You are on page 1of 48

Residential

Products and Applications


AP_1211 December 2011

Bathroom Exhaust Range Hood Exhaust Clothes Dryer Boosting Garage Ventilation Indoor Air Quality (IAQ)

Featuring Vent Lights and Premium Grilles


The Worlds Leading Producer of Air Movement Products
1

Residential Ventilation Concerns...

SOLVED!

S&P, the worlds leading producer of air movement products, offers a full selection of fan solutions for all of your residential ventilation requirements. Inline remote fans are the most effective way to vent todays homes and do so with less noise, better air flow and are both affordable and aesthetically appealing (the fan is hidden). In addition, S&P offers more solutions with multiple fan choices to meet all your requirements. Whatever your requirements... S&P has a solution.

Bathroom Exhaust...pg 19-35

Range Hood Exhaust...pg 36-39

Clothes Dryer Boosting...pg 40

Garage Ventilation...pg 41

IAQ...pg 36-39

Fans Fans ans a s for f Life! Life e!

Look for our Fans for Life symbol We certify the fans that bear this symbol offer the lowest possible energy use and running costs, while still providing the highest possible performance.

Fan Options Guide


This Ventilation Options Guide is designed to help you choose with S&P fan is perfect for your requirements. S&P fan Recommendations
Mounting Locations Impeller Certifications Type

ENERGY STAR

Mixed Flow

Centrifugal

Inline/Duct

Model TD-MIXVENT

CFM Range (at 0 SP)

Sidewall

Ceiling

HVI

UL

x
TD-SILENT

x x x

Economical Concerns 91-1050 and Most Applications Extreme Noise Concerns Extreme High Static Pressure Concerns

Bathroom Range Hood Garage Bathroom Range Hood Garage Bathroom Range Hood Clothes Dryer Garage Bathroom Clothes Dryer Garage

x
PV-POWERVENT

x x x

108-530

x
SWF-SIDEWALL

x x x x

108-942

x
V-SERIES

x x

108-491

Limited Access to duct

x
TR-SERIES

x x x x

31-150

Traditional bathroom needs

Bathroom

x x x x

46-310

IAQ Concerns

Bathroom* IAQ

*See IAQ Applications (page 40) for information on using the TR-Series for Bathroom Exhaust

Applications

PV-POWERVENT SERIES

Technical Specifications
Warranty Five (5) year limited warranty. Range All twelve (12) PV model sizes (PV 100, 100x, 125, 125x, 150, 150x, 200, 200x, 250, 250x, 315 and 315x) include the following specifications: Casing Manufactured from high grade pressed galvanized steel, with black baked enamel coating. Extra long inlet and discharge collars make installation quick and trouble free. Supplied with a strong galvanized steel mounting bracket. Supplied with a prewired junction box. Wheel / Impeller Backward curved centrifugal type constructed of metal. Factory matched to an external rotor motor and dynamically balanced to eliminate vibration. Accessories A wide range of accessories is available to complete the most demanding installation. Motor Totally enclosed permanent split capacitor start and run external rotor motors. 115V 60Hz (single phase) electrical connection. Permanently sealed, self lubricating precision ball bearings. Safety Thermal Overload Protection Cut-Out (Automatic Reset Type). All Models are suitable for working airstreams up to 140 F Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed. Independently safety tested by Intertek Laboratories, and are ETL Listed. Independently tested for Airflow Performance. The PV range is licensed to bear the AMCA seal for Air Performance. The PV product range is certified by the Home Ventilating Institute (HVI) for Air Performance. PV-150x and larger are ENERGY STAR qualified. All models are NAHB - National Green Building Green Approved.

PV-POWERVENT SERIES
Dimensional Data
A

Dimensions (inches/mm)

Model PV-100 PV-100x


D

Weight lbs(kgs)

313/16 313/16 43/4 711/16 71/2 43/4 99/16 7 97.5 97.5 120 196 190 120 243 313/16 313/16 43/4 711/16 71/2 43/4 99/16 7 97.5 97.5 120 196 190 120 243 413/16 413/16 43/4 713/16 71/2 43/4 99/16 7 122.5 122.5 120 198 190 120 243 413/16 413/16 43/4 713/16 71/2 43/4 99/16 7 122.5 122.5 120 198 190 120 243 513/16 147 513/16 147 713/16 198 713/16 198 93/4 248 93/4 248 93/4 248 93/4 248 43/4 120 713/16 198 43/4 120 713/16 198 43/4 120 513/16 147 43/4 120 83/4 223 513/16 147 43/4 120 43/4

3.0 3.0 3.0 3.0

PV-125 PV-125x PV-150

87/16 95/16 43/4 131/8 11 120 214 236 120 334 5.0 87/16 95/16 43/4 131/8 11 214 236 120 334 5.0 83/4 223 95/16 43/4 131/8 11 236 120 334 5.0 95/16 43/4 131/8 11 236 120 334 5.0

B E

PV-150x PV-200 PV-200x


F

PV-250 PV-250x

81/16 95/16 43/4 131/8 13 205 236 120 334 6.0 81/16 95/16 43/4 131/8 13 205 236 120 334 6.0

PV-315 PV-315x

125/16 43/4 93/16 109/16 43/4 1513/16 21 125/16 312 312 120 233 269 120 401 10.0 125/16 125/16 43/4 93/16 109/16 43/4 1513/16 21 312 312 120 233 269 120 401 10.0

Technical Data
Air Performance
Trade Name Model No. Nom. RPM Volts Max. Watts CFM v Static Pressure (SP) Ins. WG 0 0.125 0.25 0.375 0.5 0.75 1.0 1.25 1.5 Max. SP Duct Dia. Ins.

Power Vent-100 Power Vent-125 Power Vent-150 Power Vent-200 Power Vent-250 Power Vent-315

PV-100 PV-125 PV-150 PV-200 PV-250 PV-315

1400 2880 2350 2745 2750 2700 3100 2930 3000 3045 2600 2650

115 115 115 115 115 115 115 115 115 115 115 115

57 84 58 85 78 130 130 180 200 214 170 370

108 153 128 206 245 390 402 544 587 618 654 942

100 142 104 190 205 367 375 515 555 595 605 905

92 130 85 170 177 340 350 485 525 570 570 859

85 120 74 153 157 312 327 446 495 540 525 811

78 111 63 135 129 285 296 415 472 510 487 762

66 96 47 110 93 233 239 360 412 450 408 622

52 80 32 88 59 193 179 312 355 390 333 508

33 63 15 62 153 135 273 312 340 265 440

18 34 33 110 85 230 270 297 203 390

1.7 1.85 1.43 1.77 1.2 2.05 1.94 2.64 2.61 2.8 2.21 3.9

4 4 5 5 6 6 8 8 10 10 12.4 12.4

Power Vent-100x PV-100x Power Vent-125x PV-125x Power Vent-150x PV-150x Power Vent-200x PV-200x Power Vent-250x PV-250x Power Vent-315x PV-315x

Performance certified is for installation type D-Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM or RPS) shown is nominal. Performance is based on actual speed of test.

Soler & Palau USA certifies that the PV range shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

The PV-POWERVENT Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.

*PV 150x and larger ENERGY STAR qualified

Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.
5

SWF-SIDEWALL SERIES

Technical Specifications
Warranty Five (5) year limited warranty. Range All five SWF models sizes (SWF 100, 100x, 150, 150x & 200) include the following specifications: Casing Manufactured from high grade pressed galvanized steel, with baked enamel coating. Removable top for easy access to motor for cleaning or inspection. Large grille opening for easy passing of lint and other potentially clogging materials. Includes prewired terminal box. Wheel/Impeller Backward curved centrifugal type. Factory matched to an external rotor motor and dynamically balanced to eliminate vibration. Accessories A wide range of accessories is available to complete the most demanding installation. Motors Totally enclosed permanent split capacity start and run external rotor motors. 115V 60Hz (single phase) electrical connection. Permanently sealed, self lubricating precision ball bearings. Safety Thermal Overload Protection Cut-Out (Automatic Reset Type). All models are suitable for working airstreams up to 140F. Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL listed. The SWF product range is certified by the Home Ventilating Institute (HVI) for Air Performance. All models are NAHB - National Green Building Green Approved.

