High Performance Air-Conditioning

Inverter Packaged Air-Conditioners

FD series

50/60Hz
10P01E-A-0

Our new advanced technology has realized high efficiency, strong heating and long piping. This contributes to the environmental protection through energy saving and permits installation of the units (4~6HP) considering a heating operation under temperature conditions down to -20C and design flexibility has been improved by extension of piping length to 100m.

NEW

1.5~2.5HP

3HP
Line up
1.5 Hyper Inverter

4~6HP
HP

2.5

10

High efficiency
, The industry s highest COP levels are achieved by our latest technologies, such as new high efficient twin rotary compressors and the combination with new Hyper inverter outdoor units.

EER in cooling

COP in heating

3.62

4.09 3.09 2.81

3.71

3.50

Micro Hyper

Micro Hyper

Micro Hyper

Micro Hyper

Micro Hyper

Micro Hyper

4HP

5HP

6HP

4HP

5HP

6HP

(comparison of FDT series) 2

Long piping
(in case of 4~6HP)

Strong heating
(in case of 4~6HP)

-20C : Heating operation down to -20C -15C : Nominal heating capacity maintained at -15C
Height difference Piping length
(Outdoor higher than Indoor)
-20C

Heating

+20C

30m

-15C

Cooling

+43C

50

100m

-30

-20

-10

10

20

30

40

50

Max.heating capacity (kW)


Hyper Inverter Micro Inverter FDC100VSX(4HP, 3phase 380V) FDC125VSX(5HP, 3phase 380V) FDC140VSX(6HP, 3phase 380V) 12.5 16.0 16.5

Leading powerful heating capacity in the industry


Thanks to optimization of refrigeration control with use of electric expansion valve and development of new twin rotary compressors, max heating capacity has been increased. Hyper Inverter series can reach the set temperature very quickly, keeping nominal heating capacity when outdoor temperature is -15C. It is effective to be used even in cold area. Temperature of supply air can reach 40C in 4 minutes after start up under low temperature operation conditions (at both indoor and outdoor temperature of 2C) and can reach 50C in 8 minutes after that.

(kW)

Heating capacity (in case of 5HP)


Keeping nominal heating capacity at -15C

Heating capacity
50C
nominal heating capacity 14.0kW

18.0 14.5 14.0

Hyper Inverter

Hyper Inverter

40C 30C 20C

8.8 0

Micro Inverter
-15C
nominal heating capacity
(kW at outdoor temperature of 7C)

2C

7C

Micro Inverter
model name FDT100VSX(4HP, 3phase 380V) FDT125VSX(5HP, 3phase 380V) FDT140VSX(6HP, 3phase 380V)
heating capacity at outdoor temperature of -15C

10C 0C 4minutes 8minutes

11.2kW 14.0kW 16.0kW

11.2kW 14.0kW 16.0kW

Please refer to our technical manual for installation conditions, operation range and heating/cooling capacities.

Micro Inverter
Compact Design of outdoor units
Line up
1.5 Micro Inverter 2 2.5 3 4 5 6 8
HP

10
Height

Height

390mm
Height

185mm

455mm
Width

Width

380mm

380mm
Depth

FDC100VN/VS (4.0HP) FDC125VN/VS (5.0HP) FDC140VN/VS (6.0HP)


Easy installation
Former model New model

350mm

Depth

350mm

FDC200VS (8.0HP)
Fits into elevators

FDC250VS (10.0HP)

4.0HP 5.0HP 6.0HP 8.0HP 10.0HP

82 118 125 225 225

74 74 74 122 140

*Reduction
-8 -44 -51 -103 -85

4.0HP 5.0HP 6.0HP 8.0HP 10.0HP

Former model New model *Reduction

328 467 467 1643 1643

303 303 303 467 540

8% 35% 35% 72% 67%

* Comparison with former models

* Comparison with former models

Size reduction and high efficiency performance on the DC twin rotary compressors
(Micro Inverter 4-6HP)

Improved efficiency of heat exchanger


Redesigning the fins to a straight shape has reduced the pressure loss of the airflow in the heat exchanger. Surface treatment on the fin has enhanced the frost resistance capacity compared with former models. Owing to the reduction in the size of heat exchanger, the appropriate number of circuits for each HP has been applied. Employment of a high-speed motor has increased the airflow and enabled to keep the cooling capacity under a condition of higher outdoor air temperatures*.
* Limitation of use is around 43: at the maximum.

