You are on page 1of 140

Personas 77

Automated Teller Machine Site Preparation

B006-6208-H000 January 2012

NOTICE This is a contractual document. It contains important warning and confers important legal rights and obligations. You are advised to read it carefully. It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with all specifications and requirements of NCR and all applicable national, state, or local codes, regulations and laws. The product described in this book is a licensed product of NCR Corporation. APTRA is a trademark of the NCR Corporation. Microsoft, Windows NT and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current. To maintain the quality of our publications, we need your comments on the accuracy, clarity, organization, and value of this book. Address correspondence to: NCR Financial Solutions Group Ltd. Information Solutions Discovery Centre 3 Fulton Road Dundee, Scotland DD2 4SW 2002, 2003, 2004, 2005, 2006, 2012 By NCR Corporation Duluth, Georgia, U.S.A. All Rights Reserved

Federal Communications Commission (FCC) Radio Frequency Interference Statement


Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le prsent appareil numrique nmet pas de bruits radiolectriques dpassant les limites applicables aux appareils numriques de la classe A prescrites dans le Rglement sur le brouillage radiolectrique dict par le ministre des Communications du Canada.

Canadian Class A Device Declaration

NCR Personas 77 ATM Site Preparation

iii

Information to User

This equipment must be installed and used in strict accordance with the manufacturers instructions. However, there is no guarantee that interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately. NCR Corporation is not responsible for any radio or television interference caused by unauthorised modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may void the users authority to operate the equipment. The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the responsibility of the user.

Caution

iv

NCR Personas 77 ATM Site Preparation

Revision Record

Date

Page

Description of Change

Jul 01 Nov 01 May 02

All All viii 2-3 2-5 2-6/7 2-8/9 2-12 2-13 2-15/16 3-1 3-4 3-10 3-11 4-2 5-2

New Publication Updated to reflect increase in height of terminal Explanation of terminal variants UL291 security requirements Product ID label updated Terminal dimensions updated Floor areas updated UL291 security requirements. Floor loading updated Height to facia items updated Power requirements updated Comms cable routing updated Alarm Interface Cable (F/A Stretch) - Preparation RS232 cable information EMC statement Card accept decal dimensions EMI statements updated Comms Cables - Preparation Part Number changed New features - German Standard Security & CEN safes and advert lights. ADA information updated. Barcode reader labels. Updated (B006-6208-B000) to include 2.2 release features

Jun 02

3-3 3-4/5 3-6/8 Chap 2

Mar 03

Chap 5 July 03 All

NCR Personas 77 ATM Site Preparation

Date

Page

Description of Change

Oct 03 Nov 04

All

Updated (B006-6208-C000) to include certified Rear Access release features

2-14, 2-15, Updated (B006-6208-D000) Changes to dimensions. 2-16, 2-17, Addition of weatherisation. 2-37, 2-39. 2-33 3-1 Various Chap. 2 Updated (B006-6208-E000). Correction to dimension. Updated (B006-6208-F000). Add Power Consumption. Revision G: Add CEN L security enclosure. Revsion F: Added Contactless card reader to Height and Depth to Main Facia Items.

Jan 05 June 05 Mar 06 Jan 12

vi

NCR Personas 77 ATM Site Preparation

About This Document Preface

Preface
This book contains the information necessary for the preparation of a site conforming to NCR specifications. It is very important that the site complies with the requirements specified in this document because, once the equipment has been installed, deficiencies in site preparation or the problems caused by these deficiencies are much more difficult to detect and correct. Further, failure to comply with these requirements or to take proper steps to protect equipment against risks identified in this document may cause serious damage to the equipment and to the customers business. In addition to the need to comply with the requirements specified, electrical wiring and mechanical systems must also comply with all relevant codes, laws and regulations. It is important that the site be prepared by a customer or his agent who is fully conversant with the special requirements of electronic equipment. The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer. For information and guidance only, a list is provided, in general terms, of those matters for which the customer is responsible. This list is not intended to be comprehensive, and in no way modifies, alters, or limits the responsibility of the customer for all aspects of adequate site preparation. NCR staff will be available to answer questions relating to the contents of this document but, except where

the customer has been notified that a full or partial consultancy service is available and/or that NCR will be willing to undertake a preliminary or final site survey and the customer shall have entered into a formal contract with NCR for provision of the same

NCR Personas 77 ATM Site Preparation

vii

About This Document Preface

no comment, suggestion or advice offered or not offered about preparation of the site nor any inspection of the site whether before or after preparation is to be taken as approval of the location of the site and equipment or of its preparation and NCR will not be liable in respect of any comment, suggestion or advice given by its staff or in respect of any failure to give advice.

Finally, only the customer can know the full extent of damage which may be caused to his business by reason of failure of the equipment which is to be installed. For this reason, it is the customers responsibility to ascertain the extent of any such possible damage to his existing or planned business, and to effect full insurance in respect of it. The ATM variants, referred to throughout this publication, are as follows:

ATM Variants

Front Access Short (F/A Short) - with a Security Enclosure height of 878 mm (34.6 in.). Front Access Stretch (F/A Stretch) - with a Security Enclosure height of 943 mm (37.1 in.) Rear Access (R/A) and Vestibule - with a Security Enclosure height of 980 mm (38.6 in.).

Unless otherwise stated, the information given throughout this publication, applies to all variants of terminal. The ATM must be bolted to the floor to meet security and safety requirements.

Security Requirements

viii

NCR Personas 77 ATM Site Preparation

About This Document Safety Information

Safety Information
Barcode Reader
The Barcode Reader Module uses a Class 1 laser emitter that may be uncovered in the scanner engine is interfered with in any way. Refer to the Safety Compliance section in Chapter 15.16 of the NCR 56XX/Personas Automated Teller Machines Field Service Information Service Aids Mini Manual (BFM0-0547).

NCR Personas 77 ATM Site Preparation

ix

About This Document Safety Information

NCR Personas 77 ATM Site Preparation

Table of Contents

Contents

About This Document Preface....................................................................................................... vii ATM Variants......................................................................................viii Security Requirements.........................................................................viii Safety Information...................................................................................... ix Barcode Reader ..................................................................................... ix

Chapter 1 Planning Check List .................................................................................1-1 Installation Accessories............................................................................1-2

Chapter 2 Overview ..................................................................................................2-1 Customer Responsibilities........................................................................2-2 Product Identification...............................................................................2-3 Packaging Dimensions .............................................................................2-4 Front Access Short, Business Hours, German Standard, and CEN ...................................................................................................2-4 Front Access Stretch and Rear Access ................................................2-5 Vestibule..............................................................................................2-6 Advert Light Package ..........................................................................2-7 ATM Dimensions.....................................................................................2-8 Security Enclosure Variants ................................................................2-8 Front Access Terminals.......................................................................2-9 Rear Access, Lobby...........................................................................2-12 Vestibule Terminals...........................................................................2-14 Installation and Service Clearances........................................................2-20 Front Access - Service Footprints .....................................................2-21

NCR Personas 77 ATM Site Preparation

xi

Table of Contents

Rear Access - Service Footprints ...................................................... 2-29 Vestibule Terminal - Service Footprints........................................... 2-35 Securing Bolt Location Points, Lobby Terminals............................. 2-41 Securing Bolt Location Points, Vestibule Terminals........................ 2-49 Hole in the Wall Dimensions - Vestibule Terminal.......................... 2-53 Requirements for the Floor .................................................................... 2-54 Security Bolts.................................................................................... 2-54 Floor Covering .................................................................................. 2-55 ATM Location................................................................................... 2-55 Ambient Lighting .............................................................................. 2-55 Weight and Floor Loading ................................................................ 2-56 Access for All ........................................................................................ 2-58 Front Access Short, Business Hours, German, CEN 3 and CEN 4 Security ............................................................................... 2-58 Front Access Stretch, Rear Access and Vestibule ............................ 2-58 Heights to Main Facia Items ............................................................. 2-58 Recommended Wheelchair Clearance .............................................. 2-61 Internal Space Constraint for Fitting a Third Party Video Camera ................................................................................................. 2-62

Chapter 3 Power Quality Distribution and Grounding Requirements...................... 3-1 AC Requirements ................................................................................ 3-1 Input Voltage Setting .......................................................................... 3-1 Power Consumption............................................................................ 3-1 Power Cable ........................................................................................ 3-1 Grounding Requirements .................................................................... 3-3 Transient Power Loss.......................................................................... 3-3 EMI Susceptibility .............................................................................. 3-3 EMI Emission ..................................................................................... 3-3 Communications Requirements ............................................................... 3-4 Communication Cables - Routing....................................................... 3-4 High Order Communications Cables .................................................. 3-4 Alarm Interface Cable ......................................................................... 3-7 RS232 Cable ..................................................................................... 3-12 Remote Relay Cable.......................................................................... 3-13

xii

NCR Personas 77 ATM Site Preparation

Table of Contents

Chapter 4 Environmental Requirements...................................................................4-1 Temperature and Humidity..................................................................4-1 All Environments.................................................................................4-2 Electromagnetic Compatibility (EMC) ...............................................4-2 Barometric Pressure.............................................................................4-3 Heat Dissipation ..................................................................................4-3 Air Flow...............................................................................................4-3 Temperature Rise.................................................................................4-3 Acoustical Noise..................................................................................4-3 Weatherisation.....................................................................................4-3

Chapter 5 Decal Specifications.................................................................................5-1 Card Accept .........................................................................................5-2 Card Orientation Decal........................................................................5-3 Bar Code Reader Positioning Label ....................................................5-4 Advert Light Decal ..............................................................................5-5 Exit/Entry Slot Decals .........................................................................5-5

Appendix A AC Power Line Transient Protection ...................................................... A-1 Data Line Transient Protection ............................................................... A-3

Appendix B NCR Power Protection and Cabling Products......................................... B-1 AC Power Line Transient Protection ................................................. B-1 Data Line Transient Protection........................................................... B-2 Uninterruptible Power Supplies ......................................................... B-2 Contact Information............................................................................ B-4

NCR Personas 77 ATM Site Preparation

xiii

Table of Contents

xiv

NCR Personas 77 ATM Site Preparation

Table of Contents Planning Check List and Installation Accessories

Chapter 1

Planning Check List and Installation Accessories


Planning Check List 1-1

Installation Accessories

1-2

NCR Personas 77 ATM Site Preparation

Table of Contents Planning Check List and Installation Accessories

NCR Personas 77 ATM Site Preparation

Planning Check List and Installation Accessories

Planning Check List

Planning Check List


To assist in preparing your site for the arrival of the ATM, it is recommended that the various procedures, detailed in the following check list be carried out prior to the arrival of the ATM. The procedures given are listed in chronological order, starting with the procedure that should be carried out first.
Activity

Select site and make scaled floor plan Ensure correct environmental conditions Establish all contractor and vendor related schedules including surrounds/kiosk vendors Check communication line requirements Plan application development Check floor plan and make any alterations Install additional electrical outlets (if required) Prepare site for data communication Arrange for designing and printing of overlays/decals Order information products Order media supplies Plan operator training (optional) Ensure data communications equipment is installed and tested Ensure installation accessories listed are available

NCR Personas 77 ATM Site Preparation

1-1

Planning Check List and Installation Accessories Installation Accessories

Installation Accessories
When installing the ATM, it is recommended that the following items are available: Pincers/claw hammer to remove staples/nails from around the air/sea pallet 19 mm (3/4 in.) for UL safe, ring/open-ended combination spanner and socket to remove pallet bolts, and to fit floor bolts Cross-head screwdriver 13 mm (17/32 in.) spanner or socket - to remove the four screws that secure either of the cross struts to the pallet 10 mm (13/32 in.) ring/open ended combination spanner - for attaching earth stud 17 mm (11/16 in.) ring/open-ended combination spanner or socket Wooden/metal safety blocks to support the ATM during installation 4 mm (7/64 in.) Allen key Hex nut driver set (including M3 and M4 sizes) Selection of screwdrivers for flat blade and cross head applications Forklift or a lifting/moving device Packing to protect exterior of the ATM while on trolleys Lifting Trolleys (may need to be modified, refer to the Personas 77 ATM Installation Manual (B006-6209) Scissors.