SWF-SIDEWALL SERIES
Dimensional Data
A

Dimensions (inches/mm)
D

Model SWF-100 SWF-100x


13

A
1/4

B
13
1/4

C
9 228 9 228 10 10 254 11
7/16 3/16

C1
3 76 3 76 3 76 3 3/16 81 3
3/8

C2
2
7/16

D
4 100 4 100 6 150 6 150 8 200

337 13 1/4 337 15


1/2

337 13 1/4 337 13


1/4

62 2 7/16 62 2
7/16

B C1 C2

SWF-150
C

394 15 1/2 394 15


1/2

337 16 1/16 408 16


1/16

256

62 2 7/16 62 2
7/16

SWF-150x SWF-200

394

408

290

87

62

Technical Data
Air Performance
Model SWF-100 SWF-100X SWF-150 SWF-150X SWF-200 CFM v Static Pressure (SP) Ins. WG 0 108 153 250 369 491 0.125 92 135 215 247 445 0.25 79 127 185 315 417 0.375 64 117 157 293 383 0.5 50 104 133 258 346 0.75 27 80 93 205 282 1.0 11 55 55 157 220 1.25 25 24 109 160 1.5 62 105

The SWF-SIDEWALL Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.

Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.

General Details of the TD-MIXVENT Range


Low profile mixed flow fans, manufactured in plastic material (up to model 200) or in galvanized steel sheet protected with Epoxy paint (model 250 and 315), with external terminal box, removable motor-impeller assembly and adjustable single-phase motor, Class B, IP44.

Construction characteristics
Polypropylene housing Steel housing with epoxy coating ABS fan blades Aluminum fan blades Thermal link via fuse Thermal link with automatic reset Permanently lubricated ball bearings Speed controllable 2-speed motor 100 100x 125 150 200 250 315

The extensive range of the TD-MIXVENT series makes it an effective solution for a wide range of residential and light commercial ventilation installations.

TD-MIXVENT Installation & Maintenance


Low Profile

The low profile of the fans in the TD-MIXVENT range makes them the ideal product for installations with low height limits, such as the case of suspended ceilings.

Easy to Install

Secure the support.

Make the connections.

Connect the ducts.

Flexibility in Location
Option 2

Easy Maintenance

Option 1

Removable body, for repair or cleaning, without the need to touch the ducts.

The fans can be connected at any point along the ventilation duct: along the duct or at the end. 9

TD-MIXVENT SERIES
Technical Specifications
Warranty Five (5) year limited warranty.

Range The TD-MIXVENT series consists of seven (7) nominal sized in-line fans. All models are specifically designed for direct connection in-line with industry standard diameter round ducting. Construction The TD-MIXVENT models 100, 100x, 125,150, and 200 are manufactured in tough reinforced plastic, models 250 and 315 have a metal casing and are finished in a tough epoxy-polyester paint coating. The TD fan duct connection flanges are manufactured from reinforced plastic, except for models 200, 250 and 315 which are constructed from epoxy-polyester coated metal. Impellers The impeller blades for models 100, 100x, 125, 150 and 200 are molded in tough ABS plastic. Models 250 and 315 are metal. Motors Models 100, 100x and 125 : Single-phase, 120V 60Hz, shaded pole induction asynchronous motor in die cast aluminum. All motors include direct two speed connection and are also suitable for voltage speed control. Class ll electrical insulation (model 100) & Class l (models 100x and 125) IP 44 Protection Class B Motor Insulation Safety auto reset Thermal Overload Protection (fuse type) Self-lubricating sleeve bearings. Suitable for working airstreams up to 104 F (40C). Models 150, 200, 250 and 315: Single-phase induction asynchronous motor, with permanent capacitor and external rotor constructed of die cast aluminum. Models 150, 200 and 315 include direct two speed connection and are also suitable for voltage speed control. Class I electrical insulation IP 44 Protection Thermal Overload Protection Class B Motor Insulation Sealed For Life, ball bearings Suitable for working airstreams up to 140 F (60C). Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed. Independently tested for Airflow Performance. The PV range is licensed to bear the AMCA seal for Air Performance. The TD product range is certified by the Home Ventilating Institute (HVI) for Air Performance. All models are ENERGY STAR qualified. All models are NAHB - National Green Building Green Approved.
10

TD-MIXVENT SERIES
Dimensional Data
Dimensions (inches/mm)
Model TD-100 TD-100x TD-125 TD-150 TD-200 TD-250 TD-315
5 7 7 8

X
15/16

A
9
1/8

B
5
7/16

C
3 4 4 5 127 5 9/16 141 7 9/16 192 8 13/16 224
3/4

D
3
7/8

E
3
1/4

F
3
3/4

G
1
7/8

H
2 2 2 2
1/16

151
3/8

232 11 15/16 303 10 3/16 258 5/8 11 295 11 7/8 302 15 3/16 386 17 11/16 450 6

138
15/16 1/2

96 3 115
1/2

98
13/16

82 3
15/16

95 3
9/16

48 3 3 3
1/8

52
3/8

188
3/8

176 6 15/16 176 7/8 7 200 8 9/16 217 10 11/16 272 13 1/4 336

97 4 13/16 123 13/16 5 147 7 13/16 198 9 3/4 248 12 5/16 312

100 3 15/16 100 7/16 4 112 4 7/8 124 6 1/8 155 7 3/8 188

90 3 9/16 90 1/8 5 130 5 1/2 140 6 5/8 168 8 1/4 210

80
1/8

60
3/8

188
3/8

115

80
1/8

60
3/8

212 9 3/16 233 11 7/16 291 14 356

60 3 15/16 3 11/16 100 94 5 11/16 5 1/2 145 140 7 3/16 7 182 178

80

Technical Data
Air Performance
Model Nom. RPM 2431 2516 1556 2096 1633 2146 1709 2289 2322 2781 2400 3200 2000 2500 Volts 120 120 120 120 120 120 120 120 120 120 115 115 115 115 Max. Watts 23 26 20 33 24 38 54 65 139 184 162 241 208 335 Speed LS HS LS HS LS HS LS HS LS HS LS HS LS HS CFM v Static Pressure (SP) Ins. WG 0 97 101 100 135 149 197 218 293 476 538 541 754 751 1050 0.125 81 85 77 113 110 168 193 273 422 495 475 715 670 990 0.25 51 57 48 90 73 133 163 250 373 458 418 680 545 932 0.375 53 86 128 227 317 418 355 640 420 850 0.5 22 105 206 260 367 295 606 285 770 0.75 24 131 40 190 218 520 190 600 1.0 35 10 170 405 130 420 Max. SP .4 .4 .375 .55 .35 .55 .8 1.15 1.38 1.625 2.03 2.53 1.62 2.95 Duct Dia. Ins. 4 4 4 4 5 5 6 6 8 8 10 10 12.4 12.4

TD 100

TD 100x

TD 125

TD 150

TD 200

TD 250

TD 315

Performance certified is for installation type D-Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM or RPS) shown is nominal. Performance is based on actual speed of test.

LS= Low Speed HS=High Speed

Soler & Palau USA certifies that the TD range shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

The TD-MIXVENT Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.

Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.

11

General Details of the TD-SILENT Range


As the name suggests these fans are extremely quiet, low profile Mixed-flow fans. Manufactured in plastic material with an external connection box, the body is easily dismantled with a two speed controllable 115V 60Hz motor. Sound waves are directed through the perforated inner skin and absorbed by a layer of sound-absorbent insulation. Plus the TD-SILENT is fitted with rubber gaskets on the inlet and outlet to absorb vibrations. Construction characteristics
Polypropylene housing ABS fan blades Thermal link with automatic reset Permanently lubricated ball bearings Speed controllable 2-speed motor 100XS 150S 200S

Terminal Box Sound Attenuating Liner

Rubber Gasket

Support Brackets

Sound-absorbent cover External Casing Mounting Bracket


12

TD-SILENT Innovative Design Features


Low Profile Low Noise Levels

The low profile of the fans in the TDSILENT range makes them the ideal product for installations with low height limits, such as the case of suspended ceilings.

