Table 1: Sample Summary Calculations Used to Determine Outdoor Air Ventilation Rates - Mechanically Ventilated
Zone Identification
Zone
Waste Management
F&B
Clean Store
Veg wash
Purchasing ofice
Stationary Store
waste Route
Laundry
Control room
Security
Battery
Service Corridor
receiving
HK Manager
Kitchen
HR room
Financial room
Staff Canteen
Clinic
Female change room
Male change room
prayer room
Office
Lobby
Store
Service Corridor
Store
Service Lobby
Passage
Recreational lounge
King room 1
King room 2
King room 3
King room 4
King room 5
Double room
Executive suite
King room 6
Butler

Occupancy Category
Storage rooms
Storage rooms
Storage rooms
Storage rooms
Office
Storage rooms
Corridor
Coin operated laundry
Telephone/Data entry
Living room
Telephone/Data entry
Corridor
receiving
Office
Cafeteria
Office
Office
Restaurant Dining Room
Clinic
Living room
Living room
Living room
Office
Lobbies
Storage
Corridor
Storage
Lobbies
Corridor
Living room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Living room

Standard Case: ASHRAE Std 62.1-2004 Ventilation Rate Procedure


Breathing
Table 6-2
Table 6-3
People
Zone
Table 6-1 Area
Occupant
Zone
Zone Air
System
Outdoor Air
Outdoor
Area (Sq.ft)
Outdoor Air Rate Density (# / Outdoor Air Distribution
Ventilation
Rate (cfm/
Airflow
(cfm/ sq.ft)
1000 sq.ft)
Flow Vbz Effectiveness
Efficiency
person)
Voz(CFM)
(CFM)
Ez
Ev(Zp)
964
0.12
116
1
116
1
392
0.12
47
1
47
1
134
0.12
16
1
16
1
134
0.12
16
1
16
1
130
5
0.06
8
1
8
1
149
0.12
18
1
18
0.8
1002
0.06
60
1
60
1
1842
7.5
0.06
14
216
1
216
1
279
5
0.06
2
27
1
27
1
157
5
0.06
3
24
1
24
1
88
5
0.06
5
1
5
1
1282
0.06
77
1
77
1
148
0.12
18
1
18
1
457
4
0.06
2
35
1
35
0.9
4043
7.5
0.18
10
803
1
803
1
620
5
0.06
9
82
1
82
1
802
5
0.06
12
108
1
108
1
848
7.5
0.18
50
528
1
528
1
147
5
0.18
3
41
1
41
1
897
5
0.06
3
69
1
69
1
1366
5
0.06
3
97
1
97
1
552
5
0.06
12
93
1
93
1
1351
5
0.06
2
91
1
91
1
297
5
0.06
10
68
1
68
1
790
0.12
95
1
95
1
4750
0.06
285
1
285
1
316
0.12
38
1
38
1
505
0.06
30
1
30
1
218
0.06
13
1
13
1
1018
5
0.06
25
186
1
186
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
937
5
0.06
2
66
1
66
1
1289
5
0.06
4
97
1
97
1
611
5
0.06
2
47
1
47
1
317
5
0.06
2
29
1
29
1

Design Case
Outdoor Air Outdoor Air Zone Primary Air
Intake Flow Intake Flow
Flow Fraction
Vot(CFM)
(CFM)
Vpz(CFM)
116
47
16
16
8
22
60
216
27
24
5
77
18
39
803
82
108
528
41
69
97
93
91
68
95
285
38
30
13
186
47
47
47
47
47
66
97
47
29

763
312
106
106
21
117
67
400
32
25
74
123
42
42
6148
85
117
2449
43
731
572
127
117
201
150
583
180
53
21
201
191
191
191
191
191
276
191
201
191

907
456
231
274
121
91
730
4651
1662
322
880
1971
331
223
11522
740
975
3559
274
685
1074
392
806
210
668
3116
600
1728
165
1586
856
854
856
854
1073
1694
767
553
721

Primary
Outdoor Air
Fraction
Zp=Voz/Vpz

% Increase
Over Standard

0.13
0.10
0.07
0.06
0.06
0.20
0.08
0.05
0.02
0.08
0.01
0.04
0.05
0.16
0.07
0.11
0.11
0.15
0.15
0.10
0.09
0.24
0.11
0.32
0.14
0.09
0.06
0.02
0.08
0.12
0.05
0.05
0.05
0.05
0.04
0.04
0.13
0.08
0.04

y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y

Ez = 1 (air outdoor air


distribution is
as per
overhead) calculation

Ev=1 if
Zp<0.15,
Ev=0.9 if
Zp<0.25

Primary airflow to
zone from
outdoor air outdoor air to
ratio of outdoor actual outdoor
airhandler
as per
space
air to equipment air / outdoor air
including outdoor
calculation
(project)
(cfm) air
per calculation
and recirculated
return air

