You are on page 1of 49

WATER RETICULATION

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

(ALL PROVISIONAL) SITE CLEARANCE Before commencing site clearance, the contractor shall ascertain the existence and position of water and other services from the relevant authorities and arrange for the diversion or termination of the services. The Contractor shall allow for paving all costs and charges in connection there with all as per engineer Drawing No. OPC 2012/07/P-01, P-02, P-03 A Allow for cut down and remove existing trees (palm oil) irrespective type and girth, grubbing uproots and cart away to an approved dumping ground to be found by the Contractor and permitted by the local authority. ITEM 275.00

Allow for taking over the site and clear the area and including encroachment area of all rubbish, debris, top soil, lalang, undergrowth,creepers, shrubs , bushes including mangroove of irrespective type and girth, grubbing uproots and cart away to an approved dumping ground to be found by the Contractor and was permitted by the local authority. (overall site development 16.041 acres)

Acre

16

3,000.00

P.B/1

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

(ALL PROVISIONAL) Specification and General Labour Clause For description of Materials, Workmanship and General Labour applicable to this Bill see "Preamble To All Trades". Note All excavation are measure from formation level unless otherwise stated EXCAVATION WORK Excavate pipe not exceeding 3.00m deep, get out, part return, fill in, well ram and remainder load and cart away from site, level, grade and ram bottom, trim sides and including planking and strutting and removed surplus material from site A 150mm diameter pipe and average 2000mm deep _____________________________ Backfill with selected excavated materials and compact in layers Mass Concrete Grade 15:C Thurst block for 150mm x 150mm x 150mm diameter tee overall size 562.5mm (average) x 450mm x 300mm high including all necessary excavation and sawn formwork. Ditto. for 150mm diameter pipe x 90 degree horizontal bend overall size 675mm x 337.5mm (average) x 600mm high do. Ditto. for 150mm diameter pipe x 45 degree horizontal bend overall size 675mm x 337.5mm (average) x 600mm high do. Do. for 150mm diameter pipe x 22/11 degree horizontal bend overall size 600mm x 162.5mm (average) x 600mm high do. Thurst block for 150mm diameter scour valve overall size 562.5mm x 450mm x 300mm high including all necessary excavation and sawn formwork. Ditto. for 150mm diameter duckfoot bend ditto. Do. for end cap do. M 3,023 8.00

M3

910

25.00

No

132.00

No

No

10

154.00

No

10

165.00

No

150.00

H J

No No

4 4

150.00 165.00

P.B/2

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

Quality control reinforced vibrated precast concrete Grade 20 including all moulds, hoisting and setting in position A Precast concrete standard indication post valve overall size 225mm x 150mm x 1787mm high, splayed at top edge, reinforced with and including 4 Nos.10mm diameter mild steel rods as main bars and 10Nos. 6mm diameter mild steel rod as links and stirrups and all lettering to be counter sunk 6mm below and including all necessary excavation and painting Precast concrete standard indication post hydrant overall size 225mm x 150mm x 1052mm high, ditto _____________________________ Precast concrete scour valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete sluice valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete air valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete hydrant chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03

No

16

132.00

No

550.00 No 4

550.00 No 7

No

No

P.B/3

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

MILD STEEL PIPE Mild steel pipes to BS 534 with internal cement lining and protected externally with reinforced asbestos felt or fibre glass felt jointed with cast iron "Gibault" joints and 150mm thk concrete surround as specified A B C D 150mm diameter pipe laid in trench (measured separately) Extra for 150mm x 150mm x 150mm tee Extra for 150mm diameter x 90 degree bend Extra for 150mm diameter x 45 degree bend UPVC PIPE Approved Unplasticised Polyvinyl Chloride (UPVC) pipes as described including jointing and fitting E F G 150mm diameter pipe laid in trench (measured separately) Extra for 150mm diameter x 45 degree bend Extra for 150mm dia. x 11 1/4 & 22 1/2 degree bend Cast iron fitting and specials to B.S 2035 and S.A.J's approval including extension pieces, all fixing accessories and jointing to mild steel pipes H 150mm diameter scour valve with single flanged and jointing to pipe (measured separately). 150mm diameter sluice valve with double flanged and jointing to pipe (measured separately). 150mm diameter air valve with double flanged and jointing to pipe (measured separately). 150mm diameter extension piece with double flanged jointing to sluice valve and duckfoot bend (both measured separately) and including all jointing accessories 150mm diameter end cap jointing to pipe M No No 2,761 6 10 M No No No 262 5 1 4 270.00 88.00 88.00 88.00