1-2

NCR Personas 77 ATM Site Preparation

Table of Contents Physical Requirements

Chapter 2

Physical Requirements
Overview 2-1

Customer Responsibilities

2-2

Product Identification

2-3

Packaging Dimensions Front Access Short, Business Hours, German Standard, and CEN Front Access Stretch and Rear Access Vestibule Advert Light Package

2-4 2-4 2-5 2-6 2-7

ATM Dimensions 2-8 Security Enclosure Variants 2-8 Business Hours Security 2-8 UL 291 (Level 1) Standard Security 2-8 CEN Security 2-8 Front Access Terminals 2-9 Short, Standard, Business Hours and German Standard Security with Advert Light 2-9 Stretch, Standard Security 2-10 CEN 3, CEN 4 and CEN L with Advert Light 2-11 Rear Access, Lobby 2-12 Rear Access, Standard and German Standard Security 2-12 Rear Access, CEN 3 and CEN L Security 2-13 Vestibule Terminals 2-14 Vestibule, Standard and German Standard Security 2-14 Vestibule CEN 3 Security 2-16

NCR Personas 77 ATM Site Preparation

Table of Contents Physical Requirements

Vestibule CEN L

2-18

Installation and Service Clearances 2-20 Front Access - Service Footprints 2-21 Front Access Short and Business Hours Security, Minimum Service Footprint 2-21 Front Access Short and Business Hours Security, Recommended Service Footprint 2-22 Front Access Stretch and German Standard Security, Minimum Service Footprint 2-23 Front Access CEN 3 and CEN 4 Security, Minimum Service Footprint 2-25 Front Access CEN 3 and CEN 4 Security, Recommended Service Footprint 2-26 Front Access CEN L Security, Minimum Service Footprint 2-27 Front Access CEN L Security, Recommended Service Footprint 2-28 Rear Access - Service Footprints 2-29 Rear Access, Standard and German Standard Security, Minimum Service Footprint 2-29 Rear Access, Standard and German Standard Security, Recommended Service Footprint 2-30 Rear Access, CEN 3 Security, Minimum Service Footprint 2-31 Rear Access, CEN 3 Security, Recommended Service Footprint 2-32 Rear Access CEN L Security, Minimum Service Footprint 2-33 Rear Access, CEN L Security, Recommended Service Footprint 2-34 Vestibule Terminal - Service Footprints 2-35 Vestibule, Standard and German Standard Security, Minimum Service Footprint 2-35 Vestibule, Standard and German Standard Security, Recommended Service Footprint 2-36 Vestibule, CEN 3 Security, Minimum Service Footprint 2-37 Vestibule, CEN L Security, Minimum Service Footprint 2-39 Vestibule, CEN L Security, Recommended Service Footprint 2-40

NCR Personas 77 ATM Site Preparation

Table of Contents Physical Requirements

Securing Bolt Location Points, Lobby Terminals Lobby - Short Standard, German Standard, CEN 3 and CEN 4 Security, Front Access Lobby - Business Hours Security, Front Access Lobby - Stretch Standard Security, Front Access Lobby - CEN L Security, Front Access Lobby, Standard Security, Rear Access Lobby, CEN L Security, Rear Access Securing Bolt Location Points, Vestibule Terminals Vestibule, Standard Security Variant, Rear Access Vestibule, CEN L Security, Rear Access Hole in the Wall Dimensions - Vestibule Terminal

2-41 2-41 2-42 2-43 2-44 2-45 2-48 2-49 2-49 2-52 2-53

Requirements for the Floor Security Bolts Floor Covering ATM Location Ambient Lighting Weight and Floor Loading Front Access Stretch with Standard Security Front Access Short with CEN 3 or CEN 4 Security Front Access Short with CEN L Security Front Access Short with Business Hours Security Front Access Short with German Standard or Standard Security Rear Access with Standard Security Rear Access with German Standard Security Rear Access with CEN A3 Security Rear Access with CEN L Security Vestibule with Standard Security Vestibule with German Standard Security Vestibule with CEN A3 Security Vestibule with CEN L Security Advert Light

2-54 2-54 2-55 2-55 2-55 2-56 2-56 2-56 2-56 2-56 2-56 2-56 2-57 2-57 2-57 2-57 2-57 2-57 2-57 2-57

Access for All Front Access Short, Business Hours, German, CEN 3 and CEN 4 Security

2-58 2-58

NCR Personas 77 ATM Site Preparation

Table of Contents Physical Requirements

Front Access Stretch, Rear Access and Vestibule Heights to Main Facia Items Lobby Variants Vestibule Variants Recommended Wheelchair Clearance

2-58 2-58 2-59 2-60 2-61

Internal Space Constraint for Fitting a Third Party Video Camera

2-62

NCR Personas 77 ATM Site Preparation

Physical Requirements

Overview

Overview
The NCR Personas 77 ATM is a self-service ATM which may be installed in any suitable interior location. The ATM is available in Front Access Lobby, Rear Access Lobby and Rear Access Vestibule configurations. The ATM is designed to provide a range of services such as: Cash withdrawals Receipt printing Cheque book requests Account enquiries Bill payments.

NCR Personas 77 ATM Site Preparation

2-1

Physical Requirements Customer Responsibilities

Customer Responsibilities
The customer must do or provide the following: When required by NCR, provide the NCR customer service representative with appropriate drawings that indicate: Location of the equipment Site wiring (power and signal, paths and lengths) Location of other equipment capable of generating electrical noise, electromagnetic interference, heat, etc. Make building alterations necessary to meet wiring and other site requirements Provide and install all communications cables, wall jacks, special connectors and associated hardware Provide and install necessary power distribution boxes, conduits, grounds, lightning protection and associated hardware Make sure all applicable codes, regulations and laws (including but not limited to electrical, building, safety and health, disabilities) are met Provide and install auxiliary power or other equipment as required Provide storage or service areas as required Make sure the environmental requirements of the system/unit are met Provide floor coverings and environmental systems that limit or control static electricity build-up and discharge.

2-2

NCR Personas 77 ATM Site Preparation

Physical Requirements Product Identification

Product Identification
The product is identified by a class type number (5877), and a 4-digit model number which is printed on a label (similar to the following) attached to the inside wall of the ATM near the ON/OFF switch. The first two digits of this model number identify the major model (normally 01), the next two digits identify the minor model (normally 01). The serial number is unique to each ATM, as is the Class number combined with the Tracer number.

Class: 5877
NCR Global Solutions Ltd.
Made in UK

Model: XXXX

Serial: 08-XXXXXXXX Tracer: 08-XXXXX Vac: 220 - 240 Hz: 50/60 A:6.3

LISTED 649R Automated Teller Machine 24 Hour Service Level 1

LR 32207

Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio Interference Regulations of Canada. Le present appariel nemet pas de bruits radioelectriques depassant les limites de la classe A prescrites dans le Reglement sur le brouillage radioelectrique du Canada. Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J

NCR Personas 77 ATM Site Preparation

2-3

Physical Requirements Packaging Dimensions

Packaging Dimensions
The type of packaging used is dependent on the shipping method - road or air/sea freight. If access to the installation location is not wide enough to allow the package to pass through, unpack the ATM in an area with sufficient access.

Front Access Short, Business Hours, German Standard, and CEN

800 mm (31.50 in.)


2

1150 mm (45.28 in.)

1750 mm (68.90 in.)

1640 mm (64.57 in.)

1200 mm (47.24 in.) 800 mm (31.50 in.)

Air and Sea

Road

2-4

NCR Personas 77 ATM Site Preparation

Physical Requirements Packaging Dimensions

Front Access Stretch and Rear Access

820 mm (32.3 in.)

1220 mm (48.0 in.)

1911 mm (75.2 in.)

1765 mm (69.5 in.)

1200 mm (47.2 in.) 800 mm (31.5 in.)

Air and Sea

Road

NCR Personas 77 ATM Site Preparation

2-5

Physical Requirements Packaging Dimensions

Vestibule

820 mm (32.3 in.)

1220 mm (48.0 in.)

1911 mm (75.2 in.)

1850 mm (72.8 in.)

1200 mm (47.2 in.) 800 mm (31.5 in.)

Air and Sea

Road

2-6

NCR Personas 77 ATM Site Preparation

Physical Requirements Packaging Dimensions

Advert Light Package

530 mm (20.9 in.)

250 mm (9.8 in.)

140 mm (5.5 in.)

NCR Personas 77 ATM Site Preparation

2-7

Physical Requirements ATM Dimensions

ATM Dimensions
Business Hours Security

Security Enclosure Variants

The Business Hours Security variant complies with this security standard.
2

UL 291 (Level 1) Standard Security


Two variants are available that comply with this security standard: Standard Security German Standard. The main external dimensions of the Standard Security and German Standard enclosure variants are the same.

CEN Security
Three variants are available that comply with this security standard: CEN 3 CEN 4 (front access only) CEN L.

2-8

NCR Personas 77 ATM Site Preparation

Physical Requirements ATM Dimensions

Front Access Terminals

Short, Standard, Business Hours and German Standard Security with Advert Light
2

494 mm (19.4 in.)

1455mm (57.3 in.)

1508 mm (59.4 in.)

1685mm (66.3 in.)

768 mm (30.2 in.)

732 mm (28.8 in.) 832 mm (32.8 in.)

476 mm (18.7 in.)

Note: A Personas 72 sidecar may be used in conjunction with the Front Access, Short, Business Hours and German Standard Security version of the ATM. Dimensions and Installation/Service clearance information for the sidecar are contained in the Personas 72 Sidecar Site Preparation Bookset, B006-6216.

NCR Personas 77 ATM Site Preparation

2-9

Physical Requirements ATM Dimensions

Stretch, Standard Security

1520 mm (59.8 in.)

1573 mm (61.9 in.)

732 mm (28.8 in.)

476 mm (18.7 in.)

1335 mm (52.6 in.)

2-10

NCR Personas 77 ATM Site Preparation

Physical Requirements ATM Dimensions

CEN 3, CEN 4 and CEN L with Advert Light


789 mm (31.0 in.) 494 mm (19.4 in.)

1455 mm (57.3 in.)

1508 mm (59.4 in.)

1685 mm (66.3 in.)

768 mm (30.2 in.)

770 mm (30.3 in.) 870 mm (34.2 in.)

See Note

Note: CEN 3 and CEN 4 = 525 mm (20.7 in.); CEN L = 500 mm (19.7 in.).

NCR Personas 77 ATM Site Preparation

2-11

Physical Requirements ATM Dimensions

Rear Access, Lobby

Rear Access, Standard and German Standard Security


2

1605 mm (63.2 in.) 1555 mm 61.2 in.)

780 mm (30.7 in.) 880 mm (34.6 in.)

470 mm (18.5 in.)

2-12

NCR Personas 77 ATM Site Preparation

Physical Requirements ATM Dimensions

Rear Access, CEN 3 and CEN L Security

1605 mm (63.2 in.) 1555 mm 61.2 in.)

835 mm (32.9 in.) 935 mm (36.8 in.)

See Note

Note: CEN 3 = 525 mm (20.7 in.); CEN L = 500 mm (19.7 in.).

NCR Personas 77 ATM Site Preparation

2-13

Physical Requirements ATM Dimensions

Vestibule Terminals

Vestibule, Standard and German Standard Security


2

545 mm (24.5 in.) 65 mm (2.6 in.) 45 mm (1.8 in.) 45 mm (1.8 in.) Advert Collar 35 mm (1.4 in.) 50 mm 87 mm (2.0 in.) (3.4 in.) 610 mm (24.0 in.) D 642 mm (25.3 in.) 150 mm (5.9 in.) 15 mm (0.6 in.)

575 mm (22.6 in.)

917 mm (36.1 in.)

1006 mm (39.6 in.)