Table 1: ASHRAE Std 62.1-2004 Ventilation rate Procedure


Zone Identification

Zone

Occupancy Category

Standard Case: ASHRAE Std 62.1-2004 Ventilation Rate Procedure


Breathing
Table 6-2
People
Zone
Table 6-1 Area
Occupant
Zone
Zone Air
Outdoor Air
Outdoor
Area (Sq.ft)
Outdoor Air Rate Density (# / Outdoor Air Distribution
Rate (cfm/
Airflow
(cfm/ sq.ft)
1000 sq.ft)
Flow Vbz Effectiveness
person)
Voz(CFM)
(CFM)
Ez

Table 6-3
System
Ventilation
Efficiency
Ev(Zp)

Design Case
Outdoor Air Outdoor Air Zone Primary Air
Intake Flow Intake Flow
Flow Fraction
Vot(CFM)
(CFM)
Vpz(CFM)

Primary
Outdoor Air
Fraction
Zp=Voz/Vpz

% Increase
Over Standard

Waste Management

Storage rooms

964

0.12

116

116

116

763

907

0.13

560%

F&B

Storage rooms

392

0.12

47

47

47

312

456

0.10

563%

Clean Store

Storage rooms

134

0.12

16

16

16

106

231

0.07

559%

Veg wash

Storage rooms

134

0.12

16

16

16

106

274

0.06

559%

Purchasing ofice

Office

130

0.06

21

121

0.06

169%

Stationary Store

Storage rooms

149

0.12

18

18

0.9

20

117

91

0.20

489%

waste Route

Corridor

1002

0.06

60

60

60

67

730

0.08

11%

Laundry

Coin operated laundry

1842

7.5

0.06

14

216

216

216

400

4651

0.05

86%

Control room

Telephone/Data entry

279

0.06

27

27

27

32

1662

0.02

20%

Security

Living room

157

0.06

24

24

24

25

322

0.08

2%

Battery

Telephone/Data entry

88

0.06

74

880

0.01

1302%

Service Corridor

Corridor

1282

0.06

77

77

77

123

1971

0.04

60%

receiving

receiving

148

0.12

18

18

18

42

331

0.05

136%

HK Manager

Office

457

0.06

35

35

0.9

39

42

223

0.16

7%

Kitchen

Cafeteria

4043

7.5

0.18

10

803

803

803

6148

11522

0.07

666%

HR room

Office

620

0.06

82

82

82

85

740

0.11

3%

Financial room

Office

802

0.06

12

108

108

108

117

975

0.11

8%

Staff Canteen

Restaurant Dining Room

848

7.5

0.18

50

528

528

528

2449

3559

0.15

364%

Clinic

Clinic

147

0.18

41

41

41

43

274

0.15

4%

Female change room

Living room

897

0.06

69

69

69

731

685

0.10

962%

Male change room

Living room

1366

0.06

97

97

97

572

1074

0.09

490%

prayer room

Living room

552

0.06

12

93

93

0.9

103

127

392

0.24

23%

Office

Office

1351

0.06

91

91

91

117

806

0.11

28%

Lobby

Lobbies

297

0.06

10

68

68

0.8

85

201

210

0.32

137%

Store

Storage

790

0.12

95

95

95

150

668

0.14

58%

Service Corridor

Corridor

4750

0.06

285

285

285

583

3116

0.09

105%

Store

Storage

316

0.12

38

38

38

180

600

0.06

375%

Service Lobby

Lobbies

505

0.06

30

30

30

53

1728

0.02

75%

Passage

Corridor

218

0.06

13

13

13

21

165

0.08

61%

Recreational lounge

Living room

1018

0.06

25

186

186

186

201

1586

0.12

8%

King room 1

Bed room

611

0.06

47

47

47

191

856

0.05

309%

King room 2

Bed room

611

0.06

47

47

47

191

854

0.05

309%

King room 3

Bed room

611

0.06

47

47

47

191

856

0.05

309%

King room 4

Bed room

611

0.06

47

47

47

191

854

0.05

309%

King room 5

Bed room

611

0.06

47

47

47

191

1073

0.04

309%

Double room

Bed room

937

0.06

66

66

66

276

1694

0.04

317%

Executive suite

Bed room

1289

0.06

97