Sound waves produced inside the TD, are directed through the perforated inner skin and absorbed by the layer of soundabsorbent material.

Easy Maintenance

Connection Box Rotates 360

Bi-material support brackets, which in addition to simplifying installation, serve as joint seals.

Connection box can be rotated 360, to facilitate easy connection of the power cable.

Duct Air-Seals

Integral Mounting Bracket

Bi-material inlet and outlet incorporating a flexible washer to facilitate installation, absorb vibrations and provide a virtually air-tight seal.

Mounting bracket for installing on a wall or ceiling, incorporating twin-material support brackets for the motor section that absorbs vibration.

13

TD-SILENT Easy Installation

Loosen the clamps.

Open the clamps on both ends.

Remove the fan body.

Remove the terminal box lid.

Connect electrical supply.

Re-mount fan body by tightening the clamps.

14

TD-SILENT SERIES
Technical Specifications
Warranty Five (5) year limited warranty.

Range The TD-SILENT consists of four (4) nominal sized in-line fans. All models are specifically designed for direct connection in-line with industry standard diameter round ducting. Construction The TD-SILENT models 100XS (4 or 5), 150S and 200S are manufactured in tough reinforced plastic. Sound waves are directed through the perforated inner skin and absorbed by a layer of sound-absorbent insulation. Plus the TD-SILENT is fitted with rubber gaskets on the inlet and outlet to absorb vibrations. Impellers The impeller blades are molded in tough ABS plastic. Motors Models 100XS: Single-phase, 120V 60Hz, shaded pole induction asynchronous motor in die cast aluminum. All motors include direct two speed connection and are also suitable for voltage speed control. Class l electrical insulation IP 44 Protection Class B Motor Insulation Safety auto reset Thermal Overload Protection (fuse type) Self-lubricating sleeve bearings. Suitable for working airstreams up to 104 F (40C). Models 150S and 200S: Single-phase induction asynchronous motor, with permanent capacitor and external rotor in die cast aluminum. All models include direct two speed connection and are also suitable for voltage speed control. Suitable for working airstreams up to 140 F (60C). Class I electrical insulation IP 44 Protection Thermal Overload Protection Class B Motor Insulation Sealed For Life, ball bearings Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed. Independently tested for Airflow Performance. The TD product range is certified by the Home Ventilating Institute (HVI) for Air Performance. All models are ENERGY STAR qualified. All models are NAHB - National Green Building Green Approved.
15

TD-SILENT SERIES
Air Performance
All models include a direct two speed motor connection.
Model Duct Dia. Ins. Nom. RPM Volts Max. Watts Speed CFM v Static Pressure (SP) Ins. WG 0 0.125 0.25 0.375 0.5 0.75 1.0 Max. SP Max operating temp. (F) Wgt. (lbs)

4 TD-100XS 4 5 5 TD-150S TD-200S 6 6 8 8

2000 2500 2000 2500 2200 2700 2000 2200

120 120 120 120 120 120 120 120

21 35 21 36 55 65 115 122

LS HS LS HS LS HS LS HS

108 143 147 203 239 333 409 530

82 121 110 175 209 315 367 503

48 91 63 138 181 286 333 472

59 84 154 271 306 443

23 33 120 257 271 415

62 178 183 349

77 46 204

0.4 0.6 0.4 0.6 0.95 1.2 1.2 1.2

104 104 104 104 140 140 140 140 13.2 19.2 11.9

The TD-SILENT Models 100XS and 150S are California Title 24 compliant and meet ASHRAE 62.2 when installed with a CVC and other TD models are compliant when installed with a 3 way switch and remotely mounted speed control.

Dimensions (inches)

Model TD-100XS TD-150S TD-200S

22 5/8 19 1/16 22 3/8

3 13/16 5 13/16 7 13/16

9 15/16 10 13/16 12 7/8

8 1/16 8 11/16 10 3/8

3 15/16 9 13/16 4 9/16 5 11/16 9 13/16 13 3/8

3 1/4 3 3/4 5 1/16

4 3/4 5 1/4 6 7/16

16

V-CEILING MOUNT BATHROOM FAN


Performance The most energy efficient line of ceiling mounted ventilation fans available in North America. Aerodynamically engineered to move air with lowest power consumption and sound levels. Motors operate with the lowest heat build up for long life even when run continuously - 5 year warranty. Low air leakage dampers minimize uncontrolled infiltration. The lowest carbon footprint of leading residential ventilation brands. Construction Robust steel housing and duct collar Heat-sink motor unit Internal electrical wiring box Attractive, sturdy grille Impedance and thermal fuse electrical protection UL List for installation in tub/shower enclosures when connected to a GFCI protected branch circuit.

Performance Model V50 V80 V110 V150 CFM 50/31 80/60 110/93 150/110 Static Pressure (in W.G.) 0.1/0.25 0.1/0.25 0.1/0.25 0.1/0.25 Energy Efficiency Watts (CFM/Watts)* 4.5 12.9 5.1 16.1 4.6 24.2 4.5 32.7 Power (V/Hz) 120/60 120/60 120/60 120/60 Sones <0.3 <0.3 0.8 <0.3 Amps 0.12 0.15 0.21 0.29

* Energy Star qualified data based on tested air flow and power consumption.

Dimensions Duct Model Dia. V50 V80 V110 V150 4 4 4 6 Grille Size (Sq.) Cabinet Size W H D 8-1/16 8-1/16 8-1/16 9-9/16 Unit Wgt./ Ship Wgt. (lbs) 7.7/10.4 7.7/10.4 7.7/10.4 12.3/16.2

13 x 13 9-7/8 9-7/8 13 x 13 9-7/8 9-7/8 13 x 13 9-7/8 9-7/8 13-5/8 x 13-5/8 12-1/16 12-1/16

17

TR-TOTAL RECOVERY FOR ALL CLIMATES


Contractor Benefits

Standard Features MERV-8 filters Less than 1 watt stand-by power consumption Transformer/relay package allowing simple on/off control Plastic double collars for 6 or 8 direct duct connection (TR300 is 8 only) 3 power cord Integral mounting flange and hanging bracket system Fully insulated case Large cores for high efficiency No condensate pan or drain required 10-year industry best core warranty 2-year warranty on balance of unit
LISTED

Models compatible to any HVAC equipment Simple installation Mount in any orientation May be installed in unconditioned locations like attics and garages Easy-to-access field support Elimination of callbacks Green Building compliant

Performance and Dimensions


Model ESP (Inches H2O) Airflow (CFM) 0.1 86 99 71 64 49 148 138 67 57 41 207 185 76 67 52 0.2 73 95 74 68 53 141 132 68 59 43 192 169 77 68 52 0.3 59 90 78 71 57 132 125 70 60 44 186 165 77 68 53 0.4 46 87 81 74 60 113 118 73 64 48 176 154 78 69 56 310 310 67 56 37 0.5 94 110 76 67 52 168 148 79 70 55 300 300 68 57 38 0.6 69 98 80 72 57 149 138 80 72 56 289 287 69 58 39

DUCTED HEAT RECOVERY VENTILATOR 89S5

0.7 52 92 83 75 60 122 128 82 74 59 268 266 71 61 42

0.8 249 247 72 62 44

0.9 199 224 76 67 48

1.0 155 206 80 70 51

Specifications
Electrical: 120 V, 60 Hz, Single Phase, 1.0 FLA, contains one 0.1 hp motor Dimensions: unit case=25-1/8W x 20-1/8H x 10-1/8D carton=21W x 29-1/2L x 15H Weight: unit=44 lbs, in carton=52 lbs Electrical: 120 V, 60 Hz, Single Phase, 1.3 FLA, contains one 0.1 hp motor Dimensions: unit case=28-3/4W x 20-1/8H x 13D, carton=21W x 32L x 17-1/2H Weight: unit=58 lbs, in carton=65 lbs Electrical: 120 V, 60 Hz, Single Phase, 1.5 FLA, contains one 0.1 hp motor Dimensions: unit case=28-3/4W x 20-1/8H x 23-7/8D carton=21-1/2W x 32L x 29H Weight: unit=80 lbs, in carton=88 lbs Electrical: 120 V, 60 Hz, Single Phase, 3.3 FLA, contains one 0.2 hp motor Dimensions: unit case=28-3/4W x 20-1/8H x 23-7/8D carton=21-1/2W x 32L x 29H Weight: unit=72 lbs, in carton=85 lbs

TR70 TR130 TR200 TR300 18

Watts Temp Eff % Total Winter % Total Summary % Airflow (CFM) Watts Temp Eff % Total Winter % Total Summary % Airflow (CFM) Watts Temp Eff % Total Winter % Total Summary % Airflow (CFM) Watts Temp Eff % Total Winter % Total Summary %

Bathroom Exhaust Concerns...

