You are on page 1of 8

ISO-SIGMA

energia e gesto lda

IEC CYLINDRICAL FUSE SYSTEM

ISO-SIGMA

NH FUSE SYSTEM

LOW VOLTAGE FUSE LINKS

energia e gesto lda


CIRCUIT PROTECTION SOLUTIONS

Bussmann are one of the worlds leading suppliers of fuses and fusible protection systems. Provider of the worlds first truly global product line, each product is backed
IEC BUSSBAR FUSE SYSTEM CONTRACTOR PRODUCTS

NH FUSE SYSTEM

LOW VOLTAGE FUSE LINKS

by an efficient world-wide distribution network service and unrivalled technical support. Bussmann circuit protection solutions comply with major international standards: BS, IEC, DIN and UL.
IEC BUSSBAR FUSE SYSTEM CONTRACTOR PRODUCTS

comprehensive

range

of

circuit
HIGH SPEED FUSES HIGH VOLTAGE PRODUCTS

protection solutions fused and non-fused.

CFS - 2004

HIGH SPEED FUSES

HIGH VOLTAGE PRODUCTS

Cooper Bussmann Cooper (UK) Limited Burton-on-the-Wolds Leicestershire LE12 5TH UK Telephone: 44 (0)1509 882 737 Facsimile : 44 (0)1509 882 786 http://www.bussmann.com

Your Representative

Cooper Bussmann 2002. Printed January 2004


A Industries Company.

IEC CYLINDRICAL FUSE SYSTEM ISO-SIGMA


energia e gesto lda

European Domestic and Industrial Fuse Links


The Bussmann range of European cylindrical fuse links are available in a broad selection of physical sizes and current ratings for applications where the system voltage is 250, 380, 400, 500 & 690 Volts AC. A range of product is available for domestic applications. These are also available with an optional visual indicator. Fuse links comply with IEC60269-1, 60269-3, 60269-3-1 and also meet the requirements of NF and UNE standards. Class gL-gG and aM fuse links are intended for industrial applications. All industrial fuse links are available with an operated visible fuse indicator. Sizes 14x51 & 22x58 in both Class gL-gG and aM are also available with a built-in striker for micro-switch operation and remote indication. All Cooper Bussmann cylindrical fuse links have ceramic bodies and silverplated copper end caps.

Domestic & Industrial Modular Fuse Holders


The CH range of modular fuse holders is designed to accommodate European domestic and industrial fuse links. Products meet the requirements of IEC60269 and 60947-3 as well as complying with the requirements of NF & UNE standards. Most configurations are available in multiple pole configurations and offer IP20 finger-safe protection. An optional LED is available for domestic and industrial modular fuse holders for open circuit indication. Multi-phase connection accessories are also available. 10x38 products (1, 2 & 3 Pole with and without indication) are UL listed and CSA certified. Size 14x51 & 22x58 fuse holders (1, 2 & 3 Pole ONLY) are UL recognised. 14x51 & 22x58 designs are available with a micro-switch attachment for operated fuse indication (when using fuse links with a striker) and with pre-breaking or fuse presence. Please contact Cooper Bussmann for more information. All Cooper Bussmann domestic and industrial modular fuse holders are manufactured from self-extinguishable polyester material and carry a V0 flammability rating.

For more information visit our website at www.bussmann.com

EUROPEAN DOMESTIC FUSE LINKS - CLASS gG ISO-SIGMA


energia e gesto lda
Quantity per Pack: 10 pcs

6X23

Rated Current
2 4 6 10

Part Number Without Indicator


CD0623G2 CD0623G4 CD0623G6 CD0623G10

Part Number With Indicator


-

Voltage (AC)

Breaking Capacity (kA)

250V

6 kA

8X23

Rated Current
2 4 6 10 16

Part Number Without Indicator


CD0823G2 CD0823G4 CD0823G6 CD0823G10 CD0823G16

Part Number With Indicator


CD0823G2 I CD0823G4 I CD0823G6 I CD0823G10 I CD0823G16 I

Voltage (AC)

Breaking Capacity (kA)

250V

6 kA

10X25

Rated Current
6 10 16

Part Number Without Indicator


CD1025G6 CD1025G10 CD1025G16

Part Number With Indicator


CD1025G6 I CD1025G10 I CD1025G16 I

Voltage (AC)

Breaking Capacity (kA)