Employment of DC twin rotary compressor has enabled to utilize a high-speed range of up to 120 rps at the maximum to secure the required capacity. Optimum compressor control has been realized by employing the vector control* and the starting current has been improved significantly compared with former models. Moreover, vibration has been reduced.
Reduction in height by 22.3% Reduction in volume by 44.1%
* Vector control means a. technique to realize an optimum control by converting the current wave to a smooth sinusoidal waveform

Height at 440 mm

Height at 342mm

Outside diameter of shell 185mm

133mm

Former model

New model

Controllability
Reliability in the protection of compressor has been improved by optimizing the controls of oil return, electronic expansion valve, etc.

Former compressor

New model DC rotary compressor

High technology
POINT

DC fan motor uses less energy

POINT

Optimization of heat exchanger path. More efficient heating and cooling

2 3

POINT

Super heat control with low pressure sensor, works better in tough conditions

4 5
FDC200VS
(8.0HP)
970 mm

POINT

High efficiency refrigeration circuit

m 370

POINT

Newly developed High efficiency DC scroll compressor

Employment of the scroll inverter compressors(8/10HP)


A control over wide range of capacity and a high efficiency has been realized by inverter-driven scroll compressors. In addition, the starting current significantly is improved. The size has also been reduced by 3.2% in height and 31.8% in volume.

Energy labeling Class A


MHI models have cleared the class A standard, the highest energy saving level, with their high COP (coefficient of performance).

CLASS

Employment of DC fan motor


Employment of DC fan motor has enabled to realize an excellent efficiency of approx. 60% higher than former models.

A
B C D E F G

Energy

Air-conditioner

Manufacturer Outside unit Inside unit More efficient

Wide range of operation


Our new advanced technology has expanded the heating and cooling operation range. This permits installation of the units under a low outdoor temperature conditions down to -20C In heating operation and -15C in cooling operation.
(FDC 100/125/140)
-20C -15C

A B C D E F G
Less efficient
Annual energy consumption, kWh in cooling mode
(Actual consumption will depend on how the appliance is used and climate)

Cooling output nergy fficiency atio


Full load (the higher the better)

kW

Type

Cooling only Cooling + Heating Air cooled Water cooled

Heat output

kW
G: lower

Heating Cooling
-10 0 10 20

A: higher

Heating performance

+20C +43C

Noise
(dB(A) re 1 pW)

Further information is contained in product brochures


Air-conditioner Energy Label Directive 2002/31/EC

-30

-20

30

40

50

Ceiling Cassette -4way- Indoor units

FDT.FDTC

Individual flap control system


According to room temperature conditions, four directions of air flow can be controlled by individual flap as preferred. As individual flap control is available even after installation, installation area became wider than before. Due to optimization of outlet design of air flow with our new advanced technology, sufficient air flow is secured and long reach of air flow is realized.(FDT)

Previous

New

Flap control system


Selection of louver position is possible. Louvers can be set at different angles.
is the Individual flap control *RCH-E3andnot applicable tosystem. system the Flap control
Upper position Movable range Lower position

For person who is far from the indoor unit

The thinnest design


Thanks to new design of heat exchanger changed from 2 parts to 1 part, the height of indoor unit is reduced drastically. Furthermore applying DC fan motors, the highest energy efficiency level, reduction of weight and significant compact design are realized.

FDT125~140

365mm

298
mm
FDT40~71
270mm

reduction!!

