Generator Set Specifications


Model Name Rating 50 Hz Standby Prime Continuous Rating 60 Hz Standby Prime Continuous Standard Dimensions [mm] Dry Weight [kg] Painting

BMGS 1740.Containerized
1905.0 KVA / 1524.0 KW 1740.0 KVA / 1392.0 KW 1560.0 KVA / 1248.0 KW 2040.0 KVA / 1632.0 KW 1845.0 KVA / 1476.0 KW 1570.0 KVA / 1256.0 KW 5300 x 2590 x 3104 [ L x W x H ] 13.300 Neon Blue .245 - 7432 Space Black .245 - 2852

General
Applicable Condition Ambient Temperature Altitude Place of Installation 5 - 40 Up to 1500 meters above sea level In Door

Shop Test [Diesel engine running test shall be carried out by the following items] Starting Test 10 minutes Load Test Standard BMJ Governor Test Governor Test should be done along with respective governor control Safety stop device test Standard BMJ

Diesel Engine Data


Principal Particulars Engine Model Type No of cylinders Arrangement Bore x Stroke [mm] Displacement Total [ltr] Compression ratio Combustion system Lubricating Oil Fuel Consumpion [Allowance +5%] Standard Engine Equipment Power Line System Flywheel Flywheel Housing Engine Mounting Air Intake System Air Cleaner Turbocharger Charge Air Cooler Intake Air Flow S16R PTA 4 cycle, water cooled, turbocharged with after cooler 16 cylinders V Type 170 x 180 65.37 14.0 : 1 Direct Injection CD Class or CF Class [ API Service classification ] SAE 30 or SAE 40 204 gr/kwh at 1500 rpm [Prime Rating] 213 gr/kwh at 1800 rpm [Prime Rating]

SAE J620C. 21 in except screw size SAE J617b. No.00 except screw size Rubber Type

Paper element type Donaldson FTG13L X 4 pcs Paper element type with screen cap Mitsubishi TD Type Jacket Water cooled type Plated element type 4131 cfm 1500 rpm [Prime Rating] 4484 cfm 1800 rpm [Prime Rating]

Exhaust System Exhaust Manifold Breather Max back pressure

Air Cooled type with heat insulator Up side direction type [For Blow off to outside of engine room] 600 mm H2O or 23.6 In H2O

DGS/BMJ-ENG/2010

Page 1

www.bmj.co.id
Lubricating System Oil Pump Capacity Oil Pump Lube oil pressure Max oil temperature Quantity of oil [approx] Cooling System Water Pump Capacity of water pump Max coolant temp Max cooling air temp Coolant Flow Coolant capacity Fuel System Injection Pump Max Section head Fuel filter Control System Governor Actuator Magnetic Pick Up Starting System Starting motor Alternator Fuel limit Solenoid Gear pump type 480 liters/min at 1500 rpm 580 liters/min at 1800 rpm 4.0 6.5 kg/cm 110 230 liters

Gear drive centrifugal pump 1650 liters at 1500 rpm 1850 liters at 1800 rpm 98 40 [ TAA type ] 1650 liters/min 1500 rpm [Prime Rating] 1850 liters/min 1800 rpm [Prime Rating] 445 liters

Bosch type PS8 X 2 75 mm Hg [of feed pump] Paper element cartridge type

Electronic Speed Governor [Toho XS.400B] Speed Droop 0 5% adjustable DC24V 20% Current Consumption With 2 pole connector

DC24V, 7.5KW X 2 pcs DC24VDC, 30 A with voltage regulator Fuel limit at engine starting Energize to fuel control until rated speed

Safety Device Low oil pressure High Water temperature Over speed

< 1.5 kg/cm > 98 +10% from rated speed

Noise Level [1 mtr height and distance] 109 dB [A] 1500 rpm [Prime Rating] 109 dB [A] 1800 rpm [Prime Rating] Standard Instruments Lubricating oil pressure gauge, Lubricating oil temperature gauge, Exhaust gas temperature gauge, Tachometer.

Generator Data
Model Type Phase Pole Temp Rise Voltage Star Voltage Regulation AVR Type Insulation System Protection Rated Power Factor Stator Winding Winding Pitch Winding Leads Stator Wdg Resistance Rotor Wdg Resistance RFI Suppression Waveform Distortion Max overspeed Newage Generator Stamford PI 734 E 3 4 125 240V/415V 0.5% with 4% engine governor MX.321 Class H IP23 0.8 Double Layer Trap Two Thirds 6 0.00093 Ohms / Phase at 22 Star Conection 1.65 Ohms at 22 BS EN 61000-6-2 and BS EN 61000-6-4, VDE0875G, VDE0875N No Load < 1.5% Non distorting balanced linear load < 5.0% 2250 Rev / Min

DGS/BMJ-ENG/2010

Page 2

www.bmj.co.id
Bearing Drive End Bearing Non Drive End Coupling Type Weight Comp Gen Weight Wound Stator Weight Wound Rotor WR Inertia Shipping Weight Telephone Interface Cooling Air Ball 6228 [ ISO ] Ball 6319 [ ISO ] Single Bearing 3541 kg 1852 kg 1494 kg 45.5872 kgm 3614 kg [Gross] THF <2% 2.64 m / sec 5600 cfm