250V

6 kA

Rated Current
0.5 1 2 4 6 8 10 12 16 20 25

Part Number Without Indicator


CD0831G0.5 CD0831G1 CD0831G2 CD0831G4 CD0831G6 CD0831G8 CD0831G10 CD0831G12 CD0831G16 CD0831G20 CD0831G25

Part Number With Indicator


CD0823G2 I CD0823G4 I CD0823G6 I CD0831G8 I CD0823G10 I CD0831G12 I CD0823G16 I CD0831G20 I CD0831G25 I

Voltage (AC)

Breaking Capacity (kA)

8X31

400V

20 kA

10X38 10X31

Rated Current
16 20 125

Part Number Without Indicator


CD1031G16 CD1031G20 CD1031G25

Part Number With Indicator


CD1031G16 I CD1031G20 I CD1031G25 I

Voltage (AC)

Breaking Capacity (kA)

400V

20 kA

Rated Current
25 32

Part Number Without Indicator


CD1038G25 CD1038G32

Part Number With Indicator


CD1038G25 I

Voltage (AC)
400V

Breaking Capacity (kA)


20 kA

CD1038G32 I

Rated Current
2 4 6 10 16 20 25 32

Part Number Without Indicator


CD0836G2 CD0836G4 CD0836G6 CD0836G10 CD0836G16 CD0836G20 CD0836G25 CD0836G32

Part Number With Indicator


CD0836G2 I CD0836G4 I CD0836G6 I CD0836G10 I CD0836G16 I CD0836G20 I CD0836G25 I CD0836G32 I

Voltage (AC)

Breaking Capacity (kA)

8X36

400V

20 kA

For more information visit our website at www.bussmann.com

INDUSTRIAL CYLINDRICAL FUSE LINKS - CLASS gG/gL ISO-SIGMA


energia e gesto lda
Quantity per Pack: 10 pcs

Rated Current
0.5 1 2 4 6 8 10 12 16 20 25

Part Number Without Indicator


C08G0.5 C08G1 C08G2 C08G4 C08G6 C08G8 C08G10 C08G12 C08G16 C08G20 C08G25

Part Number With Indicator


C08G0.5I C08G1I C08G2I C08G4I C08G6I C08G8I C08G10I C08G12I C08G16I C08G20I C08G25I

Watts Loss (W)


2.60 2.50 0.70 0.85 0.95 1.55 1.65 2.00 2.30 2.55 2.65

Voltage (AC)

Breaking Capacity (kA)

8X31

400V

20 kA

Rated Current
0.5 1 2 4 6 8 10 12 16 20 25 32

Part Number Without Indicator


C10G0.5 C10G1 C10G2 C10G4 C10G6 C10G8 C10G10 C10G12 C10G16 C10G20 C10G25 C10G32

Part Number With Indicator


C10G0.5I C10G1I C10G2I C10G4I C10G6I C10G8I C10G10I C10G12I C10G16I C10G20I C10G25I C10G32I

Watts Loss (W)


1.43 2.77 0.60 0.70 0.85 0.75 1.00 1.30 1.60 2.00 2.60 2.90

Voltage (AC)

Breaking Capacity (kA)

10X38

500V

120 kA

400V

Rated Current
1 2 4 6 8 10 12 16 20 25 32 40 50

Part Number Without Indicator


C14G1 C14G2 C14G4 C14G6 C14G8 C14G10 C14G12 C14G16 C14G20 C14G25 C14G32 C14G40 C14G50

Part Number With Indicator


C14G1I C14G2I C14G4I C14G6I C14G8I C14G10I C14G12I C14G16I C14G20I C14G25I C14G32I C14G40I C14G50I

Watts Loss (W)


3.90 0.90 1.00 1.15 1.00 1.30 1.70 2.00 2.50 3.30 3.50 4.85 4.90

Voltage (AC)

Breaking Capacity (kA)

690V

80 kA

14X51

500V 400V

120 kA

Rated Current
2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125

Part Number Without Indicator


C22G2 C22G4 C22G6 C22G8 C22G10 C22G12 C22G16 C22G20 C22G25 C22G32 C22G40 C22G50 C22G63 C22G80 C22G100 C22G125

Part Number With Indicator


C22G2I C22G4I C22G6I C22G8I C22G10I C22G12I C22G16I C22G20I C22G25I C22G32I C22G40I C22G50I C22G63I C22G80I C22G100I C22G125I

Watts Loss (W)


1.00 1.10 1.30 1.10 1.50 1.80 2.10 2.70 3.60 3.70 4.50 5.20 6.90 7.80 8.60 11.40

Voltage (AC)

