You are on page 1of 8

Bibliografie

[1] [2] [3] Selincourt A (ed): Herodotus, the Histories. New York, Penguin Books, 1954. Fletcher MJ: Problems in designing of artificial hands. Orthop Prosthet Appliance J 1955; 9:59-68. DeFries MG: Sizing of Cosmetic Hands to Fit the Child and Adult Population. Washington, DC, U.S. Army Medical Biomechanical Research Laboratory, Walter Reed Army Medical Center, Technical Report No. 5441, 1954. Carnelli WA, DeFries MG, Leonard J: Color realism in the cosmetic glove. Artif Limbs 1955; 2:57-65 Motis GM: Final Report on Artificial Arm and Leg Research and Development. Final Report to the National Research Council, Advisory Committee on Artificial Limbs, Hawthorne, Calif, Northrop Aircraft Inc, 1951. Borchardt M, et al (eds): Ersatzglieder und Arbeitshilfen. Berlin, Springer-Verlag, 1919. Alderson SW: The electric arm, in Klopsteg PE, Wilson PD: Human Limbs and Their Substitutes. New York, McGraw-Hill International Book Co, 1954. Reprinted by Hafner Press, New York, 1960. Kobrinski AE, Bolhovitin SV, Voskoboinikova LM, et al: Problems of bioelectric control in automatic and remote control, in Proceedings of the First International Congress of the International Federation of Automatic Control, Moscow, 1960, vol 2. Butterworth, London, 1960. Rakic M: Practical design of a hand prosthesis with sensory elements. Presented at the International Symposium of the Application of Automatic Control in Prosthetics Design, Belgrade, Yugoslavia, Aug 27-31, 1962. Kessler HH, Kiessling EA: Pneumatic arm prosthesis. Am J Nurs 1965; 65:114-117. Almstrm C, Herberts P, Korner L. Experience with Swedish multifunctional prosthetic hands controlled by pattern recognition of multiple myoelectric signals. Int Orthop 1981;5(1): 1521. Bergman K, rnholmer L, Zackrisson K, Thyberg M. Functional benefit of an adaptive myoelectric prosthetic hand compared to a conventional myoelectric hand. Prosthet Orthot Int 1992;16: 3237. Gow DJ, Dick TD, Draper ERC, et al. The physiologically appropriate control of an electrically powered hand prosthesis. Presented at: International Society of Prosthetics and Orthotics 4th World Congress; September 1983; London, United Kingdom. Miller LA, Lipschutz RD, Weir RW, et al. Shoulder disarticulation fitting with six independently controlled motors after targeted hyper-reinnervation nerve transfer surgery. Presented at: Myoelectric Controls Symposium; August 2527, 2005; Fredericton, New Brunswick, Canada. Jones B, Kyberd PJ. Improved control for an artificial arm. Presented at: Myoelectric Controls Symposium; August 2527, 2005; Fredericton, New Brunswick, Canada, pp. 4348. Kyberd PJ. The Algorithmic Control of a Multifunction Hand Prosthesis [PhD thesis]. Southampton University, United Kingdom; Electrical Engineering Department, 1990 Kyberd PJ, Beard DJ, Morrison JD. The population of users of upper limb prostheses in Oxfordshire. Prosthet Orthot Int 1997; 21(2):8591. Baits JC, Todd RW, Nightingale JM. The feasibility of an adaptive control scheme for artificial prehension. Proceedings of a Symposium at the Institute of Mechanical Engineering, 1968;183: 5459.