We spend hours upon hours in our bathrooms; why not make them as comfortable as possible? No more loud noisy fans that instantly alert you the moment you hit the switch. If the strongest, quietest, bathroom exhaust system is what you seek, look no further. S&P offers a range of inline fans or ceiling mounted fans that offer several advantages over traditional bathroom fans to fit exactly what you need. Our TDMIXVENT and PV-POWERVENT lines of fans are available in convenient, all inclusive kits to provide the ultimate bathroom ventilation system. Whether you choose from the popular, and exclusive, TD series bathroom exhaust kits (for single or dual venting points), or the ultra powerful PV series kits (also, in single or dual vents) for long or complicated duct runs, all S&P bath kits feature a powerful fan mounted in the attic (away from the living space). The result is a Turbo powered fan (much stronger than generally associated with bathroom exhaust) and yet a peacefully quiet operation. If your concern is noise, the TDSILENT is the fan for you, with a built in sound attenuator and remote mounting the TD-SILENT is the fan you will never hear. You also have the choice of the SWF sidewall series fan, featuring the powerful PV motor, when attic space or easy indoor access is difficult or not suitable for traditional in-line mounting. Finally, if a ceiling mounted fan is what you need, our V-Series bathroom fans, are the most energy efficient line of ceiling mounted ventilation fans available in North America. Our remote mounted fans are powerful enough to vent multiple areas with one unit (dual vent - dv kits) for todays larger bathrooms; venting multiple bathrooms with one unit is also possible. The remote mounting feature allows peace and quiet in the living space, thus reducing the sound level of a generally noisy fan. S&P remote fans also offer extended duty times, are low maintenance and help reduce moisture, which decreases the likelihood of mold or mildew. Plus, they do not detract from the homes aesthetics unlike some unsightly roof mounted units. S&P remote fans are the clear choice for the strongest, quietest installation. In addition to our fans and kits, S&P offers a complete line of grilles and switches. When used in combination S&P offers the perfect solution with the most options!

Your Concern, S&Ps Solution:


Long or Complicated Duct Runs with Extreme Static Pressure Concerns

Economical Concerns and Most Bathroom Exhaust

Extreme Noise Concerns

PV-POWERVENT SERIES Limited Access to Duct

TD-MIXVENT SERIES

TD-SILENT SERIES

Climate & IAQ Concerns

SWF-SIDEWALL SERIES or V-SERIES

TR-SERIES
19

Bathroom

SOLVED!

Economical Bathroom Ventilation - TD-MIXVENT


2 speed motors allow for 2 performance levels with each unit (100% variable speed). Easy access to motor without dismounting the fan unit. Easy to install. Attractive all inclusive kits available. 5 year warranty. ENERGY STAR qualified. AMCA and HVI
Fans Fans ans a s for f Life! Life e!

Bathroom
20

Single Vent with TD Fan

Dual Vent with TD Fan

For the most effective bathroom ventilation, HVI recommends eight air changes per hour. Fans should be installed as close to the shower as possible and, if marked as suitable for this location, directly over it to capture the moisture as directly as possible. Your fan should have a control that will allow the fan to run at least 20 to 30 minutes after each shower. An enclosed toilet should have its own exhaust fan. Fans should be located over the shower or tub. Bathroom doors need to have at least 3/4 clearance to the finished floor to allow entry of makeup air. The Perfect Addition Using a timer or other control ensures that ventilation Need to meet ASHRAE 62.2 or continues for a minimum of 20 minutes after use of looking to continuously ventilate the bathroom. For steam showers, we recommend your bathroom? You can use a separate fan in the steam room that you can turn our CVC - Continuous Ventilation on after use. Bathroom (continuous ventilation) should be available on a continuous basis at a Control with any switch you choose! minimum of 20 CFM in lieu of an intermittent 50 (only available for use with TD fans) CFM fan.

Single Vent Bathroom Exhaust


Featuring TD-MIXVENT Kits
The TD-MIXVENT fan kits provide all the hardware needed to complete a simple in-line ducted ventilation installation. The kit includes a powerful TD in-line fan, and exterior and interior grilles (with or without lights). Available in both Standard Exhaust Kits, for venting a single location, and Deluxe (Dual) Exhaust Kits, for venting multiple locations with one fan. The TD-MIXVENT fan kit is the ideal solution for any simple in-line ducted fan installation. All TD kits have standard 7-year warranty.* Bathroom
21

Fan Sizing for Bathrooms Under 100 SQ. FT.


The following recommendations follow the Home Ventilating Institute (HVI) guidelines: FAN SIZING FOR BATHROOMS UNDER 100 Sq. Ft. The standard rule for bathrooms 100 square feet or smaller is one CFM per square foot of the bathroom. To find the square footage multiply the length of the bathroom by the width. Example: 10 x 10 bathroom =100 square feet. You will need a 100 CFM fan for this bathroom.

Single Vent TD-KIT Bathroom Exhaust Kits


Standard Exhaust Kits
Bathroom KIT-TD100 1 TD100 exhaust fan 1 plastic round grille (PG-100) 1 exterior louvered grille (PER-100W) Integral mounting bracket KIT-TD100x 1 TD100x exhaust fan 1 plastic round grille (PG-100) 1 exterior louvered grille (PER-100W) Integral mounting bracket KIT-TD150 1 TD150 exhaust fan 1 plastic round grille (PG-150) 1 exterior louvered grille (PER-150W) Integral mounting bracket KIT-TD100XL 1 TD100x exhaust fan 1 Vent Light with LED Bulb (VLED-100) Integral mounting bracket KIT-TD100XH 1 TD100x exhaust fan 1 Vent Light with Halogen Bulb (VLH-100) Integral mounting bracket KIT-TD100XF 1 TD100x exhaust fan 1 Vent Light with Fluorescent Bulb (VLF-100) Integral mounting bracket
IMPORTANT: If venting in a non-insulated attic space, or in a cold climate, insulated flexible duct is strongly recommended for condensation issues.

Lighted Standard Exhaust Kits

*Light Bulbs not included in 7 year warranty.


22

Dual Vent Bathroom Exhaust


Bathroom

Fan Sizing for Bathrooms Over 100 SQ. FT.


