You are on page 1of 3

MADE IN ITALY

Products series C (Cooling)


Application: cold stores, refrigerated counters, display cabinets, catering, heating market, etc. Special feature:
Parameters programming shared into three levels, easier and intuitive, values visualization of the setting parameters without entering in setting function and just pressing one button.
3

programming levels, menus managed, with the possibility of establishing which are the parameters present at the second level.

rd

Possibility of limiting the access by password. Permanent memory alarms. Alarms temperature with storage of reached temperature (min/max) and duration ( HACCP). Alarms temperature in case of off power with storage of the reached temperature (min/max) and time of return within the limits (HACCP).
C110

Product C220 C320

Keypad lock. Continuous cycle managing.


Dimension

Digital input for defrost management or cell door. Protection parameters for the compressor establishing the off and on minimum time. Decimal resolution in the filed -9,9 99,9 C. Display 3 digit H 14,2 mm, high efficiency.

Frontal 32 x 74 Box 4 DIN Power supply 230 Vac 50/60Hz 115 Vac 50/60Hz 24 Vac/dc 12 Vac/dc Relay outputs Compressor 16(9)A 250V~ Compressor 8(3)A 250V~ Defrost 8(3)A 250V~ Fan 8(3)A 250V~ Allarm 8(3)A 250V~ Other outputs Buzzer allarm Probe inputs NTC room (-50 105 C) NTC room (-40 155 C) NTC evaporator (-50 105 C) Others inputs Digital input standard optional

Option:
Panel mounting version available in single or multiple packaging (OEM).

Custom made programming and serigraphy.


COMPOSITION CODE
C= Cooling S= Solar V= Viewer N relay of regulation

C320X300B
N probe input Progressive number X= 230 Vac R= 115 Vac Y= 12 Vac/dc Z= 24 Vac/dc

Allarm output A= relay and buzzer B= buzzer R= relay N= no allarm output Progressive number

2= panel mounting series 2 (Front.29x62) 3= panel mounting series 3 (Front.32x74) 4= 4 DIN box

unavailable

Series C 05-2009 rev.6

PARAMETERS TABLE
Up Increase
ALM

A
3 level programming

B Parameter code

Product Default values

C110 ntc 50K

DEF

SET PRG

Menu code

C110 ntc 10K

Exit (1 sec.) Exit without saving

Enter Exit saving data

C220

Description Limitations menu Minimum programmable set-point Maximum programmable set-point Outputs delay time at power-on Compressor menu Compressor relay minimum off time Compressor relay minimum on time Continuous cycle duration Action type: cooling / heating Temperature differential Probe utilised: ntc 10K (ntL), ntc 50K (ntH) Room probe (compressor) calibration Faulty probe ON time Faulty probe OFF time Alarms menu Alarms relative to set-point or absolute alarms High temperature alarm Low temperature alarm Temperature alarm delay Temperature alarms inhibition at power-on Inhibition of temperature alarms and maximum display delay following defrost Temp. alarms inhibition after continuous cycle Buzzer and alarms relay OFF/ On Defrost menu Defrost OFF / On time / Ont temperature Defrost, electrical or cycle inversion. Defrosting type Interval between two defrost cycles Defrost cycle duration (max. if with evaporator probe) Defrost end temperature Display type during defrost cycle Dripping time after defrost Evaporator probe calibration Defrost delay after continuous cycle Digital input menu Digital input configuration Digital input alarm delay Automatic variation of set-point from digital input, curtain switch, night time operation Door open control Fans menu Fans operating mode With compressor OFF fans: With defrost ON fans: Fans trip temperature Fans speed regulator forcing Post-dripping fans stop Display menu Resolution for integer or decimal C, Data display in or C F Temperature normally displayed Room probe temperature display. Evaporator probe temperature display. Software release Parameters table rd Password required to access 3 level programming. Parameters present in 2 level programming by default
nd

rd

Down Decrease

C320

Range -50 LHS C LLS 105 C 0 255 Min. OFF 60 Min. OFF 60 Min. 0.0 24.0 Min. CL / Ht 0.5 20.0 C ntL / ntH -12.0 12.0 C 0 255 Min. 0 255 Min. Ab / rE ALL 105 C -50 ALH C 0 255 Min. 0.0 24.0 h.m 0 255 Min. 0 255 Min. OFF / On OFF / On / Ont EL / inc dco/drE/dMA/did OFF 120 h 0 255 Min. -50 50 C rt / it / dEF 0 120 Min. -12.0 12.0 C 0.0 24.0 h.m OFF/1/2/3/4 0 255 Min. -20 20 C 0/1 OFF / On / Ont OFF / On OFF / On -50 50 C OFF 50 C 0 255 Min. 0.0 / 0 / C F Pco / PdF C C