Control Panel DGCP 2000, DGCP 2001, DGCP 2002

Standard DGCP 2000


Model DGCP 2000 [ Analog ] The keys unit provides for the manual starting and stopping of the generator with automatic monitoring and shutdown of the engine in the event of a low oil pressure, high water temperature and over speed. Control of the unit is by 3 positions keys switch on the front display, operating between STOP, RUN and START position. Indoor type mounted on the Skid Base IP54 Voltmeter, Ammeter, Phase Selector, Frequency meter, Operating Hour meter, Tachometer, Ammeter Selector, Speed Adjuster, Oil Press Gauge, Oil Temp Gauge, Water Temp Gauge, Emergency Stop, Keys Start, Charging Indicator Lamp, LOP Lamp, HWT Lamp, DC On, Over Speed Lamp, Engine Stop. Low Oil Pressure, High Water Temperature, Oil Filter Pre alarm, Over speed Manual Start Stop with Key Switch

Type panel structure Protection Instrument Standard

Protection Device Control System

Standard Equipment
Industrial Silencer Material Exhaust Flexible Battery Battery Cable Battery Rack Flexible Fuel Line Tool Exhaust Thermometer IS 355 / 14 Steel Plate Tch. 4 / Pipe Sch.40 [ Flange JIS Std ] EF 355 / 14 [ Stainless Steel material with flange JIS Std ] 24 Volt DC 95 mm x 1.5 mtr x 4pcs 95 mm x 0.5 mtr x 2pcs Standard Inlet and Return mounted on the DG [included fuel valve] Standard Tool YKS-600, 100 - 650

Optional 1. DGCP 2001


Model DGCP 2001 [ Analog and Digital ] The DGCP 2001 provides the control features for the automatic or manual starting and shutdown of the generator. The unit is a microprocessor based controller, giving full programmability of timer, trip level and control option, with 17 front fascia LEDs for the indication of generator status and fault. The unit provides all the control features of the DGCP 2001 unit but in addition offers an over speed shutdown, an under speed shed load function and a fail to start fault as standard. Indoor type mounted on the Skid Base IP54 Voltmeter, Ammeter, Phase Selector, Frequency meter, Operating Hour meter, Tachometer, Ammeter Selector, Speed Adjuster, Oil Press Gauge, DC Volt, Water Temp Gauge, Emergency Stop, Keys Start, Charging Indicator Lamp, LOP Lamp, HWT Lamp, DC On, Over Speed Lamp, Engine Stop.

Type panel structure Protection Instrument Standard

DGS/BMJ-ENG/2010

Page 3

www.bmj.co.id
Protection Device Low Oil Pressure, High Water Temperature, Over speed / Over HZ, Open circuit Oil and Temperature sensing, Under Speed / Under Hz, Lost AC signal, HZ Fail, Run Failure, Stop Failure. Warning indicate, Excitation warning, Charger warning, Low Battery warning, Trip Lock warning Automatic or manual Start Stop

Control System

2.

DGCP 2002
Model DGCP 2002 [ Digital ] The DGCP 2002 provides for the fully automatic or manual control of a standby generator whilst also allowing for remote monitoring through the use of a customer supplied modem. The unit has similar control to the DGCP 2002 including 4 inputs and 4 outputs but with the addition of 3 phase generator voltage and current measurement, display and fault tripping. The unit also offers shutdowns as standard for over frequency, under frequency, under voltage and over current. Complete with display for displaying, 15 instruments, Error message and programming and useful signals for generator set management. Indoor type mounted on the Skid Base IP54 Voltmeter, Ammeter, Frequency meter, Operating Hour meter, Tachometer, Speed Adjuster, Oil Press Gauge, DC Volt, Water Temp Gauge, Emergency Stop, Charging Indicator Lamp, Low Oil Pressure, High Water Temperature, Over speed / Over HZ, Open circuit Oil and Temperature sensing, Under Speed / Under Hz, Lost AC signal, HZ Fail, Run Failure, Stop Failure, Under / Over Voltage and Over Current. Warning indicate, Excitation warning, Charger warning, Low Battery warning, Trip Lock warning Automatic or manual Start Stop, programmable with PC. Programming of parameters [threshold, time counts, etc] made easy by dip switch. 5 completely programmable fault available [times, polarity, possibility of stopping and massage about the fault]. Programmable weekly auto test

Type panel structure Protection Instrument Standard

Protection Device

Control System

Optional Equipment
Residential Silencer Digital Setting Unit Type CT Droop Kit Generator Heater Bearing Temperature RS 355 / 14 ND-SB1 [ 04410-31600 ] HC 7 HC7

Optional Equipment for Standby Rating


Lube Oil Priming Pump Motor Jacket Water Heater Water Heater Prelube Pump Auxiliary Control Panel 1.5 KW, 4 Pole, 220 400 V 2.0 KW, 3 Phase 220 480 V ; 1 Phase 110 480 V (stand by application) Remote control, automatic operation to Lube oil and jacket water heater

DGS/BMJ-ENG/2010