[4] [5]

[6] [7]

[8]

[9]

[10] [11]

[12]

[13]

[14]

[15]

[16] [17] [18]

233

Bibliografie [19] [20] Nightingale JM. Microprocessor control of an artificial arm. J Microcomput Appl 1985;8:167173. Simpson DC: Powered upper arm prostheses for young children (digest). Presented at the Sixth International Conference on Medical Electronics and Biological Engineering, Tokyo, Biddiss EA, Chau TT. Multivariate prediction of upper limb prosthesis acceptance or rejection. Disabil Rehabil Assist Technol. Feb 10 2008;1-12 Fryer CM, Stark GE, Michael JW. Body powered components. In: Smith DG, Michael JW, Bowker JH, ed. Atlas of Amputations and Limb Deficiencies. 3rd ed. Rosemont, Ill: Am Acad Orthop Surg; 2004:117-30. Fryer CM, Michael JW. Harnessing and controls for body-powered devices. In: Smith DG, Michael JW, Bowker JH, eds. Atlas of Amputations and Limb Deficiencies. 3rd ed. Rosemont, Ill: Am Acad Orthop Surg; 2004:131-44. V. O. Del Cura, F. L. Cunha, M. L. Aguiar and A. Cliquet, Jr, Study of the Different Types of Actuators and Mechanisms for Upper Limb Prostheses, Journal of Artificial Organs, vol. 27, no. 6 pp. 507-516, 2003 Gh. Lazea, R. Robotin, S. Herle, C. Marcu, Echipamente de automatizare pneumatice i hidraulice, vol. 1 Echipamente pneumatice, Editura U.T Press, Cluj Napoca, 2006 http://eecs.vanderbilt.edu/cis/crl/isac.shtml http://mech-eng.curtin.edu.au/staff/lindsay/teaching_interests/pneumatichand/ Esquenazi A, Leonard JA Jr, Meier RH 3rd, et al. Prosthetics, orthotics, and assistive devices. 3. Prosthetics. Arch Phys Med Rehabil. May 1989;70(5-S):S206-9. Kyberd, Peter J. PhD; Wartenberg, Constanze PhD; Sandsj, Leif PhD; Jnsson, Stewe CPO; Gow, David BSc; Frid, Joakim MSc; Almstrm, Christian PhD; Sperling, Lena PhD, JPO Journal of Prosthetics & Orthotics: April 2007 - Volume 19 - Issue 2 pp 55-62 http://www.darpa.mil/index.html http://www.ottobock.com/cps/rde/xchg/ob_com_en/hs.xsl/32040.html http://www.ehow.com/info_8614833_financial-amputees.html
W. Maurel and D. Thalmann, Human shoulder modeling including scapulo-thoracic constraint and joint sinus cones , http://ligwww.epfl.ch/~maurel/Publish/CG2K/CG2K.pdf

[21] [22]

[23]

[24]

[25]

[26] [27] [28] [29]

[30] [31] [32] [33] [34]

Yongchul Kim, Chulhue Park, Youngil Youm, Sungchul Choi , Sungjun Han, Hanil Bae, Biomechanical model of human-like arm for a crash test, 2003 Summer Bioengineering Conference, June 25-29, Sonesta Beach Resort in Key Biscayne, Florida H. Shin Norman I. Badler, Modeling Deformable Human Arm for Constrained Research Analysis, Proceedings of the Digital Human Modeling Conference, June 2002, pages 217-228. Marjan A. Admiraal, Martijn J.M.A.M. Kusters, and Stan C.A.M. Gielen, Modeling Kinematics and Dynamics of Human Arm Movements , Motor Control, 2004, 8, 312338 S. Herle et al., Simulation-Based Stress Analysis for a 3D Modeled HumerusProsthesis Assembly, Innovations in Computing Sciences and Software Engineering, Editors Sobh Tareh, Elleithy Khaled, ISBN 978-90-481-9111-6, Springer, pp.343-348, 2010 G. Mansour, S. Mitsi, K. Bouzakis, A kinematic and dynamic model of the human upper extremity, Proceedings of the 3rd International conference on Manufacturing Engineering, Chalkidiki, Greece, 1-3 October 2008 S. Herle, Model bra umanoid, Refererat de doctorat nr. 2, UTCN, 2005 http://biomech.ftvs.cuni.cz/pbpk/kompendium/biomechanika/geometrie_hmotnost_

[35]