1555 mm (61.2 in.) 980 mm (17.0 in.) 41 mm (1.6 in.) B C 725 mm (28.5 in.)

1690 mm (66.5 in.)

684 mm (26.9 in.)

720 mm (28.3 in.) A

470 mm (18.5 in.)

111 mm (4.4 in.)

Note: The Vestibule variant is supplied with a sleeve suitable for either a Five Inch Wall (F009) or an Eight Inch Wall (F068).

2-14

NCR Personas 77 ATM Site Preparation

Physical Requirements ATM Dimensions

The following table shows the dimensions.


Five Inch Wall (F009) Eight Inch Wall (F068)

A B C D

879 mm (34.6 in.) 144 mm (5.7 in.) 159 mm (6.3 in.) 280 mm (11.0 in.)

955 mm (37.6 in.) 220 mm (8.7 in.) 235 mm (9.3 in.) 356 mm (14.0 in.)

NCR Personas 77 ATM Site Preparation

2-15

Physical Requirements ATM Dimensions

Vestibule CEN 3 Security


545 mm (24.5 in.) 20 mm (0.8 in.) 45 mm (1.8 in.) 45 mm (1.8 in.) Advert Collar 35 mm (1.4 in.) 50 mm 87 mm (2.0 in.) (3.4 in.) 610 mm (24.0 in.) D 642 mm (25.3 in.) 150 mm (5.9 in.) 15 mm (0.6 in.)

575 mm (22.6 in.)

917 mm (36.1 in.)

1006 mm (39.6 in.)

1555 mm (61.2 in.) 980 mm (17.0 in.) 41 mm (1.6 in.) B C 725 mm (28.5 in.)

1690 mm (66.5 in.)

684 mm (26.9 in.)

775 mm (30.5 in.) A

525 mm (20.7 in.)

111 mm (4.4 in.)

Note: The Vestibule variant is supplied with a sleeve suitable for either a Five Inch Wall (F009) or an Eight Inch Wall (F068).

2-16

NCR Personas 77 ATM Site Preparation

Physical Requirements ATM Dimensions

The following table shows the dimensions.


Five Inch Wall (F009) Eight Inch Wall (F068)

A B C D

934 mm (36.8 in.) 144 mm (5.7 in.) 159 mm (6.3 in.) 280 mm (11.0 in.)

1010 mm (39.8 in.) 220 mm (8.7 in.) 235 mm (9.3 in.) 356 mm (14.0 in.)

NCR Personas 77 ATM Site Preparation

2-17

Physical Requirements ATM Dimensions

Vestibule CEN L
553 mm (21.8 in.) 53 mm (2.1 in.) 45 mm (1.8 in.) 45 mm (1.8 in.) Advert Collar 35 mm (1.4 in.) 50 mm 87 mm (2.0 in.) (3.4 in.) 610 mm (24.0 in.) D 545 mm (24.5 in.) 642 mm (25.3 in.) 150 mm (5.9 in.) 15 mm (0.6 in.)

575 mm (22.6 in.)

917 mm (36.1 in.)

1006 mm (39.6 in.)

1555 mm (61.2 in.) 980 mm (17.0 in.) 41 mm (1.6 in.) B C 725 mm (28.5 in.)

1690 mm (66.5 in.)

684 mm (26.9 in.)

775 mm (30.5 in.) A

500 mm (19.7 in.)

98 mm (3.9 in.)

Note: The Vestibule variant is supplied with a sleeve suitable for either a Five Inch Wall (F009) or an Eight Inch Wall (F068).

2-18

NCR Personas 77 ATM Site Preparation

Physical Requirements ATM Dimensions

The following table shows the dimensions.


Five Inch Wall (F009) Eight Inch Wall (F068)

A B C D

934 mm (36.8 in.) 144 mm (5.7 in.) 159 mm (6.3 in.) 280 mm (11.0 in.)

1010 mm (39.8 in.) 220 mm (8.7 in.) 235 mm (9.3 in.) 356 mm (14.0 in.)

NCR Personas 77 ATM Site Preparation

2-19

Physical Requirements Installation and Service Clearances

Installation and Service Clearances


The following illustrations show both minimum and recommended floor areas required for installing, servicing and replenishing the ATM. Use of the minimum clearances may require removal of modules to allow sufficient access for servicing and may therefore increase service costs. Clearance illustrations indicate a 38 mm (1.5 in.) ventilation space around the ATM. This space is required to provide sufficient airflow to allow the ATMs cooling system to function effectively. Note: The power and communications cables should be installed within the ATM prior to final siting.

2-20

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Front Access - Service Footprints

Front Access Short and Business Hours Security, Minimum Service Footprint
2

1306 mm (51.4 in.)

720 mm (28.3 in.)

658 mm (26.0 in.)

38 mm (1.5 in.) Ventilation Space

460 mm (18.1 in.)

546 mm (21.5 in.)

300 mm (11.8 in.)

NCR Personas 77 ATM Site Preparation

2-21

Physical Requirements Installation and Service Clearances

Front Access Short and Business Hours Security, Recommended Service Footprint

1386 mm (54.6 in.)

930 mm (36.6 in.)

658 mm (26.0 in.)

38 mm (1.5 in.) Ventilation Space

480 mm (18.9 in.)

546 mm (21.5 in.)

360 mm (14.2 in.)

2-22

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Front Access Stretch and German Standard Security, Minimum Service Footprint
1146 mm (45.1 in.)

720 mm (28.3 in.)

658 mm (26.0 in.) 38 mm (1.5 in.) Ventilation Space

300 mm (11.8 in.)

546 mm (21.5 in.)

300 mm (11.8 in.)

Note: A Personas 72 sidecar may be used in conjunction with the Front Access Short and German Standard Security versions of the Personas77. Dimensions and Installation/Service clearance information for the sidecar are contained in the Personas 72 Sidecar Site Preparation Bookset, B0066216.

NCR Personas 77 ATM Site Preparation

2-23

Physical Requirements Installation and Service Clearances

Front Access Stretch and German Standard Security, Recommended Service Footprint
1486 mm (58.5 in.)

930 mm (36.6 in.)

658 mm (26.0 in.)

38 mm (1.5 in.) Ventilation Space

480 mm (18.9 in.)

546 mm (21.5 in.)

360 mm (14.2 in.)

Note: A Personas 72 sidecar may be used in conjunction with the Front Access Short and German Standard Security version of the Personas 77. Dimensions and Installation/Service clearance information for the sidecar

2-24

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

are contained in the Personas 72 Sidecar Site Preparation Bookset, B0066216.

Front Access CEN 3 and CEN 4 Security, Minimum Service Footprint

1201 mm (47.3 in.)

720 mm (28.3 in.)

658 mm (26.0 in.) 38 mm (1.5 in.) Ventilation Space

300 mm (11.8 in.)

601 mm (23.7 in.)

300 mm (11.8 in.)

NCR Personas 77 ATM Site Preparation

2-25

Physical Requirements Installation and Service Clearances

Front Access CEN 3 and CEN 4 Security, Recommended Service Footprint

1486 mm (58.5 in.)

930 mm (36.6 in.)

658 mm (26.0 in.)

38 mm (1.5 in.) Ventilation Space

38 mm (1.5 in.) Ventilation Space

480 mm (18.9 in.)

601 mm (23.7 in.)

360 mm (14.2 in.)

2-26

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Front Access CEN L Security, Minimum Service Footprint

1310 mm (51.6 in.) (If shelf fitted) 1176 mm (46.3 in.)

Optional Shelf

720 mm (28.3 in.)

75 mm (3.0 in.) (If shelf fitted)

150 mm (5.9 in.) (If shelf fitted) 38 mm (1.5 in.)

300 mm (11.8 in.) 720 mm (28.3 in.)

576 mm (22.7 in.)

NCR Personas 77 ATM Site Preparation

2-27

Physical Requirements Installation and Service Clearances

Front Access CEN L Security, Recommended Service Footprint


1516 mm (59.7 in.)

Optional Shelf

930 mm (36.6 in.)

75 mm (3.0 in.) (If shelf fitted)

150 mm (5.9 in.) (If shelf fitted) 38 mm (1.5 in.)

360 mm (14.4 in.) 720 mm (28.3 in.)

576 mm (22.7 in.)

2-28

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Rear Access - Service Footprints

Rear Access, Standard and German Standard Security, Minimum Service Footprint
2

546mm (21.5in.)

762mm (30in.)

Ventilation Space 38mm (1.5in.) 122mm (4.8in.) 38mm (1.5in.) 100mm (3.9in.) Cable Conduit

1492mm (58.7in.)

100mm (3.9in.)

60mm (2.4in.) 755mm (29.7in.)

790mm (31.1in.)

NCR Personas 77 ATM Site Preparation

2-29

Physical Requirements Installation and Service Clearances

Rear Access, Standard and German Standard Security, Recommended Service Footprint
546mm (21.5in.)

762mm (30in.)

1577mm (62.1in.) Ventilation Space

38 mm (1.5 in.) 472mm (18.6in.)

38 mm (1.5 in.)

100mm (3.9in.)

1040mm (40.9in.)

1490mm (58.7in.)

2-30

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Rear Access, CEN 3 Security, Minimum Service Footprint


601 mm (23.7 in.)

762 mm (30 in.)

1737 mm (68.4 in.) Ventilation Space 38 mm (1.5 in.) 38 mm (1.5 in.) 122 mm (4.8 in.)

100mm (3.9in.)

720 mm (28.3 in.)

1165 mm (45.9 in.)

NCR Personas 77 ATM Site Preparation

2-31

Physical Requirements Installation and Service Clearances

Rear Access, CEN 3 Security, Recommended Service Footprint


601 mm (23.7 in.)

762 mm (30 in.)

Ventilation Space

1737 mm (68.4 in.)

38 mm (1.5 in.) 472 mm (18.6 in.)

38 mm (1.5 in.)

100mm (3.9in.)

1040 mm (40.9 in.)

1490 mm (58.7 in.)

2-32

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Rear Access CEN L Security, Minimum Service Footprint


576 mm (22.7 in.)

762 mm (30.0 in.)

1527 mm (60.1 in.)

Ventilation Space 38 mm (1.5 in.) 38 mm (1.5 in.) 266 mm (10.5 in.) 100 mm (3.9 in.)

30 mm (1.2 in.) 720 mm (28.3 in.)

934 mm (36.8 in.)

NCR Personas 77 ATM Site Preparation

2-33

Physical Requirements Installation and Service Clearances

Rear Access, CEN L Security, Recommended Service Footprint


576 mm (22.7 in.)

762 mm (30.0 in.)

1527 mm (60.1 in.)

Ventilation Space 38 mm (1.5 in.) 38 mm (1.5 in.) 472 mm (18.6 in.) 100 mm (3.9 in.) 380 mm (15.0 in.)

1040 mm (40.9 in.)

1490 mm (58.7 in.)

2-34

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Vestibule Terminal Service Footprints

Vestibule, Standard and German Standard Security, Minimum Service Footprint


2

642 mm (25.3 in.)

762 mm (30 in.)

Ventilation Space 38 mm (1.5 in.) 130mm (5.1in.) 160mm (6.3in.) 100mm (3.9in.)

720 mm (28.3 in.)

1080 mm (42.6 in.)

NCR Personas 77 ATM Site Preparation

2-35

Physical Requirements Installation and Service Clearances

Vestibule, Standard and German Standard Security, Recommended Service Footprint


642 mm (25.3 in.)

762 mm (30 in.)

130mm (5.1in.) 510 mm (20.1 in.)

Ventilation Space 38 mm (1.5 in.) 100mm (3.9in.)

1040 mm (40.9 in.)

1490 mm (58.7 in.)

2-36

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Vestibule, CEN 3 Security, Minimum Service Footprint


642 mm (25.3 in.)

762 mm (30.0 in.)

130mm (5.1in.)

Ventilation Space 38 mm (1.5 in.)

160 mm (6.3 in.)

100mm (3.9in.)