97

97

191

767

0.13

96%

King room 6

Bed room

611

0.06

47

47

47

201

553

0.08

331%

Butler

Living room

317

0.06

29

29

29

191

721

0.04

558%

MAHOR HOUSE LEVEL-9.0


Table 1: Sample Summary Calculations Used to Determine Outdoor Air Ventilation Rates - Mechanically Ventilated
Zone Identification
Zone
Conference room
Prefunction Majlis
Entrance foyer
Private dining&All day dining
Office
Majlis
Lobby Lounge/ Bar
Corridor
Library/ Boutique
Retail
Guest Relations
Entrance 1
Reception
Public Corridor
Common Area
Front Office
Italian Restaurant
Office 2
Passage 6
Clerks,Reception & Sales
King Suite 1
King Suite 2
King Suite 3
King Suite 4
King Suite 5
Passage 7,Lobby 3
Double Suite
Junior Suite
Executive Suite Bedroom

Occupancy Category
Conference
Majlis
Main entry lobbies
Restaurant dining room
Office Space
Majlis
Lobbies
Corridor
Library
Warehouses
Living room
Main entry lobbies
Reception
Corridor
Corridor
Office Space
Restaurant dining room
Office Space
Corridor
Office Space
Living room
Living room
Living room
Living room
Living room
Corridor
Living room
Living room

Standard Case: ASHRAE Std 62.1-2004 Ventilation Rate Procedure


Breathing
Table 6-2
Table 6-3
People
Zone
Table 6-1 Area
Occupant
Zone
Zone Air
System
Outdoor Air
Outdoor
Area (Sq.ft)
Outdoor Air Rate Density (# / Outdoor Air Distribution
Ventilation
Rate (cfm/
Airflow
(cfm/ sq.ft)
1000 sq.ft)
Flow Vbz Effectiveness
Efficiency
person)
Voz(CFM)
(CFM)
Ez
Ev(Zp)
1822
5
0.06
82
519
1
519
1
375
5
0.06
15
98
1
98
1
804
5
0.06
5
73
1
73
1
4112
7.5
0.18
70
1265
1
1265
0.8
576
5
0.06
1
40
1
40
1
248
5
0.06
2
25
1
25
1
2258
5
0.06
70
485
1
485
1
648
0.06
39
1
39
0.9
388
5
0.06
5
48
1
48
1
398
5
0.06
2
34
1
34
1
93
5
0.06
1
11
1
11
1
426
5
0.06
5
51
1
51
1
2546
5
0.06
8
193
1
193
1
911
0.06
55
1
55
1
514
0.06
31
1
31
1
243
5
0.06
2
25
1
25
1
2645
5
0.06
67
494
1
494
1
42
5
0.06
1
8
1
8
0.9
332
0.06
20
1
20
1
812
5
0.06
6
79
1
79
1
762
5
0.06
2
56
1
56
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
1356
0.06
81
1
81
1
720
5
0.06
2
53
1
53
1
816
5
0.06
2
59
1
59
1
1139
5
0.06
2
78
1
78
1

Design Case
Outdoor Air Outdoor Air Zone Primary Air
Intake Flow Intake Flow
Flow Fraction
Vot(CFM)
(CFM)
Vpz(CFM)
519
98
73
1581
40
25
485
43
48
34
11
51
193
55
31
25
494
8
20
79
56
47
47
47
47
81
53
59
78

551
106
551
2989
127
32
509
43
53
42
21
53
201
55
551
53
562
11
32
85
255
191
191
191
191
1261
191
191
233

3647
975
1414
4895
260
604
3343
206
1162
1176
411
2010
3220
2989
316
168
4221
47
290
939
933
799
833
831
831
1261
943
1350
1967

Primary
Outdoor Air
Fraction
Zp=Voz/Vpz

% Increase
Over Standard

0.14
0.10
0.05
0.26
0.15
0.04
0.15
0.19
0.04
0.03
0.03
0.03
0.06
0.02
0.10
0.15
0.12
0.16
0.07
0.08
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.04
0.04

y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y

Table 1: ASHRAE Std 62.1-2004 Ventilation rate Procedure


Zone Identification

Zone

Occupancy Category

Standard Case: ASHRAE Std 62.1-2004 Ventilation Rate Procedure


Breathing
Table 6-2
People
Zone
Table 6-1 Area
Occupant
Zone
Zone Air
Outdoor Air
Outdoor
Area (Sq.ft)
Outdoor Air Rate Density (# / Outdoor Air Distribution
Rate (cfm/
Airflow
(cfm/ sq.ft)
1000 sq.ft)
Flow Vbz Effectiveness
person)
Voz(CFM)
(CFM)
Ez