No

1,100.00

No

1,200.00

No

No No

4 4

P.B/4

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

Cast iron fitting and specials to B.S 2035 and S.A.J's approval including extension pieces, all fixing accessories and jointing to mild steel pipes A 150mm diameter fire hydrant to the S.O. and authorities approval and including jointing to extension pipe with and including painting one coat metallic primer two coats of gloss paint in signal yellow and 900mm x 900mm x 75mm thick Grade D concrete apron surround finished fair including all necessary Bulk Water Meter B Supply and fix bulk meter including sluice gate valves, t.pot strainer, flange adaptor, straightener double flanges, short piece single flanged, short plece, straighteners, bends, concrete pipe support, thrust block and all accessories and jointing to 150mm diameter pipe according to SAJ's approval Testing and Commissioning D Allow for sectional hydraulic testing of piping during laying and on completion all as described and make good any defects and leave the whole in prefect working order to the entire satisfaction of the S.O. Allow for sterilising commissioning and scouring of main pipes as described with all related works including liasion and coordination with SAJ and other relevant authorities Connection To Main Pipes F Labour and material to connect new pipes to existing pipes (hot tapping ) including all necessary pipes and fittings, machinery, permit and authority approval MAKING GOOD DISTURBED WORKS G Allow for making good works, repairs, joining to existing and reconstructed existing roadworks including excavation, crusher run, premis, road line and any other related works as per manufacturer's detail, S.O approval and satisfaction as shown in the Engineer's drawing

No

No

ITEM

ITEM

ITEM

ITEM

P.B/5

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

150MM DIAMETER PIPE JACKING A Mobisatilisation and demobilisation of equipment and personnel to site, including to apply all permit/ provide bank gurantee payable to relevent authorities, prepare for survey and setting out by licenced surveyor complete with underground utilities survey and mapping works. The Contractor shall submit for approval the shop drawing and method statement on pipe jacking and comply to local authority and SO approval. The Contractor are to provide temporary sign board, traffic contoller during construction including allowance for protection of existing underground utilities, water pipe, cable etc. To design, excavation, construct and maintain jacking pits including sheet piling, bracing, walling, concrete works, anchor foundation, guide rails etc for jacking the pipes To design, excavation, construct and maintain receiving pits including sheet piling, bracing, walling, concrete works, anchor foundation, guide rails etc for jacking the pipes To prepare, supply and install including labour and materials to fix and jack 150mm diameter RCP class Z sleeve to accommodate 150mm diameter mild steel pipe including provide all necessary water pumps, to dismantle and remove all temporary work and make good to the existing road and drain.

20

230.00

P.B/6

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE

(RM)

COLLECTION PAGE P.B/1 PAGE P.B/2 PAGE P.B/3 PAGE P.B/4 PAGE P.B/5 PAGE P.B/6 . . . . . . . . . . . . . . . . . .

WATER RECTICULATION TOTAL CARRIED TO FINAL SUMMARY P.B/S

Part B

AMOUNT (RM)

48,000.00

48,000.00 Part B

Water Reticulation

AMOUNT (RM)

24,184.00

22,750.00

660.00

1,540.00

1,650.00

1,050.00

600.00 660.00

53,094.00 Part B Water Reticulation

AMOUNT (RM)

2,112.00

2,200.00

3,850.00

6,050.00 Part B Water Reticulation

AMOUNT (RM)

70,740.00 440.00 88.00 352.00

4,400.00

8,400.00

84,420.00 Part B Water Reticulation

AMOUNT (RM)

Part B Water Reticulation

AMOUNT (RM)

4,600.00

4,600.00 Part B Water Reticulation

AMOUNT

(RM)

53,094.00 #REF! 6,050.00 84,420.00 #REF!

#REF!