[36]

[37]

[38]

[39] [40]

234

Bibliografie en.php [41] [42] D.A. Winter, Biomechanics and Motor Control of Human Movement, Third Edition, John Wiley & Sons Inc., Hoboken, New Jersey, 2005. Z. Ping, M.M. Lowery, J.P.A Dewald, T.A. Kuiken, Towards Improved Myoelectric Prosthesis Control: High Density Surface EMG Recording After Targeted Muscle Reinnervation, 27th Annual International Conference of the Engineering in Medicine and Biology Society, pp. 4064-4067, ISBN: 0-7803-8741-4, Shanghai, January 2006. C.M. Light, P.H. Chappels s.a. Intelligent multifunction myoelectric control of hand prosthesis Journal of Medical Engineering and Technology, Vol.26, No. 4, (Julie 2002) pp. 139-146, ISSN: 0309-1902 A.D.C. Chan si K.B. Englehart, Continuous myoelectric control for powered prostheses using hidden Markov models, IEEE Transaction on Biomedical Engineering, Vol. 52, No. 1, (January 2005), page numbers (121 - 124), ISSN: 0018929 H. Hermens, B. Freriks, R. Merletti, D. Stegeman, J. Blok, G. Rau, C. DisselhorstKlug, and G. Hagg, European recommendations for surface electromyography, Roessingh Research and Development, Enschede, Netherlands, 1999. http://www.delsys.com/Products/EMGSensors.html K. Englehart, B.Hudgins, P.A. Parker, A wavelet-based continuous classification scheme for multifunction myoelectric control, IEEE Trans. Biomed. Eng. Vol. 48, No. 3 (2001) pp. 302-310 K. Englehart, B.Hudgins, A robust real-time control scheme for multifunction control, IEEE Trans. Biomed. Eng. Vol. 50, No. 7 (2003) pp. 848-854 D.Farina, R. Merletti, Comparision of alghorithms for estimation of EMG variables during voluntary isometric contractions, J. Electromyography and Kinesiology, Vol. 10, (2000), pp. 337-349. M. Zecca, S. Micera, M.C. Carrozza, P.Dario, Control of multifunctional prosthetic hands by processing the electromyographic signal, in: Critical Reviews in Biomedical Engineering, Begell House, (2002), pp. 459-485. A. Merlo, D. Farina, R. Merletti, A fast and reliable technique for muscle activity detection from surface EMG signals, IEEE Transaction Biomedical Engineering, Vol. 50, No. 3 (2003), pp. 316-323. M.A. Oskoei, H. Hu, Myoelectric control systems-A survey, Journal of Bioemedical Signal Porcessing and Control, Vol. 2 (2007), pp. 275-294 E.A.Clancy, E.L.Morin, R. Merletti, Sampling, noise-reduction and amplitude estimation issues in surface electromyography, Journal of Electromyography and Kinesiology, Vol. 12 (2002) pag. 1-16. B. Hudgins, P. Parker, R. Scott, A new strategy for multifunction myoelectric control, IEEE Transaction Biomedical Engineering , Vol. 40, No. 1 (1993), pp. 8294. S. Karlsson, J.Yu, M. Akay, Enhancement of spectral analysis of myoelectric signals during static contractions using wavelet methods, IEEE Transaction Biomedical Engineering, Vol. 46, No. 6, (1999), pp. 670-684. D. Farina, R. Merletti, Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions, Journal of Electromyography and Kinesiology, Vol. 10 (2000) pp. 337-349. K. Englehart, B. Hudgins, P. Parker, M. Stevenson, Classification of the myoelectric signal using time-frequency based representations, Medical Engineering Physiology, Vol. 21, (1999), pp. 431-438 M.A. Oskoei, H. Hu, GA-based feature subset selection for myoelectric

[43]

[44]

[45]

[46] [47]

[48] [49]

[50]

[51]

[52] [53]

[54]

[55]

[56]

[57]

[58]

