You are on page 1of 52

H e at i n g t e c h n o lo g y

All you
can heat

f o r t h e

h o m e

Produc t Catalogue 2011


Innovative products for an optimum temperature

Hemstedt HEM-SYSTEM
Thin-bed HEATING MATS
With sleeveless cold/warm splice

The Hemstedt self-adhesive thin-bed heating mat has been fitted with the
HEM-SYSTEM since 2005: The cold/warm splice is now sleeveless so that the typical
problems associated with bulky shrinkable sleeves are eliminated. This simplifies the
work for the floor fitter and the electrician. All subsequent work can be carried out on
a flat surface. The HEM-SYSTEM has established itself as a successful solution.

Produc t Innovation

For e ven simpler installation


The sleeveless splice is absolutely waterproof, and therefore ideal for installations
requiring moisture proofing. Another benefit: This insulating covering is completely
resistant to chemicals and temperatures up to 200 C. This is provided right up to the
thermostat.

NEW

Before
leeveless
Self-adhesive
100 % waterproof

Direct from the manufacturer


Insulating covering completely
chemical and temperature resistant

About us

Hemstedt has been one of the leading manufacturers of heating cables and
products for cold store houses for over 40 years. Our high-quality products are
produced in accordance with the latest technical standards.
As an expert in heating cables and cold store technology, Hemstedt not only complies
with the very individual requirements of its customers, but also stands out by frequently presenting trend-setting innovations.
A lot of these developments are protected by international patents. Many of these
developments are protected by international patents. Our customers all over the world
not only appreciate the wide range of Hemstedt products, but also the short delivery
times, the professional handling and our customized pricing. Our company is provided
with an operating area of more than 16,000 m2 and has worked for its leading position
against keen competition within the sector. We aim to always
Satisfied customers the aim we share.
See for yourself and benefit from the many possibilities our products offer
also for your product range!

Hemstedt quality: Excellent!

EC type approval certificate KEMA 09ATE X0021 U

IECEx Declaration of conformity IECEx KEM 10.0010 U

EN 60079-0:
EN 60079-30-1:

IEC 60079-0:
IEC 60079-30-1:

2006
2007

EN 61241-0: 2006
EN 61241-1: 2004

2004
2007

IEC 61241-0: 2004


IEC 61241-1: 2004

Hemstedt GmbH is one of the 100 most innovative


medium-sized companies in Germany. It was
outstanding in the renowned top 100 Innovators
comparison of companies on account of its systematic, well-conceived and accordingly successful
innovation management, and in 2008 was awarded
the sought after top 100 quality seal. In the area
of innovation-supporting top management,
the company even succeeded in jumping up the
rankings to 7th place. In this category, Hemstedt
is thus now one of the 7 most innovative mediumsized companies in Germany.

Hemstedt E very thing from a single source


Our range of services

Hemstedt is the successful specialist and reliable OEM partner for innovative electrical
underfloor heating systems. Cold storage technology and special solutions, together with
consulting, project planning and development, complete the portfolio.
Take advantage of this extensive range from a single source:
Hemstedt Home technology
Electric underfloor heating systems
Electric thin-bed heating mats for dry installation / laminate flooring
Electric thin-bed heating mats for laying in wet rooms
Electric outdoor area heating systems
Frost protection heating elements/ pipe heating element also with earthed plug
Roof gutter heating systems also with earthed plug
Self-regulating heating bands
Manufactured heating cables
Special heating elements
Thin-bed heating mats, warm water
Hemstedt farming, gardening and sport
Heating cable for animal husbandry and plant growing
Heating cables for heating sports grounds
Hemstedt cold storage technology
Emergency alarm systems
Electrical under-freezing protection heating mats
Heated and unheated pressure compensating valves
Deep-freeze cells and cold storage cells as well as deep-freeze
buildings and cold storage buildings
For cells and cold storage buildings
Controllers/temperature regulators
Hemstedt cable factory
Heating cables in material groups
PE, PVC, silicon, FEP, PFA and PTFE

Contents

Figure

Product

Page

Underfloor heating
Thin-bed heating mats and heating cables

Underfloor heating Concrete heating mats /


heating cables and asphalt heating mats / heating cables

17

Outdoor heating mats

22

Frost protection heating elements

32

Eaves gutter heating

38

Farming and gardening

44

Heating cables for outdoor sports areas

46

Accessories: Distance bars

48

Natural stone heating elements

On
request

Heating cables on drum /


Self-regulating heating tapes Separate catalogue

On
request

Cold storage technology Separate catalogue

On
request

ATE X explosion proof heating cables and connection


technology Separate catalogue

On
request

Underfloor heating systems

HEM-SYSTEM
Thin-bed direc t heating mats

Thin-bed heating mats in adhesive


for tiles and natural stone

Thin-bed heating mats Dry installation system


for laminate and ready-to-lay wooden parquet

Underfloor heating systems

MODERN UNDERFLOOR HEATING SYSTEMS


WITH LOW INSTALLATION HEIGHT
Ideal for different building conditions

Modern underfloor heating systems from Hemstedt generate


heat source over a large-area to ensure a comfortable room temperature.

Thin-bed heating for tiles


Thin-bed heating mats and heating cables specially designed for installation
in bathrooms, showers, childrens rooms, living rooms and bedrooms.
The thin-bed heating mats and heating cables are layed directly in the levelling
compound. By cutting the heating mats they can be adapted easily to different
building conditions. The maximum output of an underfloor direct heating system
must not exceed 150 W/m.

Dry installation system for laminate


and ready to lay parquet floor
The brand new HEM dry installation system sets new standards in warmth,
installation height and mounting. With its unique heating mat concept using
aluminium-coated textile fibre glass, Hemstedt ensures even heat distribution and
super fast heating within a few minutes. The heating cables are extremely thin at
only 2.8 mm, fit easily in the sound insulation and fully secured against slipping.
The specialists view: Ideal for renovation, new builds and also subsequent removal.
The HEM dry installation must only be layed in dry rooms. By cutting the heating
mats they can be adapted easily to different building conditions. All components
must be temperature resistant up to 80 C. A sound/heat insulation with fire class
B2 is required.

eight!
llation h vering
a
t
s
in
w
o
Lo
+ floor c
m
Max. 5 m

Cold connection cable

Sleeveless splice

Heating cable

The sleeveless splice is absolutely waterproof, and therefore ideal for installations
requiring moisture proofing.

Warmth made to measure


Direct from the manufacturer
Self-adhesive
100 % waterproof
Insulating covering completely
chemical and temperature resistant

For use in tile adhesive or levelling compound


Thin-bed heating mat sets
Thin-bed heating mats / Thin-bed heating cables
Dry installation under laminate and engineered parquet flooring
ALU dry installation system
Intelligent temperature controllers
Hemstedt regulators

Page
8
11
13
15

Thin-bed heating mats

DHSU Thin-bed heating mat SET


Sleeveless with timer thermostat, flush installation, for installation
DHSU thin-bed heating mat

HEM SYSTEM heating mats with single-end connection cable for mounting in tile adhesive / or
levelling compound. Ideal for renovations, new buildings as well as for baths, showers, living
rooms, offices etc.
The thin-bed heating mat set contains the following products:
1 HEM direct heating mat with single-end connection cable 150 W/m and 4.00 m connection cable
1 temperature regulator with self-teaching timer thermostat and sensor, flush
1 end seal sensor for sensor tube
1 sensor tube for room thermostat
1 switch socket
1 installation instructions
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................150 W/m
Cold connection cable..................................................................................................1 x 4.00 m
Minimum installation temperature.........................................................................5 C
Smallest bending radius..............................................................................................6 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Approvals..........................................................................................................................VDE
Cold / warm splice..........................................................................................................sleeveless, without shrinkable sleeve
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.46 m
Calculated width.............................................................................................................0.50 m
Sleeveless
splice

150 W/m 230 V


DHSU thin-bed heating mats with single-end connection cable
Heating output W

Surface area m

Calculated width m

Length m

Order no.

Price/pce

150
225
300
375
450
525
600
675
750
900
1050
1200
1350
1500

1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
6.00
7.00
8.00
9.00
10.00

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.00
12.00
14.00
16.00
18.00
20.00

30751-150 U-SET
30751-225 U-SET
30751-300 U-SET
30751-375 U-SET
30751-450 U-SET
30751-525 U-SET
30751-600 U-SET
30751-675 U-SET
30751-750 U-SET
30751-900 U-SET
30751-1050 U-SET
30751-1200 U-SET
30751-1350 U-SET
30751-1500 U-SET

266.60
279.30
287.30
323.40
338.80
381.60
406.00
419.70
472.20
530.10
597.50
663.90
711.60
754.40

Order no.

Price/pce

Cold connection cable 1.00 m - 4.00 m 0.50 mm I 4.50 m - 9.00 m 0.75 mm I 10.00 m 1.00 mm
Heat insulation is required in flooring in all cases.

Accessories
Calculated width

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats
they can be
adapted easily to
different building
conditions.

Article designation
Cold connection cable for extension 3 x 1.00 mm, 1.00 m, black

81302-1.00 BL/SW

3.60

Mounting sleeve (1, factory fitted), for extension

26121

6.00

Mounting / repair set with cold connection cable 1 x 5.00 m,


incl. 1 sleeve, for extension

26155

19.00

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.60

Plastic switch socket for room thermostat

20702

0.70

Sensor tube for room thermostat, length: 2.50 m

20703

4.90

Spare temperature sensor timer thermostat

93099 sensor

13.09

A residual current device (FI < 30 mA) must be provided as a protection measure.
Extended cold connection cables cannot be returned.

Simply cut and adjust.


8

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Thin-bed heating mats

DHSPA thin-bed heating mat SET


Sleeveless with point scale regulator, flush
DHSPA thin-bed heating mat

HEM SYSTEM heating mats with single-end connection cable for mounting in tile adhesive / or
levelling compound. Ideal for renovations, new buildings as well as for baths, showers, living
rooms, offices etc.
The thin-bed heating mat set contains the following products:
1 HEM direct heating mat with single-end connection cable 150 W/m and 4.00 m
cold connection cable
1 analog regulator, flush and sensor
1 end seal sensor for sensor tube
1 sensor tube for room thermostat
1 switch socket
1 installation instructions
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................150 W/m
Cold connection cable..................................................................................................1 x 4.00 m
Minimum installation temperature.........................................................................5 C
Smallest bending radius..............................................................................................6 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Approvals..........................................................................................................................VDE
Cold / warm splice..........................................................................................................sleeveless, without shrinkable sleeve
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.46 m
Calculated width.............................................................................................................0.50 m
Sleeveless
splice

150 W/m 230 V


DHSPA thin-bed heating mats with single-end connection cable
Heating output W

Surface area m

Calculated width m

Length m

Order no.