Table 6-3
System
Ventilation
Efficiency
Ev(Zp)

Design Case
Outdoor Air Outdoor Air Zone Primary Air
Intake Flow Intake Flow
Flow Fraction
Vot(CFM)
(CFM)
Vpz(CFM)

Primary
Outdoor Air
Fraction
Zp=Voz/Vpz

% Increase
Over Standard

6%

Conference room

Conference

1822

0.06

82

519

519

519

551

3647

0.14

Prefunction Majlis

Majlis

375

0.06

15

98

98

98

106

975

0.10

9%

Entrance foyer

Main entry lobbies

804

0.06

73

73

73

551

1414

0.05

652%

Private dining&All day dining

Restaurant dining room

4112

7.5

0.18

70

1265

1265

0.8

1581

2989

4895

0.26

89%

Office

Office Space

576

0.06

40

40

40

127

260

0.15

221%

Majlis

Majlis

248

0.06

25

25

25

32

604

0.04

29%

Lobby Lounge/ Bar

Lobbies

2258

0.06

70

485

485

485

509

3343

0.15

5%

Corridor

Corridor

648

39

39

0.9

43

43

206

0.19

0%

Library/ Boutique

Library

388

0.06

48

48

48

53

1162

0.04

10%

Retail

Warehouses

398

0.06

34

34

34

42

1176

0.03

24%

Guest Relations

Living room

93

0.06

11

11

11

21

411

0.03

98%

Entrance 1

Main entry lobbies

426

0.06

51

51

51

53

2010

0.03

5%

Reception

Reception

2546

0.06

193

193

193

201

3220

0.06

4%

0.06

Public Corridor

Corridor

911

0.06

55

55

55

55

2989

0.02

1%

Common Area

Corridor

514

0.06

31

31

31

551

316

0.10

1687%

Front Office

Office Space

243

0.06

25

25

25

53

168

0.15

116%

Italian Restaurant

Restaurant dining room

2645

0.06

67

494

494

494

562

4221

0.12

14%

Office 2

Office Space

42

0.06

0.9

11

47

0.16

32%

Passage 6

Corridor

332

20

20

20

32

290

0.07

61%

Clerks,Reception & Sales

Office Space

812

0.06

79

79

79

85

939

0.08

8%

King Suite 1

Living room

762

0.06

56

56

56

255

933

0.06

358%

King Suite 2

Living room

611

0.06

47

47

47

191

799

0.06

309%

King Suite 3

Living room

611

0.06

47

47

47

191

833

0.06

309%

King Suite 4

Living room

611

0.06

47

47

47

191

831

0.06

309%

King Suite 5

Living room

611

0.06

47

47

47

191

831

0.06

309%

Passage 7,Lobby 3

Corridor

1356

81

81

81

1261

1261

0.06

1450%

Double Suite

Living room

720

0.06

53

53

53

191

943

0.06

259%

Junior Suite

Living room

816

0.06

59

59

59

191

1350

0.04

224%

1139

0.06

78

78

78

233

1967

0.04

197%

Executive Suite Bedroom

0.06

0.06

MAHOR HOUSE LEVEL-12.5


Table 1: Sample Summary Calculations Used to Determine Outdoor Air Ventilation Rates - Mechanically Ventilated
Zone Identification
Zone
Service lobby
Lift lobby &Passage
House keeping
Prayer room
Admin & GM
Reception 1
Filing
Board room
King suite 1
King suite 2
King suite 3
King suite 4
King suite 5
Double suite
Junior suite
Passage
Office
Reservation
Reception
Corridor
Training room

Occupancy Category
Corridor
Corridor
Storage rooms
Place of religious work
Office
Reception
Office space
Meeting
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Corridor
Office
Booking
Reception
Corridor
Office space