___________________________________________________________________________ 235

Bibliografie classification, Proceedings of the International Conference on Robotics and Biomimetics, China, (December 2006), pp. 1465-1470. [59] S. Du, M. Vuskovic, Temporal vs. spectral approach to feature extraction from prehensile EMG signals, Proceedings of the IEEE International Conference on Information Reuse and Integration, Las Vegas, (November 2004), pp. 344350 M. Akay, Detection and Estimation Methods for Biomedical Signals, Academic Press, Inc., ISBN: 0120471434, Orlando, FL, USA, (1996). A. Soares, A. Andrade, E. Lamounier, R. Carrijo, The Development of a Virtual Myoelectric Prosthesis Controlled by an EMG Pattern Recognition System Based on Neural Networks, Journal of Intelligent Information Systems, Vol. 21, No. 2, (September 2003) pp. 127-141. E. Lamounier, A. Soares, A. Andrade, R. Carrijo, A virtual prosthesis control based on neural networks for EMG pattern classification, Proceedings of the Artificial Intelligence and Soft Computing, Canada, (2002). S. Man and S. Herle, Classication of electromyographic signals using autoregressive modeling and neural networks, in Proceedings of Automation and Computer Science Students Conference, Cluj Napoca, 2009 S. Man, S. Herle, G. Lazea, D. Bordencea, I. Muntean, and B. Muresan, The use of neural networks in the classication of the electromyographical signals, in Proceedings of the 9th national conference Profesor Dorin Pavel, (Sebes), 2009 A.B., Ajiboye, R.F., Weir, A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control, IEEE Transaction on Neural System Rehabilitation Engineering, Vol. 13, No. 3, (2005), pp. 280-291. B. Karlik, M.O., Tokhi, M. Alci, A fuzzy clustering neural network architecture for multifunction upper-limb prosthesis, IEEE Transaction on Biomedical Engineering, Vol.50, No. 11, (2003), pp.1255-1261. Y. Huang, K. Engelhart, B. Hudgins, A.D.C, Chan, A Gaussian mixture model based classification scheme for myoelectric control of powered upper limb prosthesis, IEEE Transaction on Biomedical Engi-neering, Vol. 52, No.11, (2005), pp.1801-1811. B. Hudgins, P. Parker, R. Scott, Control of artificial limbs using myoelectric pattern recognition, Medical Life Science Engineering, Vol. 13, (1994), pp. 21-38. J. Zhao, Z. Xie, L. Jiang, H. Cai, H. Lio, G. Hirzinger, EMG control for a five-fingered interactuated prosthetic hand based on wavelet transform and sample entropy, Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems, China, (October 2006), pp. 3215-3220. N. Chaiyaratanal, A.M.S. Zalzala, D. Datta, Myoelectric signals pattern recognition for intelligent functional operation of upper-limb prosthesis, Proceedings of the First Euro Conference Disability, Virtual Reality and Associated Technology, Maidenhead, UK, (1996), pp 151-160. A.B. Ajiboye, R.F. Weir, A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control, IEEE Transaction Neural System Rehabilitation Engineering, Vol. 13, No. 3, (2005) pp.280-291 S.H. Park, S.P. Lee, EMG pattern recognition based on artificial intelligence techniques, IEEE Transaction on Rehabilitation Engineering, Vol. 6, No. 4, (1998), pp. 400-405. K. Kiguchi, T. Tanaka, K. Watanabe, T. Fukuda, Design and control of an exoskeleton system for human upper-limb motion assist, Proceedings of IEEE/ASME International Conference on Advanced Intelligent Mechatronics (2003), pp. 926-931 K. Kiguchi, R. Esaki, T. Tsuruta, K. Watanabe, T. Fukuda, An exoskeleton system for elbow joint motion rehabilitation, Proceedings of IEEE/ASME International Conference on Advanced Intelligent Mechatronics (2003), pp. 1228-1233 M. Vuskovic, S.J.Du, Classification of prehensile EMG patterns with simplified fuzzy