720 mm (28.3 in.)

1165 mm (45.9 in.)

NCR Personas 77 ATM Site Preparation

2-37

Physical Requirements Installation and Service Clearances

Vestibule, CEN 3 Security, Recommended Service Footprint


642 mm (25.3 in.)

762 mm (30.0 in.)

130mm (5.1in.)

Ventilation Space 38 mm (1.5 in.)

510 mm (20.1 in.)

100mm (3.9in.)

1040 mm (40.9 in.)

1545 mm (60.8 in.)

2-38

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Vestibule, CEN L Security, Minimum Service Footprint


642 mm (25.3 in.)

762 mm (30.0 in.)

130mm (5.1in.) 174 mm (6.3 in.)

Ventilation Space

38 mm (1.5 in.) 100mm (3.9in.)

30mm (1.2in.) 720 mm (28.3 in.)

934 mm (36.8 in.)

NCR Personas 77 ATM Site Preparation

2-39

Physical Requirements Installation and Service Clearances

Vestibule, CEN L Security, Recommended Service Footprint


642 mm (25.3 in.)

762 mm (30.0 in.)

130mm (5.1in.)

Ventilation Space

38 mm (1.5 in.) 380mm (15.0in.) 100mm (3.9in.) 380mm (15.0in.)

1040 mm (40.9 in.)

1490 mm (58.7 in.)

2-40

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Securing Bolt Location Points, Lobby Terminals

The following illustrations show the dimensions for the securing bolt location points viewed from above.
2

Lobby - Short Standard, German Standard, CEN 3 and CEN 4 Security, Front Access
235 mm (9.3 in.)

28 mm Dia (1.1 in.)

150 mm (5.9 in.)

160 mm (6.3 in.)

160 mm (6.3 in.) 265 mm (10.4 in.) Safe Door 123 mm (4.8 in.)

NCR Personas 77 ATM Site Preparation

2-41

Physical Requirements Installation and Service Clearances

Lobby - Business Hours Security, Front Access

323 mm (12.7 in.) 175 mm (6.9 in.)

5 mm (0.2 in.) R 8 mm (0.3 in.)

428.5 mm (16.9 in.)

120 mm (4.7 in.)

Safe Door

2-42

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Lobby - Stretch Standard Security, Front Access

313 mm (12.3 in.)

580 mm (22.8 in.)

28 mm Dia (1.1 in.)

410 mm (16.1 in.)

14 mm Dia (0.6 in.) 315 mm (12.4 in.) Safe Door 123 mm (4.8 in.)

160 mm (6.3 in.)

NCR Personas 77 ATM Site Preparation

2-43

Physical Requirements Installation and Service Clearances

Lobby - CEN L Security, Front Access


402.5 mm (15.8 in.) 265 mm (10.4 in.)

28 mm (1.1 in.) Dia. Typical

410 mm (16.1 in.)

160 mm (6.3 in.)

Safe Door

271 mm (10.7 in.)

92 mm (3.6 in.)

Note: The hole marked * has a larger countersink to accommodate an optional alarm bolt.

2-44

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Lobby, Standard Security, Rear Access

410 mm (16.1 in.) 235 mm (9.3 in.) 28 mm (1.1 in.) Dia. Typical

549 mm (21.6 in.)

140 mm (5.5 in.) 275 mm (10.8 in.)

120 mm (4.7 in.)

Safe Door

NCR Personas 77 ATM Site Preparation

2-45

Physical Requirements Installation and Service Clearances

Lobby, German Standard Security, Rear Access

235mm (9.3in.) 25mm (1.0in.) Dia.

429mm (16.9in.)

120mm (4.7in.) 275mm (10.8in.)

25mm (1.0in.) Dia. Safe Door

2-46

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Lobby, CEN 3 and CEN 4 Security, Rear Access


28 mm (1.1 in.) Dia. Typical 200 mm (7.9 in.) 100 mm (3.9 in.)

648 mm (25.5 in.)

367 mm (14.4 in.)

*
86 mm (3.4 in.)

Safe Door

332 mm (13.1 in.)

Note: The hole marked * has a larger countersink to accommodate an optional alarm bolt.

NCR Personas 77 ATM Site Preparation

196 mm ( 7.7 in.)

538 mm (21.2 in.)

2-47

Physical Requirements Installation and Service Clearances

Lobby, CEN L Security, Rear Access


187.5 mm (7.38 in.) 28 mm (1.1 in.) Dia. Typical

87.5 mm (3.44 in.)

648 mm (25.5 in.)

367 mm (14.4 in.)

*
86 mm (3.4 in.)

Safe Door

332 mm (13.1 in.)

Note: The hole marked * has a larger countersink to accommodate an optional alarm bolt.

2-48

NCR Personas 77 ATM Site Preparation

196 mm ( 7.7 in.)

538 mm (21.2 in.)

Physical Requirements Installation and Service Clearances

Securing Bolt Location Points, Vestibule Terminals

The following illustrations show the dimensions for the securing bolt location points viewed from above.

Vestibule, Standard Security Variant, Rear Access


2

Centre-line of hole in wall 65 mm (2.6 in.) 28 mm (1.1 in.) Dia. typical

140 mm (5.5 in.) 120 mm (4.7 in.)

429 mm (16.9 in.)

95 mm (3.7 in.) 135 mm (5.3 in.) 270 mm (10.6 in.)

Safe Door

Note: The Vestibule variant is supplied with a sleeve suitable for either a Five Inch Wall (F009) or an Eight Inch Wall (F068). The following table shows the dimensions.
Five Inch Wall (F009) Eight Inch Wall (F068)

689 mm (27.1 in.)

765 mm (30.1 in.)

NCR Personas 77 ATM Site Preparation

2-49

Physical Requirements Installation and Service Clearances

Vestibule, German Standard Security Variant, Rear Access


Centre-line of hole in wall 68 mm (2.7 in.) 25 mm (1.0 in.) Dia. typical

A 120 mm (4.7 in.) 429 mm (16.9 in.)

40 mm (1.6 in.) 275 mm (10.8 in.)

Note: The Vestibule variant is supplied with a sleeve suitable for either a Five Inch Wall (F009) or an Eight Inch Wall (F068). The following table shows the dimensions.
Five Inch Wall (F009) Eight Inch Wall (F068)

689 mm (27.1 in.)

765 mm (30.1 in.)

2-50

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Vestibule, CEN 3 Security, Rear Access


Centre-line of hole in wall 90 mm (3.5 in.) 28 mm (1.1 in.) Dia. Typical

281 mm (11.1 in.) 342 mm 562 mm (13.5 in.) (22.1 in.) 86 mm (3.4 in.)

*
132 mm (5.2 in.) 270 mm (10.6 in.) 110 mm 100 mm (4.3 in.) (3.9 in.)

Note: The Vestibule variant is supplied with a sleeve suitable for either a Five Inch Wall (F009) or an Eight Inch Wall (F068). The following table shows the dimensions.
Five Inch Wall (F009) Eight Inch Wall (F068)

790 mm (31.1 in.)

866 mm (34.1 in.)

Note: The hole marked * has a larger countersink to accommodate an optional alarm bolt.

NCR Personas 77 ATM Site Preparation

2-51

Physical Requirements Installation and Service Clearances

Vestibule, CEN L Security, Rear Access


Centre-line of hole in wall 90 mm (3.5 in.) 28 mm (1.1 in.) Dia. Typical

281 mm (11.1 in.) 342 mm 562 mm (13.5 in.) (22.1 in.) 86 mm (3.4 in.)

*
132 mm (5.2 in.) 312.5 mm (12.3 in.) 100 mm (3.9 in.) 110 mm (4.3 in.)

Note: The Vestibule variant is supplied with a sleeve suitable for either a Five Inch Wall (F009) or an Eight Inch Wall (F068). The following table shows the dimensions.
Five Inch Wall (F009) Eight Inch Wall (F068)

790 mm (31.1 in.)

866 mm (34.1 in.)

Note: The hole marked * has a larger countersink to accommodate an optional alarm bolt.

2-52

NCR Personas 77 ATM Site Preparation

Physical Requirements Installation and Service Clearances

Hole in the Wall Dimensions Vestibule Terminal

565 mm (22.2 in.)


2

565 mm (22.2 in.)

935mm (36.8 in.)

1100 mm (43.3 in.)

715 mm (28.2 in.)

715 mm (28.2 in.)

Without Advert Light

With Advert Light

NCR Personas 77 ATM Site Preparation

2-53

Physical Requirements Requirements for the Floor

Requirements for the Floor


The ATM is suitable for mounting on concrete or other non-combustible surface only. The ATM must be bolted to the floor using the correct number of security bolts. The number of bolts is as follows:

Security Bolts

Standard, Front Access German Standard, Business Hours, CEN 3, CEN 4 and CEN L Security - four bolts Rear Access German Standard Security - two bolts.

Note: The securing bolts and washers must be supplied by the owning organisation. The floor must be capable of withstanding the loading imposed by the anchor points for the bolts. Warning It is particularly important in the case of the Business Hours security enclosure, that it is bolted to the floor. The minimum specification for bolts to secure the ATM to a plinth or a stone/concrete floor is, high tensile M16 anchor bolts with appropriate washers of 6 mm (0.24 in.) minimum thickness. It is recommended that these bolts be a minimum depth of 150 mm (5.91 in.) and that either resin anchor bolts or expanding anchor bolts are used.

2-54

NCR Personas 77 ATM Site Preparation

Physical Requirements Requirements for the Floor

Note: Bolting of CEN security enclosures should comply with the requirements of EN 1143-1 (CEN Safe Burglary Standard).
Tighten only to compress Spring Washer

Anchor Washer

Safe

Ground

Anchor Bolt

Floor Covering ATM Location Ambient Lighting

An antistatic floor covering should be used. This floor covering should be of a type which will not generate dust or fluff. The ATM should not be located in a position where bright sunlight will fall directly on the screen. If the ATM is fitted with a video camera it is strongly recommended that there is a minimum of 50 LUX lighting at floor level within an area 1000 mm (39.37 in.) wide by 1500 mm (59.1 in.) deep at the front of the ATM. This lighting conforms to the following;

Australian Standard for Automatic Teller Machines (1991) Lighting for Automated Teller Machines as prepared by the Illuminating Engineers Society of North America.

Note A minimum of 200 LUX is recommended for task lighting.

NCR Personas 77 ATM Site Preparation

2-55

Physical Requirements Requirements for the Floor

Weight and Floor Loading

If the ATM is to be bolted to the floor, the floor must be solid, level and capable of supporting the maximum weight. The weight of the ATM varies with configuration and variant of terminal, however, only the maximum weight should be considered since additional options may be added after installation. Note: Floor loading is calculated by dividing the maximum weight of the ATM by the surface area of the ATM base (the area in contact with the floor).

Front Access Stretch with Standard Security


Maximum Weight Packed - 535 kg (11791 lb.) Maximum Weight Unpacked - 525 kg (1157 lb.) Floor Loading - 1507 kg/m2 (309 lb./ft2).
2

Front Access Short with CEN 3 or CEN 4 Security


Maximum Weight Packed - 663 kg (1462 lb.) Maximum Weight Unpacked - 593 kg (1307 lb.) Floor Loading - 1467 kg/m2 (301 lb./ft2).
2

Front Access Short with CEN L Security


Maximum Weight packed - 541 kg (1193 lb.) Maximum Weight Unpacked - 506 kg (1115.7 lb.) Floor Loading - 1484 kg/m2 (304 lb./ft2).
2

Front Access Short with Business Hours Security


Maximum Weight Packed - 260 kg (573 lb.) Maximum Weight Unpacked - 166 kg (366 lb.) Floor Loading - 505 kg/m2 (103.3 lb./ft2).

Front Access Short with German Standard or Standard Security


Maximum Weight Packed - 496 kg (1094 lb.) Maximum Weight Unpacked - 426 kg (939 lb.) Floor Loading - 1223 kg/m2 (251 lb./ft2).
2

Rear Access with Standard Security


Maximum Weight Packed - 510 kg (1125 lb.) Maximum Weight Unpacked - 482 kg (1063 lb.) Floor Loading - 1554 kg/m2 (318.2 lb./ft2).