WATER RETICULATION

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

(ALL PROVISIONAL) SITE CLEARANCE Before commencing site clearance, the contractor shall ascertain the existence and position of water and other services from the relevant authorities and arrange for the diversion or termination of the services. The Contractor shall allow for paving all costs and charges in connection there with all as per engineer Drawing No. OPC2012/07 SS-01 & SS-02

Allow for taking over the site and clear the area and including encroachment area of all rubbish, debris, top soil, lalang, undergrowth,creepers, shrubs , bushes including mangroove of irrespective type and girth, grubbing uproots and cart away to an approved dumping ground to be found by the Contractor and was permitted by the local authority.

ITEM

P.C/1

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

(ALL PROVISIONAL) Specification and General Labour Clause For description of Materials, Workmanship and General Labour applicable to this Bill see "Preamble To All Trades". Note All excavation are measure from formation level unless otherwise stated Jointing, nuts, brackets, straps, flanged ends, flanged adaptor, collars, inspections eye, bolts and nuts, short lengths, drops, offsets, mechanical coupling, plugs etc are not measured separately and rates are to include for these items. Rate shall also include for extra joints and extra fittings additional to those measured herein. EXCAVATION WORK Excavate pipe not exceeding 3.00m deep, get out, part return, fill in, well ram and remainder load and cart away from site, level, grade and ram bottom, trim sides and including planking and strutting and removed surplus material from site A 150mm diameter pipe and average 2000mm deep _____________________________ B Backfill with selected excavated materials and compact in layers Mass Concrete Grade 15:C Thurst block for 150mm x 150mm x 150mm diameter tee overall size 525mm x 300mm x 750mm high including all necessary excavation and sawn formwork. Ditto. for 150mm diameter pipe x 45 degree horizontal bend overall size 675mm x 337.5mm (average) x 600mm high do. Do. for 150mm diameter pipe x 22/11 degree horizontal bend overall size 600mm x 162.5mm (average) x 600mm high do. Ditto. for 150mm diameter duckfoot bend ditto. Do. for end cap do. P.C/2 M 1,725 8.00

M3

518

25.00

No

132.00

No

154.00

No No No

13 4 4 TO COLLECTION

165.00 150.00 165.00

F G

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

Quality control reinforced vibrated precast concrete Grade 20 including all moulds, hoisting and setting in position A Precast concrete standard indication post valve overall size 225mm x 150mm x 1787mm high, splayed at top edge, reinforced with and including 4 Nos.10mm diameter mild steel rods as main bars and 10Nos. 6mm diameter mild steel rod as links and stirrups and all lettering to be counter sunk 6mm below and including all necessary excavation and painting Precast concrete standard indication post hydrant overall size 225mm x 150mm x 1052mm high, ditto _____________________________ Precast concrete scour valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete sluice valve chamber internal size 840mm x 760mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete air valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete hydrant chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03

No

29

132.00

No

550.00 No 7

550.00 No 7

No

15

No

P.C/3

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

MILD STEEL PIPE Mild steel pipes to BS 534 with internal cement lining and protected externally with reinforced asbestos felt or fibre glass felt jointed with cast iron "Gibault" joints and 150mm thk concrete surround as specified A B C 150mm diameter pipe laid in trench (measured separately) Extra for 150mm x 150mm x 150mm tee Extra for 150mm diameter x 45 degree bend UPVC PIPE Approved Unplasticised Polyvinyl Chloride (UPVC) pipes as described including jointing and fitting D E F G 150mm diameter pipe laid in trench (measured separately) Extra for 150mm x 150mm x 150mm tee Extra for 150mm diameter x 45 degree bend Extra for 150mm dia. x 11 1/4 & 22 1/2 degree bend Cast iron fitting and specials to B.S 2035 and S.A.J's approval including extension pieces, all fixing accessories and jointing to mild steel pipes H 150mm diameter scour valve with single flanged and jointing to pipe (measured separately). 150mm diameter sluice valve with double flanged and jointing to pipe (measured separately). 150mm diameter air valve with double flanged and jointing to pipe (measured separately). 150mm diameter extension piece with double flanged jointing to sluice valve and duckfoot bend (both measured separately) and including all jointing accessories M No No No 1,576 4 2 13 M No No 149 1 4 270.00 88.00 88.00