LI LLS LHS LOd CPr COF Con CCt CHC Cdi CPS CCA CFn CFF ALL ALC ALH ALL ALd Ado Add AdC AnF dEF dFn dFt dSL din ddu dOF drE ddc dCA ddd id iFn idd iSt ido FAn FFn FcF Fdn FSt FtC FFd rEA rES rCF rPr rPc rPd rEL rtA rPS 30 0FF 0FF -30 150

-40 100 0 2 3 0.0 Ht 2.0 ntH 0.0 10 20 Ab 155 -40 15 1.3 30 30 OFF OFF OFF N.D. drE 8 8 25 25 N.D. dEF dEF 1 1 N.D. 0.0 OFF 15 0 0 N.D. N.D. N.D. N.D. N.D. N.D. 0.0 C N.D. N.D. N.D. OFF 105 -50 ntL CL

-40 100 0 2 3 0.0 CL 2.0 N.D. 0.0 10 20 Ab 105 -50 15 1.3 30 30 OFF Ont EL drE 8 25 8 dEF 1 0.0 0.0 OFF 15 0 0 N.D. N.D. N.D. N.D. N.D. N.D. 0.0 C Pco OFF

-40 100 0 2 3 0.0 CL 2.0 N.D. 0.0 10 20 Ab 105 -50 15 1.3 30 30 OFF Ont EL drE 8 25 8 dEF 1 0.0 0.0 OFF 15 0 0 Ont OFF OFF 2 10 10 0.0 C Pco OFF

OFF / On

TECHNICAL DATA: Plastic enclosure in class V0 self-extinguishing material; power supply depending on model: 230Vac 10% 50/60 Hz; 115Vac 10% 50/60 Hz; 12Vac/dc 10%; 24Vac/dc 10%; max. power input 3VA; display: three digits, red LEDs, height 14,2 mm; inputs: C110 n 1 10K or 50K ntc probe; C220 and C320 n 10K ntc probes ; digital input: voltage-free contacts; Relay outputs: compressor depending 2 on model 8(3)A 250Vac or 16(9)A 250Vac, defrosting, fans or alarms 8(3)A 250Vac, total maximum load connectable to instrument 16A; retention of data in non-volatile memory (EEPROM); Flush-mounted electronic thermoregulators; classification in accordance with automatic operation characteristics 1B; degree of protection: II; rated impulse voltage 2,5 KV; contact opening: micro-disconnection; tracking index PTI 175V; situation of pollution of the device: normal; electrical connection to be executed with resistant conductors up to 108 software class A; heat and fire resistance ca tegory D; operating temperature range 0 60 with non-condensing humidity 0 C; C 90%; storage temperature -20 70 measurement ra nge: 10K ntc 50 105 50K ntc -40 155 resolution: 0.1 (-9.9 99.9), C; C, C; C 1 instrument precision 0.7 1 digit; device utilisable for operating duty and not as a safety system. F; C,

Series C 05-2009 rev.6

DIMENSIONS

Contenitore ad incasso - Panel mounting box


74 70,5

ALM DEF SET PRG

32

12 11 10 9 8 7 6 5 4 3 2 1

74

78

28

Dima di foratura - Drilling template


71

28,5

Scatola 4 DIN - Box 4 DIN

9,00 cm

4,40 cm

1,6 cm

7,00 cm

6,50 cm

The Manufacturer reserves the right to withdraw the product from production or make technical modifications whenever it deems necessary and with no obligation to provide notice. Although all due care has been applied in the preparation of this documentation, Termoregolatori Campini-Corel declines all liability connected with its use.

TERMOREGOLATORI CAMPINI-COREL S.p.A. Mariano Comense / Como / Italy www.campinicorel.it Tel. +39 031 7530111

Series C 05-2009 rev.6

4,50 cm