[60] [61]

[62]

[63]

[64]

[65]

[66]

[67]

[68] [69]

[70]

[71]

[72]

[73]

[74]

[75]

236

Bibliografie ARTMAP networks, Proceedings of the International Joint Conference on Neural Networks, Vol. 3, (2002), pp. 2539-2544. [76] F.H.Y. Chan, Y.S. Yang, F.K. Lam, Y.T. Zhang, P.A.Parker, Fuzzy EMG classification for prosthesis control, IEEE Transaction on Rehabilitation Engineering, Vol. 8, No. 3, (2000), pp. 305-311. J.S.Han, Z.Z. Bien, D.J.Kim, H.E. Lee, J.S.Kim, Human-machine interface for wheelchair control with EMG and its evaluation, Proceedings of the 25th IEEE International Conference on Engineering in Medicine and Biology Society, Cancun, Mexico, (September 2003), pp. 1602-1605 S. Herle, P. Raica, Gh.Lazea, R. Robotin, C.Marcu, L. Tamas, Classification of surface electromyographic signals for control of upper limb virtual prosthesis using time-domain features, Proceedings of 2008 IEEE International Conference on Automation, Quality and Testing, Robotics, Cluj-Napoca, Romania, May 2008, pp.160-165 A. Subasi, M. Yilmaz, H.R., Ozcalik, Classification of EMG signals using wavelet neural network, Journal of Neuroscience Methods, No. 156, 2006, pp. 360-367 S. Micera, A. M., Sabatini, P. Dario, On automatic identification of upper-limb movements using small-sized training sets of EMG signals, Journal of Medical Engineering and Physics, No.22, 2000, pp. 527-533. S. Man, S. Herle, Gh. Lazea, Classification of electromyographic signals using autoregresive modeling, Proceedings of the 20th International DAAAM Symposium, Vol. 20, No.1, Vienna, Austria (2009), pp. 1049-1050 S. Herle, S. Man, Gh.Lazea, R. Robotin, C.Marcu, Myoelectrical signal classification for the hierarchical control of a human hand prosthesis, Proceedings of 2010 IEEE International Conference on Automation, Quality and Testing, Robotics, ClujNapoca, Romania, May 2010, Tome II, pp.288-293 S.Herle, S. Man, Processing surface electromyographical signals for myoelectric control, Rehabilitation engineering, Editor Yen Kheng Tan, chapter 14, In-tech, december 2009, ISBN 978-953-307-023-0. V.M. Hernandez-Guzman, V. Santibanez and R. Campa, PID control of robot manipulators equipped with brushless DC motors, Robotica, vol. 27, pp. 225-233, 2009 V.M. Hernandez-Guzman, V. Santibanez and A. Zavala-Rioss, A saturated PD controller for robots equipped with brushless DC-motors, Robotica, vol. 28, pp. 405-411, 2010 D. Batra, S. Sharma and R. Ratan, Axis controlled movement of robot using brushless DC motor drive, Indian Journal of Science and Technology, vol 2. No 4, 2009. M. unkas and O. Aydodu, Realization of fuzzy logic controlled brushless DC Motor drives using matlab/simulink, Journal of Mathematical and Computational Applications, Vol. 15, No.2, pp. 218-229, 2010 B. G. Lau, An intelligent prosthetic hand using hybrid actuation and myoelectric control, PhD Thesis, The University of Leeds, October 2009 V. Artigue, G. Thomann, Development of a prosthetic arm: experimental validation with the user and an adapted software, IEEE International Conference on Robotic and Automation, ICRA09, Kobe, Japan, 12-17 May 2009, pp. 3079-3084 F. Casolo, S. Cinquemani, M. Cocetta, Functional design of a transmission for a myoelectric elbow prosthesis, Proceedings of the World Congress on Engineering, WCE2008, Vol 3, July 2-4, 2008, London UK. C. Marcu, Gh. Lazea, R. Robotin, S. Herle, and L. Tamas, Industrial robot controller using miniature computers. IEEE International Conference on Automation, Quality and Testing, Robotics, AQTR 2008 , May 2008.