No

1,100.00

No

1,200.00

No

15

No

P.C/4

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

Cast iron fitting and specials to B.S 2035 and S.A.J's approval including extension pieces, all fixing accessories and jointing to mild steel pipes A B C 150mm diameter duckfoot bend ditto. 150mm diameter end cap jointing to pipe 150mm diameter fire hydrant to the S.O. and authorities approval and including jointing to extension pipe with and including painting one coat metallic primer two coats of gloss paint in signal yellow and 900mm x 900mm x 75mm thick Grade D concrete apron surround finished fair including all necessary No No 4 4

No

Bulk Water Meter D Supply and fix bulk meter including sluice gate valves, t.pot strainer, flange adaptor, straightener double flanges, short piece single flanged, short plece, straighteners, bends, concrete pipe support, thrust block and all accessories and jointing to 150mm diameter pipe according to SAJ's approval Testing and Commissioning E Allow for sectional hydraulic testing of piping during laying and on completion all as described and make good any defects and leave the whole in prefect working order to the entire satisfaction of the S.O. Allow for sterilising commissioning and scouring of main pipes as described with all related works including liasion and coordination with SAJ and other relevant authorities Connection To Main Pipes G Labour and material to connect new pipes to existing pipes (hot tapping and normal) including all necessary pipes and fittings, machinery, permit and authority approval MAKING GOOD DISTURBED WORKS H Allow for making good works, repairs, joining to existing and reconstructed existing roadworks including excavation, crusher run, premis, road line and any other related works as per manufacturer's detail, S.O approval and satisfaction as shown in the Engineer's drawing

No

ITEM

ITEM

ITEM

ITEM

P.C/5

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

150MM DIAMETER PIPE JACKING A Mobisatilisation and demobilisation of equipment and personnel to site, including to apply all permit/ provide bank gurantee payable to relevent authorities, prepare for survey and setting out by licenced surveyor complete with underground utilities survey and mapping works. The Contractor shall submit for approval the shop drawing and method statement on pipe jacking and comply to local authority and SO approval. The Contractor are to provide temporary sign board, traffic contoller during construction including allowance for protection of existing underground utilities, water pipe, cable etc. To design, excavation, construct and maintain jacking pits including sheet piling, bracing, walling, concrete works, anchor foundation, guide rails etc for jacking the pipes To design, excavation, construct and maintain receiving pits including sheet piling, bracing, walling, concrete works, anchor foundation, guide rails etc for jacking the pipes To prepare, supply and install including labour and materials to fix and jack 150mm diameter RCP class Z sleeve to accommodate 150mm diameter mild steel pipe including provide all necessary water pumps, to dismantle and remove all temporary work and make good to the existing road and drain.

20

230.00

(END OF ALL PROVISIONAL)

P.C/6

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE

(RM)

COLLECTION PAGE P.C/1 PAGE P.C/2 PAGE P.C/3 PAGE P.C/4 PAGE P.C/5 PAGE P.C/6 . . . . . . . . . . . . . . . . . .

WATER RECTICULATION TOTAL CARRIED TO FINAL SUMMARY P.C/S

Part C

AMOUNT (RM)

Part C

Water Reticulation

AMOUNT (RM)

13,800.00

12,937.50

528.00

924.00

2,145.00 600.00 660.00 31,594.50 Part C Water Reticulation

AMOUNT (RM)

3,828.00

3,850.00

3,850.00

11,528.00 Part C Water Reticulation

AMOUNT (RM)

40,230.00 88.00 352.00

7,700.00

10,800.00

59,170.00 Part C Water Reticulation

AMOUNT (RM)

Part C Water Reticulation

AMOUNT (RM)

4,600.00 1,000.00

5,000.00

25,000.00

35,600.00 Part C Water Reticulation

AMOUNT

(RM)

31,594.50 #REF! 11,528.00 59,170.00 #REF!

#REF!

WATER RETICULATION

Part D

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

AMOUNT (RM)

(ALL PROVISIONAL) SITE CLEARANCE Before commencing site clearance, the contractor shall ascertain the existence and position of water and other services from the relevant authorities and arrange for the diversion or termination of the services. The Contractor shall allow for paving all costs and charges in connection there with all as per engineer Drawing No. OPC 2012/07/UR-01, UR-02 & UR-03

Allow for taking over the site and clear the area and including encroachment area of all rubbish, debris, top soil, lalang, undergrowth,creepers, shrubs , bushes including mangroove of irrespective type and girth, grubbing uproots and cart away to an approved dumping ground to be found by the Contractor and was permitted by the local authority.