Price/pce

150
225
300
375
450
525
600
750
900

1.00
1.50
2.00
2.50
3.00
3.50
4.00
5.00
6.00

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

2.00
3.00
4.00
5.00
6.00
7.00
8.00
10.00
12.00

30751-150 PA-SET
30751-225 PA-SET
30751-300 PA-SET
30751-375 PA-SET
30751-450 PA-SET
30751-525 PA-SET
30751-600 PA-SET
30751-750 PA-SET
30751-900 PA-SET

195.50
202.50
248.00
279.50
301.10
338.10
366.30
429.50
487.10

Cold connection cable 1.00 m - 4.00 m 0.50 mm I 4.50 m - 6.00 m 0.75 mm


Heat insulation is required in flooring in all cases.

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.00 mm, 1.00 m, black

81302-1.00 BL/SW

3.60

Mounting sleeve (1, factory fitted), for extension

26121

6.00

Mounting / repair set with cold connection cable 1 x 5.00 m,


incl. 1 sleeve, for extensiong

26155

19.00

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.60

Plastic switch socket for room thermostat

20702

0.70

Sensor tube for room thermostat, length: 2.50 m

20703

4.90

Spare temperature sensor timer thermostat

93099-Fhler

13.09

A residual current device (FI < 30 mA) must be provided as a protection measure.
Extended cold connection cables cannot be returned.

Calculated width

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats
they can be
adapted easily to
different building
conditions.

Simply cut and adjust.


As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Thin-bed heating mats

DHSP thin-bed heating mat SET


slee veless
with point scale regulator, non-flush, for installation in tile adhesive

DHSP thin-bed heating mat

HEM SYSTEM heating mats with single-end connection cable for mounting in tile adhesive / or
levelling compound. Ideal for renovations, new buildings as well as for baths, showers, living
rooms, offices etc.
The thin-bed heating mat set contains the following products:
1 HEM direct heating mat with single-end connection cable 150 W/m and 4.00 m connection cable
1 temperature regulator with self-teaching timer thermostat and sensor, flush
1 end seal sensor for sensor tube
1 sensor tube for room thermostat
1 switch socket
1 installation instructions
Technical data

Sleeveless
splice

Nominal voltage.............................................................................................................230 Volt


Output................................................................................................................................150 W/m
Cold connection cable..................................................................................................1 x 4.00 m
Minimum installation temperature.........................................................................5 C
Smallest bending radius..............................................................................................6 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Approvals..........................................................................................................................VDE
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.46 m
Calculated width.............................................................................................................0.50 m

150 W/m 230 V


DHSP thin-bed heating mats with single-end connection cable
Heating output W

Surface area m

Calculated width m

Length m

Order no.

Price/pce

150
225
300
375
450
525
600
750
900

1.00
1.50
2.00
2.50
3.00
3.50
4.00
5.00
6.00

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

2.00
3.00
4.00
5.00
6.00
7.00
8.00
10.00
12.00

30751-150 P-SET
30751-225 P-SET
30751-300 P-SET
30751-375 P-SET
30751-450 P-SET
30751-525 P-SET
30751-600 P-SET
30751-750 P-SET
30751-900 P-SET

180.90
208.40
234.10
265.00
286.90
324.10
352.00
415.20
473.80

Cold connection cable 1.00 m - 4.00 m 0.50 mm I 4.50 m - 6.00 m 0.75 mm I


Heat insulation is required in flooring in all cases.

Accessories
Article designation
Calculated width

Supplied width
Calculated width

Order no.

Price/pce

Cold connection cable for extension 3 x 1.00 mm, 1.00 m, black

81302-1,00 BL/SW

3.60

Mounting sleeve (1, factory fitted), for extension

26121

6.00

Mounting / repair set with cold connection cable 1 x 5.00 m,


incl. 1 sleeve, for extension

26155

19.00

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.60

Plastic switch socket for room thermostat

20702

0.70

Sensor tube for room thermostat, length: 2.50 m

20703

4.90

A residual current device (FI < 30 mA) must be provided as a protection measure.
Extended cold connection cables cannot be returned.

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Simply cut and adjust.

10

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Heating mats, self-adhesive

Thin-bed heating mats

DH thin-bed heating mats, sleeveless


DR thin-bed heating cables, sleeveless
DH thin-bed heating mat

HEM SYSTEM Heating mats and thin-bed heating cables with single-end connection cable for
installation in tile adhesive / or levelling compound. Ideal for renovations, new buildings as
well as for baths, showers, living rooms, offices etc.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................150 W/m
Cold connection cable..................................................................................................1 x 4.00 m
Minimum installation temperature.........................................................................5 C
Smallest bending radius..............................................................................................6 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Approval............................................................................................................................VDE (1-10 m)
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.46 m
Calculated width.............................................................................................................0.50 m

150 W/m 230 V


DH thin-bed heating mats with single-end connection cable

DR thin-bed heating cables

Heat
output W

Surface
area m

Calculated
width m

Mat
Order no.
length m

Price/pce

Element
length m

Order no.

Price/pce.

150
225
300
375
450
525
600
675
750
900
1050
1200
1350
1500
1800
2250

1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
6.00
7.00
8.00
9.00
10.00
12.00
15.00

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.00
12.00
14.00
16.00
18.00
20.00
24.00
30.00

30751-150
30751-225
30751-300
30751-375
30751-450
30751-525
30751-600
30751-675
30751-750
30751-900
30751-1050
30751-1200
30751-1350
30751-1500
30751-1800
30751-2250

115.80
144.70
162.10
196.10
227.80
258.50
284.50
319.70
346.80
403.50
470.50
539.20
584.10
543.60
645.34
781.72

12.07
17.66
23.77
29.87
35.97
41.56
47.67
53.77
59.87
71.57
83.77
95.47
107.67
119.37
143.27
179.37

37702-12,07
37702-17,66
37702-23,77
37702-29,87
37702-35,97
37702-41,56
37702-47,67
37702-53,77
37702-59,87
37702-71,57
37702-83,77
37702-95,47
37702-107,67
37702-119,37
37707-143,27
37707-179,37

85.90
102.70
114.30
136.50
159.80
179.00
202.00
228.40
243.00
280.40
330.60
376.80
414.70
460.40
537.26
661.88

0.50
0.50

39.00
49.00

30688-2379
30688-3038

895.72
997.13

193.11
242.49

37708-193,11
37708-242,49

705.85
827.96

Sleeveless
splice

DR thin-bed
heating cables

1260 W/m 230 V


2379*
3038*

19.50
24.50

* with shrinkable sleeve.


Cold connection cable 1.00 m - 4.00 m 0.50 mm I 4.50 m - 9.00 m 0.75 mm I 10.00 m 1.00 mm
Heat insulation is required in flooring in all cases.

Distance bars for thin-bed heating cables

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.00 mm, 1.00 m, black

81302-1,00 BL/SW

3.60

Mounting sleeve (1, factory fitted), for extension

26121

6.00

Mounting / repair set with cold connection cable 1 x 5.00 m,


incl. 1 sleeve, for extension

26155

19.00

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.60

Plastic switch socket for room thermostat

20702

0.70

Sensor tube for room thermostat, length: 2.50 m

20703

4.90

Analog point scale regulator with sensor, non-flush

93098

81.30

Analog point scale regulator with sensor, flush

93093

96.20

Intelligent temperature monitoring


timer thermostat with self-teach function and sensor, flush

93099

118.10

Distance bars

20060

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure. Extended cold connection cables cannot be returned.

As of 03 /11. Subject to alterations. All prices not including VAT.

Calculated width

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Simply cut and adjust.

www.hemstedt.com

11

Thin-bed heating mats

DH-Z thin-bed heating mats


DR-Z thin-bed heating cables

NEWr-t!hin, withou!t

supe technology
shrink
DH-Z thin-bed
heating mat

Sleeveless, heating mats, self-adhesive


HEM SYSTEM heating mats and thin-bed heating cables with double-end connection cable for
installation in tile adhesive / or levelling compound. Ideal for renovations, new buildings as
well as for baths showers, living rooms, offices etc.
Technical data

Sleeveless
splice

Nominal voltage.............................................................................................................230 Volt


Output................................................................................................................................150 W/m
Cold connection cable..................................................................................................1 x 6.00 1 2.50 m
Minimum installation temperature.........................................................................5 C
Smallest bending radius..............................................................................................6 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Standard............................................................................................................................60335-2-96
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.46 m
Calculated width.............................................................................................................0.50 m

150 W/m 230 V

DR-Z thin-bed
heating cables

DH-Z heating mats with double-end connection cable

DR-Z thin-bed heating cables

Heat
output W

Surface Calculated
area m width m

Mat
length m

Order no.

Price/pce

Element
length m

Order no.

Price/pce

150
225
300
375
450
525
600
675
750
900
1050
1200
1350
1500

1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
6.00
7.00
8.00
9.00
10.00

2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.00
12.00
14.00
16.00
18.00
20.00

30800-150
30800-225
30800-300
30800-375
30800-450
30800-525
30800-600
30800-675
30800-750
30800-900
30800-1050
30800-1200
30800-1350
30800-1500

73.80
112.20
144.50
171.60
196.30
227.30
244.00
282.90
311.90
366.40
414.20
458.96
502.83
519.20

12.07
17.66
23.77
29.87
35.97
41.56
47.67
53.77
59.87
71.57
83.77
95.47
107.67
119.37

37709-12,07
37709-17,66
37709-23,77
37709-29,87
37709-35,97
37709-41,56
37709-47,67
37709-53,77
37709-59,87
37709-71,57
37709-83,77
37709-95,47
37709-107,67
37709-119,37

55.00
80.80
104.00
123.00
140.10
161.90
173.20
200.00
220.20
256.50
287.50
295.09
302.94
319.91

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

Heat insulation is required in flooring in all cases.

Sleeveless
splice

Distance bars for thin-bed heating cables

Calculated width

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Accessories
Article designation

Order no.