The following recommendations follow the Home Ventilating Institute (HVI) guidelines: Ventilation for baths over 100 square feet is calculated based on the fixtures in the bathroom. Allow 50 CFM for each standard toilet, shower, steam shower or tub. Whirlpool, garden and hot tubs are calculated at 100 CFM each. Add the CFM for all fixtures and youll have the total CFM required for the bathroom. Step 1: Calculate Bathroom Size: 20 x 10 Bathroom =200 square feet Step 2: 1 Toilet +1 Shower +1 Tub =150 CFM Result: You will need a 150 CFM fan for this bathroom.
23

Dual Vent TD-KIT Bathroom Exhaust Kits


Deluxe Exhaust Kits
Bathroom KIT-TD150-DV 1 TD150 exhaust fan 2 plastic round grilles (PG-150) 1 exterior louvered grille (PER-150W) 1 Y-fitting (SY-6) Integral mounting bracket KIT-TD150L 1 TD150 exhaust fan 2 Vent Lights with LED Bulb (VLED-100) 1 Y-fitting (SY44-6) Integral mounting bracket KIT-TD150H 1 TD150 exhaust fan 2 Vent Lights with Halogen Bulb (VLH-100) 1 Y-fitting (SY44-6) Integral mounting bracket KIT-TD150F 1 TD150 exhaust fan 2 Vent Lights with Fluorescent Bulb (VLF-100) 1 Y-fitting (SY44-6) Integral mounting bracket *Light Bulbs not included in 7 year warranty.
IMPORTANT: If venting in a non-insulated attic space, or in a cold climate, insulated flexible duct is strongly recommended for condensation issues.
24

Lighted Deluxe Exhaust Kits

Quiet Bathroom Ventilation - TD-SILENT


2 speed motors allow for 2 performance levels with each unit (100% variable speed). Easy access to motor without dismounting the fan unit. Easy to install. 5 year warranty. ENERGY STAR qualified. HVI Bathroom
25

Fans Fans ans a s for f Life! Life e!

Innovative Features
Low Noise Levels Duct Air-Seals

Sound waves produced inside the TD, are directed through the perforated inner skin and absorbed by the layer of soundabsorbent material.

Bi-material inlet and outlet incorporating a flexible washer to facilitate installation, absorb vibrations and provide a virtually air-tight seal.

Ventilation that is Out-of-Sight and Out-of-Mind...

When you use our TD-SILENT series with our VL-Vent Light you get ventilation that is Out-of-Sight and Out-of-Mind! The Vent Lights appear to be a regular can light, and when combined with a remotely mounted TD fan, the noise and unsightly look of the traditional bathroom fan are gone! The Vent Lights are aesthetically pleasing grilles with lights that will match any bathroom decor.

TD Bathroom Exhaust Controls - ASHRAE 62.2


CVC - Continuous Ventilation Control
S&Ps CVC allow a new or existing bath fan to run continuously on a low speed. In conjunction with an S&P TD fan a CVC will immediately improve the air quality in the home and reduce the damaging effects of moisture and mold. The CVCs are designed to meet the requirements of ASHRAE 62.2 and the International Residential Code. In areas where ASHRAE 62.2 is not a requirement the CVC is still an economical choice to improve indoor air quality. CVC Model CVC-100 CVC-100x CVC-150 TD Fan Size 100 100x 150 Application Single Inlet Single Inlet Single Inlet Dual Inlet Max. Flow 101 CFM 135 CFM 218 CFM 293 CFM Continuous Flow @ .25SP 20 CFM 20 CFM 20 CFM 40 CFM Bathroom
26

Features

Reduces remodeling costs, helps meet ASHRAE 62.2 requirements Perfect for homes, apartments, dorms, hotels and elderly housing Economical and easy to install in your existing wall box Works with most fan controls, i.e. motion sensors, timers, speed controllers. Dimensions in Inches (mm) Improves the indoor air quality in your home Undetectable, efficient and effective Operates with any standard switch No programming required 120V, 60 Hz, 3A Maximum

Easy Installation. . .

1
Attaches to any standard wall switch.

2
Simple 2 wire connection across the wall switch and fits into most standard wall/ junction boxes.

3
Completely installed in minutes!

Inline Bathroom Ventilation- PV Fans


Epoxy coating on inside and outside of fan housing. Fully speed controllable Perfect for higher static pressure applications Extra long inlet and discharge collars make installation quick and trouble free. Supplied with a strong galvanized steel mounting bracket. All inclusive kits available AMCA, HVI certified, and cULus Listed. ENERGY STAR qualified on sizes 150X and larger. 5 year warranty. Line includes 4 - 12 108 - 942 CFM. Bathroom
27

SY-Y Fitting PV-SERIES Fan

Optional Placement for grille

Fans Fans ans a s for f Life! Life e!

KIT Bathroom Exhaust Kits


Featuring PV-MIXVENT Fans
Bathroom
28

S&P PV-POWERVENT Series fans are also available as easy-to-install kits. This ultra powerful bathroom fan offers a choice of single or dual vent exhaust. These kit are used for installations that require long or complicated duct runs. All PV kits have a standard 8-year warranty.

Standard Exhaust Kits

Deluxe Exhaust Kits

KIT-PV100 1 PV100 exhaust fan 1 plastic round grille (PG-100) Mounting bracket KIT-PV100x 1 PV100x exhaust fan 1 plastic round grille (PG-100) Mounting bracket KIT-PV150 1 PV150 exhaust fan 1 plastic round grille (PG-150) Mounting Bracket

KIT-PV100x-DV 1 PV100x exhaust fan 2 plastic round grilles (PG-100) 1 Y-fitting (SY-4) Mounting Bracket KIT-PV150-DV 1 PV150 exhaust fan 2 plastic round grilles (PG-150) 1 Y-fitting (SY-6) Mounting Bracket KIT-PV200-DV 1 PV200 exhaust fan 2 plastic round grilles (BOR-200) 1 Y-fitting (SY-8) Mounting Bracket

Bathroom Kit Options Overview


Bathroom
29

S&P Bathroom CFM @ 0 Single or Kit Model SP Dual Venting Standard Exhaust Kits KIT-TD100 Low: 97 High: 101 KIT-TD100x Low: 100 High: 135 Low: 218 High: 293

Light

ENERGYSTAR Qualified

Warranty in Years

Single

Yes

Single

Yes

KIT-TD150

Single

Yes

KIT-PV100 108 KIT-PV100x 153 KIT-PV150 245 Single Yes 8 Single 8 Single 8

Standard Lighted Exhaust Kits KIT-TD100XL Low: 100 Single High: 135 KIT-TD100XH Low: 100 High: 135 Low: 100 High: 135

LED

Yes

7*

Single

Halogen

Yes

7*

KIT-TD00XF

Single

Fluorescent

Yes

7*

*Light Bulbs not included in 7 year warranty.

Bathroom Kit Options Overview


S&P Bathroom Kit Model CFM @ 0 Single or SP Dual Venting Light ENERGYSTAR Qualified Warranty in Years Bathroom
30

Deluxe Exhaust Kits KIT-TD150DV Low: 218 High: 293 KIT-PV100x-DV 153 KIT-PV150-DV 245 KIT-PV200-DV 402 Deluxe Lighted Exhaust Kits KIT-TD150L Low: 218 High: 293 KIT-TD150H Low: 218 High: 293 KIT-TD150F Low: 218 High: 293

Dual

Yes

Dual

Dual

Yes

Dual

Yes

Dual

LED

Yes

7*

Dual

Halogen

Yes

7*

Dual

Fluorescent

Yes

7*

*Light Bulbs not included in 7 year warranty.

A Tip from S&P


We recommend the use of Insulated Flexible ducting. This will help reduce sound levels and is better for cold weather climates.

Bathroom Exhaust Grilles


Featuring Vent Lights and Premium Grilles
Bathroom
31

S&Ps Grille Options give you the choice of seven (7) aesthetically pleasing grilles designed to match any bathroom decor. You can choose from our Vent Lights, Premium Grilles or Adjustable Grilles to fit your needs. These grilles are designed to be used exclusively with one of S&Ps remotely mounted inline fans (TD, PV, SWF) for virtually silent bathroom ventilation. Inline fans give you the option to mount your grille over the shower, toilet, tub, or in multiple locations (dual vent). With S&Ps Grille Options the choice is yours!

Vent Lights

Available with LED Bulbs


S&Ps Vent Lights give you ventilation that is Out-of-Sight and Outof-Mind! The Vent Lights appear to be a regular can light, and when combined with a remotely mounted fan, the noise and unsightly look of the traditional bathroom fan are gone! The Vent Lights are aesthetically pleasing grilles with lights that will match any bathroom decor.
Model VLED-100 VLH-100 VLF-100 Description Vent Light with PAR30 LED Bulb Vent Light with PAR30 Halogen Bulb Vent Light with Energy Star Rated Compact Fluorescent Bulb

Dimensions (inches)
7 sq.