Standard Case: ASHRAE Std 62.1-2004 Ventilation Rate Procedure


Breathing
Table 6-2
Table 6-3
People
Zone
Table 6-1 Area
Occupant
Zone
Zone Air
System
Outdoor Air
Outdoor
Area (Sq.ft)
Outdoor Air Rate Density (# / Outdoor Air Distribution
Ventilation
Rate (cfm/
Airflow
(cfm/ sq.ft)
1000 sq.ft)
Flow Vbz Effectiveness
Efficiency
person)
Voz(CFM)
(CFM)
Ez
Ev(Zp)
564
0.06
34
1
34
1
621
0.06
37
1
37
1
319
0.12
38
1
38
1
695
5
0.06
12
102
1
102
0.9
513
5
0.06
11
86
1
86
1
272
5
0.06
7
51
1
51
1
332
5
0.06
20
1
20
1
223
5
0.06
10
63
1
63
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
690
5
0.06
2
51
1
51
1
781
5
0.06
2
57
1
57
1
1319
0.06
79
1
79
1
732
5
0.06
7
79
1
79
1
275
5
0.06
4
37
1
37
1
338
5
0.06
4
40
1
40
1
188
0.06
11
1
11
1
303
5
0.12
25
161
1
161
1

Design Case
Outdoor Air Outdoor Air Zone Primary Air
Intake Flow Intake Flow
Flow Fraction
Vot(CFM)
(CFM)
Vpz(CFM)
34
37
38
113
86
51
20
63
47
47
47
47
47
51
57
79
79
37
40
11
161

170
43
64
255
115
53
21
64
191
191
191
191
191
201
215
82
85
42
42
21
170

1278
857
367
507
967
242
653
401
859
859
895
895
895
1333
1603
996
1704
939
549
261
1113

Primary
Outdoor Air
Fraction
Zp=Voz/Vpz

% Increase
Over Standard

0.03
0.04
0.10
0.20
0.09
0.21
0.03
0.16
0.05
0.05
0.05
0.05
0.05
0.04
0.04
0.08
0.05
0.04
0.07
0.04
0.14

y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y

Table 1: ASHRAE Std 62.1-2004 Ventilation rate Procedure


Zone Identification

Zone

Occupancy Category

Standard Case: ASHRAE Std 62.1-2004 Ventilation Rate Procedure


Breathing
Table 6-2
People
Zone
Table 6-1 Area
Occupant
Zone
Zone Air
Outdoor Air
Outdoor
Area (Sq.ft)
Outdoor Air Rate Density (# / Outdoor Air Distribution
Rate (cfm/
Airflow
(cfm/ sq.ft)
1000 sq.ft)
Flow Vbz Effectiveness
person)
Voz(CFM)
(CFM)
Ez

Table 6-3
System
Ventilation
Efficiency
Ev(Zp)

Design Case
Outdoor Air Outdoor Air Zone Primary Air
Intake Flow Intake Flow
Flow Fraction
Vot(CFM)
(CFM)
Vpz(CFM)

Primary
Outdoor Air
Fraction
Zp=Voz/Vpz

% Increase
Over Standard

Service lobby

Corridor

564

0.06

34

34

34

170

1278

0.03

402%

Lift lobby &Passage

Corridor

621

0.06

37

37

37

43

857

0.04

15%

House keeping

Storage rooms

319

38

38

38

64

367

0.10

67%

Prayer room

Place of religious work

695

0.12
0.06

12

102

102

0.9

113

255

507

0.20

126%

Admin & GM

Office

513

0.06

11

86

86

86

115

967

0.09

34%

Reception 1

Reception

272

0.06

51

51

51

53

242

0.21

3%

Filing

Office space

332

0.06

20

20

20

21

653

0.03

5%

Board room

Meeting

223

0.06

10

63

63

63

64

401

0.16

1%

King suite 1

Bed room

611

0.06

47

47

47

191

859

0.05

309%

King suite 2

Bed room

611

0.06

47

47

47

191

859

0.05

309%

King suite 3

Bed room

611

0.06

47

47

47

191

895

0.05

309%

King suite 4

Bed room

611

0.06

47

47

47

191

895

0.05

309%

King suite 5

Bed room

611

0.06

47

47

47

191

895

0.05

309%

Double suite

Bed room

690

0.06

51

51

51

201

1333

0.04

291%

Junior suite

Bed room

781

0.06

57

57

57

215

1603

0.04

278%

Passage

Corridor

1319

79

79

79

82

996

0.08

4%

Office

Office

732

0.06

79

79

79

85

1704

0.05

8%

Reservation

Booking

275

0.06

37

37

37

42

939

0.04

15%

Reception

Reception

338

0.06

40

40

40

42

549

0.07

4%

Corridor

Corridor

188

11

11

11

21

261

0.04

86%

Training room

Office space

303

161

161

161

170

1113

0.14

5%

0.06

0.06
5

0.12

25

MAHOR HOUSE LEVEL-16.0


Table 1: Sample Summary Calculations Used to Determine Outdoor Air Ventilation Rates - Mechanically Ventilated
Zone Identification
Zone
Exit corridor
Double suite 1
King suite 1
Double suite 2
Prince suite
King suite 2
King suite 3
Double suite 3
King suite 4
King suite 5
King suite 6
King suite 7
King suite 8
Passage&Service stair