2-56

NCR Personas 77 ATM Site Preparation

Physical Requirements Requirements for the Floor

Rear Access with German Standard Security


Maximum Weight Packed - 563 kg (1241 lb.) Maximum Weight Unpacked - 538 kg (1186 lb.) Floor Loading -1734 kg/m2 (355.2 lb./ft2).
2

Rear Access with CEN A3 Security


Maximum Weight Packed - 619 kg (1365 lb.) Maximum Weight Unpacked - 594 kg (1310 lb.) Floor Loading - 1554 kg/m2 (318.3 lb./ft2).
2

Rear Access with CEN L Security


Maximum Weight Packed - 541 kg (1193 lb.) Maximum Weight Unpacked - 506 kg (1115.7 lb.) Floor Loading - 1438 kg/m2 (294.4 lb./ft2).
2

Vestibule with Standard Security


Maximum Weight Packed - 570 kg (1257 lb.) Maximum Weight Unpacked - 545 kg (1202 lb.) Floor Loading -1757 kg/m2 (359.8 lb./ft2).
2

Vestibule with German Standard Security


Maximum Weight Packed - 598 kg (1319 lb.) Maximum Weight Unpacked - 573 kg (1263 lb.) Floor Loading - 1847 kg/m2 (378.3 lb./ft2).
2

Vestibule with CEN A3 Security


Maximum Weight Packed - 654 kg (1442 lb.) Maximum Weight Unpacked - 629 kg (1387 lb.) Floor Loading -1646 kg/m2 (337.0 lb./ft2).
2

Vestibule with CEN L Security


Maximum Weight Packed - 549 kg (1211 lb.) Maximum Weight Unpacked - 522 kg (1151 lb.) Floor Loading - 1483 kg/m2 (303.7 lb./ft2).
2

Advert Light

Maximum Weight Packed - 7 kg (16 lb.) Maximum Weight Unpacked - 6 kg (13 lb.).

NCR Personas 77 ATM Site Preparation

2-57

Physical Requirements Access for All

Access for All


The Personas 77 is designed to meet optimum height and reach requirements to provide comfortable access for all users. This design takes account of wheelchair users, the visually impaired and all others. For wheelchair users, optimized parallel approach is offered, providing security and private space if installed according to recommendations. The Front Access Short, Business Hours, German Standard, CEN 3 and CEN 4 variants comply with all height and reach requirements.

Front Access Short, Business Hours, German, CEN 3 and CEN 4 Security Front Access Stretch, Rear Access and Vestibule

The Front Access Stretch and Rear Access Lobby and Vestibule variants do not comply with some accessibility requirements for UK, USA, Canada, Australia, Netherlands and New Zealand. Accessibility requirements vary by country. Please contact NCR Sales Support if further information is required. The following illustrations and tables shows the heights and depths to the main items, or exit slots, located on the ATM facia:

Heights to Main Facia Items

heights - from the ATM base (safe floor) depths - from the front of the terminal with the exception of the barcode reader position which is taken from the front of the optional shelf.

2-58

NCR Personas 77 ATM Site Preparation

Physical Requirements Access for All

Lobby Variants

K J H A

B F C

D E A B C
J

F G
D E

A
Top FDK Key

B
Display

E
Barcode Contactless Reading Card Reader Position (in shelf) *

F
Card Reader

G
Receipt

H
Audio Jack Plug

J
Speaker

K
Camera Window

No. 5 Key Cash Exits 1 and 2

JKL

SS
789.0 mm (31.0 in.) 1050.0 mm 1161.0 mm 1180.0 mm 1380 mm 1439.0 mm (41.30 in.) (45.70 in.) (46.46 in.) (54.33 in.) (56.60 in.)

Front Access Short, Business Hours, German Standard Security, CEN 3 and CEN 4 - Module Heights (from Base of Terminal) 1138.0 mm 1116.0 mm 934.0 mm 825.0 mm (44.80 in.) (43.90 in.) (36.80 in.) (32.50 in.)

F/A Stretch - Module Heights (from Base of Terminal) 1203.8 mm 1181.0 mm 1004.0 mm 890.0 mm (47.40 in.) (46.50 in.) (39.50 in.) (35.00 in.) N/A 1115.0 mm 1226.0 mm 1180.0 mm 1445 mm (43.9 in.) (48.30 in.) (46.46 in.) (56.89 in.) N/A

Depth (from front of Terminal) 151.0 mm 150.5 mm 116.0 mm (5.94 in.) (5.93 in.) (4.57 in.) 46.5 mm (1.83 in.) 116.0 mm (4.57 in.) 69.3 mm (2.73 in.) 138.0 mm 105.0 mm (5.43 in.) (4.13 in.) 130.0 mm 87.0 mm (5.12 in.) (3.43 in.)

Note:* This is on the optional shelf. The depth given, for this module, is taken from the front of the shelf

NCR Personas 77 ATM Site Preparation

2-59

Physical Requirements Access for All

Vestibule Variants

G A

F B E C D

A B C

E F
D

A
Top FDK Key

B
Display

C
No. 5 Key
5

D
Cash Exit

E
Card Reader

F
Receipt

G
Audio Jack Plug

JKL

SS
924 mm (36.4 in.) 1149 mm (45.2 in.) 1260 mm (49.6 in.) 1279 mm (50.4 in.)

Module heights (from base of terminal) 1237 mm (48.7 in.) 1215 mm (47.8 in.) 1033 mm (40.7 in.)

Depth from front of terminal ( five inch sleeve) 210 mm (8.3 in.) 209 mm (8.2 in.) 175 mm (6.9 in.) 106 mm (4.2 in.) 128 mm (5.0 in.) 197 mm (7.8 in.) 164 mm (6.5 in.)

Depth from front of terminal (eight inch sleeve) 286 mm (11.3 in.) 285 mm (11.2 in.) 251 mm (9.9 in.) 182 mm (7.2 in.) 204 mm (8.0 in.) 273 mm (10.8 in.) 240 mm (9.5 in.)

2-60

NCR Personas 77 ATM Site Preparation

The following illustration shows the recommended clearance for wheelchair approach.

Physical Requirements Access for All

Recommended Wheelchair Clearance

1500 mm (59.1 in.)

Wheelchair Turning Circle O 1500mm

1500 mm (59.1 in.)

750 mm (29.5 in.)

c L

750 mm (29.5 in.)

NCR Personas 77 ATM Site Preparation

2-61

Physical Requirements Internal Space Constraint for Fitting a Third Party Video Camera

Internal Space Constraint for Fitting a Third Party Video Camera


If a third party video camera is to be installed, there is a space constraint to consider. The location of the video camera is directly behind the camera window on the fascia. The following dimensions should be calculated from the centre point on the window, as shown in the following diagram.

P77 Facia Lens Cutout

Camera Bracket

2-62

NCR Personas 77 ATM Site Preparation

Physical Requirements Internal Space Constraint for Fitting a Third Party Video Camera

13.31 mm (0.524 in.)

90

19 mm (0.75 in.)

7 mm (0.28 in.)

16.6 mm (0.65 in.)

2.25 mm (0.089 in.)

21.7 mm (0.85 in.) 16.0 mm (0.630 in.)

58 25.5 mm (1.00 in.) 22.2 mm (0.87 in.)

122

Location of Lens Cutout in Facia

Detail

95 2. mm (0.08 in.) 4.5 mm (0.18 in.)

NCR Personas 77 ATM Site Preparation

16.4 mm (0.65 in.)

Mounting Slots Lens Centreline

45.4 mm (1.79 in.)

33 mm (1.30 in.)

2-63

Physical Requirements Internal Space Constraint for Fitting a Third Party Video Camera

2-64

NCR Personas 77 ATM Site Preparation

Table of Contents Electrical Requirements

Chapter 3

Electrical Requirements
Power Quality Distribution and Grounding Requirements AC Requirements Input Voltage Setting Power Consumption Idle Mode Under Transaction Power Cable Grounding Requirements Transient Power Loss EMI Susceptibility EMI Emission 3-1 3-1 3-1 3-1 3-1 3-1 3-1 3-3 3-3 3-3 3-3

Communications Requirements Communication Cables - Routing High Order Communications Cables HOCs Standard Cable (RS-232) - Specification and Wiring Communication Cables - Preparation HOCs Ethernet Cable - Specification and Wiring Alarm Interface Cable Alarm Interface Cable - Specification Alarm Interface Cable (Front Access Short and Rear Access) - Preparation Alarm Interface Cable (Front Access Stretch) Preparation RS232 Cable RS232 Cable -Specification RS232 Cable -Preparation Remote Relay Cable Remote Relay Cable -Specification Remote Relay Cable Preparation

3-4 3-4 3-4 3-5 3-6 3-7 3-7 3-8 3-10 3-11 3-12 3-12 3-12 3-13 3-13 3-13

NCR Personas 77 ATM Site Preparation

Table of Contents Electrical Requirements

NCR Personas 77 ATM Site Preparation

Electrical Requirements

Power Quality Distribution and Grounding Requirements

Power Quality Distribution and Grounding Requirements


Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in Appendix A and B, may be required to ensure proper operation of the equipment. The maximum current requirement at input voltage is:
3

AC Requirements

10A at 120V 6.3A at 220 - 240V.

The maximum inrush current requirement at input voltage is: 200A peak at 136V 150A peak at 257V. The ATM can operate from the following input mains voltage:

Input Voltage Setting

104V to 136V at 50/60Hz 198V to 257V at 50/60Hz. A typical power consumption rate for your ATM can be calculated from the following information:

Power Consumption

Idle Mode

180 Watts.
3

Under Transaction

430 Watts.

Note: Power consumption is dependant on the configuration and transaction rate of your ATM. The power cable supplied with the ATM is fitted with a NEMA type 5-15P power source connector. If this is not suitable for your use, it should be replaced with a suitable power source connector. This connector must be wired as shown below:

Power Cable

NCR Personas 77 ATM Site Preparation

3-1

Electrical Requirements Power Quality Distribution and Grounding Requirements

The power cable supplied is 3 m (9 ft. 9 in.) in length. If it is necessary to increase this length to meet site requirements, then the extension must satisfy local or country regulations. Warning This equipment must be earthed.

1 2 3

Live - Brown Neutral - Blue Ground - Green/Yellow

(L or Red) (N or Black) (E or Green)

Note: The annotations within brackets are included to comply with United Kingdom legislation and refer to the markings on United Kingdom three pin plugs.

3-2

NCR Personas 77 ATM Site Preparation

Electrical Requirements Power Quality Distribution and Grounding Requirements

Grounding Requirements

The ATM operates from a single phase 3 wire supply; live, neutral and ground. The power requirements of this unit will normally permit it to operate within existing wiring configurations and from existing branch mains outlets with the following provisions: 1 If this supply is provided from a general purpose distribution panel, the other branch circuits from this panel must not be used to support heavy inductive loads such as air conditioners, elevators, microwave ovens, and so on. Nor may such equipment be operated on the same branch circuit as the ATM. If using distribution panels, all branch circuit grounding conductors must be connected to an insulated terminal strip in the distribution panel. The grounding conductor from the distribution panel to the building ground point must be at least equal in size to the power conductor necessary to supply the NCR system.

Transient Power Loss EMI Susceptibility EMI Emission

Note: The building ground point can affect data integrity. For additional information refer to the Data Line Transient Protection section of Appendix A. The voltage loss due to power interruptions must not be more than 50% of the nominal value for a maximum of one half cycle at a maximum rate of 1 every 10 seconds. The ATM meets CISPR 24 and EN 55024 requirements for radiated and conducted immunity. The ATM meets the following requirements:

CISPR 22 Class A, FCC Class A and EN 55022 Class A requirements for conducted emissions. EN 61000-3-2 Class A and EN 6100-3-3, the European market requirements for 230V mains conducted emissions.