Cold connection cable for extension 1.00 mm, 2 x 1.00 m, black

81101-1,00 SW

Price/pce

Mounting sleeve (2, factory fitted), for extension

26123

3.10
5.10

Mounting / repair set with cold connection cable 2 x 5.00 m,


incl. 2 sleeves, for extension

26158

12.00

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.60

Plastic switch socket for room thermostat

20702

0.70

Sensor tube for room thermostat, length: 2.50 m

20703

4.90

Analog point scale regulator with sensor, non-flush

93098

81.30

Analog point scale regulator with sensor, flush

93093

96.20

Intelligent temperature monitoring


timer thermostat with self-teach function and sensor, flush

93099

118.10

Distance bars

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.
Extended cold connection cables cannot be returned.

Further information in our installation instructions.

Simply cut and adjust.

12

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Sleeveless, specially developed for laying under laminate


and engineered parquet flooring.

Heating mat with single-end connection cable. The aluminium-coated textile glass fabric,
ensures even heat distribution underneath the flooring. The small installation height of only
approx. 5 mm + floor makes this product ideal for renovations and for new buildings. Must only
be installed in dry rooms.
The regulation system uses thermostats that are specially adapted to this product.
The HEM dry installation system is manufactured in accordance with VDE 60335-2-96.
Installation(brief description):
A vapour barrier must be installed and fitted if necessary. The room must be fitted with a temperature resistant sound and heat insulation (80 C, B2). The heated area must be fitted with our
HEM dry installation system. Fit floor covering.

11
H EMSTEDT
ation 20 me
Innoinvand shortest warm up ti
Extra th

ALU thin-bed
heating mat

Thin-bed heating mats

ALU dry installation

Sleeveless
splice

Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................100 W/m
Cold connection cable..................................................................................................1 x 4.00 m
Minimum installation temperature.........................................................................5 C
Smallest bending radius..............................................................................................6 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Standard............................................................................................................................60335-2-96
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Heating cable diameter...............................................................................................approx. 2.40 mm
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.45 m
Calculated width.............................................................................................................0.50 m

Example for price calculation:


The room must be completely fitted with sound and heat insulation (Order no.: 20106)
Calculate the surface area to be heated = Size of heating mat (Order no.: 30601...)
Remaining surface area (unheated area) = compensation textile (Order no.: 20107)
Selection and determination of temperature regulator (Order no.: 93088 or 93089)

Calculated width

100 W/m 230 V

Supplied width
Calculated width

Dry installation system


Heating output W

Surface area m

Calculated width m

Length m

Order no.

Price/pce

100
200
300
400
500
600
700
800

1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

2.00
4.00
6.00
8.00
10.00
12.00
14.00
16.00

30601-100
30601-200
30601-300
30601-400
30601-500
30601-600
30601-700
30601-800

130.20
183.00
257.60
316.00
385.30
443.90
552.80
589.40

Sound / heat insulation


Article designation

Width m

Length m

Surfacearea m

Order no.

Price/pce

Fire class B2, thickness 5 mm


Compensation textile

1.00
0.50

10.00
10.00

10.00
5.00

20106
20107

56.50
10.70

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Simply cut and adjust.

Further information
in our installation instructions.

93088

Accessories
Article designation

Order no.

Cold connection cable for extension 3 x 1.00 mm, 1 x 1.00 m

81302-1,00 BL/SW

Price/pce

Mounting sleeve (1, factory fitted), for extension

26121

3.60
6.00

Mounting / repair set with cold connection cable 1 x 5.00 m,


incl. 1 sleeve, for extension

26155

19.00

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.60

Plastic switch socket for room thermostat

20702

0.70

Sensor tube for room thermostat, length: 2.50 m

20703

4.90

Analog point scale regulator with sensor, up to 35 C, flush

93088

93.50

Digital floor regulator, digital with sensor, up to 35 C, flush

93089

114.50

93089

A residual current device (FI < 30 mA) must be provided as a protection measure. Extended cold connection cables cannot be returned.

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

13

Thin-bed heating mats

ALU-Zdry installation

11
H EMSTEDT
ation 20
Inntohinvand superfast
Extra-

ALU-Z thin-bed
heating mat

Sleeveless
splice

Sleeveless, specially developed for laying under laminate


and engineered parquet flooring.
Heating mat with double-end connection cable. The aluminium-coated textile glass fabric
ensures even heat distribution underneath the flooring. The small installation height of only approx. 5 mm + floor makes this product ideal for renovations and for new buildings. Must only be
installed in dry rooms.
The regulation system uses thermostats that are specially adapted to this product.
The HEM dry installation system is manufactured in accordance with VDE 60335-2-96.
Installation (brief description):
A vapour barrier must be installed and fitted if necessary. The room must be fitted with a temperature resistant sound and heat insulation (80 C, B2). The heated area must be fitted with our
HEM dry installation system. Fit floor covering.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................100 W/m
Cold connection cable..................................................................................................1 x 2.50 m / 1 x 6.00 m
Minimum installation temperature.........................................................................5 C
Smallest bending radius..............................................................................................6 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Standard............................................................................................................................60335-2-96
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Heating cable diameter...............................................................................................approx. 2.40 mm
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.45 m
Calculated width.............................................................................................................0.50 m

Calculated width

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Simply cut and adjust.

Further information
in our installation instructions.

100 W/m 230 V


Dry installation system
Heating output W

Surface area m

Calculated width m

Length m

Order no.

Price/pce

100
200
300
400
500
600
700
800

1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

2.00
4.00
6.00
8.00
10.00
12.00
14.00
16.00

30600-100
30600-200
30600-300
30600-400
30600-500
30600-600
30600-700
30600-800

83.50
162.10
219.50
271.50
343.00
399.80
450.20
509.20
Price/pce

Sound / heat insulation

93088

93089

Example for price calculation:


The room must be completely fitted with sound and heat insulation (Order no.: 20106)
Calculate the surface area to be heated = Size of heating mat (Order no.: 30600...)
Remaining surface area (unheated area) = compensation textile (Order no.: 20107)
Selection and determination of temperature regulator (Order no.: 93088 or 93089)

Article designation

Width m

Length m

Surfacearea m

Order no.

Fire class B2, thickness 5 mm


Compensation textile

1.00
0.50

10.00
10.00

10.00
5.00

20106
20107

56.50
10.70

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 1.00 mm, 2 x 1.00 m

81101-1,00 SW

3.10

Mounting sleeve (2, factory fitted), for extension

26123

5.10

Mounting / repair set with cold connection cable 1 x 5.00 m,


incl. 1 sleeve, for extension

26155

19.00

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.60

Plastic switch socket for room thermostat

20702

0.70

Sensor tube for room thermostat, length: 2.50 m

20703

4.90

Analog point scale regulator with sensor, up to 35 C, flush

93088

93.50

Digital floor regulator, digital with sensor, up to 35 C, flush

93089

114.50

A residual current device (FI < 30 mA) must be provided as a protection measure. Extended cold connection cables cannot be returned.

14

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

For underfloor heating systems


Technical data
Nominal voltage
230 V/50 Hz
Switching capacity
16 (2) A
Setting range
+10 C to + 40 C with mechanical
range limitation via setting button
Switching difference
approx. 1.5 K
Display
Heating mode

Temperature reduction
Optional within the control range
(via external switch/pilot timer)
Temperature sensor
NTC 4 m to DIN 44574. Heating is switched off in the
event of sensor failure and short-circuit
Degree of protection
IP 30 degree of protection II after appropriate installation
Housing colour
Similar to RAL 9010 pure white

Temperature regulator

U-UP timer thermostat

Fits into DIN wall sockets, compatible with Busch-Jaeger, Jung, etc.

Timer thermostat
Article designation

Order no.

Price/pce

Hemstedt HEM U intelligent temperature monitoring: Thermostat with selfteach function, programmable, time switch zones, with sensor (digital)

93099

118.10

A residual current device (FI < 30 mA) must be provided as a protection measure.

PA-UP temperature regulator with point scale


For underfloor heating systems
Technical data
Nominal voltage
230 V/50 Hz +-10 % / -15 %
Switching capacity
16 (2) A
Setting range
+10 C to +40 C with mechanical
range limitation via setting button
LED indication
Heating (red) and temperature reduction (green)

Temperature reduction
5K via external switch/pilot timer
Temperature sensor
NTC 4 m to DIN 44574. Heating is switched off in the
event of sensor failure and short-circuit
Degree of protection
IP 30 degree of protection II after appropriate installation
Housing colour
Similar to RAL 9010 pure white

Installation in flush mounted socket via intermediate frame 50 x 50 (to DIN 49075) in virtually all wall sockets.

Thermostat
Article designation

Order no.

PA-UP temperature regulator with point scale and sensor (analog)

93093

Price/pce
96.20

Fits into DIN wall sockets, compatible with Busch-Jaeger, Jung, etc.

P-AP temperature regulator with point scale


For underfloor heating systems
The regulator continuously monitors the floor temperature and regulates the temperature
as required. The floor temperature can be set to the required value by adjusting the knob. A
red LED indicates heating mode. The user can set the oor temperature individually and as
required and irrespective of the room temperature.
Technical data
Nominal voltage
230 V/50 Hz +-6 %
Switch output
10 A at 230 V AC

Settable from
+5 C to +40 C
Temperature sensor
NTC, 4 m

Degree of protection of
housing
IP20

Housing colour
RAL 9010/white
Housing dimensions
70.5 x 70.5 x 21 mm

Thermostat
Article designation

Order no.

P-AP temperature regulator with point scale and sensor (analog)

93098

Price/pce
81.30

A residual current device (FI < 30 mA) must be provided as a protection measure.

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

15

Notes
16

Notes

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Concrete heating mats and concrete heating cables

HEM SYSTEM
Concre te heating mats and concre te
heating cables

17

Concrete heating mats

BH-IM concre te heating mats


Sleeveless, for installation in / under heating screed
HEM SYSTEM Heating mats with single-end connection cable and sleeveless splice.
For underfloor storage / direct heating install only in dry, humid and wet rooms as well as in
flush installations and in screed.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................100 / 120 / 140 / 160 / 180 / 240 W/m
Cold connection cable..................................................................................................1 x 4.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath................................................................................65 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Diameter............................................................................................................................approx. 7.50 mm
Insulation...........................................................................................................................XLPE / PTFE*
Supplied width................................................................................................................0.80 m
Calculated width.............................................................................................................0.90 m

Concrete
heating mat
BH-IM

100 W/m 230 V


BH-IM concrete heating mats
Heating output W
220
300
500
700
1000

Sleeveless
splice

Surfacearea m
2.20
3.00
5.00
6.66
9.52

Calculated width m
0.90
0.90
0.90
0.90
0.90

Length m
2.44
3.33
5.55
7.40
10.58

Order no.
31801-220*
31801-300*
31801-500
31801-700
31801-1000

Price/pce
67.90
81.20
108.80
134.70
178.80

120 W/m 230 V


BH-IM concrete heating mats
Heating output W

Surface area m

Calculated width m

Length m

Order no.