ITEM

P.D/1

TO COLLECTION

Part D Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

AMOUNT (RM)

(ALL PROVISIONAL) Specification and General Labour Clause For description of Materials, Workmanship and General Labour applicable to this Bill see "Preamble To All Trades". Note All excavation are measure from formation level unless otherwise stated Jointing, nuts, brackets, straps, flanged ends, flanged adaptor, collars, inspections eye, bolts and nuts, short lengths, drops, offsets, mechanical coupling, plugs etc are not measured separately and rates are to include for these items. Rate shall also include for extra joints and extra fittings additional to those measured herein. EXCAVATION WORK Excavate pipe not exceeding 3.00m deep, get out, part return, fill in, well ram and remainder load and cart away from site, level, grade and ram bottom, trim sides and including planking and strutting and removed surplus material from site A 150mm diameter pipe and average 2000mm deep _____________________________ B Backfill with selected excavated materials and compact in layers Mass Concrete Grade 15:C Thurst block for 150mm x 150mm x 150mm diameter tee overall size 525mm x 300mm x 750mm high including all necessary excavation and sawn formwork. Ditto. for 150mm diameter pipe x 45 degree horizontal bend overall size 675mm x 337.5mm (average) x 600mm high do. Do. for 150mm diameter pipe x 90 degree horizontal bend overall size 600mm x 375mm (average) x 450mm high do. Do. for 150mm diameter pipe x 22/11 degree horizontal bend overall size 600mm x 162.5mm (average) x 600mm high do. M 2,537 8.00 20,296.00

M3

761

25.00

19,027.50

No

26

132.00

3,432.00

No

154.00

154.00

No

165.00

330.00

No

16

P.D/2

TO COLLECTION

43,239.50

Part D Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

AMOUNT (RM)

Quality control reinforced vibrated precast concrete Grade 20 including all moulds, hoisting and setting in position A Precast concrete standard indication post valve overall size 225mm x 150mm x 1050mm high, splayed at top edge, reinforced with and including 4 Nos.10mm diameter mild steel rods as main bars and 10Nos. 6mm diameter mild steel rod as links and stirrups and all lettering to be counter sunk 6mm below and including all necessary excavation and painting Precast concrete standard indication post hydrant overall size 225mm x 150mm x 1052mm high, ditto _____________________________ Precast concrete scour valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07- WR 01, 02, 03 Precast concrete sluice valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07- WR 01, 02, 03 Precast concrete air valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07- WR 01, 02, 03

No

33

50.00

1,650.00

No

550.00 No 4

550.00 No 12

No

17

Precast concrete hydrant chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07- WR 01, 02, 03

No

P.D/3

TO COLLECTION

1,650.00 Part D

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

AMOUNT (RM)

MILD STEEL PIPE Mild steel pipes to BS 534 with internal cement lining and protected externally with reinforced asbestos felt or fibre glass felt jointed with cast iron "Gibault" joints and 150mm thk concrete surround as specified A B C D E 150mm diameter pipe laid in trench (measured separately) Extra for 150mm x 150mm x 150mm tee Extra for 150mm diameter x 45 degree bend Extra for 150mm dia. x 11 1/4 & 22 1/2 degree bend Extra for petronas gas reserve pipe crossing complete with R.C Piers UPVC PIPE Approved Unplasticised Polyvinyl Chloride (UPVC) pipes as described including jointing and fitting F G H J K 150mm diameter pipe laid in trench (measured separately) Extra for 150mm x 150mm x 150mm tee Extra for 150mm diameter x 90 degree bend Extra for 150mm diameter x 45 degree bend Extra for 150mm dia. x 11 1/4 & 22 1/2 degree bend Cast iron fitting and specials to B.S 2035 and S.A.J's approval including extension pieces, all fixing accessories and jointing to mild steel pipes L 150mm diameter scour valve with single flanged and jointing to pipe (measured separately). 150mm diameter sluice valve with double flanged and jointing to pipe (measured separately). 150mm diameter air valve with double flanged and jointing to pipe (measured separately). 150mm diameter extension piece with double flanged jointing to sluice valve and duckfoot bend (both measured separately) and including all jointing accessories 150mm diameter duckfoot bend (do) do. 150mm diameter end cap jointing to pipe M No No No No 2,361 22 2 1 12 245.00 250.00 250.00 250.00 578,445.00 5,500.00 500.00 250.00 M No No No 176 4 2 4 220.00 220.00 38,720.00 880.00