18%

For both persons who are feeling hot or cold

Shape of heat exchanger

Previous

New

246
mm

reduction!!

9%

Can cool both the kitchen and the guests

High efficiency
Reduction of air flow pressure loss
Expansion of outlet air flow area realizes reduction of pressure loss caused by air flow in the indoor unit. Load of fan motor is decreased and efficiency is increased.

Increase of heat transfer efficiency


Applying high efficient piping in heat exchanger and optimization of heat exchanger (2parts 1part) increases heat transfer efficiency.

Achieved COP 5.67


based on 50% capacity of FDT100V in heating operation Air-conditioners are generally selected with the operation under the most severe ambient temperature conditions. The inverter constantly adjusts compressor output to meet the exact demand of the indoor units. i.e. In case that selecting the capacity of an inverter air-conditioner based on heating operation at -5C, its capacity drops by 50% at 7C(ISO-TI measurement condition) and operation period at 50% capacity is normally longer than that at 100% of nominal heating capacity. Considering annual electrical power consumption of inverter air-conditioners, it is quite important to give the first priority to 50% actual capacity and selecting inverter air-conditioners is the best solution for saving energy and protecting the environment.

Convenience
Signal output
A dry contact is equipped on an indoor unit to meet a possible need for signal output on the site.
CnT
XR2 XR3 XR4 XR5 XR5 XR1~5 : approx. DC12v Power source XR1 XR1 XR2 XR3 XR4 common output1 (run) output2 (heat) output3 (comp on) output4 (alarm) in put

Monitoring Function
Equipped with RS232C for connection directly to your PC monitoring and service tasks made simple with our service software (Mente PC).

New remote control


Applying nonpolar 2-core in new remote control line for all indoor units, it is very convenient for installation including renewal case.
Previous New

-core

-core

Consideration on the Environment

Employment of lead-free solder


Adapt to RoHS
In order to comply with RoHS standard, the new inverter series products use lead-free solder. It was considered to be too difficult to use lead-free solder because it requires higher soldering temperatures at assembling, which could jeopardize the reliability of assembly, etc. PbF soldering method developed by us, however, has enabled a higher reliability for lead-free printed circuit boards.
*"RoHS" is the abbreviation of the new European standard, which means Restriction of Hazardous Substances.

Employment of the new refrigerant


All models of the New inverter series use a new refrigerant R410A characterized by the ozone depletion coefficient being 0.

Energy Conservation
A High Performance and Excellent Energy Conservation are achieved at the same time by an increased capacity of heat exchanger and employment of high efficiency DC motor etc.

SINGLE [OUTDOOR UNIT : INDOOR UNIT = 1 : 1]


HP kW Btu/h kcal/h
1.5 4.0 13,700 3,440 2.0 5.0 17,100 4,300 2.5 6.0 19,100 4,816 3.0 7.1 23,900 6,020 4.0 10.0 34,100 8,600

Indoor unit
FDT40VD FDT50VD FDT60VD FDT71VD FDT100VD

Outdoor unit 1phase 3phase 1phase Set 3phase Indoor unit


FDTC40VD FDTC50VD FDTC60VD SRC40ZIX-S SRC50ZIX-S SRC60ZIX-S FDC71VNX FDC100VNX FDC100VSX

Outdoor unit 1phase Set 1phase Indoor unit


FDU71VD FDU100VD SRC40ZIX-S SRC50ZIX-S SRC60ZIX-S

Outdoor unit 1phase 3phase 1phase Set 3phase Indoor unit


FDUM50VD FDUM60VD FDUM71VD FDUM100VD FDC71VNX FDC100VNX FDC100VSX

* *

Outdoor unit 1phase 3phase 1phase Set 3phase Indoor unit


FDEN40VD FDEN50VD FDEN60VD FDEN71VD FDEN100VD SRC50ZIX-S SRC60ZIX-S FDC71VNX FDC100VNX FDC100VSX

Outdoor unit 1phase 3phase 1phase Set 3phase


SRC40ZIX-S SRC50ZIX-S SRC60ZIX-S FDC71VNX FDC100VNX FDC100VSX

Micro Inverter
5.0 12.5 42,700 10,750 6.0 14.0 47,800 12,040 4.0 10.0 34,100 8,600 5.0 12.5 42,700 10,750 6.0 14.0 47,800 12,040 8.0 20.0 68,300 17,200 10.0 25.0 85,400 21,500