Breaking Capacity (kA)

690V

80 kA

22X58

500V 400V 120 kA

For more information visit our website at www.bussmann.com

INDUSTRIAL CYLINDRICAL FUSE LINKS - CLASS aM ISO-SIGMA


energia e gesto lda
Quantity per Pack: 10 pcs

Rated Current
1 2 4 6 8 10 12 16 20 25

Part Number Without Indicator


C08M1 C08M2 C08M4 C08M6 C08M8 C08M10 C08M12 C08M16 C08M20 C08M25

Part Number With Indicator


C08M1I C08M2I C08M4I C08M6I C08M10I C08M12I C08M16I C08M20I -

Watts Loss (W)


0.11 0.14 0.25 0.28 0.43 0.45 0.50 0.55 0.58 0.62

Voltage (AC)

Breaking Capacity (kA)

8X32

400V

20 kA

Rated Current
0.16 0.25 0.5 1 2 4 6 8 10 12 16 20 25 32

Part Number Without Indicator


C10M0.16 C10M0.25 C10M0.5 C10M1 C10M2 C10M4 C10M6 C10M8 C10M10 C10M12 C10M16 C10M20 C10M25 C10M32

Part Number With Indicator


C10M1I C10M2I C10M4I C10M6I C10M8I C10M10I C10M12I C10M16I C10M20I C10M25I C10M32I

Watts Loss Voltage (AC) (W)


0.24 0.36 0.49 0.10 0.18 0.31 0.32 0.52 0.55 0.63 0.92 0.96 1.40 1.80

Breaking Capacity (kA)

10X38

500V

120 kA

400V

Rated Current
0.25 0.5 1 2 4 6 8 10 12 16 20 25 32 40 50

Part Number Without Indicator


C14M0.25 C14M0.5 C14M1 C14M2 C14M4 C14M6 C14M8 C14M10 C14M12 C14M16 C14M20 C14M25 C14M32 C14M40 C14M50

Part Number With Indicator


C14M1I C14M2I C14M4I C14M6I C14M8I C14M10I C14M12I C14M16I C14M20I C14M25I C14M32I C14M40I C14M50I

Watts Loss (W)


0.41 0.69 0.14 0.24 0.45 0.42 0.70 0.53 0.88 1.16 1.23 1.46 2.04 3.34 304

Voltage (AC)

Breaking Capacity (kA)

690V

80 kA

14X51

500 400

120 kA

Rated Current
2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125

Part Number Without Indicator


C22M2 C22M4 C22M6 C22M8 C22M10 C22M12 C22M16 C22M20 C22M25 C22M32 C22M40 C22M50 C22M63 C22M80 C22M100 C22M125

Part Number With Indicator


C22M2I C22M4I C22M6I C22M8I C22M10I C22M12I C22M16I C22M20I C22M25I C22M32I C22M40I C22M50I C22M63I C22M80I C22M100I C22M125I

Watts Loss (W)


0.29 0.48 0.47 0.73 0.74 0.83 1.21 1.29 1.53 2.13 3.40 3.48 4.46 5.86 6.61 8.42

Voltage (AC)

Breaking Capacity (kA)

690V

80 kA

22X58

500V 400V 120 kA

For more information visit our website at www.bussmann.com

INDUSTRIAL CYLINDRICAL FUSE LINKS WITH STRIKER ISO-SIGMA


energia e gesto lda

Class gG/gL with Striker


Rated Part No Current With Striker
2 4 6 8 10 12 16 20 25 32 40 50 C14G2S C14G4S C14G6S C14G8S C14G10S C14G12S C14G16S C14G20S C14G25S C14G32S C14G40S C14G50S

Quantity per Pack: 10 pcs


Watts Loss (W)
0.24 0.45 0.42 0.70 0.53 0.88 1.16 1.23 1.46 2.04 3.34 3.04

Voltage (AC)

Breaking Capacity (kA)

14X51

500V

120 kA

400V

Rated Part No Current With Striker


4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 C22G4S C22G6S C22G8S C22G10S C22G12S C22G16S C22G20S C22G25S C22G32S C22G40S C22G50S C22G63S C22G80S C22G100S C22G125S

Watts Loss (W)


0.48 0.47 0.73 0.74 0.83 1.21 1.29 1.53 2.13 3.40 3.48 4.46 5.86 6.61 8.42

Voltage (AC)

Breaking Capacity (kA)