[77]

[78]

[79] [80]

[81]

[82]

[83]

[84]

[85]

[86]

[87]

[88] [89]

[90]

[91]

___________________________________________________________________________ 237

Bibliografie [92] S. Herle, S. Man, Gh.Lazea, C.Marcu, R. Robotin, Exploiting parallel processing and optimal paths in a flexible manufacturing system Proceedings of 2010 IEEE International Conference on Automation, Quality and Testing, Robotics, ClujNapoca, Romania, May 2010, Tome III, pp.23-28 S. Herle, S. Man, Gh.Lazea, Multitasking programming in flexible manufacturing systems, The 20th INTERNATIONAL DAAAM SYMPOSIUM, "Intelligent Manufacturing & Automation: Theory, Practice & Education", 25-28th November 2009, Vienna, Austria S. Herle, Gh. Lazea, R. Robotin, Sisteme de fabricaie integrat, Editura Mediamira, Cluj-Napoca, 2004 M. Rehan Ahmed, Compliance Control of Robot Manipulator for safe physical human robot interaction, Intellecta Infolog, Kallered, 2011, ISBN 978-91-7668-776-5 A. Roy and K. Iqbal, PID stabilization of a position-controlled robot manipulator acting independently or in a collaboration with human arm, Journal of the Arkansas Academy of Science, Vol. 57, 2003. Gh. Lazea, R. Robotin, S. Herle, C. Marcu, L. Tamas Mobile robots formation navigation with behavior based algorithms, IEEE International Conference on Automation, Quality and Testing, Robotics, 2008. AQTR 2008. Volume 3, 22-25 May 2008, Cluj-Napoca, Romania. L. Tamas, Gh. Lazea, R. Robotin, C. Marcu, S. Herle, Z. Szekely State Estimation Based on Kalman Filtering Techniques in Navigation; IEEE International Conference on Automation, Quality and Testing, Robotics, 2008. AQTR 2008. Volume 3, 22-25 May 2008, Cluj-Napoca, Romania Gh. Lazea, R. Robotin, S. Herle, C. Marcu, L. Tamas, - Obstacle detection and map-building using artificial vision for mobile robots navigation, 9th International Carpathian Conference, 25-28 May, 2008, Sinaia Romania (ISBN 987.973.746.897.0) Gh. Lazea, R. Robotin, S. Herle, F. Cotofan Mobile robot navigation in dynamic environments using path planning algorithms with focusing heuristic., Annals of the University of Craiova series Automation,Computers, Electronics and Mechatronics. Vol.3(30), no.1, 2006, pp.55-59, ISSN 1841-0626 Gh. Lazea, R. Robotin, S. Herle, F. Cotofan - Mobile Robot Navigation In Dynamic Environments Using Path Planning Algorithms With Focusing Heuristic, Proceedings of SINTES 12, vol.2,pag.292, oct.2005, Craiova R. Robotin, Gh. Lazea , S. Herle Hybrid Goal Aquisition System For Pioneer 2 Mobile Robot, Journal of Control Engineering and Applied Informatics.Vol.6,nr.2, 2004,pag.51. ISSN 1454-8658 R. Robotin, Gh. Lazea, S. Herle Hybrid goal acquisition system for pioneer 2 mobile robot, AQTR 2004 (THETA 14), IEEE-TTTC - International Conference on Automation, Quality and Testing, Robotics, May 13 15, 2004, Cluj-Napoca, Romania R. Robotin, Gh. Lazea, S. Herle Potential field navigation system for pioneer 2 mobile robot, 14th International DAAAM Symposium, 23-25th October 2003, pp 451-452, Wien, Austria R. Robotin, Gh. Lazea, S. Herle Navigation algorithm for Pioneer 2 mobile robot hybrid potential field method, 14th Int. Conf. CSCS- 2003, Bucuresti, pag 205; R. Robotin, Gh. Lazea, S. Herle Potential Field Navigation Algorithm for Pioneer 2 Mobile Robot, Proceedings of the 5th International Symposium on Advanced Electromechanical Motion Systems - ELECTROMOTION 2003, Vol. 2, Marrakesh, Morocco, November 26-28, 2003 S. Herle, S. Man, Gh. Lazea, P. Raica, Myoelectric Control Strategies for a Human Upper Limb Prosthesis, Journal of Control Engineering and Applied Informatics, accepted for publication, 2011 S. Herle, Algoritmi de control inteligent, Refererat de doctorat nr. 3, UTCN, 2005