NCR Personas 77 ATM Site Preparation

3-3

Electrical Requirements Communications Requirements

Communications Requirements
Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in Appendix A, may be required to ensure proper operation of the equipment. It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with NCR specifications and requirements and with all national, state or local telephone and telegraph regulations and laws. All communication cables can be routed along an optional cable channel, which is attached to the outside of the ATM, cables enter the ATM through the cabinetry and routed to the front of the PC core. Cables should be earthed, to the PC core shelf and in the cable channel if fitted, and secured, using cable ties, to the PC core shelf along the existing cable harness where appropriate. The High Order Communications (HOCs) cable type depends upon the communications system to be used.
3

Communication Cables - Routing

High Order Communications Cables

Note: Communications cables are not supplied with the ATM. If these cables are required, it is the customers responsibility to have them installed.

3-4

NCR Personas 77 ATM Site Preparation

Electrical Requirements Communications Requirements

HOCs Standard Cable (RS-232) - Specification and Wiring


The standard high order communications system supports most common bit and byte orientated disciplines (synchronous and asynchronous) with an RS-232 interface. The interconnecting cable, from the ATM I/O panel, to the remote modem should not exceed 15.24 m (50 ft.) in length, and must conform to the specification and wiring given in the following diagram.

1, 2

1. Connector, 25 way (NCR part no. 006-0005897). 2. Terminal wire, male (NCR part no. 009-0002642). 3. Cable, multiconductor (NCR part no. 007-8907033). 4. Connector (determined by remote device). 5. Shell hood (NCR part no. 006-1500038). 6. Screw retainer (NCR part no. 601-0101584). 1 2 3 4 5 6 7 8 15 17 18 20 22 24 25 CHASSIS GND TD.V RD.V RQS.V RFS.V DSR.V SIG.GND RLSD.V TSET.V RSET.V WCA.V DTR.V CI.V EXT SET.V WIN.V

NCR Personas 77 ATM Site Preparation

3-5

Electrical Requirements Communications Requirements

Communication Cables - Preparation


Starting from the connector end, remove 20 mm (0.8 in.) sections of the outer sleeve at the distances detailed in the following table for appropriate cable and the version of terminal being installed. Note: Take care not to cut through the cable shielding when removing the outer sleeve.
20mm (0.8in.) 20mm (0.8in.)

B A
Terminal Cable Route Distance A Distance B Cable Channel Locating Holes

Standard Cable (RS232) Front Access Floor Stretch Front Access Rear of ATM Stretch Front Access Floor Short Front Access Rear of ATM Short Rear Access N/A Ethernet Cable Front Access Floor Stretch Front Access Rear of ATM Stretch

1100 mm (43.3in.) 1100 mm (43.3 in.) 1100 mm (43.3 in.) 1100 mm (43.3 in.) 400 mm (15.7 in.) 1050 mm (41.3 in.) 1050 mm (41.3 in.)

1300 mm (51.2in.) 1220 mm (48 in.) 1220 mm (48 in.) 1140 mm (44.9 in.) 1070 mm (42.1 in.) 1300 mm (51.2 in.) 1220 mm (48 in.)

Top 2nd 2nd 3rd N/A

Top 2nd

3-6

NCR Personas 77 ATM Site Preparation

Electrical Requirements Communications Requirements


Terminal Cable Route Distance A Distance B Cable Channel Locating Holes

Front Access Short Front Access Short Rear Access

Floor Rear of ATM N/A

1050 mm (41.3 in.) 1050 mm (41.3 in.) 400 mm (15.7 in.)

1220 mm (48 in.) 1140 mm (44.9 in.) 1070 mm (42.1 in.)

2nd 3rd N/A

HOCs Ethernet Cable - Specification and Wiring


A CAT5 (or higher specification) shielded cable with RJ45 connectors must be used.

HOCs Ethernet Cable - Preparation


Prepare the cable in accordance with the information detailed in the table under Communication Cables- Preparation. The ATM may, optionally, be configured to provide an alarm interface which enables the ATM to be connected to an external local alarm system. The interface may take the form of one of two options; a basic alarm system or an enhanced alarm system. The external alarm system must provide to the ATM, through the alarm interface cable wiring, a non-interruptible, stabilized power supply with the following specifications:

Alarm Interface Cable

12V + 2V dc 200mA maximum Ripple, 5% maximum.

NCR Personas 77 ATM Site Preparation

3-7

Electrical Requirements Communications Requirements

Alarm Interface Cable - Specification


The alarm interconnecting cable to the ATM is similar for both alarm interface options and must conform to the following specification:
1,2 6 5 3 4

1. Connector, 25 Way (NCR part no. 006-0005896) 2. Terminal, wire, female (NCR part no. 009-0002640) 3. Cable, multiconductor (determined by the alarm installed). Shielded cable, metal braid style with a minimum of 80% cover 4. Connector (determined by remote device). 5. Shell Hood (NCR part no. 006-1500038). 6. Screw retainer (NCR part no. 601-0101584).

3-8

NCR Personas 77 ATM Site Preparation

Electrical Requirements Communications Requirements

Alarm Interface Cable - Wiring

1 7 8 9 10 12 19 20 21 22 23 25

CHASSIS GND SILENT ALARM COMMON * DOOR ALARM N.O. DOOR ALARM N.C.. VIBRATION/HEAT COMMON +12V SILENT ALARM N.O. * SILENT ALARM N.C. * DOOR ALARM COMMON VIBRATION/HEAT N.O. VIBRATION/HEAT N.C. +12V RETURN * Optional Basic alarm interface cable wiring: CHASSIS GND TEST TRANSMITTER A TAMPER ALARM N.O. TAMPER ALARM N.C.. SILENT ALARM COMMON * DOOR ALARM N.O. DOOR ALARM N.C. COMPOSITE ATTACK COMMON +12V TEST TRANSMITTER B TAMPER ALARM COMMON SILENT ALARM N.O. * SILENT ALARM N.C. * DOOR ALARM COMMON COMPOSITE ATTACK N.O. . COMPOSITE ATTACK N.C. +12V RETURN * Optional Enhanced alarm interface cable wiring:

1 3 5 6 7 8 9 10 12 16 18 19 20 21 22 23 25

NCR Personas 77 ATM Site Preparation

3-9

Electrical Requirements Communications Requirements

Alarm Interface Cable (Front Access Short and Rear Access) Preparation
Starting from the connector end, remove 20 mm (0.8 in.) sections of the outer sleeve at the distances detailed in the following table for the cable being prepared. Note: Take care not to cut through the cable shielding when removing the outer sleeve.
20 mm (0.8 in.) 20 mm (0.8 in.) 20 mm (0.8 in.)

The following table applies to the following cables routed through the security enclosure of all versions of the ATM:

Alarm Interface Cable RS232 Cable Remote Relay Cable.


3

Front Access Safe ATM versions Distance A Distance B Distance C

Standard, Business Hours and German Standard Security Standard and German Standard Security

Front Access Short Front Access Stretch

290 mm (11.4 in.)

400 mm (15.8 in.)

330 mm (13 in.) 380 mm (15 in.) 430 mm (17 in.) 195 mm (7.7 in.) 195 mm (7.7 in.) 280 mm (11 in.)

290 mm (11.4 in.)

400 mm (15.8 in.) - original ducting 490 mm (19.3 in.) - modified ducting 400 mm (15.8 in.)

CEN

Front Access Short

290 mm (11.4 in.)

3-10

NCR Personas 77 ATM Site Preparation

Electrical Requirements Communications Requirements

Rear Access -

Dimensions apply to Standard, German Standard and CEN security enclosures. Dimensions B and C in previous illustration do not apply
Cable Alarm Interface Cable RS232 Remote Relay Dimension A 460 mm (18.1 in.) 380 mm (15.0 in.) 480 mm (18.9 in.)

Alarm Interface Cable (Front Access Stretch) - Preparation


The cable is prepared, depending on the version of ATM, as per the instructions detailed under Alarm Interface Cable (Front Access Short and Rear Access) - Preparation. Caution Do not prepare the Alarm Interface Cable, for the Front Access Stretch terminal, until you are sure which variant of cable ducting is fitted in the terminal. Check the variant by physically removing the cable ducting (refer to the Personas 77 ATM Installation Manual - B006-6209) and measuring the distance from the first earth stud to the front of the ducting:

Original cable ducting - earth studs towards the front of the ducting. Modified cable ducting - earth studs towards the back of the ducting.

NCR Personas 77 ATM Site Preparation

3-11

Electrical Requirements Communications Requirements

RS232 Cable

The ATM can have one RS232 outlet which can be configured for remote devices.

RS232 Cable -Specification


The cable is limited in length to 15.25 m (50 ft.) and must conform to the following specifications and wiring.
1, 2 6 5 3 4

1. Connector, 25 way (NCR part no. 006-0005897). 2. Terminal wire, male (NCR part no. 009-0002642). 3. Cable, multiconductor (NCR part no. 007-8907033). 4. Connector (determined by remote device). 5. Shell Hood (NCR part no. 006-1500038). 6. Screw retainer (NCR part no. 601-0101584). 1 2 3 8 5 4 6 20 7 CHASSIS GND TD RD RSLD CTS RTS DSR DTR SIGNAL GND 1 2 3 4 5 8 6 20 7 1 2 3 8 5 4 6 20 7 CHASSIS GND TD RD RTS CTS RSLD DSR DTR SIGNAL

Modemless Cable Adapter

RS232 Interface Cable

RS232 Cable -Preparation


The cable is prepared, depending on the version of ATM, as per the instructions detailed under Alarm Interface Cable (Front Access Short and rear Access) - Preparation.

3-12

NCR Personas 77 ATM Site Preparation

Electrical Requirements Communications Requirements

Remote Relay Cable

Remote Relay Cable -Specification


3

The remote relay provides a pair of open contacts, rated at 28 volts per ampere for both ac and dc supplies, which can be closed to activate a remote device. The interconnecting cable to a remote device must conform to the following specification and wiring:
1, 2 3 4

1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285). 2. Terminal wire, male (NCR part no. 007-2009663). 3. Cable, multiconductor (NCR part no. 006-5800006). 4. Connector (determined by remote device). 1 2 RL1 RL2

Remote Relay Cable Preparation


The cable is prepared, depending on the version of ATM, as per the instructions detailed under Alarm Interface Cable (Front Access Short and Rear Access) - Preparation.

NCR Personas 77 ATM Site Preparation

3-13

Electrical Requirements Communications Requirements

3-14

NCR Personas 77 ATM Site Preparation

Table of Contents Installation Site Environmental Requirements

Chapter 4

Installation Site Environmental Requirements


Environmental Requirements Temperature and Humidity Normal Operating Range (Interior ATM Environment) Normal Operating Range (Vestibule ATM Environment) All Environments Electromagnetic Compatibility (EMC) EMC Directives Harmonised EMC Standards Harmonised Safety Standard Barometric Pressure Heat Dissipation Air Flow Temperature Rise Acoustical Noise Weatherisation 4-1 4-1 4-1 4-1 4-2 4-2 4-2 4-2 4-3 4-3 4-3 4-3 4-3 4-3 4-3

NCR Personas 77 ATM Site Preparation

Table of Contents Installation Site Environmental Requirements

NCR Personas 77 ATM Site Preparation

Installation Site Environmental Requirements

Environmental Requirements

Environmental Requirements
For the ATM to function correctly, the installation site should meet the following environmental requirements. The ATM will operate over a range of temperature and humidity. However, continuous operation at or near the range limits or in a location where the temperature and humidity change beyond the specification, should be avoided. The temperature and humidity ranges are as follows:

Temperature and Humidity

Normal Operating Range (Interior ATM Environment)


Temperature: 10oC to 40oC (50oF to 104oF) Temperature change rate: 10oC (18oF) per hour Relative humidity: 20% to 80% Relative humidity change rate: 10% per hour Dew point temperature restriction: 26oC (79oF) maximum.
4

Normal Operating Range (Vestibule ATM Environment)


The ATM is designed to operate in an internal vestibule environment within the following limits: Interior to Wall: Temperature: 10oC to 40oC (50oF to 104oF) Temperature change rate: 10oC (18oF) per hour Relative humidity: 20% to 80% Relative humidity change rate: 10% per hour Dew point temperature restriction: 26oC (79oF) maximum.