690V

80 kA

22X58

500V 400V

120 kA

Class aM with Striker


Rated Part No Current With Striker
1 2 4 6 8 10 12 16 20 25 32 40 50 C14M1S C14M2S C14M4S C14M6S C14M8S C14M10S C14M12S C14M16S C14M20S C14M25S C14M32S C14M40S C14M50S

Quantity per Pack: 10 pcs


Watts Loss (W)
0.14 0.24 0.45 0.42 0.70 0.53 0.88 1.16 1.23 1.46 2.04 3.34 3.04

Voltage (AC)

Breaking Capacity (kA)

14X51

500V

120 kA

400V

Rated Part No Current With Striker


2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 C22M2S C22M4S C22M6S C22M8S C22M10S C22M12S C22M16S C22M20S C22M25S C22M32S C22M40S C22M50S C22M63S C22M80S C22M100S C22M125S

Watts Loss (W)


0.29 0.48 0.47 0.73 0.74 0.83 1.21 1.29 1.53 2.13 3.40 3.48 4.46 5.86 6.61 8.42

Voltage (AC)

Breaking Capacity (kA)

690V

80 kA

22X58

500V 400V 120 kA

For more information visit our website at www.bussmann.com

MODULAR FUSE HOLDER DATA TABLES ISO-SIGMA


energia e gesto lda

Domestic Modular Fuse Holders


Size
8x23 10x25 8x31 10x31 10x38 Neutral 8x23 10x25 8x31 10x31 10x38

Configuration

Fuse Holder Part Number Without Indication With Indication


CHD8231D CHD10251D CHD8311D CHD10311D CHD1038D CHDND CHD8231DN CHD10251DN CHD8311DN CHD10311DN CHD10381DN CHD8231D I CHD10251D I CHD8311D I CHD10311D I CHD1038D I CHDND I CHD8231DN I CHD10251DN I CHD8311DN I CHD10311DN I CHD1038DN I

No. of 17.5mm Modules


1 1 1 1 1 1 1 1 1 1 1

Max. Current
10 16 20 25 32 32 10 16 20 25 32

Max. Voltage
250 250 400 400 400 400 250 250 400 400 400

Box Quantity
12 12 12 12 12 12 12 12 12 12 12

1 Pole

1 Pole + Neutral

Industrial Modular Fuse Holders


Size Configuration
1 1 1 1 2 3 3 3 4 1 1 1 1 2 3 3 3 4 1 1 1 2 3 3 4 1 1 1 2 3 3 4 Pole Neutral Pole Pole + Neutral Pole + Neutral Pole Pole Pole + Neutral Pole + Neutral Pole Pole Neutral Pole Pole + Neutral Pole + Neutral Pole Pole Pole + Neutral Pole + Neutral Pole Pole Neutral Pole Pole + Neutral Pole Pole Pole + Neutral Pole Pole Neutral Pole Pole + Neutral Pole Pole Pole + Neutral Pole

Fuse Holder Part Number Without Indication With Indication


CH081D CH081DNX CH081DNS CH081DN CH082D CH083D CH083DNS CH083DN CH084D CHM1D CHM1DNX CHM1DNS CHM1DN CHM2D CHM3D CHM3DNS CHM3DN CHM4D CH141D CH141DNX CH141DN CH142D CH143D CH143DN CH144D CH221D CH221DNX CH221DN CH222D CH223D CH233DN CH224D CH081DI CH081DNSI CH081DNI CH082DI CH083DI CH083DNSI CH083DNI CH084DI CHM1DI CHM1DNSI CHM1DNI CHM2DI CHM3DI CHM3DNSI CHM3DNI CHM4DI CH141DI CH141DNI CH142DI CH143DI CH143DNI CH144DI

No. of 17.5mm Modules


1 1 1 2 2 3 3 4 4 1 1 1 2 2 3 3 4 4 1.5 1.5 3 3 4.5 6 6 2 2 4 4 6 8 8

Max. Current

Max. Voltage

Box Quantity
12 12 12 6 6 4 4 3 3 12 12 12 6 6 4 4 3 3 6 6 3 3 2 1 1 6 6 3 3 2 1 1

8 x 31

25A

400Vac

10 x 38

32A

690Vac

14 x 51

50A

690Vac

22 x 58

Not Available with Indication

125A

690Vac

Solid Neutral Links

Part Number
C8NL C10NL C14NL C22NL

For Use in Fuseholder Type


CH08 CHM CH14 CH22 Series Series Series Series

Pack Quantity
10pcs 10pcs 10pcs 10pcs

For more information visit our website at www.bussmann.com