Price/pce

300
400
700
1250
2100

2.49
3.33
5.47
9.77
16.38

0.90
0.90
0.90
0.90
0.90

2.77
3.70
6.08
10.85
18.20

31802-300*
31802-400
31802-700
31802-1250
31802-2100

70.30
87.20
118.90
177.90
280.90

140 W/m 230 V


BH-IM concrete heating mats

Calculated width

Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

300
400
700
1500
2300

2.14
2.85
4.70
10.08
15.48

0.90
0.90
0.90
0.90
0.90

2.38
3.17
5.22
11.20
17.20

31804-300*
31804-400
31804-700
31804-1500
31804-2300

69.90
85.10
116.60
189.50
286.40

160 W/m 230 V


BH-IM concrete heating mats

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

300
500
850
1500
2300

1.94
3.12
5.22
9.18
14.13

0.90
0.90
0.90
0.90
0.90

2.15
3.47
5.80
10.20
15.70

31806-300*
31806-500
31806-850
31806-1500
31806-2300

68.90
87.20
124.50
193.60
292.20

* Insulation PTFE

Simply cut and adjust.

18

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Concrete heating mats

180 W/m 230 V


BH-IM concrete heating mats
Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

292
373
745
1580
1993

1.62
2.07
4.14
8.78
11.07

0.90
0.90
0.90
0.90
0.90

1.80
2.30
4.60
9.75
12.30

31323-292*
31323-373*
31323-745*
31323-1580*
31323-1993*

80.10
91.20
147.80
274.40
338.10

Calculated width m

Length m

Order no.

Price/pce

31324-374*
31324-734*
31324-1351*

76.60
129.40
238.00

240 W/m 230 V


BH-IM concrete heating mats
Heating output W
374
734
1351

Surfacearea m
1.56
3.06
5.63

0.90
0.90
0.90

1.73
3.40
6.25

* Insulation PTFE

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 (1.50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 (2.50 mm),
incl. 1 sleeve for extension

26190

22.50

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Sensor extension 1.00 m

20090

2.00

Concrete
heating mat
BH-IM

A residual current device (FI < 30 mA) must be provided as a protection measure.

Sleeveless
splice

Further information in our installation instructions.


Thermostats see page 15 and 42.

Calculated width

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Simply cut and adjust.


As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

19

Concrete heating cables

BR-IM concre te heating cables


Sleeveless

Concrete heating cables BR-IM

With single-end connection cable and sleeveless splice. Ideal for melting ice and snow in outdoor areas as well as for installation in concrete and sand for melting snow and ice. Likewise
suitable for outdoor areas, e.g. stairways.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................17 W/m
Cold connection cable..................................................................................................1 x 4.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath................................................................................65 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Outer diameter................................................................................................................approx. 7.50 mm
Insulation...........................................................................................................................PTFE to 395 W, XLPE from 400 W

27 W/m
BR-IM concrete heating cables
Heating output W
193
291
395
Sleeveless
splice

Element length m

Order no.

6.90
10.40
14.15

37710-6,90*
37710-10,40*
37710-14,15*

Price/pce
22.40
29.50
37.50

* Insulation PTFE

17 W/m
BR-IM concrete heating cables

Distance bars for concrete heating cables

Heating output W

Element length m

Order no.

Price/pce

400
500
600
700
850
1000
1250
1500
1700
1900
2100
2300
2600
3356
3719
4249

24.77
31.04
34.74
40.59
49.35
58.11
72.71
87.32
99.00
110.69
122.37
134.05
151.58
197.00
218.80
249.00

37710-24,77
37710-31,04
37710-34,74
37710-40,59
37710-49,43
37710-58,11
37710-72,71
37710-87,32
37710-99,00
37710-110,69
37710-122,37
37710-134,05
37710-151,58
37710-197,00**
37710-218,80**
37710-249,00**

44.90
52.20
57.50
60.20
67.60
78.90
88.10
100.00
108.10
120.70
127.50
134.30
140.30
177.40
194.70
216.60

** with shrinkable sleeve.

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 (1.50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 (2.50 mm),
incl. 1 sleeve for extension

26190

22.50

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Distance bars (mounting bars)

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.

Further information in our installation instructions.


Thermostats see page 15 and 42.
20

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Sleeveless
With double-end connection cable and sleeveless splice. Ideal for melting ice and snow in outdoor areas as well as for installation in concrete and sand for melting snow and ice. Likewise
suitable for outdoor areas, e.g. stairways.

Concrete heating cables BR-IM-Z

Concrete heating cables

BR-IM-Z concre te heating cables

Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................17 W/m
Cold connection cable..................................................................................................2 x 2.50 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath...................................................................................... 65 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrink technology
Outer diameter................................................................................................................approx. 7.00 mm
Insulation...........................................................................................................................PTFE up to 410 W, XLPE from 510 W

17 W/m
BR-IM-Z concrete heating cables
Heating output W

Element length m

Order no.

Price/pce

310
410
510
600
700
850
1000
1260
1530
1750
1980
2200
2430
2780

18.07
24.24
30.42
34.55
41.09
49.61
59.15
74.28
89.34
101.88
111.79
124.59
136.06
163.34

37720-18,07*
37720-24,24
37720-30,42
37720-34,55
37720-41,09
37720-49,61
37720-59,15
37720-74,28
37720-89,34
37720-101,88
37720-111,79
37720-124,59
37720-136,06
37720-163,34

30.40
35.60
40.80
43.20
44.80
50.80
58.40
64.70
75.60
82.90
94.80
99.80
105.90
118.20

Sleeveless
splice

Distance bars for concrete heating cables

* Insulation PTFE

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 1 x 1.50 mm, 1.00 m, black

81101-1,50 SW

3.70

Cold connection cable for extension 1 x 2.50 mm, 1.00 m, black

81101-2,50 SW

3.90

Mounting sleeve (1, factory fitted), for extension

26184

5.10

Mounting / repair set with cold connection cable 1 x 5.00 m,


incl. 1 sleeve for extension

26185

19.00

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Distance bars (mounting bars)

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.

Further information in our installation instructions.


Thermostats see page 15 and 42.

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

21

Heating for outdoor areas


22

HEM SYSTEM
Heating mats and cables for outdoor areas
for asphalt, concrete, screed and sand

l!
Practica ical!
Econom

Trouble-free installation, easy handling

Heating for outdoor areas

Safe surfaces for vehicles and paths,


snow and ice free

Paths, bridges, garage entrances, outdoor stairways, ramps, hospital entrances,


heliports - many areas have to be kept free of snow and ice in winter for the safe
movement of vehicles and people.
Hemstedt offers reliable electrical outdoor area heating systems for asphalt,
concrete, screed and sand. They guarantee the reliable melting of snow and ice
and prevent the formation of snow covered and icy surfaces.
The 80 cm wide mats have an effective width of 90 cm and are operated at 230 or 400 V.
The connection load at 7 cm installation depth is 300 W/m, 400 W/m at a greater
depth or in other climatic zones.
Application area: Concrete, screed and sand
The outdoor area heating mats are rugged and designed for installation in concrete
and sand surfaces. A reinforced shakeproof design is available.
Application area: Asphalt
Hemstedt is offering heating mats with a short-time temperature resistance up to
240 C.
The heating cables are also available as fully pre-assembled reels.

Cold connection cable

Sleeveless splice

Heating cable

The sleeveless splice is absolutely waterproof, and therefore ideal for installations
requiring moisture proofing.

Direct from the manufacturer


Factory tested
100 % waterproof
Sleeveless
100 % electrical safety
With single and double end
connection cable

Concrete, screed and sand


Heating mats and concrete heating cables
Concrete heating cables, shakeproof
Asphalt
Asphalt heating mats and asphalt heating cables

Page
24
26
31

23

note:
Pleaseitable for
Only su utdoor use!
winter o

Heating for outdoor areas

BHF-IM heating mats


BRF-IM concrete heating cables
Outdoor area heating, sleeveless

HEM SYSTEM Heating mats and concrete heating cables with single-end connection cable and
sleeveless splice. Only for outdoor areas!!! Ideal for melting ice and snow in outdoor areas as
well as for installation in concrete and sand for melting snow and ice. Not for hot asphalt.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................27 W/m
Cold connection cable..................................................................................................1 x 7.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath (colour red)............................................................. 6 5 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrink technology
Diameter............................................................................................................................approx. 7.50 mm
Insulation...........................................................................................................................XLPE
Supplied width................................................................................................................0.80 m
Calculated width.............................................................................................................0.90 m

Heating mat
BHF-IM

300 W/m 230 V supplied width approx. 0.80 m


BHF-IM heating mats

Sleeveless
splice

Concrete heating
cables
BRF-IM

BRF-IM concrete heating cables

Heat
output W

Surface
area m

Calculated Mat
width m length m

Order no.

Price

Element Order no.


length m

Price/pce

891
1068
1350
1593
1905
2430

2.97
3.56
4.50
5.31
6.35
8.10

0.90
0.90
0.90
0.90
0.90
0.90

31800-891
31800-1068
31800-1350
31800-1593
31800-1905
31800-2430

73.30
83.40
100.30
121.30
135.90
168.90

32.15 m
38.10 m
48.29 m
57.64 m
68.69 m
87.38 m

62.40
70.90
84.90
102.90
114.30
141.60

3.30
3.95
5.00
5.90
7.05
9.00

37731-32,15
37731-38,10
37731-48,29
37731-57,64
37731-68,69
37731-87,38

400 W/m 230 V supplied width approx. 0.80 m


BHF-IM heating mats
Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

891
1068
1350
1593
1905
2430

2.21
2.67
3.38
4.05
4.76
6.08

0.90
0.90
0.90
0.90
0.90
0.90

2.45
2.97
3.75
4.50
5.29
6.75

31850-891
31850-1068
31850-1350
31850-1593
31850-1905
31850-2430

69.90
83.00
85.80
103.30
114.10
136.70

Accessories
Distance bars for concrete heating cables

Calculated width

Supplied width
Calculated width

Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 m (1.50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 (2.50 mm),
incl. 1 sleeve for extension

26190

22.50

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Distance bars (mounting bars)

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Further information in our installation instructions.