NCR Personas 77 ATM Site Preparation

4-1

Installation Site Environmental Requirements Environmental Requirements

Exterior to Wall: Temperature: 0oC to 50oC (31oF to 122oF) Temperature change rate: 10oC (18oF) per hour Relative humidity: 20% to 80% Relative humidity change rate: 10% per hour Dew point temperature restriction: 26oC (79oF) maximum. The Personas 77 ATM meets the requirements of CES 2-11-01 for storage.
4

All Environments

The Personas 77 ATM meets the requirements of CES 2-11-01 for transit. Extreme power on range (up to one hour): Temperature: 0oC to 45oC (32oF to 113oF) Temperature change rate: 10oC per hour (18oF per hour) Relative humidity: 10% to 95%. The ATM complies with the following standards and directives:

Electromagnetic Compatibility (EMC)

EMC Directives
4

89/336/EEC EMC Directive 92/31/EEC Amending EMC Directive 73/23/EEC Low Voltage Directive 93/68/EEC CE Marking Directive.
4

Harmonised EMC Standards


Emission Standards

Radiated and Conducted: EN 55022 (latest version) Class A FCC CFR 47 Prt 15 Sub J Class A Conducted: EN61000-3-2 (latest revision) Mains Harmonics (Class A) EN61000-3-3 (latest revision) Mains Flicker.

4-2

NCR Personas 77 ATM Site Preparation

Installation Site Environmental Requirements Environmental Requirements

Immunity Standard

EN 55024 (latest version) ITE Immunity Standard.


4

Harmonised Safety Standard

EN60950 Safety of IT Equipment.

Barometric Pressure Heat Dissipation Air Flow Temperature Rise Acoustical Noise

The Personas 77 ATM meets the requirements of CES 2-11-01 Range 2 for storage. The heat dissipation of the ATM is 378kcal per h (1500Btu per h or 1606.5 kJ) maximum. The air flow through the ATM is rated at 0.1m3 per s (212ft3 per min.).

The temperature rise for air passing through the ATM is 3oC (5.4oF).
4

Does not exceed 65dBA in idle mode or 68dBA while operating.


4

Weatherisation

The ATM in its standard form is designed for interior use only. When fitted with any of the weatherisation features the ATM is specially adapted for the management of precipitation, but only for components contained within the fascia and cash exit. No other components or areas of the ATM are weather protected. The ATM must be installed such that the nonweatherised components are protected from precipitation.

NCR Personas 77 ATM Site Preparation

4-3

Installation Site Environmental Requirements Environmental Requirements

4-4

NCR Personas 77 ATM Site Preparation

Table of Contents Decals

Chapter 5

Decals
Decal Specifications Card Accept Card Orientation Decal Bar Code Reader Card Orientation Variant Bar Code Reader Positioning Label Advert Light Decal Exit/Entry Slot Decals Personas 77 Example Decals Recommended Icon, Text and Braille Placement 5-1 5-2 5-3 5-4 5-4 5-5 5-5 5-5 5-7

NCR Personas 77 ATM Site Preparation

Table of Contents Decals

NCR Personas 77 ATM Site Preparation

Decals

Decal Specifications

Decal Specifications
This following illustration shows the approximate locations for the decals which you may wish to fit to the front of your ATM.

Card Accept Window Receipt Card Insert Card Orientation Window

Cash

Specifications and guidelines for the various decals are given in the following sections.

NCR Personas 77 ATM Site Preparation

5-1

Decals Decal Specifications

Card Accept

The Card Accept decal, which is typically used to provide the consumer with information on card acceptance, surcharging or general advertising should conform to the following dimensions:
3 mm (0.12 in.) Radius on all corners

119 mm (4.7 in.)

90 mm (3.5 in.)

The insert should be a maximum of 0.8 mm (0.031 in.) thick. NCR recommend that the insert be made from one of the following materials:

Polycarbonate Polyester Paper.

5-2

NCR Personas 77 ATM Site Preparation

Decals Decal Specifications

Card Orientation Decal

If the Card Reader Module window is to be customised to indicate card orientation. The card/decal to be inserted should be a maximum of 0.75 mm (0.029 in.) thick and conform to the following dimensions:
3mm (0.12in.) radius on all corners

86mm (3.35in.)

54mm (2.12in.)

Note: These are the dimensions of the industry-standard credit card.

NCR Personas 77 ATM Site Preparation

5-3

Decals Decal Specifications

Bar Code Reader Card Orientation Variant


If a bar code reader is fitted to the ATM then the appropriate card orientation decal (NCR Part No. 509-0009135 or 509-0009136) can be fitted to the cowling with the following dimensions (graphics examples illustrated).

Label Size : 30.5 mm Wide x 33 mm High

Label Size : 30.5 mm Wide x 33 mm High

Bar Code Reader Positioning Label

If a bar code reader is fitted to the ATM then a bar code positioning decal (NCR part no. 509-0009138) must be fitted to the shelf with the following dimensions, if not factory fitted (graphics example illustrated).
4.0 mm radius on all corners

Label Size : 145 mm x 24 mm

Positioning of the label is achieved, primarily, with a location template (NCR part no. 509-0009238) or aligning with the bar code reader scan line.

5-4

NCR Personas 77 ATM Site Preparation

Decals Decal Specifications

Advert Light Decal

If an Advert Light decal is to be fitted, the decal should have the following dimensions: Front Access Lobby Variant - 396 mm (15.6 in.) wide x 100 mm (3.9 in.) high Rear Access Vestibule Variant - 510 mm (20.1 in.) wide x 120 mm (4.7 in.) high. Decals can be used to identify the exit/entry slots for the receipt printer, cash dispenser and card entry. The decal should be a maximum of 0.5 mm (0.02 in.) thick and it is recommended that it is made from Textured Polycarbonate with 3M 467 High Performance MP adhesive.

Exit/Entry Slot Decals

Note: A combination of your application and screen graphics can be used as an alternative to indicate the exit/entry slots.

Personas 77 Example Decals


The following decals are only a guide and financial institutions may wish to design their own.

NCR Personas 77 ATM Site Preparation

5-5

Decals Decal Specifications

Cash
12.5 mm (0.49 in.)

120 mm (4.72 in.)

55 mm (2.17 in.)

4 mm (0.16 in.)

Receipt
12.5 mm (0.49 in.)

95 mm (3.74 in.)

Card Insert
12.5 mm (0.49 in.)

86 mm (3.39 in.)

5-6

NCR Personas 77 ATM Site Preparation

Decals Decal Specifications

On the ATM, the MEIs are within the decal location recesses, this has to be considered when designing decals. The following are recommendations only:

if the background of the decal is transparent the decal can be the full depth 12.5 mm (0.49 in.) with/without a section (55 mm (2.17 in.) x 4 mm (0.16 in.) - the dotted area shown on the decals) cut out for the MEI. if a coloured background is required: the decal can be full depth 12.5 mm (0.49 in.) with a section (55 mm (2.17 in.) x 4 mm (0.16 in.) - the dotted area shown on the decals) cut out for the MEI. or

the decal can be 8 mm (0.32 in.) deep and be positioned along the top of the MEI.
5

Recommended Icon, Text and Braille Placement


10 mm (0.4 in.) 1.5mm (0.06 in.) 1.5mm (0.06 in.) 4mm (0.16 in.) to base line with 9mm (0.35 in.) to ascender 4.5mm (0.18 in.)
Icon

10mm (0.4 in.) braille registered right

10mm (0.4 in.)

NCR Personas 77 ATM Site Preparation

5-7

Decals Decal Specifications

5-8

NCR Personas 77 ATM Site Preparation

Table of Contents Transient Protection

Appendix A

Transient Protection
AC Power Line Transient Protection A-1

Data Line Transient Protection

A-3

NCR Personas 77 ATM Site Preparation

Table of Contents Transient Protection

NCR Personas 77 ATM Site Preparation

Transient Protection

AC Power Line Transient Protection

AC Power Line Transient Protection


In the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced on to power lines. Such transient energy can be very damaging to electronic hardware and can also cause data corruption. Under these circumstances, NCR recommends the use of a.c. power transient suppressors and data (communication) line transient suppressors. Such protective devices are intended to guard against power and data line transients that can result in hardware damage and various system or program errors.

Improvement of any deficiencies in power quality is a customer responsibility. Malfunction and/or component failure as a result of power quality problems are/is not covered by NCR Maintenance Agreement, NCR accepts no liability for any such occurrence nor for its consequences. When power transient suppression is required, the suppressors used should meet the following minimum requirements:

NCR Personas 77 ATM Site Preparation

A-1

Transient Protection AC Power Line Transient Protection

Dissipate energy to match the appropriate application categories as defined by IEEE Standard 587. These categories are described in the following table:
Comparabl e to IEC No 664 Category Transient

Location Category

Waveform

Amplitudes

A=Outlets > 10 m (30 ft) from Cat. B A= Outlets > 20 m (60 ft) from Cat. C B=Major feeders, short branch circuits, and load centres

II

0.5 s Risetime, then 100 kHz Ringwave, each peak=60% of previous Volts=1.3 x 5 s Current= 8 x 20 s and 0.5 s Rise = 100 kHz Ringwave Volts = 1.2 x 5 s Current = 8 x 20 s

6 kV 200A 6kV 3kA 6kV 500A 10kV or > 10kA or >

III

C = Service Entrance and run to load centre

IV

Be of the voltage limiting (clipping), or tracking filter type. The suppressor must not clamp the voltage to zero, and must self-recover after passage of the transient. The suppressor may be of the hybrid type construction that makes use of various technologies in order to meet speed and dissipation requirements Exhibit a short circuit mode upon its failure, thus providing a positive indication of its failure such as a blown fuse or tripped breaker Be listed by the accepted safety organization for the country involved (e.g. UL, CSA, VDE, ETL, etc.) and the installation must conform to local, state, and national electrical codes and regulations.

A-2

NCR Personas 77 ATM Site Preparation

Transient Protection Data Line Transient Protection

Data Line Transient Protection


The nature of the transient phenomenon may extend to the data communication lines connected to this equipment. It is the responsibility of the customer to install and connect a data line transient suppression system to correct or prevent any deficiencies. Such systems must meet the following minimum requirements:

Be of the voltage limiting type and must self-recover after passage of the transient Exhibit a short circuit mode upon its failure to insure a positive indication of its failure Insert less than 5 ohms resistance and minimal inductive and capacitive loading at the operating frequency, in each data line in order to avoid signal degradation Be installed in accordance with all applicable local, state, and national electrical codes and regulations.

Note: In certain countries, NCR is able to supply both power and data line transient suppressors as well as a comprehensive line of power conditioning equipment. For application data, contact your NCR Customer Services Division Representative.