[93]

[94] [95] [96]

[97]

[98]

[99]

[100]

[101]

[102]

[103]

[104]

[105] [106]

[107]

[108]

238

Bibliografie

[109] [110] [111] [112] [113] [114] [115] [116] [117] [118]

S. Herle, Sisteme inteligente, Refererat de doctorat nr. 1, UTCN, 2003 *****, Otto Bock System Electric Hand with DMC plus, catalog internal reference 647H326-600-03.05/3-MD http://www.ottobock.com/cps/rde/xchg/ob_com_en/hs.xsl/3722.html *****, Otto Bock MyoHand VariPlus Speed, catalog internal reference Otto Bock HealthCare Products GmbH 647H326-600-03.05/3-MD http://www.ottobock.com/cps/rde/xchg/ob_com_en/hs.xsl/19932.html http://www.ottobock.com/cps/rde/xchg/ob_com_en/hs.xsl/3633.html *****, Otto Bock Senso Hand Speed , catalog internal reference 647H495-140011.07/5-MD http://www.ottobock.com/cps/rde/xchg/ob_com_en/hs.xsl/3713.html *****, Otto Bock DynamicArm Elbow 12K100, catalog Otto Bock HealthCare Products GmbH, 2010 I. Moon, M. Lee, J. Chu, and M. Mun, Wearable EMH-based HCI for electric-powered wheelchair users with motor disabilities, Proceedings of the IEEE International Conference on Robotics and Automation, Barcelona, Spain, (April 2005, pp. 26602665). T. Felzer and B. Freisleben, HaWCoS: the hands-free wheelchair control system, Proceedings of the ACM SIGCAPH Conference on Assistive Technologies, Edinburgh, Scotland, ACM Press 2002, pp. 127-134. X. Zhang, X. Wang, B. Wang, T. Sugi and M. Nakamura, Finite state machine with adaptive electromyogram (EMG) feature extraction to drive meal assistance robot, IEEJ Transactions on Electronics, Information and Systems, Vol. 129, No. 2, 2009 pp. 308-313 S. Herle, S. Man, Gh. Lazea, C. Marcu, P. Raica, R. Robotin, Hierachical myoelectric control of a human upper limb prosthesis, CD Proceedings of the 19th IEEE International workshop on Robotics in Alpe-Adria-Danube Region, Budapest, Hungary, 23-25 June 2010, ISBN 978-1-4244-6884-3. http://www.faulhaber.com/uploadpk/EN_3268_BX4_DFF.pdf http://www.faulhaber.com/uploadpk/EN_382S_MIN.pdf http://www.faulhaber.com/uploadpk/EN_2248_BSL_MIN.pdf http://www.faulhaber.com/uploadpk/EN_261_MIN.pdf http://www.faulhaber.com/uploadpk/EN_2232_BX4_DFF.pdf http://www.faulhaber.com/uploadpk/EN_22F_DFF.pdf R. Kelly, V. Santibez and A. Lora, Control of robot manipulators in joint space, Springer-Verlag, London, 2005, ISBN 978-85233-994-4 C. Marcu, Gh. Lazea, S. Herle, R. Robotin, and L. Tamas, 3D Graphical Simulation of an Articulated Serial Manipulator based on Kinematic Models, 19th International Workshop on Robotics in Alpe-Adria-Danube Region - RAAD 2010, June 2010 C. Marcu, S. Herle, R. Robotin, M. Dobra, and Gh. Lazea, Motion Algorithms for an Industrial Robot Graphical Simulator. IEEE International Conference on Automation, Quality and Testing, Robotics, AQTR 2010, May 2010. S. Herle, Sistem inteligent de antrenare i evaluare a persoanelor cu amputaie sau parez la nivelul membrului superior- Raport de cercetare final, contract CNCSIS, TD 505/2007 S. Delp, F. Anderson, A. Arnold, P. Loan, A. Habib, Ch. John, E. Guendelman and D. Thelen, OpenSim: Open-Source Software to Create and Analyze Dynamic