Thermostats see page 15 and 42.

Simply cut and adjust.

24

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

BHF-IM-S heating Mats


Outdoor area heating system, sleeveless

Heating for outdoor areas

note:
Pleaseitable for
Only su utdoor use!
winter o

HEM SYSTEM Heating mats with single-end connection cable and sleeveless splice.
Only for outdoor areas!!! Ideal for melting ice and snow in outdoor areas as well as for
installation in concrete and sand for melting snow and ice.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................300 400 W/m
Cold connection cable..................................................................................................1 x 7.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath (colour red)............................................................. 6 5 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrink technology
Diameter............................................................................................................................approx. 7.00 mm
Insulation...........................................................................................................................XLPE
Supplied width................................................................................................................0.50 m
Calculated width.............................................................................................................0.60 m

Heating mat
BHF-IM-S

300 W/m 230 V supplied width approx. 0.50 m


BHF-IM-S heating mats
Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

891
1068
1350
1593
1905
2430

3.00
3.57
4.50
5.40
6.36
8.10

0.60
0.60
0.60
0.60
0.60
0.60

5.00
5.95
7.50
9.00
10.60
13.50

31851-891
31851-1068
31851-1350
31851-1593
31851-1905
31851-2430

71.11
81.64
97.33
117.72
131.44
163.78

Sleeveless
splice

400 W/m 230 V supplied width approx. 0.50 m


BHF-IM-S heating mats
Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

891
1068
1350
1593
1905
2430

2.19
2.58
3.27
3.99
4.65
5.91

0.60
0.60
0.60
0.60
0.60
0.60

3.65
4.30
5.45
6.50
7.75
9.85

31852-891
31852-1068
31852-1350
31852-1593
31852-1905
31852-2430

67.35
80.89
83.49
100.71
110.93
133.42

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 m (1.50 mm),
incl. 1 sleeve for extension

26183

21.00

26190
Order no.
20304

22.50

12.90

Mounting / repair set with cold connection cable 1 x 5.00 (2.50 mm),
incl. 1 sleeve for extension
Plastic fixing nails (standard pack = 100 pcs)

Calculated width

Sensor extension 1.00 m

20090

2.00

Distance bars (mounting bars)

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Further information in our installation instructions.


Thermostats see page 15 and 42.

Simply cut and adjust.


As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

25

note:
Pleaseitable for
Only su utdoor use!
winter o

Heating for outdoor areas

BHF heating mats


BRF concrete heating cables
Outdoor area heating, sleeveless

HEM SYSTEM Heating mats and concrete heating cables with single-end connection cable and
sleeveless splice. Only for outdoor areas!!! Ideal for melting ice and snow in outdoor areas as
well as for installation in concrete and sand for melting snow and ice. Not for hot asphalt.
Technical data
Nominal voltage.............................................................................................................400 Volt
Output................................................................................................................................approx. 37 W/m
Cold connection cable..................................................................................................1 x 7.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath (colour red)............................................................. 65 C 5 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrink technology
Diameter............................................................................................................................approx. 7.50 mm
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.80 m
Calculated width.............................................................................................................0.90 m

Heating mat
BHF

300 W/m 400 V supplied width approx. 0.80 m


BHF heating mats

Sleeveless
splice

Concrete heating cables


BRF

BRF concrete heating cables

Heat
output W

Surface
aream

Calculated
width m

Mat
length m

Order no.

Price/
pce

Element
length m

Order no.

Price/
pce

1068
1350
1554
1878
2322
2862
3321
3726
4158

3.56
4.50
5.18
6.26
7.74
9.54
11.07
12.42
13.86

0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90

3.95
5.00
5.75
6.95
8.60
10.60
12.30
13.80
15.40

31900-1068
31900-1350
31900-1554
31900-1878
31900-2322
31900-2862
31900-3321
31900-3726
31900-4158

121.70
147.10
161.60
188.60
220.40
259.70
295.40
329.10
356.90

28.47 m
36.29 m
41.50 m
50.18 m
62.34 m
76.24 m
89.27 m
99.69 m
110.89 m

37703-28,47
37703-36,29
37703-41,50
37703-50,18
37703-62,34
37703-76,24
37703-89,27
37703-99,69
37703-110,98

103.40
124.50
136.60
159.20
185.20
218.60
247.60
274.00
297.00

400 W/m 400 V supplied width approx. 0.80 m


BHF heating mats

Distance bars for concrete heating cables

Calculated width

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

1068
1350
1554
1878
2322
2862
3321
3726
4158

2.67
3.38
3.89
4.70
5.81
7.16
8.31
9.32
10.40

0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90

2.97
3.75
4.32
5.22
6.45
7.95
9.23
10.35
11.55

31910-1068
31910-1350
31910-1554
31910-1878
31910-2322
31910-2862
31910-3321
31910-3726
31910-4158

109.20
126.00
141.10
155.20
200.60
235.90
271.70
301.00
331.40

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 m (1.50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 (2.50 mm),
incl. 1 sleeve for extension

26190

22.50

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Sensor extension 1.00 m

20090

2.00

Distance bars (mounting bars)

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.

Simply cut and adjust.

26

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

With single-end connection cable and


sleeveless splice

Heating for outdoor areas

note:
Pleaseitable for
Only su utdoor use!
winter o

BHF-S heating Mats

HEM SYSTEM Heating mats with single-end connection cable and sleeveless splice.
Only for outdoor areas!!! Ideal for melting ice and snow in outdoor areas as well as for
installation in concrete and sand for melting snow and ice.
Technical data
Nominal voltage.............................................................................................................400 Volt
Output................................................................................................................................300 400 W/m
Cold connection cable..................................................................................................1 x 7.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath (colour red)............................................................. 65 C 5 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrink technology
Diameter............................................................................................................................approx. 7.50 mm
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.50 m
Calculated width.............................................................................................................0.60 m

Heating mat
BHF-S

300 W/m 400 V supplied width approx. 0.50 m


BHF-S heating mats
Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

1068
1350
1554
1878
2322
2862
3321
3726
4158

3.63
4.62
5.28
6.36
7.92
9.66
11.34
12.66
14.04

0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60

6.05
7.70
8.80
10.60
13.20
16.10
18.90
21.10
23.40

31912-1068
31912-1350
31912-1554
31912-1878
31912-2322
31912-2862
31912-3321
31912-3726
31912-4158

118.66
142.78
156.22
182.49
212.99
251.16
285.07
316.97
344.48

Sleeveless
splice

400 W/m 400 V supplied width approx. 0.50 m


BHF-S heating mats
Heating output W

Surfacearea m

Calculated width m

Length m

Order no.

Price/pce

1068
1350
1554
1878
2322
2862
3321
3726
4158

2.67
3.38
3.90
4.68
5.82
7.11
8.31
9.30
10.38

0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60

4.45
5.63
6.50
7.80
9.70
11.85
13.85
15.50
17.30

31913-1068
31913-1350
31913-1554
31913-1878
31913-2322
31913-2862
31913-3321
31913-3726
31913-4158

106.22
122.71
136.64
150.84
193.82
228.34
263.41
291.58
321.69

Further information
in our installation instructions.

Calculated width

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 m (1.50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 (2.50 mm),
incl. 1 sleeve for extension

26190

22.50

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Sensor extension 1.00 m

20090

2.00

Distance bars (mounting bars)

20063

1.04

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

A residual current device (FI < 30 mA) must be provided as a protection measure.

Simply cut and adjust.


As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

27

Concrete heating cables

BR-IM concre te heating cables


Sleeveless

BR-IM concrete heating cables

With single-end connection cable and sleeveless splice. Ideal for melting ice and snow in outdoor areas as well as for installation in concrete and sand for melting snow and ice. Likewise
suitable for outdoor areas, e.g. stairways.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................17 W/m
Cold connection cable..................................................................................................1 x 4.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath................................................................................65 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Outer diameter................................................................................................................approx. 7.50 mm
Insulation...........................................................................................................................PTFE to 395 W, XLPE from 400 W

27 W/m
BR-IM concrete heating cables
Heating output W
193
291
395
Sleeveless
splice

Element length m

Order no.

6.90
10.40
14.15

37710-6,90*
37710-10,40*
37710-14,15*

Price/pce
22.40
29.50
37.50

* Insulation PTFE

17 W/m
BR-IM concrete heating cables

Distance bars for concrete heating cables

Heating output W

Element length m

Order no.

Price/pce

400
500
600
700
850
1000
1250
1500
1700
1900
2100
2300
2600
3356
3719
4249

24.77
31.04
34.74
40.59
49.35
58.11
72.71
87.32
99.00
110.69
122.37
134.05
151.58
197.00
218.80
249.00

37710-24,77
37710-31,04
37710-34,74
37710-40,59
37710-49,43
37710-58,11
37710-72,71
37710-87,32
37710-99,00
37710-110,69
37710-122,37
37710-134,05
37710-151,58
37710-197,00**
37710-218,80**
37710-249,00**

44.90
52.20
57.50
60.20
67.60
78.90
88.10
100.00
108.10
120.70
127.50
134.30
140.30
177.40
194.70
216.60

** with shrinkable sleeve.

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 (1.50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 (2.50 mm),
incl. 1 sleeve for extension

26190

22.50

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Distance bars (mounting bars)

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.

Further information in our installation instructions.


Thermostats see page 15 and 42.
28

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Sleeveless splice
With double-end connection cable and sleeveless splice. Ideal for melting ice and snow in outdoor areas as well as for installation in concrete and sand for melting snow and ice. Likewise
suitable for outdoor areas, e.g. stairways.

BR-IM-Z concrete heating cables

Concrete heating cables

BR-IM-Z concre te heating cables

Technical data
Nominal voltage............................................................................................ 230 Volt
Output............................................................................................................... 17 W/m
Cold connection cable................................................................................. 2 x 2.50 (1.00 mm)
Minimum installation temperature........................................................ 5 C
Max. temperature outer sheath.....................................................................65 C
Smallest bending radius............................................................................. 5 x dA
Resistance tolerance.................................................................................... -5 % / +10 %
Cold / warm splice ....................................................................................... sleeveless splice, without shrink technology
Outer diameter............................................................................................... approx. 7.00 mm
Insulation.......................................................................................................... PTFE up to 310 W, XLPE from 410 W

17 W/m
BR-IM-Z concrete heating cables
Heating output W

Element length m

Order no.