No

1,100.00

4,400.00

No

12

1,200.00

14,400.00

No

19

No No No

6 6 6

Q R

P.D/4

TO COLLECTION

643,095.00 Part D

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

AMOUNT (RM)

Cast iron fitting and specials to B.S 2035 and S.A.J's approval including extension pieces, all fixing accessories and jointing to mild steel pipes (cont'd) A 150mm diameter fire hydrant to the S.O. and authorities approval and including jointing to extension pipe with and including painting one coat metallic primer two coats of gloss paint in signal yellow and 900mm x 900mm x 75mm thick Grade D concrete apron surround finished fair including all necessary Bulk Water Meter C Supply and fix fire hydrant bulk meter including sluice gate valves, t.pot strainer, flange adaptor, straightener double flanges, straighteners, bends, concrete pipe support, thrust block and all accessories and jointing to 150mm diameter pipe according to SAJ's approval Testing and Commissioning D Allow for sectional hydraulic testing of piping during laying and on completion all as described and make good any defects and leave the whole in prefect working order to the entire satisfaction of the S.O. Allow for sterilising commissioning and scouring of main pipes as described with all related works. including liasion and coordination with SAJ and other relevant authorities Connection To Main Pipes G Labour and material to connect new pipes to existing pipes (hot tapping and normal) including all necessary pipes and fittings, machinery, permit and authority approval

No

No

ITEM

20,000.00

E F

20,000.00 ITEM

ITEM

Making Good Disturbed Works


H

Allow for making good works, repairs, joining to existing and reconstructed existing roadworks including excavation, crusher run, premis, road line and any other related works as per manufacturer's detail, S.O approval and satisfaction as shown in the Engineer's drawing

ITEM

P.D/5

TO COLLECTION

40,000.00 Part D

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

AMOUNT (RM)

WATER RETICULATION OUTSIDE BOUNDARY (cont'd) 150mm Diameter Pipe Jacking A Mobisatilisation and demobilisation of equipment and personnel to site, including to apply all permit/ provide bank gurantee payable to relevent authorities, prepare for survey and setting out by licenced surveyor complete with underground utilities survey and mapping works. The Contractor shall submit for approval the shop drawing and method statement on pipe jacking and comply to local authority and SO approval. The Contractor are to provide temporary sign board, traffic contoller during construction including allowance for protection of existing underground utilities, water pipe, cable etc. To design, excavation, construct and maintain jacking pits including sheet piling, bracing, walling, concrete works, anchor foundation, guide rails etc for jacking the pipes To design, excavation, construct and maintain receiving pits including sheet piling, bracing, walling, concrete works, anchor foundation, guide rails etc for jacking the pipes To prepare, supply and install including labour and materials to fix and jack 150mm diameter RCP class Z sleeve to accommodate 150mm diameter mild steel pipe including provide all necessary water pumps, to dismantle and remove all temporary work and make good to the existing road and drain.

10.00

25.00

20

(END OF ALL PROVISIONAL)

P.D/6

TO COLLECTION

Part D Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

AMOUNT (RM)

COLLECTION PAGE P.D/1 PAGE P.D/2 PAGE P.D/3 PAGE P.D/4 PAGE P.D/5 PAGE P.D/6 . . . . . . . . . . . . . . . . . . #REF! 43,239.50 12,634.00 643,095.00 40,000.00 -

WATER RECTICULATION TOTAL CARRIED TO FINAL SUMMARY P.D/S

#REF!