5 2.2

5.25

13

-2

Features: Longer duct collar for 4 duct Extendable hanger bars up to 24 7.5 grille Built-in backdraft damper 3 bulb options
9

Why Choose the Vent Light with LED Bulbs?


S&Ps respect for the environment extends to its Vent Lights with the optional LED Bulb. The benefits to the LED Bulbs include: Built to last a minimum of 60,000 hours, plus the LEDs use a fraction of the energy that a traditional incandescent or halogen lamp uses LEDs contain no mercury so they are easy to dispose of, unlike other energy efficient bulbs The LED lamps run cool and are shock resistant, making them safer for use in your home

Premium Grilles
PG Bathroom
32

PGD S&Ps premium grilles come standard with steel collars for easy mounting and installation. They are available with (PGD) and without (PG) backdraft dampers.

Model PG-100 PGD-100 PG-150 PGD-150

Description 4 Plastic Grille with 4 Steel Collar 4 Plastic Grille with 4 Steel Collar and Integrated Backdraft Damper 6 Plastic Grille with 6 Steel Collar 6 Plastic Grille with 6 Steel Collar and Integrated Backdraft Damper

Grille Dimensions (in inches) Grille PG-150G PG-100G Dia. 8 1/8 4 5/8 Height 1 5/8 1 1/2 Fits Duct Dia. 6 4 Fits Collars PG-150D or PGD-150DB PG-100D or PGD-150DB

Collar Dimensions (in inches) Collar PG-100D PGD-100DB PG-150D PGD-150DB Diameter 3 3/4 3 3/4 5 3/4 5 3/4 Length 3 1/4 4 1/8 4 5/8 4 1/8

PG Collar

PGD Collar

Adjustable Grilles
BOR/BOC Exhaust grilles for bathrooms, toilets and other small rooms. All models offer an adjustable central valve to regulate the airflow.

Model
D A

A 145 145 204 244

D 100 125 160 200

E 50 50 50 50

BOR/BOC-100 BOR/BOC-125 BOR/BOC-150 BOR/BOC-200

Weight (lbs) 1 1 1 1

Bathroom Exhaust Accessories


PER-W-Plastic Louvered Shutter
Louvered backdraft shutters manufactured totally from UV stabilized plastic material. B C D E 12 90 98 4 15 110 130 4 20 130 152 4 21 184 205 5 Bathroom A 123 158 178 243
1.73 1.30 1.53 1.34 4.13 2.63

Model PER-100W PER-125W PER-160W PER-200W

CAR-Backdraft Damper
Backdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for positive closure. Dimensions in mm/inches Wgt. Model A B (lbs) 100 80 CAR-100 1 3 15/16 3 1/8 125 100 CAR-125 1 4 15/16 3 15/16 A 150 120 CAR-150 1 7/8 5 4 3/4 200 140 CAR-200 1 7/8 7 5 1/2 250 140 CAR-250 2 13/16 9 5 1/2 B 315 140 CAR-315 2 3/8 12 5 1/2

EPBT-60-Electronic Push Button Timer (10-20-30-60 min.)

SCS5 - Speed Control Slide Type

33

Options for Remodeling or Retrofit


Are you sick of your noisy bathroom exhaust fan? Reduce the noise of your existing bath fan (while increasing performance) use our SWF-SIDEWALL fan! Move the fan motor outside to reduce noise. The SWF fan is designed to mount seamlessly on the outside of your house and allows you to connect to your existing fan housing or grille. The SWF is also perfect when space is an issue or direct venting to the outside is required. Bathroom
34

SWF-SIDEWALL Fan

Same powerful motor found in PV series fans. Low profile aesthetic design. Fully speed controllable. Built-in backdraft damper . Extended opening exhaust grille. 5 year warranty. HVI certified and cULus listed. Line includes 4 - 8 119 - 416 CFM
Fans Fans ans a s for f Life! Life e!

Ceiling Mounted Fans - V-Series


Bathroom
35

S&Ps V-Series Bathroom Fan by RenewAire is the best choice for exhaustonly ventilation. The V-Series improves indoor air quality and increases your homes durability by quickly exhausting contaminants and excess moisture that can cause health issues, mold growth and structural damage.

Performance The most energy efficient line of ceiling mounted ventilation fans available in North America. Aerodynamically engineered to move air with lowest power consumption and sound levels. Motors operate with the lowest heat build up for long life even when run continuously. 5 year warranty. Low air leakage dampers minimize uncontrolled infiltration. The lowest carbon footprint of leading residential ventilation brands. Construction Robust steel housing and duct collar Heat-sink motor unit Internal electrical wiring box Attractive, sturdy grille Impedance and thermal fuse electrical protection UL List for installation in tub/shower enclosures when connected to a GFCI protected branch circuit
Fans Fans ans a s for f Life! Life e!

V-Series Exclusive Accessories


VSWITCH Control
The VSWITCH Control is specifically designed for use with the V-Series fans. This Line Voltage Ventilation Fan Control may be used to comply with ASHRAE 62.2 ventilation rates for residential applications.

Radiation Damper
The V-Series Radiation Dampers are designed to meet local codes that require fans installed in fire rated ceilings to be protected by dampers which are insulated against both heat and flames. These are UL Classified radiation dampers rated at 1, 2 or 3 hours of fire resistance.

V-Series Fan

Hanging Bar Grille Radiation Damper

Range Hood Exhaust Concerns...

Today the kitchen is the heart of our homes, its where we relax, gather and enjoy family and friends. S&P offers a range of inline fans to fit your range hood needs by offering many advantages over traditional (in hood) fans. By virtue of the remote mounting, the noise is kept further from the living space, reducing the sound level of the fan. Remote mounting also allows for a duct silencer (SIL) to be mounted between the fan and the range hood, reducing the fan noise level by another 50% or more. S&P remote fans also offer extended duty times, low maintenance, and do not detract from the homes aesthetics, unlike some unsightly roof mounted units. S&P remote fans are the clear choice for the strongest, quietest installation.

SOLVED!

Range Hood
36

Fans

Accessories

* A grease filter in the range hood is required to use an S&P Inline Fan in this application

Range Hood Exhaust


How to Size Your Kitchen Ventilation System
Due to varying capacities for moving air, prior to selecting your range hood fan, be sure to consult with local residential codes and the range manufacturers recommendations. If you are unable to determine any manufacturers recommendation, S&P has provided the following illustration to assist you with accurately calculating your fan size. The following recommendations follow the Home Ventilating Institute (HVI) guidelines: HVIs recommended kitchen range hood ventilation rates vary and depend on the type of cooking performed. The minimum rates are 40 CFM per lineal foot for a kitchen range hood placed along a wall and 50 CFM per lineal foot for island hoods. However, HVI recommends 100 CFM per lineal foot for wall-mounted kitchen range hoods and 150 CFM per lineal foot for island kitchen range hoods. Kitchen range hoods equipped with multiple speed settings allow low-level, quiet ventilation for light cooking with the ability for effective ventilation when needed. For professional style cook-tops, HVI recommends following the cook top manufacturers advice to estimate the approximate CFM requirements. 48 Range Hood
37

Wall Mount Installations: 100 CFM per foot of width. Example: 48 (4 ft.) wide hood will require 400 CFM. Feet of Width CFM per Foot Air Flow [CFM] 4 x 100 400 40

48

Island Mount Installations: 150 CFM per foot of width. Example: 48 (4 ft.) wide hood will require 600 CFM. Feet of Width CFM per Foot Air Flow [CFM] 4 x 150 600

S&Ps Range Hood Exhaust Fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.