NCR Personas 77 ATM Site Preparation

A-3

Transient Protection Data Line Transient Protection

A-4

NCR Personas 77 ATM Site Preparation

Table of Contents Power Protection

Appendix B

Power Protection
NCR Power Protection and Cabling Products AC Power Line Transient Protection Data Line Transient Protection Uninterruptible Power Supplies On-line UPS Enhanced Line-Interactive UPS Line-Interactive UPS Contact Information B-1 B-1 B-2 B-2 B-2 B-3 B-4 B-4

NCR Personas 77 ATM Site Preparation

Table of Contents Power Protection

NCR Personas 77 ATM Site Preparation

Power Protection

NCR Power Protection and Cabling Products

NCR Power Protection and Cabling Products


Power protection equipment suitable for use with NCR ATMs can be purchased from the NCR Power Protection and Cabling group. Some of these products are outlined below. The following products can be purchased from the NCR Power Protection and Cabling group to help provide protection from power line spikes and surges:
NCR Product ID Description

AC Power Line Transient Protection

4060-4030-0094 4060-4050-0094 4060-4070-0094 4060-4310-7594 4060-4311-7594 4060-4312-7594

110V, 3 outlet, wall plug-in, 15 Amp suppressor, United States applications 110V, 3 outlet, strip, 15 Amp suppressor with 1.8 metres (6 feet) of power cable, United States applications 110V, 7 outlet, strip, 15 Amp suppressor with 1.8 metres (6 feet) of power cable, United States applications 220V, 4 outlet, strip, United Kingdom plug fitted 220V, 4 outlet, strip, German/European plug fitted 220V, 4 outlet, strip, French plug fitted

These products have numerous features:


unique five-stage hybrid circuitry protection from spikes and surges protection covers all modes - line to neutral, line to earth (ground) and neutral to earth (ground) integral RF/EMI damping capability thermal overload protection high capacity fusing indicator lights display operational readiness highly flame retardant plastic housing, conforming to UL94-5V.

NCR Personas 77 ATM Site Preparation

B-1

Power Protection NCR Power Protection and Cabling Products

Data Line Transient Protection

The following Data Line Transient Voltage Surge Suppressors can be purchased from the NCR Power Protection and Cabling group to help protect the communications port against harmful transient surges from both external and internal sources not eliminated by Uninterruptible Power Supplies (UPS) or other AC protection:
NCR Product ID Description

4060-K018-V000 4060-K019-V000 4060-K021-V000 4060-K022-V000

25 pin, CMP, snaps in to United States surge suppressors 25 pin, CFP, snaps in to United States surge suppressors 25 pin, CMP, stand-alone, all applications 25 pin, CFP, stand-alone, all applications

Note: The first two products are designed to snap-in to the interface port on NCR Series 4000 Transient Voltage Surge Suppressors in the United States. The second two products are designed to be stand-alone for use in Europe. Uninterruptible Power Supplies (UPS) can be purchased from the NCR Power Protection and Cabling group to help protect information and equipment by providing power conditioning and battery back-up.

Uninterruptible Power Supplies

On-line UPS
NCR Product ID Description

4082-1000-7194 4082-1000-7494

1000 VA on-line UPS with rack/tower configuration, 120VAC 50/60 Hz 1000 VA on-line UPS with rack/tower configuration, 230VAC 50/60 Hz

These products offer:


on-line topology 10 minute battery backup at full load true sine wave output 100% clean, conditioned power to connected equipment extended battery cabinets available for extended run times

B-2

NCR Personas 77 ATM Site Preparation

Power Protection NCR Power Protection and Cabling Products


on-board SNMP optional on all models standard LAN/serial (RS-232) network interface standard rack-mountable unit design also available in 1500 VA, 2000 VA and 3000 VA sizes.
B

Enhanced Line-Interactive UPS


NCR Product ID Description

4071-1020-7194 4071-1021-7194 4071-1020-7494 4071-1021-7494

1000 VA Enhanced line-interactive UPS, 120VAC 60Hz 1000 VA Enhanced line-interactive UPS, 120VAC 60Hz Rack-mountable 1000 VA Enhanced line-interactive UPS, 230 VAC, 50/60 Hz 1000 V A Enhanced line-interactive UPS, 230 VAC, 50/60 Hz, Rack-mountable

These products offer:


line-interactive topology 8 minute battery backup at full load true sine wave output input voltage selectable to 110/127 VAC or 220/240 VAC advanced battery management prolongs battery life and ensures quick availability after discharge advanced battery management for early failure detection and advanced user warning internal transformer provides voltage buck/boost standard LAN/serial (RS-232) network interface rack-mountable configuration available in 600 VA, 1500 VA, 2000 VA, 2200 VA, 2400 VA and 3000 VA sizes.

NCR Personas 77 ATM Site Preparation

B-3

Power Protection NCR Power Protection and Cabling Products

Line-Interactive UPS
NCR Product ID 4070-1000-7194 4070-1000-7494 Description 1000 VA Line-interactive UPS, 120AC, 60 Hz 1000 VA Line-interactive UPS, 230VAC, 50/60 Hz

These products offer:


line-interactive topology 7 minute battery backup at full load modified sine wave output input voltage selectable at 110/127 VAC or 220/240 VAC advanced battery management prolongs battery life and ensures quick availability after discharge advanced battery management for early failure detection and advanced user warning internal transformer provides voltage buck/boost standard LAN/serial (RS-232) network interface hot-swappable batteries available in 450 VA, 700 VA, 1500 VA sizes.

Contact Information

For more information from NCRs Power Protection and Cabling Group on the power protection, data line transient suppressors and uninterruptible power supply products available, warranty or configuration assistance, call the appropriate number below:
Telephone

Worldwide (excluding the USA) USA only

(44) 1932 57 3435 or + 1 919 460 9489 1 800 257 0458


Facsimile

Worldwide

USA +1 919 460 9558

B-4

NCR Personas 77 ATM Site Preparation

Index

Index
A
AC Current Requirements 3-1 AC Power Line Transient Protection A-1, B-1 Access For All Heights to Main Facia Items 2-58 Access for All 2-58 Recommended Wheelchair Clearance 2-61 Advert Light Package 2-7 Alarm Interface Cable 3-7 Preparation F/A Short 3-10 F/A Stretch 3-11 Specifications 3-8 Wiring 3-9 ATM Dimensions 2-8 Positioning 2-55 Variants viii Barcode Reader Safety Information ix Cables Alarm Interface 3-7 High Order Communications 3-4 HOCs Ethernet Cable 3-7 HOCs Standard Cable (RS-232) 3-5 Remote Relay Cable 3-13 RS232 Cable 3-12 Clearances Installation and Service 2-20 Communication Cables Preparation 3-6 Routing 3-4 Communications Requirements 3-4 Customer Responsibilities 2-2

B C

NCR Personas 77 ATM Site Preparation

Index-1

Index

Data Line Transient Protection A-3, B-2 Decal Specifications 5-1 Card Accept 5-2 Card Orientation Decal 5-3 Exit/Entry Slots 5-5 Decals Examples 5-5 Icon, Text and Braille Placement 5-7 Electrical Requirements 3-1 Communications Requirements 3-4 Power Distribution And Grounding 3-1 Electromagnetic Compatibility EMC Directives 4-2 Harmonised EMC Standards 4-2 Harmonised Safety Standard 4-3 EMI Emission 3-3 Susceptibility 3-3 Environmental Requirements 4-1 Acoustical Noise 4-3 Air Flow 4-3 All Environments 4-2 Barometric Pressure 4-3 Electromagnetic Compatibility 4-2 Heat Dissipation 4-3 Temperature And Humidity 4-1 Temperature Rise 4-3 Floor Covering 2-55 Floor Loading 2-56 Grounding Requirements 3-3 Heights to Main Facia Items 2-58 HOCs Ethernet Cable Preparation 3-7 Specification and Wiring 3-7 HOCs Standard Cable (RS-232) Preparation 3-6 Specification 3-5 Wiring 3-5 Humidity 4-1

F G H

Index-2

NCR Personas 77 ATM Site Preparation

Index

Input Voltage Setting 3-1 Installation Accessories 1-2 Installation And Service Clearances Recommended Floor Area 2-25 Installation and Service Clearances 2-20 Minimum Floor Area 2-21 Lighting Ambient Lighting for Video Camera 2-55 Location Points Securing Bolts 2-41, 2-49 Noise Generation 4-3 Normal Operating Range Interior ATM Environment 4-1 Note 2-9 Packaging Dimensions 2-4 Front Access Short, BH, German and CEN 2-4 Front Access Stretch and Rear Access 2-5 Vestibule 2-6 Physical Requirements Access for All 2-58 ATM Dimensions 2-8 Customer Responsibilities 2-2 Installation and Service Clearances 2-20 Overview 2-1 Packaging Dimensions 2-4 Product Information 2-3 Planning Check List 1-1 Positioning the ATM 2-55 Power Cable 3-1 Power Protection And Cabling Products B-1 AC Power Line Transient Protection B-1 Contact Information B-4 Data Line Transient Protection B-2 Uninterruptible Power Supplies B-2

NCR Personas 77 ATM Site Preparation

Index-3

Index

Power Quality Distribution And Grounding Requirements AC Current Requirements 3-1 EMI Emission 3-3 EMI Susceptibility 3-3 Input Voltage Setting 3-1 Power Cable 3-1 Transient Power Loss 3-3 Preparation Ethernet Cable 3-63-7 Standard Cable (RS232) 3-6 Product Class Type 2-3 Information 2-3 Recommended Wheelchair Clearance 2-61 Remote Relay Cable 3-13 Preparation 3-13 Specification 3-13 RS232 Cable 3-12 Preparation 3-12 Specification 3-12 Safety Information ix Barcode Reader ix Securing Bolt Location Points 2-41, 2-49 Front Access Business Hours 2-42 Front Access German 2-46 Front Access Short 2-41 Front Access Stretch 2-43 Rear Access CEN 2-47 Rear Access Standard 2-45 Vestibule CEN 2-51 Vestibule German 2-50 Vestibule Standard 2-49 Securing Bolts Specifications 2-54 Security Requirements 2-54

Index-4

NCR Personas 77 ATM Site Preparation

Index

Temperature And Humidity 4-1 Terminal Dimensions CEN Security 2-11 Front Access Short and Business Hours, Minimum 2-21 Front Access Short and Business Hours, Recommended 2-22 Front Access Stretch 2-10 Front Access Stretch and German, Minimum 2-23 Front Access Stretch and German, Recommended 2-24 Rear Access, German Standard Security 2-12 Rear Access, Lobby 2-12 Rear Access, Standard Security 2-12 Short with Business Hours Security 2-9 Short with German Standard Security 2-9 Short with Standard Security 2-9 Stretch with Standard Security 2-10 Vestibule Terminals 2-14 Terminals Dimensions Rear Access, CEN 3 Standard 2-13 Transient Power Loss 3-3 Transient Protection AC Power Line A-1 Data Line A-3 UL291 Security Requirements viii Uninterruptible Power Supplies B-2 Enhanced Line-Interactive B-3 Line-Interactive B-4 On-line B-2 Variants of ATM viii Video Camera Lighting 2-55 Weight 2-56

NCR Personas 77 ATM Site Preparation

Index-5

Index

Index-6

NCR Personas 77 ATM Site Preparation

User Feedback Form

Title: Number:
Cut

NCR Personas 77 ATM Site Preparation B006-6208-H000 Date: January 2012

NCR welcomes your feedback on this publication. Your comments can be of great value in helping us improve our information products. You may send your comments, electronically, to the Information Solutions Department at Dundee. See over for details. Circle the numbers below that best represent your opinion of this publication. Ease of use Accuracy Clarity Completeness Organization Appearance Examples Illustrations Job performance Question resolution Overall satisfaction 5 5 5 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4 4 4 4 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 5 = Excellent 4 = Good 3 = Adequate 2 = Fair 1 = Poor 0 = Not Applicable

Indicate the ways you feel we could improve this publication.

Improve the overview/introduction Improve the organization Improve the index Make it less technical Make it more concise/brief

Add more/better quick reference aids


Add more examples Add more illustrations Add more step-by-step procedures Add more troubleshooting information Add more detail

Write any additional comments you may have below and on additional sheets, if necessary. Include page numbers where applicable.

If we may contact you concerning your comments, please fill in the information below: Name Organisation: Company: Address: Phone: Fax:

Thank you for your evaluation of this publication. Fold the form where indicated, tape (please do not staple), affix stamp and drop in the mail.
F8763-0695 Fold

Affix Postage Stamp Here

NCR Financial Solutions Group Ltd.


Information Solutions Kingsway West Dundee Scotland DD2 3XX

Cut

Use the following address to send your comments, electronically, to the Information Solutions Department at Dundee: e-mail - userfeedback@ncr.com

B006-6208-G000