FDT125VD
NEW

FDT140VD

FDT100VD

FDT125VD

FDT140VD

FDC125VNX FDC125VSX

FDC140VNX FDC140VSX

FDC100VN FDC100VS

FDC125VN FDC125VS

FDC140VN FDC140VS

FDU125VD
NEW

FDU140VD

FDU100VD

FDU125VD

FDU140VD

FDU200VD

FDU250VD

FDC125VNX FDC125VSX

FDC140VNX FDC140VSX

FDC100VN FDC100VS

FDC125VN FDC125VS

FDC140VN FDC140VS

FDC200VS

FDC250VS

* *

* *

* *

* *

* *

FDUM125VD
NEW

FDUM140VD

FDUM100VD

FDUM125VD

FDUM140VD

FDC125VNX FDC125VSX

FDC140VNX FDC140VSX

FDC100VN FDC100VS

FDC125VN FDC125VS

FDC140VN FDC140VS

FDEN125VD
NEW

FDEN140VD

FDEN100VD

FDEN125VD

FDEN140VD

FDC125VNX FDC125VSX

FDC140VNX FDC140VSX

FDC100VN FDC100VS

FDC125VN FDC125VS

FDC140VN FDC140VS

*Not available in 60Hz

[ INDOOR UNIT ]
CEILING CASSETTE -4way-

FDT
Point

CLASS

Wired remote control

Wireless remote control

FDT 40/50/60/71/ 100/125/140VD

RC-E4
(Option)

RCH-E3
(Option)

RCN-T-36W-E
(Option)

1 Arrangement of installation balance of indoor unit

Point

2 Installation Workability

Checking from access ports with detachable covers at each corner, arrangement of installation balance of indoor unit can be available without removing a panel. Workability is improved and time of installation is reduced. Point

For wireless control simply insert the infrared receiver kit on a corner of the panel

wireless remote control RCN-T-36W-E

3 Easy checking of drain pan

Point

4 700mm Drain Pump


Flexible hose

Easy checking of drain pan condition is available by removing corner lid only. Due to new design changing fan motor is available without removing a panel. Temporally setting of drain pan is also available.

Drain can be discharged upwards by 700mm from the ceiling surface. It allows a piping layout with a high degree of freedom Depending on the installation location and 260mm flexible hose as a standard equipment supports easy workability.

less than 700mm

Outline drawing (Unit:mm)


Model FDT40,50,60,71VD Model 100,125,140VD

10

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity kW ISO-T1(JIS) (Min~Max) Nominal heating capacity kW ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating kW COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) A Indoor Sound Ievel*1 dB(A) Outdoor Indoor Air flow CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Unit+Panel Net weight Panel Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m O/U is lower difference Cooling O/U Operating temperature range Heating O/U 4.0 (1.8~4.7) 4.5 (2.0~5.4) 0.93/1.15 4.30/3.91 A/A 5(12) FDT40ZIXVD FDT40VD SRC40ZIX-S FDT50ZIXVD FDT50VD SRC50ZIX-S FDT60ZIXVD FDT60VD SRC60ZIX-S

FDT71VNXVD FDT71VD FDC71VNX

FDT100VNXVD FDT100VD FDC100VNX

1Phase 220-240V 50Hz, 1Phase 220V 60Hz 5.0 (2.2~5.6) 5.4 (2.5~6.3) 1.29/1.29 3.88/4.19 A/A 5(14) 5.6 (2.8~6.3) 6.7 (3.1~7.1) 1.57/1.85 3.57/3.62 A/A