Price/pce

310
410
510
600
700
850
1000
1260
1530
1750
1980
2200
2430
2780

18.07
24.24
30.42
34.55
41.09
49.61
59.15
74.28
89.34
101.88
111.79
124.59
136.06
163.34

37720-18,07*
37720-24,24
37720-30,42
37720-34,55
37720-41,09
37720-49,61
37720-59,15
37720-74,28
37720-89,34
37720-101,88
37720-111,79
37720-124,59
37720-136,06
37720-163,34

30.40
35.60
40.80
43.20
44.80
50.80
58.40
64.70
75.60
82.90
94.80
99.80
105.90
118.20

Sleeveless
splice

Distance bars for concrete heating cables

* Insulation PTFE

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 1 x 1.50 mm, 1.00 m, black

81101-1,50 SW

3.70

Cold connection cable for extension 1 x 2.50 mm, 1.00 m, black

81101-2,50 SW

3.90

Mounting sleeve (1, factory fitted), for extension

26184

5.10

Mounting / repair set with cold connection cable 1 x 5.00 m,


incl. 1 sleeve for extension

26185

19.00

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Distance bars (mounting bars)

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.

Further information in our installation instructions.


Thermostats see page 15 and 42.

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

29

Heating for outdoor areas

BR-R concre te heating cables


Shakeproof, sleeveless
HEM SYSTEM Heating cables with single-end connection cable and sleeveless splice.
Heating cables can be fastened directly on the reinforcement.
Concrete heating cables BR-R

The installation must only be carried out in concrete structures used for heating outdoor
areas and with temperature monitoring (frost protection only!).
Technical data
Nominal voltage.............................................................................................................400 Volt
Output................................................................................................................................44 W/m
Cold connection cable..................................................................................................1 x 7.00 m
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath................................................................................80 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Outer diameter................................................................................................................approx. 10.50 mm
Insulation...........................................................................................................................PTFE

44 W/m 400 V
BR-R concrete heating cables, shakeproof

Sleeveless
splice

Heating output W

Element length m

Order no.

1469
2037
3100
3613
4044
4507

33.35
46.25
70.40
82.00
91.80
102.30

37790-33,35
37790-46,25
37790-70,40
37790-82,00
37790-91,80
37790-102,30

Price/pce
220.20
282.40
422.00
441.20
484.10
567.60

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26188

7.90

Mounting / repair set with cold connection cable 1 x 5.00 m (1.50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 (2.50 mm),
incl. 1 sleeve for extension

26190

22.50

1 set of sleeves with cold connection cable 5.00 x m

26189

33.10

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Sensor extension 1.00 m

20090

2.00

A residual current device (FI < 30 mA) must be provided as a protection measure.

Further information in our installation instructions.


Thermostats see page 15 and 42.

30

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Heating for outdoor areas

GH mastic asphalt heating mats


GR mastic asphalt heating cables
outdoor area heating system, sleeveless
HEM SYSTEM mastic asphalt heating mats and mastic asphalt heating cables with singleend connection cables can be used for stairways, garage entrances, bridges as well as for
installation in sand and screed.
Technical data
Nominal voltage.............................................................................................................400 Volt
Output................................................................................................................................37 W/m
Cold connection cable..................................................................................................1 x 7.00 (1 00 mm)
Minimum installation temperature.........................................................................5 C
Max. temperature outer sheath................................................................................90 C
Installation temperature.............................................................................................. short term 240 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Diameter............................................................................................................................approx. 8.00 mm
Insulation...........................................................................................................................PTFE
Supplied width................................................................................................................0.80 m
Calculated width.............................................................................................................0.90 m

300 W/m 400 V


GH mastic asphalt heating mats

GR mastic asphalt heating cables

Heat
output W

Surface
aream

Calculated
width m

Mat
length m

Order no.

Price/pce

Element Order no.


length m

Price/pce

1068
1350
1554
1878
2322
2862
3321
3726
4158

3.56
4.50
5.18
6.26
7.74
9.54
11.07
12.42
13.86

0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90

3.95
5.00
5.75
6.95
8.60
10.60
12.30
13.80
15.40

31269-1068
31269-1350
31269-1554
31269-1878
31269-2322
31269-2862
31269-3321
31269-3726
31269-4158

162.10
194.10
216.80
250.50
300.40
358.20
406.30
453.00
492.00

28.47
36.29
41.50
50.18
62.34
76.24
89.27
99.69
110.98

137.70
164.60
182.90
210.40
251.90
298.30
337.30
375.80
411.20

36603-28,47
36603-36,29
36603-41,50
36603-50,18
36603-62,34
36603-76,24
36603-89,27
36603-99,69
36603-110,98

Mastic asphalt
heating mat
GH

Sleeveless
splice

Mastic asphalt
heating cables GR

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

80407-1,00

4.70

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

80407-2,50

5.10

Mounting sleeve (1, factory fitted), for extension

26186

7.00

Mounting / repair set with cold connection cable 1 x 5.00 m (1,50 mm),
incl. 1 sleeve for extension

26128

24.30

Mounting / repair set with cold connection cable 1 x 5.00 m (2,50 mm),
incl. 1 sleeve for extension

26150

29.50

Plastic fixing nails (standard pack = 100 pcs)

20304

12.90

Distance bars (mounting bars)

20063

1.04

A residual current device (FI < 30 mA) must be provided as a protection measure.

Distance bars for mastic asphalt heating cables

Calculated width

Further information in our installation instructions.


Thermostats see page 15 and 42.

Supplied width
Calculated width

Flexible installation
By cutting the
heating mats they
can be adapted
easily to different
building conditions.

Simply cut and adjust.


As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

31

Pipe heating elements Frost protection heating elements


32

HEM SYSTEM
Self-monitoring heating cable for piping
Frost protection heating cable with plug

C ON
at + 5 C OFF
at +15

Plug and heat reliable frost protection

The HEM heating cable is designed for heating metal or plastic water pipes that are
subject to freezing down to -20 C. It is self-monitoring, prevents impermissible
cooling and general frost damage, and ensures a minimum temperature, e.g. for
the supply of drinking water to animals outdoors and in stables. A thermostat
monitors the point on the pipe suspected of having the lowest temperature. For
frost protection the heating cable is activated at + 5 C and is deactivated when the
temperature exceeds + 15 C. Benefit: The required electrical energy is automatically kept to a minimum.

All in one: Fitted quickly and effortlessly

Thermostat

Mounting band

Insulation

Heating cable

Mounting band
Insulation

The HEM SYSTEM heating cable is fixed loosely with slight bends, preferably along
the bottom of the pipe. At locations requiring additional energy such as valves, some
loosely placed windings of the heating cable for the required energy supply.
The cable is fixed with adhesive aluminium tape or loosely fitted with temperature
resistant plastic cable binders. Plastic pipes must be wrapped beforehand in
aluminium foil.
An industry standard heat insulation layer at least 20 mm thick not only guarantees
the functioning of the heating cable but also reduces the heat requirement.
Simply plug in and frost protection is guaranteed.

Pipe heating elements Frost protection heating elements

A minimum of energy
for the maximum in frost protec tion

Cold connection cable

Sleeveless splice

Plug

Heating cable

The sleeveless splice is absolutely waterproof and therefore ideal for installations
requiring moisture proofing.

Direct from the manufacturer


Factory tested
100 % waterproof
Sleeveless
Ready to plug
100 % electrical safety
VDE approval
With single-end connection cable
Frost protection heating elements
FS Frost protection heating element
with temperature regulator and earthed plug

Page
34

FSE frost protection heating element export variant

35

F Frost protection heating element


without temperature regulator and without earthed plug
FE frost protection pipe heating element
without temperature regulator and without earthed plug

36
37
33

Pipe heating elements Frost protection heating elements

FS frost protection pipe heating element


With temperature regulator and earthed plug

Frost protection pipe heating element FS

Heating cable with single-end cold connection cable, earthed plug and temperature regulator,
+5 C On / +15 C Off; 10 W/m HEM SYSTEM heating cables installed along water pipes
prevent impermissible cooling and also protect the supply of drinking water to animals outdoors and in stables.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................approx. 10 W/m
Cold connection cable..................................................................................................1 x 2.00 m
Minimum installation temperature.........................................................................5 C
Nominal temperature...................................................................................................65 C
Temperature regulator 16 A.......................................................................................+5 C On / +15 C OFF
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Approval (heating cable).............................................................................................VDE
Cold/warm splice............................................................................................................sleeveless
Outer diameter................................................................................................................approx. 9.00 mm

approx. 10 W/m

Sleeveless
splice

FS frost protection heating element, ready to connect


Voltage V
Output W
Length m

kg/reel

Order no.

Price/pce

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

0.26
0.32
0.40
0.48
0.55
0.60
0.68
0.75
0.80
0.90
1.07
1.20
1.47
1.77
1.86
2.24
2.24
2.70
3.50
3.66
4.02

35602-01
35602-02
35602-03
35602-04
35602-05
35602-06
35602-07
35602-08
35602-09
35602-10
35602-12
35602-14
35602-18
35602-22
35602-24
35602-28
35602-32
35602-36
35602-48
35602-50
35602-60

43.10
47.50
50.60
55.20
58.60
61.30
64.80
68.70
73.30
75.20
78.90
86.20
93.40
99.40
109.90
113.90
124.40
140.70
188.00
195.80
235.30

10
20
30
40
50
60
70
80
90
100
120
140
180
220
240
280
320
360
480
500
600

1
2
3
4
5
6
7
8
9
10
12
14
18
22
24
28
32
36
48
50
60

Accessories
Article designation

Order no.

Price/pce

Aluminium mounting band

20084

31.80

Sign with text "Electrically heated

20085

1.30

Meshed band

20086

21.40

A residual current device (FI < 30 mA) must be provided as a protection measure.

34

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

With temperature regulator and earthed plug


Heating cable with single-end cold connection cable, earthed plug and temperature regulator,
+5 C On / +15 C Off; 17 W/m HEM SYSTEM heating cables along water pipes
prevent impermissible cooling and also protect the supply of drinking water to animals outdoors and in stables.

nt
a
i
r
a
v
t
r
Expo
Frost protection pipe heating element FSE

Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................approx. 17 W/m
Cold connection cable..................................................................................................1 x 2.00 m
Minimum installation temperature.........................................................................5 C
Nominal temperature...................................................................................................65 C
Temperature regulator 16 A.......................................................................................+5 C On / +15 C OFF
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold/warm splice connection....................................................................................sleeveless
Outer diameter................................................................................................................approx. 9.00 mm

Pipe heating elements Frost protection heating elements

FSE frost protection pipe heating element

approx. 17 W/m
FSE frost protection heating element, ready to connect
Voltage V
Output W
Length m

kg/reel

Order no.