Range Hood Exhaust Typical Installations


Typical PV Installation Typical TD Installation

PV-SERIES Fan

Standard PV Wiring Box ACOP Mounting Clamps TD-SERIES Fan

Range Hood
38

Optional SIL-Silencer

Range Hood Exhaust Accessories


SIL-Sound Attenuator
The galvanized steel silencer is used for kitchen range hood ventilation and other applications where noise is a concern. The S&P silencer reduces the actual sound level of the kitchen ventilation system by 50% or more. They feature rubber seals on inlet and outlet.

RC-Roof Cap
Galvanized steel roof caps with damper flap closure. Duct sizes from 4 to 10.

Dimensions in inches/mm
Model SIL-125 5 A B
9 13/16 9 13/16 12 3/8 14 15 3/4 250 250 315 355 400

Dimensions in inches/mm
C D
700 700 700 700 700 35 7/16 35 7/16 35 7/16 35 7/16 33 7/8 900 900 900 900 860

Wgt. (lbs) 15 18 21 32 32

Model RC-4 RC-6 RC-8 RC-10


6 8 8 11

A
150 200 200 280 6 8 8 11

B
150 200 200 280 4 4 5

C
3 1/2 90

D
12 14 14 17 300 355 355 430 12 14 14 17

E
300 355 355 430 5 5 7

125 6 5/16 SIL-150 160 7 7/8 SIL-200 200 9 13/16 SIL-250 250 12 3/8 SIL-315 315

27 9/16 27 9/16 27 9/16 27 9/16 27 9/16

4 1/2 2 1/2 115 60 125 125 175 4 4 4 100 100 100

Wgt. (lbs) 1 1 1 1

100 100 125

CAR-Backdraft Damper
Backdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for positive closure.

ACOP-Vent Mounting Clamp


Manufactured from galvanized steel with an insulated rubber duct seal. These clamps facilitate the connection and disconnection of round ventilation ducts. All models incorporate internal hanging tabs for suspending the ducting / fan when horizontally mounted.

Dimensions in mm/inches
Model CAR-100 CAR-125 CAR-150 CAR-200 CAR-250 A
100 3 15/16 125 4 15/16 150 5 7/8 200 7 7/8 250 9 13/16 140 5 1/2 140 5 1/2 120 4 3/4 100 3 15/16 80 3 1/8

Wgt. (lbs) 1 1 1
1 2 Model ACOP-V100 ACOP-V125 ACOP-V150 ACOP-V200 Description 4 Connector clamps (2 ea., sold in pairs) 5 Connector clamps (2 ea., sold in pairs) 6 Connector clamps (2 ea., sold in pairs) 8 Connector clamps (2 ea., sold in pairs)

Wgt. (lbs) 1 1 1 1

39

Range Hood

Clothes Dryer Boosting Concerns...

If you have a dryer with long or complicated duct runs, S&P offers the perfect solution to increase dryer efficiency: the PV100x Dryer Booster Fan. The PV100x has been specifically designed to handle dryer boosting applications when overcoming long or complicated duct runs. This system helps save on drying time, moisture build-up, wear and tear on your dryer, and helps save on your electric bill. The centrifugal blade design is able to overcome extreme resistance from the most challenging installations. The PV-100x offers a fully enclosed motor with Class F insulation which ensures a long, trouble free life; thus making it the right choice for enhancing the performance of your clothes dryer. The PV-100x fan is available separately or as part of a kit that includes everything necessary for a hands-free operation. Once the system is installed you will no longer waste time, energy or unnecessary wear and tear on your dryer. The next step is to select which activation best fits your needs.

SOLVED!

How to activate the PV-100x fan for clothes dryer boosting


Clothes Dryer
PV-100xps DBF-100xc IL-115/230 SWF100x
40

Pressure Switches
Pressure switches are a viable method of fan activation and a good solution for many installations. The pressure switch senses the pressure differential in the duct created by the dryer operation, thus activating the fan. NOTE Conversely, when the dryer is deactivated, the pressure The PV-100x Dryer Booster fan is suitable for use with duct runs of up to 105 linear feet of 4 rigid duct switch senses this differential and the fan is deactivated. or a maximum of 6 elbows and 80 feet. S&Ps PV-100xps utilizes a compact pressure sensor and run timer enclosed within the junction box and mounted to the fan housing. The pressure sensor is also available as an accessory.

Current Sensors

Current sensors are S&Ps preferred method of activation. They are fail-safe, as there is no maintenance required on the current sensor and theyre easy to install. The current sensing device can be installed at the outlet (where the dryer plugs into the wall) or at the circuit breaker box. When the device senses current going to the dryer, it activates the fan and vice-versa. No thought! No maintenance! Our choice!

Interlocks

Interlocks, like Current Sensors, are another fail-safe method of clothes dryer booster activation. The interlock senses when the fan is running and activates the dryer. Used as a safety feature, if the fan is not running or if there is a problem with the fan the dryer will not turn on.

All 3 activation methods are available as accessories or in the S&Ps all inclusive dryer booster kits.

SWF - Sidewall Mount Exhaust Fan for Dryer Boosting


The sidewall unit can be paired with a current sensor or pressure switch when interior duct access in a home, apartment or townhouse is limited or difficult. The expanded exhaust grille allows for the easy passing of lint laden air. The SWF utilizes the same powerful motor as the PV-100x and is also suitable for duct runs up to 105 feet or up to 80 feet with 6 elbows. The low profile SWF fan is easy to install with an epoxy coating that can be painted to match the exterior of the building. The SWF also offers the same trusted 5 year warranty.

Garage Ventilation Concerns...

Featuring S&Ps SWF-SIDEWALL Series

SOLVED!

Gasoline, automotive exhaust fumes, paint, fertilizer, pesticides and other potentially harmful products are present in most garages and the effect on the quality of air inside the home is undoubtedly compromised if not properly addressed. Keep the hazardous fumes in your attached garage from entering your home and harming you and your family with the SWF Series fans. S&Ps Garage Ventilation solutions help keep the contaminants in your garage from harming you and your family! The SWF Series outdoor rated exterior housing provides easy access from the outside of a building or dwelling. This makes the SWF a great solution for installations where attic space or easy indoor access is difficult and not suitable for traditional PV style in-line mounting. The Sidewall Fan Series (SWF) of direct drive centrifugal ventilation fans consists of five model sizes: 4 through 8. All models are designed for direct connection in-line with standard diameter round ducting. Airflow performance values range from 119-416 CFM. You can also use S&P TD-MIXVENT, TD-SILENT or PV-POWERVENT for your garage ventilation needs.

TD-MIXVENT

TD-SILENT

PV-POWERVENT

41

Garage

Indoor Air Quality Concerns...


For Your Family
Todays homes are built to be tighter and more energy efficient than ever before. Builders and homeowners use vapor barriers, caulking, and better sealed doors and windows to reduce energy loss caused by air infiltration. Tighter homes also mean that pollutants are trapped indoors. Poor indoor air quality, caused by trapped pollutants, is not only uncomfortable to the occupants, but it is a health hazard. Volatile Organic Compounds (VOCs) like formaldehyde, as well as cigarette smoke, radon, household cleaners, and perfumes can threaten your familys well being.

For Your Home

Everyday activities such as showering, cooking, doing laundry, even breathing are just a few ways that moisture is generated in your home (one gallon per person, everyday). Moisture that is trapped in your home can lead to structural damage. Signs of structural damage include heavy condensation on windows, water damage on window sills and molds forming in cold corners of the home.

IAQ

Whole House Ventilation Made Easy!

Whether you have a new home under construction or an existing home needing a ventilation upgrade, S&P provides powerful, quiet blowers in its TR (total recovery) Series for all climates. You can enjoy ample air exchange without the objectionable noise associated with lower quality products. If you want the best whole house approach to efficient and effective ventilation, S&Ps TR Series makes your choice simple.

42

Indoor Air Quality Concerns...


Protect Your Family & Your Home

SOLVED!