Hi:33 Me:31 Lo:30 47 Hi:18 Me:16 Lo:14


48 Hi:18 Me:16 Lo:14

40 Unit:246x840x840 Panel:35x950x950 27.5(Unit:22 Panel:5.5) 29.5(Unit:24 Panel:5.5) T-PSA-3AW-E Pocket Plastic net x1 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-T-36W-E 640x800(+71)x290 1,300x970x370 750x880(+88)x340 43 105 60 Scroll Rotary 1.4(15) 4.5(30) 2.95(30) 6.35/12.7 9.52/15.88 30 100 50 20 30 30 20 15 15 -15~43*2 -20~20 -15~20

7.1 (3.2~8.0) 8.0 (3.6~9.0) 1.90/2.07 3.74/3.86 A/A 5(17) Hi:35 Me:33 Lo:31 Cooling:51 Heating:48 Hi:21 Me:19 Lo:17 Cooling:60 Heating:50

Range of Outdoor unit usage

Indoor unit

10.0 (4.0~11.2) 11.2 (4.0~12.5) 2.50/2.58 4.00/4.34 A/A 5(24) Hi:40 Me:37 Lo:35 Cooling:48 Heating:50 Hi:27 Me:24 Lo:20 100 Unit:298x840x840 Panel:35x950x950 32.5(Unit:27 Panel:5.5)

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity kW ISO-T1(JIS) (Min~Max) Nominal heating capacity kW ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating kW COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) A Indoor Sound Ievel*1 dB(A) Outdoor Indoor Air flow CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Unit+Panel Net weight Panel Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m O/U is lower difference Cooling O/U Operating temperature range Heating O/U FDT125VNXVD FDT125VD FDC125VNX FDT140VNXVD FDT140VD FDC140VNX FDT100VSXVD FDT100VD FDC100VSX FDT125VSXVD FDT125VD FDC125VSX FDT140VSXVD FDT140VD FDC140VSX

1Phase 220-240V 50Hz, 1Phase 220V 60Hz 12.5 (5.0~14.0) 14.0 (4.0~17.0) 3.28/3.43 3.81/4.08 A/A 14.0 (5.0~16.0) 16.0 (4.0~18.0) 4.19/4.20 3.34/3.81 A/A

3Phase 380-415V 50Hz, 3Phase 380V 60Hz 10.0 (4.0~11.2) 11.2 (4.0~16.0) 2.50/2.58 4.00/4.34 A/A

14.0 12.5 (5.0~16.0) (5.0~14.0) 16.0 14.0 (4.0~20.0) (4.0~18.0) 4.19/4.20 3.28/3.43 3.34/3.81 3.81/4.08 A/A A/A 5(26) 5(15) Hi:42 Me:40 Lo:37 Hi:43 Me:41 Lo:38 Hi:40 Me:37 Lo:35 Hi:42 Me:40 Lo:37 Hi:43 Me:41 Lo:38 Cooling:48 Heating:50 Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling:49 Heating:52 Hi:30 Me:27 Lo:23 Hi:27 Me:24 Lo:20 Hi:30 Me:27 Lo:23 100 Unit:298x840x840 Panel:35x950x950 32.5(Unit:27 Panel:5.5) T-PSA-3AW-E Pocket Plastic net x1 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-T-36W-E 1,300x970x370 105 Rotary 4.5(30) 9.52/15.88 100 30 15 -15~43*2 -20~20

Range of Outdoor unit usage

Indoor unit

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *2 :: If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 40/50ZIXVD 39dB, 60ZIXVD 46dB, 71VNXVD 46dB, 100/125/140VNXVD 51dB, 100/125/140VSXVD 51dB Air flow: 40/50ZIXVD 20CMM, 60ZIXVD 28CMM, 71VNXVD 28CMM, 100/125/140VNXVD 37CMM, 100/125/140VSXVD 37CMM

