Features of Renishaws Encoder Systems and similar products are the subjects of the following patents and patent applications: US 4959542 EP 0274491 US 4,974,962 EP 0274492 US 4926566 EP 0383901 JP 2,963,926 US 5,088,209 EP 0514081 JP 3,202,316 US 5,241,173 EP 0543513 JP 248,895/1993 US 5,302,820 EP 0748436 US 5,861,953 EP 826138 B JP 3,676,819 US 6,051,971 EP 1147377 JP 2003-512,611 US 6,588,333 B1
N-heptane
Acetone
CH3(CH2)5CH3
CH3COCH3
Chlorinated Solvents
Further information
For further information, relating to the installation of RGH41 readheads, see also the RGH41 Data sheet (part number L-9517-0186) and the scale installation guide (Part number M-9517-2855). This can be downloaded from our website www.renishaw.com and is also available from your local representative. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means without the written prior permission of Renishaw. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
Propan-2-ol
CH3CHOHCH3
Methylated Spirits
Disclaimer
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.
+70 C -20 C
+55 C 0 C
Optical centre
12.6*
14 7
4 4
3.6
8.6 3* 9
14.5
15.5 23.5 6 RGS40 scale 3 10 14.6 14.6 8.6 Q limit switch sensor position A-9531-0251 Q limit switch actuator Mount dimple up 0.13 (Roll tol. 1) 3* 10.5 Set-up LED 13 27
Arrow indicates forward direction of readhead relative to scale 44 38 4.7 max. (Pitch tol. 1) 0.8 3 A Scale surface
Detail A
Readhead Scale thickness 0.2
11.6* Readhead to scale clearance 2.2* 5* Arrow indicates optical and reference mark centre line
* Dimension measured from substrate
2*
Readhead mounting/installation
Mounting brackets The bracket must have a flat mounting surface, ensure conformance to the installation tolerances, allow adjustment to the rideheight of the readhead, and be sufficiently stiff to prevent deflection of the readhead during operation. For easier installation, the bracket should be adjusted for roll and yaw with respect to the axis of readhead travel before the scale is applied using the appropriate applicator. This can be done with a clock gauge and a precision square.
Readhead set-up To set nominal rideheight, either the blue or orange readhead spacer should be positioned with the aperture under the optical centre to allow normal LED function during set-up procedure. The orange spacer also helps to position readhead with respect to offset and yaw relative to the scale. The scale, readhead optical window and mounting face should be clean and free from obstructions. NOTE: Ensure readhead fixing screws are tightened to 0.5 Nm-0.7 Nm.
Roll 0 1
Yaw 0 1
When correctly installed, the set-up LED should be GREEN. The readhead should be moved slowly to ensure the set-up LED remains GREEN along the full axis travel. An external set-up signal (X or VX ) is also available on RGH41 readheads for use where the LED is not visible. In this case, 5 V indicates optimum set-up, while a 0 V signal indicates that the set-up should be adjusted.
Limit switch
A limit switch signal is output when the readhead sensor passes over the magnetic actuator. For full output specification refer to RGH41 Data sheet (Part number L-9517-0186).
To ensure unidirectional repeatability, the reference mark requires phasing with the scale in the direction of normal datuming operation. A reference pulse is output in both directions, but repeatability is guaranteed only in the phased direction. The readhead should be set up correctly ensuring a green LED indication over the full length of travel. The reference mark actuator should be installed as shown on the installation drawing. NOTE: It is recommended that a datum procedure is performed as part of any power-up sequence to ensure the correct datum position is recorded. NOTE: Reference mark output is synchronised with the incremental channels, giving unit of resolution pulse width. For further details see RGH41 Data sheet (Part number L-9517-0186).