Occupancy Category
Corridor
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Bed room
Corridor

Standard Case: ASHRAE Std 62.1-2004 Ventilation Rate Procedure


Breathing
Table 6-2
Table 6-3
People
Zone
Table 6-1 Area
Occupant
Zone
Zone Air
System
Outdoor Air
Outdoor
Area (Sq.ft)
Outdoor Air Rate Density (# / Outdoor Air Distribution
Ventilation
Rate (cfm/
Airflow
(cfm/ sq.ft)
1000 sq.ft)
Flow Vbz Effectiveness
Efficiency
person)
Voz(CFM)
(CFM)
Ez
Ev(Zp)
3266
0.06
196
1
196
1
711
5
0.06
2
53
1
53
1
623
5
0.06
2
47
1
47
1
701
5
0.06
2
52
1
52
1
2116
5
0.06
4
147
1
147
1
668
5
0.06
2
50
1
50
1
611
5
0.06
2
47
1
47
1
704
5
0.06
2
52
1
52
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
611
5
0.06
2
47
1
47
1
838
0.06
50
1
50
1

Design Case
Outdoor Air Outdoor Air Zone Primary Air
Intake Flow Intake Flow
Flow Fraction
Vot(CFM)
(CFM)
Vpz(CFM)
196
53
47
52
147
50
47
52
47
47
47
47
47
50

212
64
223
64
360
212
212
215
212
212
212
212
212
50

5936
1202
943
1073
2926
1001
996
1174
1113
897
1136
975
1147
1206

Primary
Outdoor Air
Fraction
Zp=Voz/Vpz

% Increase
Over Standard

0.03
0.04
0.05
0.05
0.05
0.05
0.05
0.04
0.04
0.05
0.04
0.05
0.04
0.04

y
y
y
y
y
y
y
y
y
y
y
y
y
y

Table 1: ASHRAE Std 62.1-2004 Ventilation rate Procedure


Zone Identification

Zone

Occupancy Category

Standard Case: ASHRAE Std 62.1-2004 Ventilation Rate Procedure


Breathing
Table 6-2
People
Zone
Table 6-1 Area
Occupant
Zone
Zone Air
Outdoor Air
Outdoor
Area (Sq.ft)
Outdoor Air Rate Density (# / Outdoor Air Distribution
Rate (cfm/
Airflow
(cfm/ sq.ft)
1000 sq.ft)
Flow Vbz Effectiveness
person)
Voz(CFM)
(CFM)
Ez
0.06

Table 6-3
System
Ventilation
Efficiency
Ev(Zp)

Design Case
Outdoor Air Outdoor Air Zone Primary Air
Intake Flow Intake Flow
Flow Fraction
Vot(CFM)
(CFM)
Vpz(CFM)

Primary
Outdoor Air
Fraction
Zp=Voz/Vpz

% Increase
Over Standard

Exit corridor

Corridor

3266

196

196

196

212

5936

0.03

8%

Double suite 1

Bed room

711

0.06

53

53

53

64

1202

0.04

22%

King suite 1

Bed room

623

0.06

47

47

47

223

943

0.05

371%

Double suite 2

Bed room

701

0.06

52

52

52

64

1073

0.05

23%

Prince suite

Bed room

2116

0.06

147

147

147

360

2926

0.05

145%

King suite 2

Bed room

668

0.06

50

50

50

212

1001

0.05

323%

King suite 3

Bed room

611

0.06

47

47

47

212

996

0.05

354%

Double suite 3

Bed room

704

0.06

52

52

52

215

1174

0.04

312%

King suite 4

Bed room

611

0.06

47

47

47

212

1113

0.04

354%

King suite 5

Bed room

611

0.06

47

47

47

212

897

0.05

354%

King suite 6

Bed room

611

0.06

47

47

47

212

1136

0.04

354%

King suite 7

Bed room

611

0.06

47

47

47

212

975

0.05

354%

King suite 8

Bed room

611

0.06

47

47

47

212

1147

0.04

354%

Passage&Service stair

Corridor

838

50

50

50

50

1206

0.04

0%

0.06