11

[ INDOOR UNIT ]
CEILING CASSETTE -4way Compact (600 X 600mm)-

FDTC

CLASS
Fits into standard 600 x 600 ceiling

FDTC 40/50/60VD
Wired remote control Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-TC-24W-ER
(Option)

Point

1 Quiet operation
35dB

Point

(Sound level in the Lo mode)

2 CLEARERAir Flow

(dB)

36 35 34 33 32 31 30 29 28 27 26 25

3dB Down

32dB 30dB
5dB Down
Point

New shape & angled louver redirects the air current away from the ceiling, to reduce ceiling stains

3 Installation Workability
For wireless control simply insert the infrared receiver kit on a corner of the panel wireless remote control RCN-TC-24W-ER

Previous (Cooling/Heating)

New (Cooling)

New (Heating)

FDTC40/50/60VD

Point

4 Compact Concept

Point

5 Comfortable and Convenient


600mm Drain Pump is mounted.
Drain can be discharged upward by 600 mm from the ceiling surface close to the indoor unit. It allows a piping layout with a high degree of freedom depending on the installation location.
Flexible hose 600mm

The industry's lowest level 248mm height.


Panel size (700x700) is suitable for 600x600 ceiling panel. All indoor unit size is (WxD: 570x570). It brings easy installation for 600x600 ceiling panel.

All units are 18.5kg, light


weight unit.

Thanks to width and depth

of exterior dimensions of a indoor unit are 570mm each, the installation work can be conducted smoothly with a beautiful finishing in 2x2 ceiling size.

Ultra slim design at just 248mm above the ceiling

12

248

Outline drawing (Unit:mm)

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating Cooling/Heating COP Cooling/Heating Energy label Inrush current (Max. running current) kW kW kW 4.0 (1.8~4.7) 4.5 (2.0~5.4) 1.04/1.10 3.85/4.09 A/A 5(12) Cooling : Hi:42 Me:36 Lo:30 Heating : Hi:42 Me:36 Lo:32 47 Cooling : Hi:11.5 Me:9 Lo:7 Heating : Hi:11.5 Me:9 Lo:8 40 Unit:248x570x570 Panel:35x700x700 18.5(Unit:15 Panel:3.5) TC-PSA-25W-E Pocket Plastic net x1 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-TC-24W-ER 640x800(+71)x290 43 Scroll 1.4(15) 6.35/12.7 30 20 20 -15~43*2 -15~20 FDTC40ZIXVD FDTC40VD SRC40ZIX-S FDTC50ZIXVD FDTC50VD SRC50ZIX-S 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 5.0 (2.2~5.6) 5.4 (2.5~6.3) 1.56/1.45 3.21/3.72 A/A 5(14) Cooling : Hi:46 Me:39 Lo:30 Heating : Hi:46 Me:39 Lo:32 48 Cooling : Hi:13.5 Me:10 Lo:7 Heating : Hi:13.5 Me:10 Lo:8 5.6 (2.8~6.3) 6.7 (3.1~6.7) 1.99/2.08 2.81/3.22 C/C FDTC60ZIXVD FDTC60VD SRC60ZIX-S

A dB(A)

*1 Sound Ievel

Indoor Outdoor

CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Unit+Panel Panel Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm Net weight kg Type of compressor Ref.amount precharged kg(m) Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m O/U is lower difference O/U Cooling Operating temperature range Heating O/U Air flow

Indoor

Range of Outdoor unit usage

Indoor unit

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *2 :: If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 40/50/60ZIXVD 47dB Air flow: 40/50/60ZIXVD 13.5CMM

13

[ INDOOR UNIT ]
DUCT CONNECTED -High Static pressure-

FDU
Wired remote control RC-E4 RCH-E3
(Option) (Option)

CLASS

R410A
Fan control kit
(100~200Pa)

Wireless remote control

RCN-KIT3-E
(Option)