To protect the two most valuable investments of your life, your home and your family, improving indoor air quality is key. With S&Ps TR (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed air-to-air energy exchange core. The air streams are physically separated by many layers of plates so there is no mixing or contamination of the fresh air. The plates are made of an engineered resin material that simultaneously transfers heat by conduction and humidity by attracting and moving water vapor from one air stream to the other. S&Ps TRs moderate extremes in both temperature and humidity, creating a comfortable indoor environment. The unique moisture transfer capability of the S&P core also eliminates condensation and frost build up in most applications. Unlike other ERVs on the market no mechanical or electrical defrost systems are needed, which means higher heat recovery efficiencies, easier installation and more reliable operation.

The CORE

Efficient transfer of heat and moisture No liquid is accumulated; no drain pan or defrost mechanism is required! Industry best 10-year warranty

Contaminated air is exhausted from your home, while the static plate core regulates extremes in humidity

43

IAQ

Series TR - The Ultimate ERV for ALL Climates

The Difference Between ERVs and HRVs

Q: A: Q: A: Q: A:
IAQ
44

Energy Recovery Ventilators (ERV) and Heat Recovery Ventilators (HRV) both moderate extremes in ventilation air temperature so what is the difference? ERVs Transfer BOTH heat AND humidity Use enthalpic core S&Ps TR is an ERV HRVs Transfer ONLY heat Use aluminum core or simple plastic cores

Can ERVs be used in climates subject to cold winters? Yes! Because ERVs transfer both heat and humidity they are the perfect choice for any climate. In the winter ERVs: Warm outdoor air close to room temperature Use heat that would otherwise be lost with the exhaust air. Transfer water vapors to moderate extremes in humidity levels Help prevent moisture damage or over-drying of the home.

Why are ERVs better than HRVs? HRVs and ERVs are similar in that they both: Improve Indoor Air Quality Moderate extremes in ventilation temperature Use heat that would otherwise be lost with the exhaust air in the winter Provide necessary fresh air while pre-cooling in the summer ONLY ERVs have the ability to transfer water vapors or moisture so they: Help prevent over-drying of the home in colder seasons Lessen the demand on the air-conditioning system in warmer seasons Are typically 3x more energy efficient in the summer than products (or units) that transfer only heat (HRVs)

Q: A:

Why is S&Ps Series TR the Ultimate ERV? S&Ps TRs provide the same benefits as other ERVs on the market. Major Series TR advantages include: More heat transfer than most HRVs More humidity control than other plate exchangers Simplicity and positive airstream separation not offered by wheel type ERVs 10-year core warranty

Energy Recovery Applications


Central Exhaust
Your BEST choice for green ventilation, Series TR exhausts stale air, brings in fresh air and saves energy year-round. Series TR Replaces bathroom exhaust fans 20 CFM continuous per bathroom 50 CFM intermittent per bathroom Meets ASHRAE 62.2 when used with one of S&Ps Percentage Timer Controls Other possible exhaust locations: kitchen area (cannot exhaust range hood), utility room, smoking room, hobby room, etc. Small duct work system to collect air from each exhaust location Fresh air may be supplied to furnace (AC) return air duct Optional automatic proportional runtime control and push button control available

A Central Exhaust system replaces bathroom exhaust fans.

S&P TR prevents window condensation.

S&P TR draws room air from places that are to be exhausted to outside.

S&P TR moderates extremes in both heat and humidity year round. Air polluter

Use one of S&Ps Inline Centrifugal fans (SWF shown) for a silent Range Hood Exhaust.

After transferring its heat inside the TR, stale air is exhausted outside.

Return-air plenum

Outside-air intake draws fresh air into the TR, where it is tempered before it enters the returnair plenum.

General Ventilation The Perfect Pair

Bathroom exhaust fans are also required


Bathroom fans as required for point source exhaust. S&Ps TD Mixvent inline fan makes the perfect choice.

S&P TR draws room air from air handler return air duct system.

To get the most efficient and effective general ventilation system available use a TR with S&Ps exclusive TD-MIXVENT inline fans for bathroom exhaust.

Energy efficient homes can trap indoor air pollutants. Air polluter

Use one of S&Ps Inline Centrifugal fans (SWF shown) for a silent Range Hood Exhaust.

Outside-air intake draws fresh air into the TR, where it is tempered before it enters the returnair plenum.

Return-air plenum S&P TR70

After transferring its heat inside the TR, stale air is exhausted outside.

45

IAQ

Energy Recovery Controls & Sizing


SPTL - Percentage Timer Control Primary control for TR70, TR130, TR200 and TR300 Runs unit an adjustable amount of time each hour Two wire, low voltage connection to TR Meets ASHRAE 62.2 continuous ventilation standards SPBL - Push Button Point-of-Use Control Push button control turns on unit from bathrooms or other intermittent exhaust locations 20 minute run-time with one touch Push 2x for 40 or 3x for 60 minutes Two wire, low voltage connection to SPTL

SFM - Percentage Timer Control with Furnace Interlock Alternate primary control for TR70, TR130, TR200 and TR300 Wires to TR unit and either thermostat or furnace control to turn on furnace blower Six wire, low voltage connection Meets ASHRAE 62.2 continuous ventilation standards SHW-20 - Dehumidistat Rotary dial dehumidistat Turn the dial to set desired humidity level Designed for convenient installation in bathrooms, kitchen or laundry room Dehumidifies when inside air is more humid than the set point Caution: the outside air must be less humid than the indoor air for this to work.

Choosing the Right Size TR


Choosing the correct size TR for your home is easy, all you need to know is the square footage. IAQ
46

If you home is up to: 1500 Sq. Ft. you need a TR70 2700 Sq. Ft. you need a TR130 4000 Sq. Ft. you need a TR200 6000 Sq. Ft. you need a TR300

IAQ and ERVs Information


Improves Indoor Air Quality By providing simultaneous exhaust and fresh air supply, S&P reduces the concentration of harmful pollutants in indoor air - an absolute must in schools, offices and smoking environments. Meets Ventilation Codes for Air Exchange Provides ample ventilation to meet ASHRAE 62 and the International Mechanical Code that now requires two to three more air exchanges than in the past. Controls Excess Moisture Unlike conventional ventilation or basic heat exchangers, S&P moderates not only the temperature but the humidity content of incoming air, limiting humidity swings and associated biologic growths. Optimum Cold Weather Performance Recaptures heat otherwise lost to exhaust air while controlling humidity extremes. This greatly reduces the demand on heating equipment - lowering both initial costs and energy bills. Also protects heating coils from freeze damage. Optimum Warm Weather Performance Pre-cools and dehumidifies the fresh airstream by transfer of heat and humidity to the exhaust airstream. This greatly reduces air conditioning demand - lowering both initial costs and energy bills. On retrofits, the ventilation rate of existing A/C equipment can be as much as doubled. Energy Saved = Dollars Saved S&Ps all-weather performance can cut annual energy bills for heating, cooling and dehumidification of ventilation air by 50% or more.

Terms to Know
Sensible Heat The amount of energy involved in raising or lowering the temperature of air not including any energy required to cause water vapor to change state. Latent Heat The amount of energy associated with the humidity (or water vapor content ) of an air stream. A drier air stream contains less latent heat and will impose a smaller latent load on the air conditioner. Enthalpy The total amount of energy contained in air, the sum of sensible and latent heat. Balanced Ventilation A ventilation strategy using both an exhaust air blower and a supply or make-up air blower that does not pressurize or de-pressurize a building. Air-to-Air Heat Exchanger Generic term for technologies designed to transfer heat -- and sometimes moisture -- between two air streams. Heat Recovery Ventilator HRV An air-to-air heat exchanger that transfers sensible heat only; no humidity (latent heat) transfer occurs between the two air streams. Energy Recovery Ventilator ERV In Cold Weather, some of the humidity in the inside air is recovered along with its latent energy. Non-enthalpic heat recovery systems lose that latent energy.

47

IAQ

Soler & Palau USA 6393 Powers Ave. Jacksonville, FL 32217 p: 800.961.7370 f: 800.961.7379 www.solerpalau-usa.com

Soler & Palau Canada 5600 Ambler Drive Mississauga, ON L4W 2K9 p: 866.733.0233 f: 866.358.5346 www.solerpalaucanada.com

48

You might also like