Price/pce

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

0.26
0.32
0.40
0.48
0.55
0.60
0.68
0.75
0.80
0.90
1.07
1.20
1.47
1.77
1.86
2.24
2.24
2.70
3.50
3.66
4.02

35606-01
35606-02
35606-03
35606-04
35606-05
35606-06
35606-07
35606-08
35606-09
35606-10
35606-12
35606-14
35606-18
35606-22
35606-24
35606-28
35606-32
35606-36
35606-48
35606-50
35606-60

45.60
50.10
53.20
57.80
61.20
63.90
67.40
71.30
75.90
77.80
81.50
88.80
92.70
101.90
112.50
116.40
108.40
143.20
190.50
198.40
237.80

17
34
51
68
85
102
119
136
153
170
204
238
306
374
408
476
544
612
816
850
1020

1
2
3
4
5
6
7
8
9
10
12
14
18
22
24
28
32
36
48
50
60

Sleeveless
splice

Accessories
Article designation

Order no.

Price/pce

Aluminium mounting band

20084

31.80

Sign with text "Electrically heated

20085

1.30

Meshed band

20086

21.40

A residual current device (FI < 30 mA) must be provided as a protection measure.

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

35

Pipe heating elements Frost protection heating elements

F frost protection pipe heating element


Without temperature regulator and without earthed plug

Frost protection pipe heating element F

Heating cable with single-end connection cable. HEM SYSTEM Heating cables without fixed
connection in conjunction with controller and temperature sensor, layed along water pipes,
prevent impermissible cooling and also protect the supply of drinking water to animals outdoors and in stables.
Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................approx. 10 W/m
Cold connection cable..................................................................................................1 x 2.00 m
Minimum installation temperature.........................................................................5 C
Nominal temperature...................................................................................................65 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Outer diameter................................................................................................................approx. 9.00 mm

approx. 10 W/m

Sleeveless
splice

F frost protection heating element


Voltage V
Output W

Length m

Order no.

Price/pce

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

1
2
3
4
5
6
7
8
9
10
12
14
18
22
24
28
32
36
48
50
60

35600-01
35600-02
35600-03
35600-04
35600-05
35600-06
35600-07
35600-08
35600-09
35600-10
35600-12
35600-14
35600-18
35600-22
35600-24
35600-28
35600-32
35600-36
35600-48
35600-50
35600-60

40.00
44.10
47.00
50.80
54.00
56.70
59.60
63.00
66.20
68.70
72.10
79.40
87.80
94.50
102.50
107.30
113.50
128.20
171.20
178.40
214.60

10
20
30
40
50
60
70
80
90
100
120
140
180
220
240
280
320
360
480
500
600

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 m (1,50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 m (2,50 mm),
incl. 1 sleeve for extension

26190

22.50

Aluminium mounting band

20084

33.60

Sign with text "Electrically heated

20085

1.30

Meshed band

20086

21.40

Control box 0 C up to +80 C 2000 W / 230 V with analog regulator


incl. 10.00 m sensor

98406

362.90

Spare sensor 10.00 m

94010

28.10

Distance bars (mounting bars)

20063

1.04

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.70

A residual current device (FI < 30 mA) must be provided as a protection measure.

36

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Without temperature regulator and without earthed plug

riant
a
v
t
r
o
p
Ex

Heating cable with single-end connection cable. HEM SYSTEM Heating cables without fixed
connection in conjunction with controller and temperature sensor, layed along water pipes,
prevent impermissible cooling and also protect the supply of drinking water to animals outdoors and in stables.

Frost protection pipe heating element FE

Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................approx. 17 W/m
Cold connection cable..................................................................................................1 x 2.00 m
Minimum installation temperature.........................................................................5 C
Nominal temperature...................................................................................................65 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Outer diameter................................................................................................................approx. 9.00 mm

approx. 17 W/m
FE frost protection heating element
Voltage V
Output W

Length m

Order no.

Price/pce

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

1
2
3
4
5
6
7
8
9
10
12
14
18
22
24
28
32
36
48
50
60

35603-01
35603-02
35603-03
35603-04
35603-05
35603-06
35603-07
35603-08
35603-09
35603-10
35603-12
35603-14
35603-18
35603-22
35603-24
35603-28
35603-32
35603-36
35603-48
35603-50
35603-60

42.40
45.30
48.70
53.60
55.80
58.40
61.70
64.10
69.30
71.50
74.80
83.60
89.30
96.40
104.10
109.90
119.20
131.30
178.50
182.50
222.70

17
34
51
68
85
102
119
136
153
170
204
238
306
374
408
476
544
612
816
850
1020

Pipe heating elements Frost protection heating elements

FE frost protection pipe heating element

Sleeveless
splice

Accessories
Article designation

Order no.

Price/pce

Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black

81302-1,50 BL/SW

4.10

Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black

81302-2,50 BL/SW

4.60

Mounting sleeve (1, factory fitted), for extension

26182

5.30

Mounting / repair set with cold connection cable 1 x 5.00 m (1,50 mm),
incl. 1 sleeve for extension

26183

21.00

Mounting / repair set with cold connection cable 1 x 5.00 m (2,50 mm),
incl. 1 sleeve for extension

26190

22.50

Aluminium mounting band

20084

33.60

Sign with text "Electrically heated

20085

1.30

Meshed band

20086

21.40

Control box 0 C up to +80 C 2000 W / 230 V with analog regulator


incl. 10.00 m sensor

98406

362.90

Spare sensor 10.00 m

94010

28.10

Distance bars (mounting bars)

20063

1.04

Cu end seal sensor (OD 15.20 mm / ID 12.50 mm)

20079

6.70

A residual current device (FI < 30 mA) must be provided as a protection measure.

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

37

Roof gutter heating

HEM SYSTEM
DAS roof gut ter heating
Heating cable with thermostat for protection from snow and ice

Edge guard

ss
Sleevele
splice,
ly
absolute f
roo
waterp

ant
al-resist
Chemic lating
su
in
TFE
P
g
coverin

>1m

Thermostat

DAS roof gutter heating

38

Plug, ready-to-use.
Designed for 230 V AC

Roof gutter heating

HEM SYSTEM
Heating cable with thermostat
Safety for persons and building

Ice on buildings, roof gutters and roof surfaces forms up in winter due to heat
losses on buildings and poor exposure to sunlight. The resulting condensation
water cannot flow away and freezes. HEM SYSTEM DAS roof gutter heating
systems keep the areas at risk reliably free from snow and ice thus preventing:
Formation of icicles (danger to persons and property)
Bursting downpipes
Freezing of downpipes in frost area (ground)
Water penetration into buildings
Damage to external facades

All in one: Fitted quickly and effortlessly


Plug, ready-to-use. With sleeveless splice and chemical-resistant PTFE insulating
covering. HEM SYSTEM DAS roof gutter heating systems have multiple uses for
pitched roof areas, semi-circular and box gutters and downpipes. Installation is
simple, the electrical connection can also be carried out by unqualified persons. The
plug is already made up.
For normal semi-circular gutters, the expected energy consumption is approx. 50 to
60W/m per meter of guttering. This also applies to downpipes that have to be heated
up to the frost limit (approx. 1 m in ground area).
Important: When calculating the requirement and length, remember that the heating
cable may have to be applied several times.

Cold connection cable

Sleeveless splice

Heating cable

The sleeveless splice is absolutely waterproof, and therefore ideal for installations
requiring moisture proofing.

Direct from the manufacturer


Factory tested
100 % waterproof
Sleeveless
Ready to plug
100 % electrical safety

Roof gutter heating


Roof gutter heating
Alarms and regulators
Ice and snow alarms
Frost alarms and regulators

Page
40
42
42

39

Roof gutter heating

DAS roof gut ter heating


With temperature regulator and earthed plug
HEM-SYSTEM DAS roof gutter heating with single-end connection cable, sleeveless splice and
chemical-resistant PTFE insulating covering.
DAS roof gutter heating

Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................approx. 30 W/m
Cold connection cable..................................................................................................1 x 4.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Nominal temperature acc. VDE 0253......................................................................90 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Outer diameter................................................................................................................approx. 8.20 mm
Insulation...........................................................................................................................PTFE

approx. 30 W/m

Sleeveless
splice

DAS roof gutter heating


Voltage V
Output W

Length m

Order no.

Price/pce

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

4
5
6
10
12
14
16
20
23
30
35
41
49
55
70

38613-04
38613-05
38613-06
38613-10
38613-12
38613-14
38613-16
38613-20
38613-23
38613-30
38613-35
38613-41
38613-49
38613-55
38613-70

70.10
72.60
74.80
86.40
91.40
103.50
113.20
121.00
137.20
164.50
177.50
197.90
217.80
241.10
302.90

120
151
196
293
367
419
471
627
700
919
1103
1265
1440
1719
2062

Accessories
Distance bars for roof gutter heatings

Article designation

Order no.

Price/pce

Cross-beam, stainless steel (only roof gutter heating)

20075

9.80
3.50

Cord grip, stainless steel (only roof gutter heating)

20076

Cord grip, copper (only roof gutter heating)

20070

3.60

Support cable (only roof gutter heating)

20074

0.80

Distance bars (mounting bars)

20063

1.04

Roof cable holder for tiled roof

20100

10.10

Roof cable holder for seam roof, galvanised

20101

11.70

Roof cable holder for seam roof, copper

20102

47.30

Edge guard

20103

4.00

Socket for outdoor area, IP44

20104

13.10

A residual current device (FI < 30 mA) must be provided as a protection measure.

40

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Roof gutter heating

DA roof gut ter heating

HEM-SYSTEM DA roof gutter heating with single-end connection cable, sleeveless splice and
chemical-resistant PTFE insulating covering. Also suitable for outdoor areas, e.g. stairways.
DA roof gutter heating

Technical data
Nominal voltage.............................................................................................................230 Volt
Output................................................................................................................................approx. 30 W/m
Cold connection cable..................................................................................................1 x 4.00 (1.00 mm)
Minimum installation temperature.........................................................................5 C
Nominal temperature acc. VDE 0253......................................................................90 C
Smallest bending radius..............................................................................................5 x dA
Resistance tolerance.....................................................................................................-5 % / +10 %
Cold / warm splice ........................................................................................................sleeveless, without shrinkable sleeve
Outer diameter................................................................................................................approx. 8.20 mm
Insulation...........................................................................................................................PTFE

approx. 30 W/m
DA roof gutter heating
Voltage V

Output W

Length m

Order no.