FDU 71/100/125/140VD

FDU 200/250VD

[For 200/250VD] (option)

U-FCRA

Point

1 Enhanced installation workability

Point

2 Adaptability to higher static pressures

Quiet, Lightweight and Compact


With the FDU71, the noise level is only 37dB (low), weight is only 40kg and height is only 297mm. In addition 600mm Drain Pump is mounted in FDU71/100/125/140VD. The indoor unit is completely hidden in the ceiling, so this is suitable for spaces with classy interior decoration.
Height 297mm

High static pressure of 200 Pa (FDU200/250VD) extends the degree of freedom in the designing of air conditioners.
This is a real and earnest model for duct air-conditioning. A unit external static pressure of up to 200 Pa (FDU200/250VD) is possible. Precise air flow designing is possible.
Control box Slide type fan system Thin type duct connection opening

600mm

Fan motor

High static pressure silent fan

Outline drawing (Unit:mm)


FDU71VD

FDU100,125,140VD

Installation workability
FDU200,250VD
(FDU200,250VD)
Using piping attachment that has flared connection and brazed connection ends, there is no need conduct brazing work inside the outdoor unit.
Flared connection 19.05mm
232mm

Brazed connection 22.2mm

14

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity kW ISO-T1(JIS) (Min~Max) Nominal heating capacity kW ISO-T1(JIS) (Min~Max) kW Power Consumption Cooling/Heating Cooling/Heating COP Cooling/Heating Energy label A Inrush current (Max. running current) Indoor 1 dB(A) Sound Ievel* Outdoor Indoor CMM Air flow Outdoor Pa External static pressure Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m difference O/U is lower Cooling O/U Operating temperature range Heating O/U
7.1 (3.2~8.0) 8.0 (3.6~9.0) 2.15/2.15 3.30/3.72 A/A 5(17) Hi:41 Lo:37 Cooling:51 Heating:48 Hi:20 Lo:17 Cooling:60 Heating:50 297x850x650 40

*Not available in 60Hz


*FDU71VNXVD FDU71VD
FDC71VNX

*FDU100VNXVD FDU100VD
FDC100VNX
10.0 (4.0~11.2) 11.2 (4.0~12.5)

*FDU125VNXVD FDU125VD
FDC125VNX
12.5 (5.0~14.0) 14.0 (4.0~17.0)

*FDU140VNXVD FDU140VD
FDC140VNX
14.0 (5.0~16.0) 16.0 (4.0~18.0)

1Phase 220-240V 50Hz

750x880(+88)x340 60 2.95(30) 50

2.78/2.90 3.44/3.67 4.20/4.30 3.60/3.86 3.63/3.81 3.33/3.72 A/A A/A A/A 5(25) 5(29) 5(30) Hi:42 Lo:37 Hi:43 Lo:38 Cooling:48 Heating:50 Cooling:49 Heating:52 Hi:42 Lo:33.5 Hi:34 Lo:27 100 Standard:50, Max:130 350x1,370x650 63 Procure locally Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E 1,300x970x370 105 Rotary 4.5(30) 9.52/15.88 100 30 15 -15~43*2 -20~20

Range of Outdoor unit Indoor unit usage

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity kW ISO-T1(JIS) (Min~Max) Nominal heating capacity kW ISO-T1(JIS) (Min~Max) kW Power Consumption Cooling/Heating Cooling/Heating COP Cooling/Heating Energy label A Inrush current (Max. running current) Indoor 1 dB(A) Sound Ievel* Outdoor Indoor CMM Air flow Outdoor Pa External static pressure Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m difference O/U is lower Cooling O/U Operating temperature range Heating O/U
10.0 (4.0~11.2) 11.2 (4.0~16.0) 2.78/2.90 3.60/3.86 A/A 5(16) Hi:42 Lo:37 Cooling:48 Heating:50 Hi:34 Lo:27