Reference mark and limit switch actuator installation To aid location of reference mark and limit switches, the orange shim should be used as shown. reference mark actuator
Connections
RGH41 T, D, G, X, N, W, Y, H RS422A digital
52 16 66 17
40
Phasing procedure
The readhead must be moved over the reference mark in the direction to be used for the datuming operation. The reference mark is phased correctly when the set-up LED flashes red for 0.25 seconds. If it flashes orange or goes blank, the reference mark adjuster screw should be turned anti-clockwise by 1 8 turn and the procedure repeated until a red flash is obtained.
White White (link) Green Yellow Blue Red Violet Grey Pink Black Orange Clear Green/Yellow
Z+ Z-
turn
** Options 05/06 (dual limit) utilise the black wire for limit switch function P.
Options 03/04 (single limit) utilise the black wire for alarm function E+.
Connections continued
RGH41A, B 1 Vpp analogue
52 28 52 16
Connections continued
RGH41A, B 1 Vpp analogue The RGH41 reference mark output is not repeatable in both directions.
40
Certain controllers will flag an error when they see different reference mark positions in the forward and reverse directions. BID DIR pins allow the readhead to be configured to ignore the reference pulse output in the unphased direction (see section Reference mark set-up).
BID/DIR connections
BID/DIR connection
For bi-directional operation (normal)
To:-
BID DIR
For uni-directional operation
Colour Brown Brown (link) White White (link) Red Blue Yellow Green Violet Grey Pink Clear Green/Yellow Black Orange
Options 05/06 (dual limit) utilise the clear wire for limit switch function Vp. Options 03/04 (single limit) utilise the clear wire for external set-up function Vx. Only connected with options 17/18.
Electrical connection
Grounding and shielding
Outer shield
0V
IMPORTANT: The outer shield should be connected to the machine earth (Field Ground). The inner shield should be connected to 0V. Care should be taken to ensure that the inner and outer shields should insulated from each other. If the inner and outer shields are connected together, this will cause a short between 0V and earth, which could cause electrical noise issues.
Limit termination
Digital termination
Analogue termination
Readhead A B Z E+
V0 V1 V2+
V0 V1 V2-
A B Z E-
Cable Z 0 = 120 R
R P Q Vp Vq 5 V - 25 V
120R
1K
1K 0V #
5V
120R
# Customer electronics
Ripple
Options 00A - analogue output 1 Vpp (RGH41A and B only) 03A - digital head, single limit sensing, differential alarm signal (RGH41D, G, T and X only) 04A - digital head, single limit sensing, 3 state alarm signal (RGH41D, G, T and X only) 05A - digital head, dual limit sensing, single ended alarm signal (RGH41D, G, T and X only) 06A - digital head, dual limit sensing, 3 state alarm signal (RGH41D, G, T and X only) 17A - analogue output 1 Vpp, V termination with BID/DIR (RGH41B only) 18A - analogue output 1 Vpp, W termination with BID/DIR (RGH41B only) 61 20 MHz customer clock (RGH41H, N, W and Y only) 62 10 MHz customer clock (RGH41H, N, W and Y only) 63 5 MHz customer clock (RGH41H, N, W and Y only) Termination D - 15 pin D type plug (RGH41D, G, H, N, T, W, X and Y only) F - unterminated cable L - 15 pin D type plug (RGH41A and B only) S - to be used in conjunction with option 17A and 18A (RGH41B only -limits not available) V - 12 pin circular plug for analogue (RGH41B only - limits not available) W- 12 pin circular coupling (RGH41B only - limits not available) X - 16 pin in-line connector Cable length 05 - 0.5 m 10 - 1 m 15 - 1.5 m 30 - 3 m 50 - 5 m Output Analogue A - 1 Vpp (Dual limit version) B - 1 Vpp (Single limit version) Digital T - 10 m D - 5 m G - 2 m X - 1 m N - 0.4 m W - 0.2 m Y - 0.1 m H - 50 nm Readhead series
NOTE: Class 1M LED product. LED radiation. Do not view directly with optical instruments.
NOTE: Not all combinations are valid. Check valid options online at www.renishaw.com/epc