Price/pce

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

120
151
196
293
367
419
471
627
700
919
1103
1265
1440
1719
2062

4
5
6
10
12
14
16
20
23
30
35
41
49
55
70

38612-04
38612-05
38612-06
38612-10
38612-12
38612-14
38612-16
38612-20
38612-23
38612-30
38612-35
38612-41
38612-49
38612-55
38612-70

57.10
59.50
61.80
73.40
78.40
90.50
100.10
107.90
124.00
151.20
164.30
184.70
204.30
227.80
289.60

OrderOrder
no. no.
81302-1,50 BL/SW
81302-2,50 BL/SW
91116
26182

Price/pce
4.10
4.60
38.10
5.30

26183

21.00

Sleeveless
splice

Accessories
Article designation
Cold connection cable for extension 3 x 1.50 mm, 1.00 m, black
Cold connection cable for extension 3 x 2.50 mm, 1.00 m, black
Capillary tube regulator 0C to 55C / 16 A / 250 V~
Mounting sleeve (1, factory fitted), for extension
Mounting / repair set with cold connection cable 1 x 5.00 m (1,50 mm),
incl. 1 sleeve for extension
Mounting / repair set with cold connection cable 1 x 5.00 m (2,50 mm),
incl. 1 sleeve for extension
Cross beam, stainless steel (only roof gutter heating)
Cord grip, stainless steel (only roof gutter heating)
Cord grip, copper (only roof gutter heating)
Support cable (only roof gutter heating) per m
Distance bars (mounting bars)
Digital ice and snow alarm for universal use
Ice sensor 6.0 m, can be extended up to max. 50 m
Frost alarms and regulators for roof gutter heating
Alternative to order no.93159
1.00 m sensor extension for ice sensor
1 sleeve for sensor
Factory fitted installation sleeve (1 pce)
Roof cable holder for tiled roof
Roof cable holder for seam roof, galvanised
Roof cable holder for seam roof, copper
Edge guard

26190

22.50

20075
20076
20070
20074
20063
93159
93156

9.80
3.50
3.60
0.80
1.04
216.80
111.30

93160
20099
26185
26121
20100
20101
20102
20103

105.90
3.60
3.10
6.00
10.10
11.70
47.30
4.00

Distance bars for roof gutter heatings

A residual current device (FI < 30 mA) must be provided as a protection measure.
As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

41

Temperature regulator

DES ice and snow alarm


Digital
Used in conjunction with one or two combined moisture and temperature sensors, the digital
ice and snow alarm has the task of detecting ice and snow early on and keeping the monitored
areas clear by switching on a melting device.
Technical data
Nominal voltage......................................................................................1/N/AC, 50 Hz, 230 V, to DIN EN 60730
Voltage range...........................................................................................230 V +6/-6 %
Rated output.............................................................................................approx. 10 VA

Load max. 250 V~, 6 (2) A
Ambient temperature............................................................................0 to 50 C, condensation not permissible
Degree of protection.............................................................................II to DIN 57700,
.......................................................................................................................when mounted in distribution panel
*Weight.......................................................................................................approx. 0.4 kg

DES ice and snow alarm


Article designation
Digital ice and snow alarm
(for roof gutters and outdoor areas)
Moisture and temperature sensor (for roof gutters)
Ice sensor with 6.00 m supply cable, cable entry from bottom,
with protective housing (for outdoor area)
Ice sensor with 6.00 m supply cable, cable entry from side
(for outdoor area)

Order no.

Price/pce

93159
93156

216.80
111.30

93164

209.70

93162

199.10

A residual current device (FI < 30 mA) must be provided as a protection measure.

FR frost alarm and regulator


For roof gutter heating
This device is a practical / cost-effective alternative to the digital ice and snow alarm and
is used for the economical control of roof gutter heating. The critical temperature range is
monitored by two regulators so that the heating is only in operation when there is actually a
risk of freezing. Heating is only activated in the critical range from -5 C to +5 C.

Technical data
Rated voltage............................................................................................230 V AC
Switch current..........................................................................................16 (4) A
Ambient temperature............................................................................-30 to +50 C
Temperature range.................................................................................-20 to -35 C
Degree of protection.............................................................................IP 65
Dimensions................................................................................................122 x 120 x 55 mm
Contact........................................................................................................1 NC / 1 NO

FR frost alarm and regulator


Article designation

Order no.

Price/pce

Frost alarms and regulators for roof gutter heating

93160

105.90

A residual current device (FI < 30 mA) must be provided as a protection measure.

42

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

As of 03 /11. Subject to alterations. All prices not including VAT.

Notes

Notes

www.hemstedt.com

43

Farming and gardening

HEM SYSTEM
HEATING SOLUTIONS FOR FARMING AND GARDENING
Heating cable with thermostat for protection from snow and ice

Underfloor heating for animal husbandry

PTFE slug stop heating

44

Underfloor heating for poly-tunnels and greenhouses

Farming and gardening

Economical heating cables


for flexible use
Favourable solutions for increased yield

Underfloor heating for animal husbandry


Modern agricultural units increasingly recognise the financial benefits of electrical
underfloor heating and trough heating for their livestock. This particularly applies to
pig farming, where the partial heating of the sty floor reduces the loss of piglets and
is considerably more economical than the use of red lights. Hemstedt heating cables
comply with the requirements for buildings used for farming and can be layed simply
in the screed. A unique benefit: The sleeveless, 100 % tight splice prevents the
penetration of aggressive waste water and thus any resulting faults.

Underfloor heating for poly-tunnels and greenhouses


The use of heating cables is becoming an increasing necessity for professional plant
growing and propagation. Ask us about our solutions and products.

SH-S Sophie and SH-A Alessa PTFE slug


stop heating set *
HEM slug stop heating system with single-end connection cable and PTFE insulation.
Particularly affordable price in relation to the used floor space. Teflon heating
self-cleaning as known from the kitchen.
Depending on heating cable length, the Sophie set contains:
HEM slug stop heating with single-end connection cable
Transformer
Screws (4 x 20 mm)
Clips ( 5 mm)
Brackets (8 pce.) for mounting
Weather protection for transformer (not shown, colour variable)
Wooden frame

SH-S PTFE Sophie slug stop heating


Transformer Transformer
Heating output
V
VA
W
230/24
180
106
230/24
180
138
230/24
180
170
230/24
250
202
SH-A PTFE Alessa slug stop heating
Transformer
Transformer
V
VA
230/24
180
230/24
180
230/24
180
230/24
250

Heating cable
m
3.30
4.30
5.30
6.30

Heating output W
106
138
170
202

Wooden frame
cm
75 x 75
100 x 100
125 x 125
150 x 150

Heating cable
m
3.30
4.30
5.30
6.30

Order no.

Price/pce

38020-3,3
38020-4,3
38020-5,3
38020-6,3

144.77
151.11
161.10
178.98

Order no.

Price/pce

38022-3,3
38022-4,3
38022-5,3
38022-6,3

112.67
119.51
126.42
140.85

* The Alessa and Sophie sets both without wooden frame

45

Sports areas
46

HEM SYSTEM
HEATING SOLUTIONS FOR SPORTS AREAS

For all-year use

Sports areas

HEATING CABLE FOR GRASS AREAS IN


STADIUMS AND SPORTS GROUNDS

Soil heating with Hemstedt cables


The management and people responsible for sports grounds such as football
stadiums or golf courses are increasingly using soil heating systems.
The hard frozen ground is thawed, melting any snow covering and lengthening grass
growth. Sporting activities can thus take place all year round, the season lengthened,
as well as ensuring that the ground is dried out faster after heavy precipitation. The
risk of injury to players is also considerably reduced.
Compared to warm water heating systems, electrical soil heating systems offer
considerable benefits such as lower investment and running costs, faster operation
and greater efficiency. Hemstedt heating cables are optimally designed for these
demanding requirements. They can be used for heating any grass area. Depending on
the heating requirement, cables with a 15 20 Watt/m output for 230 V or 400 V are
available that are designed for the toughest weather conditions.

Technical data
Rated voltage............................................................................................400 V
Cold connection cable...........................................................................approx. 2 x 30 m (2,50 mm)
Minimum installation temperature..................................................5 C
Smallest bending radius.......................................................................6 x dA

Element length of e.g. approx. 200 m is also available with cold connection cable
and splice.

47

Distance bars

D distance bars
For fixing heating cables
D distance bars

Heating mats can be created with distance bars.


A variable Watt/m2 heating mat production is possible depending on the grid dimensions of the
distance bars.
Examples: Heating mats, heating cables, heating loops.

Distance bars
Article
designation
MS-1 distance bars
MS-2 distance bars
MS-3 distance bars
MS-4 distance bars

Length
m
~ 1.00
~ 1.00
~ 1.00
~ 1.00

Grid
mm
20
25
25
25

Cable
diameter mm
38613-04
38613-05
38613-06
38613-10

Bar width
mm
8
8
8
8

Order no.

Price/pce

20060
20061
20062
20063

1.04
1.04
1.04
1.04

Examples:
Heating mats
Heating cables
Heating loops

Distance bars

Roof gutter

48

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

As of 03 /11. Subject to alterations. All prices not including VAT.

Notes

Notes

www.hemstedt.com

49

Notes
50

Notes

As of 03 /11. Subject to alterations. All prices not including VAT.

www.hemstedt.com

Prices
All prices are quoted excluding VAT and other charges.

Delivery
Goods shall be delivered at the purchasers risk.

Terms of payment
Unless other terms of payment have been agreed, the invoice sum is
payable without deduction within 14 days of the date of the invoice.

The latest version of our general terms and conditions apply in


addition to this extract.
See: www.hemstedt.com (as of 2011)

Worldwide: Direct
As a global player, Hemstedt GmbH supplies and looks
after customers and projects together with overseas
agents on all continents, directly from the headquarters
in Brackenheim.

Hemstedt GmbH
Schleicherweg 19
D-74336 Brackenheim
Phone: +49 (0) 7135 / 9898-0
Fax:
+49 (0) 7135 / 2197
Mail: office@hemstedt.de
Web: www.hemstedt.com

You might also like