WATER RETICULATION

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

(ALL PROVISIONAL) SITE CLEARANCE Before commencing site clearance, the contractor shall ascertain the existence and position of water and other services from the relevant authorities and arrange for the diversion or termination of the services. The Contractor shall allow for paving all costs and charges in connection there with all as per engineer Drawing No. OPC2012/07 SM - 01

Allow for taking over the site and clear the area and including encroachment area of all rubbish, debris, top soil, lalang, undergrowth,creepers, shrubs , bushes including mangroove of irrespective type and girth, grubbing uproots and cart away to an approved dumping ground to be found by the Contractor and was permitted by the local authority.

ITEM

P.E/1

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

(ALL PROVISIONAL) Specification and General Labour Clause For description of Materials, Workmanship and General Labour applicable to this Bill see "Preamble To All Trades". Note All excavation are measure from formation level unless otherwise stated Jointing, nuts, brackets, straps, flanged ends, flanged adaptor, collars, inspections eye, bolts and nuts, short lengths, drops, offsets, mechanical coupling, plugs etc are not measured separately and rates are to include for these items. Rate shall also include for extra joints and extra fittings additional to those measured herein. EXCAVATION WORK Excavate pipe not exceeding 3.00m deep, get out, part return, fill in, well ram and remainder load and cart away from site, level, grade and ram bottom, trim sides and including planking and strutting and removed surplus material from site A 150mm diameter pipe and average 2000mm deep _____________________________ B Backfill with selected excavated materials and compact in layers Mass Concrete Grade 15:C Thurst block for 150mm x 150mm x 150mm diameter tee overall size 525mm x 300mm x 750mm high including all necessary excavation and sawn formwork. Ditto. for 150mm diameter pipe x 45 degree horizontal bend overall size 675mm x 337.5mm (average) x 600mm high do. Do. for 150mm diameter pipe x 22/11 degree horizontal bend overall size 600mm x 162.5mm (average) x 600mm high do. Ditto. for 150mm diameter duckfoot bend ditto. Do. for end cap do. P.E/2 M 1,213 8.00

M3

364

25.00

No

132.00

No

154.00

No No No

15 2 2 TO COLLECTION

165.00 150.00 165.00

F G

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

Quality control reinforced vibrated precast concrete Grade 20 including all moulds, hoisting and setting in position A Precast concrete standard indication post valve overall size 225mm x 150mm x 1787mm high, splayed at top edge, reinforced with and including 4 Nos.10mm diameter mild steel rods as main bars and 10Nos. 6mm diameter mild steel rod as links and stirrups and all lettering to be counter sunk 6mm below and including all necessary excavation and painting Precast concrete standard indication post hydrant overall size 225mm x 150mm x 1052mm high, ditto _____________________________ C Precast concrete scour valve chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete sluice valve chamber internal size 840mm x 760mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete air valve chamber internal size 605mm x 530mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03 Precast concrete hydrant chamber internal size 1200mm x 1200mm x 2000mm deep in 2 nos top section complete with approved moulds and mild steel rod reinforcement, compacted sand fill and precast concrete slab, step iron, 10mm thick galvanised mild steel chequer plate cover and all including all necessary excavation and painting as painting as per Engineer's drawing no.OPC 2012/07WR 01, 02, 03

No

18

132.00

No

550.00 No 2

550.00 No 7

No

No

P.E/3

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

MILD STEEL PIPE Mild steel pipes to BS 534 with internal cement lining and protected externally with reinforced asbestos felt or fibre glass felt jointed with cast iron "Gibault" joints and 150mm thk concrete surround as specified A B C 150mm diameter pipe laid in trench (measured separately) Extra for 150mm x 150mm x 150mm tee Extra for 150mm dia. x 11 1/4 & 22 1/2 degree bend UPVC PIPE Approved Unplasticised Polyvinyl Chloride (UPVC) pipes as described including jointing and fitting D E F G 150mm diameter pipe laid in trench (measured separately) Extra for 150mm x 150mm x 150mm tee Extra for 150mm diameter x 45 degree bend Extra for 150mm dia. x 11 1/4 & 22 1/2 degree bend Cast iron fitting and specials to B.S 2035 and S.A.J's approval including extension pieces, all fixing accessories and jointing to mild steel pipes H 150mm diameter scour valve with single flanged and jointing to pipe (measured separately). 150mm diameter sluice valve with double flanged and jointing to pipe (measured separately). 150mm diameter air valve with double flanged and jointing to pipe (measured separately). 150mm diameter extension piece with double flanged jointing to sluice valve and duckfoot bend (both measured separately) and including all jointing accessories M No No No 1,159 2 2 14 M No No 54 1 1 270.00 88.00