[119]

[120]

[121]

[122] [123] [124] [125] [126] [127] [128] [129]

[130]

[131]

[132]

___________________________________________________________________________ 239

Bibliografie Simulations of Movement, IEEE Trans. on Biomedical Engineering, vol. 54, no. 11, Nov. 2007 [133] V. Grecu, L. Grecu, M. Demian and G. Demian, A Virtual System for Simulation of Human Upper Limb, Proceedings of the World Congress on Engineering 2009 Vol II,WCE 2009, July 1 - 3, 2009, London, U.K. L. Miclea, N. Jumate, S. Herle, C. Marcu, P. Raica, A. Sechel, M. Mnior, Experimentare metode de intervenie asupra protezei de umr cu utilizare n fracturile humerusului proximal cu risc de necroz avascular i asupra protezei de old cu utilizare n fracturile femurului. Experimentri n absena sau n prezena unor biomateriale nanostructurate utilizate la interfaa cu osul fiziologic (in vitro) pentru a mri adeziunea i integrarea protezelor n sistemul osos., Raport de cercetare-Etapa III, Proiect OSMOCEL, nr 41050, 2009 L. Miclea, N. Jumate, S. Herle, M. Mnior, P. Raica, Elaborarea unor tehnici i metode chirurgicale relevante n domeniul ortopedic, bazate pe medicina molecular i celular. Elaborarea i caracterizarea fizic, chimic i biomedical a unor nanobiostructuri colagenice., Raport de cercetare-Etapa I, Proiect OSMOCEL, nr 41050, 2007 L. Miclea, N. Jumate, I. Vida-Simiti, S. Herle, M. Mnior, A. Sechel, P. Raica, Elaborare metode i tehnici chirurgicale de introducere de tije flexibile intramedulare i extinderea osteosintezei n fracturile diafizei humerale. Elaborare structuri colagenice mixte, n prezen de hidroxiapatit nanostructurat, compatibile cu structura osoas, Raport de cercetare-Etapa II, Proiect OSMOCEL, nr 41050, 2008 http://commons.wikimedia.org/wiki/File:Perspective_Projection_Principle.jpg http://www.h-anim.org/ Varga L., Lazea G., Computer Simulation of a Human Arm Behavior, 2008 IEEE International Conference on Automation, Quality and Testing, Robotics, Editura U.T. Press, 2008 http://www.ottobock.com/cps/rde/xchg/ob_com_en/hs.xsl/11661.html S. Man, S. Herle, C. Cescon, G. Lazea, and R. Merletti, Online classication of electromyographic signals during nger isometric exion and the role of visual feedback, in Proceedings of International conference on control systems and computer science CSCS18, (Bucuresti), 2011 S. Man, C. Cescon, T. Vieira, S. Herle, G. Lazea, and R. Merletti, Classication of electromyographic signals during nger isometric exion: Using electrodes arrays. 2011 T. S. Payossim Sono and L. Luporini Menegaldo, Myoelectric Hand Prosthesis Force Control Through Servo Motor Current Feedback, Journal of Artificial Organs, vol. 33

[134]

[135]

[136]

[137] [138] [139]

[140] [141]

[142]

[143]

240

You might also like