CONNECTION STRENGTH CHECK

AISC 2005 SPECIFICATION

BEAM B_309 (W18x50) LEFT END Member number [651] Depth = 1-6 Tw = 3/8 Bf = 7 1/2 Tf = 9/16 Ix = 800.00 Detail T = 1-3 1/2 Detail k = 1 1/4 Design k = 0.972 Ix = 800.0 Zx = 100.8 Material grade: A992 Fu = 65.0 Ksi Fy = 50.0 Ksi End elevation: 22-10 Other end elev.: 22-10 Span length: 23-5 5/8 Slope: 0.00 degrees Beam: Ix/L = 2.84 D/L = 0.064 > Fy/800 = 0.063 (AISC C-L3) Left end rotation = 0.00 Right end rotation = 0.00 Material length = 22-7 5/8 Plan rotation: 0.00 degrees Connecting nodes-Node 1 = [641] Column TS8x8x3/8 Z coordinates End 0 = -6.5000 End 1 = 276.0000 Frames to Column (TS8x8x3/8) C_308 Supporting member material grade: A500B Thickness = 0.375 Design t = 0.349 Top of bm to top of col: 2 Non-composite design Automatic reaction Automatic moment Design loads: Shear = 51.4 Kips Moment = 754.3 Kip-in Design reaction is 60.0 % of the allow. uniform steel bm. load Design moment is 25.0 % of the allowable plastic moment, Mp SHEAR PL WEB CONN. WITH FLANGE PL MOMENT CONN. Connection material-Plate: A36 Fu = 58.0 Fy = 36.0 Weld metal strength: Fexx = 70.0 Web plate: Thick = 3/8 Depth = 1-2 1/2 Web plate weld size = 1/4 Bolt type: A325N Bolt dia: 3/4 (Tension control field bolts) Bolt rows: 5 Bolt columns: 1 Bolt spacing: 3 Hole type in conn. to supported member: Short slot Flange plate connection: Grade: A36 Fu = 58.0 Fy = 36.0 Bolt type: A325SC Bolt dia: 3/4 Class A surface: mean slip coefficient = .35 (J3.8) Flange bolt rows: 4 Flange gage: 3 1/2 flange bolt spa. : 3 Flange pl hole type: Std. round Flange PL thickness = 3/8 Flange pl width = 1-0 taper width = 8 1/2 ---> Flange conn Pl Fy does not match beam flg. Fy. <--Pl to web weld size = 1/4 Pl to flg weld size = 1/4

(BEAM

B_309

LEFT END

CONTINUED) ds = 21.2 Kips

Allow. web bolt shear load: ss = 10.6 Kips, Fnv/OMEGA = 24.0 Ksi Allow. bolt tension Fnt = 90.00Ksi Fnt/OMEGA = 45.00Ksi Bolt area = 0.4418 Allow. flg bolt shear load: ss = 6.3 Kips ALLOWABLE STRENGTH CALCULATION Beam web shear Beam mom. strength (net sec.) Bolt brg. on web Connection block shear Conn. gross shear Conn. net shear Supported mbr. bolt shear Conn. brg.: supported mbr. Weld to supporting mbr. Shear on support Flange bolt shear Brg. on flange Beam flange tear-out Flange PL or L brg. Flg. PL weld to support Flg. PL tension/comp. Flange PL tear-out

NUMBER Rn/OMEGA ( 2) 127.7 Kips (211) 2653.4 Kip-in (110) 103.8 Kips ( 6) 67.3 Kips ( 17) 78.3 Kips ( 21) 66.1 Kips ( 1) 53.0 Kips (110) 89.3 Kips ( 22) 107.6 Kips ( 36) ( 68) ( 72) (259) ( 69) (280) (281) ( 85) 186.1 Kips 905.6 Kip-in 4138.7 3790.2 2561.4 2008.2 Kip-in Kip-in Kip-in Kip-in

AISC REF J4-2(a) F J3.10 J4.3 J4.2 J4.2 J3 J3.10 J2, Table J2.5 .5 G2 J,Table J3.2 J3.10 J4.3 J3.10 J,Table J2.5 D,E3,J4 J4.3

1781.5 Kip-in 2049.0 Kip-in

Eccentricity is neglected in the shear connection, misc note 34. Max PL thick to prevent shear punching failure: 0.640 Supporting HSS column b/t <= 1.4*SQRT[E/Fy], AISC B5.1. Column b/t = 19.94 maximum = 35.15 Computed flange force: 42.37 Kips Connection strength: Load ratio (Design/Allow.) Shear = 53.0 Kips 0.97 Moment = 905.6 Kip-in 0.83 CONNECTION IS OK (Strength equals or exceeds design loads)

W18x50