb (mksysb_DB1 will be used for RSDRTKDB1-UAT) 5. Select the appropriate SPOT resource (520spot_res) 6. Update the following fields: a. LPP_SOURCE 520lpp_res b. BOSINST_DATA to use during installation 5300-03bid_ow c. RESOLV_CONF to use for network configuration master_net1 d. ACCEPT new license agreements? yes e. Initiate reboot and installation now? no f. In installp flags => ACCEPT new license agreements? yes 7. press enter twice

8. A warning message may appear due to the fact the mksysb and SPOT are not at the same level. It is normal and will not affect the completion of the operation This may happen in the future when the mksysbs taken on the partitions that may have been upgraded with patches while the spot wasnt. 9. Verify that the client was properly configured with lsnim l client_name. Check that the Cstate field is set to BOS installation has been enabled. If it is in any state other than this one, repeat the above procedures fixing any errors # lsnim -l RSDRTKDB1-UAT RSDRTKDB1-UAT: class = machines type = standalone comments = AIX v5.2 connect = shell platform = chrp netboot_kernel = mp if1 = master_net RSDRTKDB1-UAT 0 ent0 net_settings1 = auto auto cable_type1 = tp Cstate = BOS installation has been enabled prev_state = ready for a NIM operation Mstate = not running boot = boot bosinst_data = 5300-03bid_ow lpp_source = 520lpp_res mksysb = mksysb_DB1 nim_script = nim_script resolv_conf = master_net1 spot = 520spot_res control = master 10. Verify with ls l /tftpboot and notice new entries for RSDRTKDB1-UAT 11. Verify with showmount e and note the addition to the export list of RSDRTKDB1-UAT At this point, the first stage is complete and the NIM client partition has now been successfully configured on the NIM master.

2.3. Configuring and Installing the Client


Now that the client is configured on the NIM master and ready for installation via the network, the client must now be configured to install from the network. Following are the steps needed to configure the client. All steps can be done on the HMC or remotely using WebSM.

1. Activate the partition into SMS. a. Select the profile (Normal) and click on Advanced

b. Click on Boot mode and change it to SMS

c. d. e. f.

Click OK Click on the Open a terminal window or console session button Click on OK A terminal window appears and within seconds, it will display the SMS menu

2. Select 2. Setup Remote IPL (Initial Program Load) 3. Select the first ethernet adapter 4. Select 1. IP Parameters 5. Select 1. Client IP Address and enter the client address 6. Press enter 7. Repeat for the Server, Gateway and Subnet Mask 8. Pres on the ESC key to get to the previous menu 9. Select 2. Adapter Configuration 10. Select 1. Speed,Duplex and then select 1. auto,auto (rj45) 11. Press the ESC key to go back and select 2. 12. Select 2. No Protocol Spanning Tree Enabled

13. Press on the ESC key to go back and select 3. 14. Select 1. Standard

15. Press the ESC key to go back twice to get to 16. Select 3. Ping Test to perform a ping test

17. Confirm all the information and press 1. If anything needs to be change, go back and perform the necessary changes 18. If the ping is successful, proceed, if not, check the network settings again or contact the network administrator 19. Press the enter key and then the m key to go back to the main menu 20. Select 5. 21. Select 1. 22. Select 7. Select Boot Options Select Install/Boot Device List all Devices

23. Select 1. Ethernet ( loc=U7879.001.DQDGTZZ-P1-T6 ) which should be the adapter that was configured previously 24. Select 2. 25. Select 1. Normal Mode Boot Yes

26. Not that anything can be done at this point but check to see if the packets are being received on the client 27. And eventually the client will install 28. Once the client is installed, log into it to verify the configuration.