2882695 FLT-CP-PLUS-1C-350
Information on this item
Item homepage Accessories Technical data Certificates PDF version Drawings Downloads

Back to navigation

Technical data

Standards
Housing material Inflammability class according to UL 94 Color Standards for air and creepage distances PBT V0 gray EN 60664-1 IEC 60664-1: 1992-10 IEC 61643-11 Degree of protection Mounting type Design Number of positions Ambient temperature (operation) Message: Surge protection fault Direction of action Width Height Length Pitch unit IP20 DIN rail: 35 mm DIN rail module, two-section, divisible 1 -40 C ... 80 C Optical, remote indicator contact 1L-N/PE 35.80 mm 70.00 mm 95.80 mm 2 Div.

Protective circuit
IEC category EN type Lightning protection class Nominal voltage UN Arrester rated voltage UC (L-N) I T1 T1 III/IV /50 kA (TN-C) 240 V AC (230/400 V AC ... 240/415 V AC) 350 V AC 350 V AC

http://eshop.phoenixcontact.co.uk/phoenix/assets.do?action=techdata&artnr=2882695

3/17/2012

PHOENIX CONTACT

Page 2 of 3

Arrester rated voltage UC (L-PEN) UT (TOV-proof) Nominal frequency fN Nominal load current IL Standby power consumption PC Nominal discharge surge current In (8/20) s (L-N) Nominal discharge surge current In (8/20) s (L-PEN) Lightning test current (10/350) s, charge Lightning test current (10/350) s, specific energy Lightning test current (10/350) s, peak value limp Lightning test current (10/350) s, charge Lightning test current (10/350) s, specific energy Lightning test current (10/350) s, peak value limp Impulse operate voltage at 6 kV (1.2/50)s (L-PEN) Protection level UP (L-N) Protection level UP (L-PEN) Response time (L-N) Max. required backup fuse with branch wiring Max. required backup fuse with V-type through wiring Recommended backup fuse maximum Short-circuit resistance IP with max. backup fuse (effective) Follow current quenching capacity If (L-N) Follow current quenching capacity If (L-PE) 415 V (5 s) 50 Hz (60 Hz) 125 A ( 55C) 2 mVA 25 kA 25 kA 25 kA (L-PEN) 12.5 As 160.00 kJ/ 25 kA 12.5 As 160.00 kJ/ 25 kA (1L-PEN) 1.5 kV 1.5 kV 1.5 kV 100 ns 315 A (gL/gG) 125 A (gL/gG) 160 A (gL/gG, 125 A with serial through wiring) 50 kA 50 kA (264 V AC) 50 kA (264 V AC) 25 kA (350 V AC)

Connection, protective circuit


Connection method Connection type IN Connection type OUT Connection method Screw thread Tightening torque Stripping length Conductor cross section stranded min. Conductor cross section stranded max. Conductor cross section solid min. Conductor cross section solid max. Conductor cross section AWG/kcmil min. Conductor cross section AWG/kcmil max Screw terminal blocks Biconnect screw terminal block Biconnect screw terminal block Biconnect terminal block M5 4.5 Nm 18 mm 2.5 mm 25 mm 2.5 mm 35 mm 13 2

Remote indicator contact

http://eshop.phoenixcontact.co.uk/phoenix/assets.do?action=techdata&artnr=2882695

3/17/2012

PHOENIX CONTACT

Page 3 of 3

Connection name Switching function Connection method Screw thread Tightening torque Stripping length Conductor cross section stranded min. Conductor cross section stranded max. Conductor cross section solid min. Conductor cross section solid max. Conductor cross section AWG/kcmil min. Conductor cross section AWG/kcmil max Maximum operating voltage Umax. AC Maximum operating voltage Umax DC Max. operating current Imax

Remote fault indicator contact PDT contact Plug-in/screw connection via COMBICON M2 0.25 Nm 7 mm 0.14 mm 1.5 mm 0.14 mm 1.5 mm 28 16 250 V AC 125 V DC 1 A AC (inductive) 1 A AC (ohmic) 30 mA DC (inductive) 200 mA DC (ohmic)

Standards
Standards/regulations IEC 61643-1 2005 EN 61643-11 2002 EN 61643-11/A11 2007 UL 1449 ed. 2