No

1,100.00

No

1,200.00

No

No

P.E/4

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

Cast iron fitting and specials to B.S 2035 and S.A.J's approval including extension pieces, all fixing accessories and jointing to mild steel pipes A B C 150mm diameter duckfoot bend ditto. 150mm diameter end cap jointing to pipe 150mm diameter fire hydrant to the S.O. and authorities approval and including jointing to extension pipe with and including painting one coat metallic primer two coats of gloss paint in signal yellow and 900mm x 900mm x 75mm thick Grade D concrete apron surround finished fair including all necessary No No 2 2

No

Bulk Water Meter D Supply and fix bulk meter including sluice gate valves, t.pot strainer, flange adaptor, straightener double flanges, short piece single flanged, short plece, straighteners, bends, concrete pipe support, thrust block and all accessories and jointing to 150mm diameter pipe according to SAJ's approval Testing and Commissioning E Allow for sectional hydraulic testing of piping during laying and on completion all as described and make good any defects and leave the whole in prefect working order to the entire satisfaction of the S.O. Allow for sterilising commissioning and scouring of main pipes as described with all related works including liasion and coordination with SAJ and other relevant authorities Connection To Main Pipes G Labour and material to connect new pipes to existing pipes (hot tapping and normal) including all necessary pipes and fittings, machinery, permit and authority approval MAKING GOOD DISTURBED WORKS H Allow for making good works, repairs, joining to existing and reconstructed existing roadworks including excavation, crusher run, premis, road line and any other related works as per manufacturer's detail, S.O approval and satisfaction as shown in the Engineer's drawing

No

ITEM

ITEM

ITEM

ITEM

P.E/5

TO COLLECTION

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE (RM)

150MM DIAMETER PIPE JACKING A Mobisatilisation and demobilisation of equipment and personnel to site, including to apply all permit/ provide bank gurantee payable to relevent authorities, prepare for survey and setting out by licenced surveyor complete with underground utilities survey and mapping works. The Contractor shall submit for approval the shop drawing and method statement on pipe jacking and comply to local authority and SO approval. The Contractor are to provide temporary sign board, traffic contoller during construction including allowance for protection of existing underground utilities, water pipe, cable etc. To design, excavation, construct and maintain jacking pits including sheet piling, bracing, walling, concrete works, anchor foundation, guide rails etc for jacking the pipes To design, excavation, construct and maintain receiving pits including sheet piling, bracing, walling, concrete works, anchor foundation, guide rails etc for jacking the pipes To prepare, supply and install including labour and materials to fix and jack 150mm diameter RCP class Z sleeve to accommodate 150mm diameter mild steel pipe including provide all necessary water pumps, to dismantle and remove all temporary work and make good to the existing road and drain.

20

230.00

(END OF ALL PROVISIONAL)

P.E/6

Water Reticulation

ITEM

DESCRIPTION

UNIT

QUANTITY

RATE

(RM)

COLLECTION PAGE P.E/1 PAGE P.E/2 PAGE P.E/3 PAGE P.E/4 PAGE P.E/5 PAGE P.E/6 . . . . . . . . . . . . . . . . . .

WATER RECTICULATION TOTAL CARRIED TO FINAL SUMMARY P.D/S

Part E

AMOUNT (RM)

Part E

Water Reticulation

AMOUNT (RM)

9,704.00

9,097.50

396.00

308.00

2,475.00 300.00 330.00 22,610.50 Part E Water Reticulation

AMOUNT (RM)

2,376.00

2,376.00 Part E Water Reticulation

AMOUNT (RM)

14,580.00 88.00

2,200.00

8,400.00

25,268.00 Part E Water Reticulation

AMOUNT (RM)

Part E Water Reticulation

AMOUNT (RM)

4,600.00 1,000.00

5,000.00

25,000.00

35,600.00 Part E Water Reticulation

AMOUNT

(RM)

22,610.50 #REF! 2,376.00 25,268.00 #REF!

#REF!

You might also like