You are on page 1of 3

HITACHI H series (CPU port)

Compatible PLCs Family HITACHI H series Model EH-150, Micro-EH, H20, H40, H64, H200, H250, H252, H300, H302, H700, H702, H1000, H1002, H2000, H4010

HITACHI Web site: http://www.hitachi-ies.co.jp/english/products/plc/index.htm

HMI Setting:
Parameters PLC type Com port Baud rate Parity bit Data Bits Stop Bits HMI Station No. PLC Station No. Online Simulator Extend address mode Recommend HITACHI H-Series RS232 19200 Even 7 1 0 0 RS232, RS485 9600, 19200, 38400 Even 7 1 0-255 0-255 YES NO Broadcast command
Must match the PLCs port setting. Must match the PLCs port setting. Must match the PLCs port setting. Must match the PLCs port setting. Must match the PLCs port setting. Does not apply to this protocol. Does not apply to this protocol.

Option

Notes

NO

PLC Setting:
Communication mode

19200,E,7,1(default)

Select

Device address :
Bit/Word B B B B B B W W W W W W X Y M T R L TC WX WY WR WL WM Device Type Format hhh(h) hhh(h) hhh(h) hhh(h) hhh(h) hhh(h) hhh hhh hhh hhh hhh hhh Range hhh: 0~FFFF (h):0~F hhh: 0~FFFF (h):0~F hhh: 0~FFFF (h):0~F hhh: 0~FFFF (h):0~F hhh: 0~FFFF (h):0~F hhh: 0~FFFF (h):0~F hhh: 0~FF hhh: 0~270F hhh: 0~270F hhh: 0~270F hhh: 0~270F hhh: 0~270F Memo External Input-bit(X) External Output-bit(Y) Data area-bit(M) Timer(T) Internal Output(R) Link area-bit(L) Timer/Counter current value External Input-word(X) External Output-word(Y) Internal Output-word(R) Link area-word(L) Data area-word(M)

Wiring diagram :
WARNING: If your communications cable is not wired exactly as shown in our cable assembly instructions, damage to the MT8000 or loss of communications can result. CPU TYPE EH-150/CPU 104A EH-150/CPU 208A Port 1 Port 2 EH-150/CPU 308A EH-150/CPU 316A EH-150/CPU 448A Port 1 RS-232 RS-232 Port 2 RS-232 RS-232

RS-232/RS-485 RS-232 RS-232/RS-485 RS-232 RS-232/RS-485 RS-232

Switch Number 1 2 3, 4 OFF OFF 3 ON OFF ON OFF 5 6 ON 6 ON ON OFF OFF 7 8 OFF OFF Normal mode TRNS0 operation 4 ON ON OFF OFF Port1 speed 4,800 bps 9,600 bps 19,200 bps 38,400 bps transmission Default transmission Doesnt support

Dedicated port PHL Port2 speed Low High Low High 9,600 bps 38,400 bps 4,800 bps 19,200 bps Doesnt support Default Do not turn on. Do not turn on. Toggle-Switch PHL Low PHL High

(System mode) (System mode)

EH-150 port1/port 2 RS232 MT8000 RS-232 9P D-SUB


COM1 3 2 TX RX COM2 4 6 TX RX COM3 7 8 TX RX

HITACHI EH-150 port1 / port 2 8pin RJ45 Male 6 RD 5 SD 1 SG 8 RS 4 PHL 7 DR

5 GND 8 CTS

5 GND

5 GND

Port 1 / Port 2 8pin RJ45 Female

EH150port1 RS485 4wireRS422 EasyView MT8000 HMI PLC RS485port 9PinD-SUB FEMALE 1 2 3 4 5 RXRX+ TXTX+ GND

Hitachi EH-150 port1 8PinRJ45port 5 4 6 7 1 TXTX+ RXRX+ SG

EH150port1 RS485 2wire EasyView MT8000 HMI PLC RS485 port 9PinD-SUB FEMALE 1 2 3 4 5 RXRX+ TXTX+ GND

Hitachi EH-150 port1 8PinRJ45 port 5 4 6 7 1 TXTX+ RXRX+ SG

H series CPU RS232 port MT8000 PLC[232] 9P D-SUB Male


COM1 3 TX 2 RX 5 GND 8 CTS

HITACHI H series CPU RS232


15p D-SUB Male

3 RXD 2 TXD 9 SG 4 RTS 10 SG 5 CTS 7 DSR 8 PHL 14 PV12