You are on page 1of 2

Page 1 LAB #4 INSPECTION OF A PART USING A STATIONARY UNIT AND FLUORESENT PARTICIALS Name: Josh McEachern Date: Feb

02, 2012 Customer: Sait NDT Foundations Job#: MPI Wet Method Stationary Unit Central Conductor Part Description: Flange Serial #: M1193 Other Numbers and Identifying Marks: 2-150 SA105 536 B16.5 Norma India Dimensions: Thickness 16mm, Diameter 151mm Conductor Rod Used: Diameter 38mm Black Light Calibration Reading and type: 1920mw per cm2 Specroline Black light Black Light Intensity Meter Information: Serial#1520448 Spectroline DM-365xA Long Wave (365nm) Ultra Violet Meter. Black Light Intensity Meter Calibration: Mar 10, 2006-Mar 10, 2007 White Light Intensity Check Reading and Info: 1 Lux Reading on 1999-2000 Switch Setting, Serial#Q311411 CALCULATIONS OF AMPERAGE FOR EACH SHOT SHOT#:1 TYPE OF SHOT: Central Conductor Diameter: 38mm Wall Thickness: 16mm Amperage: 1050

Page 2 INSPECTION TECHNIQUE Shot# 1 Tap Setting# 5 Type of Shot Central Conductor Field Direction Circular Amperage 1270 Remarks Actual starting amps used pie gauge no indications need more amps use bath poured on part. Used pie gauge no indications need more amps used bath poured on part. Used pie gauge and good magnetism is present used bath poured on part. Used bath poured on part no indications found. Used bath poured on part defect indications found. Rotated part 180 Degrees used bath poured on part Defect indications found. Used bath poured on part finial defects were found.

Central Conductor

Circular

1730

Central Conductor

Circular

2250

Central Conductor

Circular

2240

Central Conductor

Circular

2300

Central Conductor

Circular

2250

Central Conductor

Circular

2290

You might also like