*Not available in 60Hz


*FDU100VSXVD FDU100VD
FDC100VSX

*FDU125VSXVD FDU125VD
FDC125VSX 3Phase 380-415V 50Hz
12.5 (5.0~14.0) 14.0 (4.0~18.0) 3.44/3.67 3.63/3.81 A/A 5(18) Hi:43 Lo:38 Cooling:48 Heating:50 Hi:42 Lo:33.5 100 Standard:50, Max:130 350x1,370x650 63 Procure locally Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E 1,300x970x370 105 Rotary 4.5(30) 9.52/15.88 100 30 15 -15~43*2 -20~20

*FDU140VSXVD FDU140VD
FDC140VSX
14.0 (5.0~16.0) 16.0 (4.0~20.0) 4.20/4.30 3.33/3.72 A/A 5(19) Cooling:49 Heating:52

Range of Outdoor unit Indoor unit usage

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static pressure of FDU71/100/125/140 is 60Pa and that of FDU200/250 is 100Pa. 1 Indicates the these somewhat higher due *2 :: External staticvalue in an anechoic chamber. During operationcontrol.values areexternal static pressure to ambient conditions. external static pressure is ''High static pressure is changeable to be set by the remote Standard is factory setting. MAX * pressure'' setting. The values of sound pressure level become 5dB(A) higher at eternal static pressure of 130Pa. *3 : If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.

15

[ INDOOR UNIT ]
DUCT CONNECTED -Middle Static pressure-

FDUM
Wired remote control Wireless remote control RC-E4
(Option)

CLASS

RCH-E3
(Option)

Filter kit UM-FL1E : for 50 UM-FL2E : for 60, 71 UM-FL3E : for 100, 125, 140 RCN-KIT3-E
(Option) (option)
external static pressure loss:5pa

FDUM 50/60/71/ 100/125/140VD

Point

1 Various Adaptability
Static pressure Pa
model 50/60/71VD 100VD 125/140VD Standard 50 60 60

Outline drawing(Unit:mm)
Model FDUM50VD
(50Hz)
Max 85 90 85

Selectable static pressure and Flexible duct design with selectable air suction (direct suction /duct suction) can meet wide pattern of installation.

Point

2 600mm Drain Pump


Flexible hose less than 600mm

Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom Depending on the installation location.

Models FDUM60V,71VD

Models FDUM100V,125V,140VD

16

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) Power Consumption Cooling/Heating kW Cooling/Heating COP Cooling/Heating Energy label Inrush current (Max. running current) A Indoor Sound Ievel*1 dB(A) Outdoor Indoor Air flow CMM Outdoor 50Hz/60Hz Static pressure Pa Exterior dimensions Height x Width x Depth mm Net weight kg Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm Net weight kg Type of compressor Ref.amount precharged kg(m) Ref.piping size Liquid/Gas Ref.piping length m Vertical height O/U is higher m difference O/U is lower m Cooling O/U Operating temperature range Heating O/U
5.0 (2.2~5.6) 5.4 (2.5~6.3) 1.52/1.41 3.29/3.83 A/A FDUM50ZIXVD FDUM50VD SRC50ZIX-S FDUM60ZIXVD FDUM60VD SRC60ZIX-S FDUM71VNVD FDUM71VD FDC71VNX FDUM100VNXVD FDUM100VD FDC100VNX

1Phase 220-240V 50Hz, 1Phase 220V 60Hz


5.6 (2.8~6.3) 6.7 (3.1~7.1) 1.86/1.96 3.01/3.42 B/B 7.1 (3.2~8.0) 8.0 (3.6~9.0) 10.0 (4.0~11.2) 11.2 (4.0~12.5)

2.14/2.16 2.72/2.95 3.32/3.70 3.68/3.80 A/A A/A 5(17) 5(24) 5(14) Hi:37 Me:35 Lo:32 Hi:35 Me:32 Lo:29 Hi:34 Me:31 Lo:28 47 Cooling:51 Heating:48 Cooling:48 Heating:50 48 Hi:16 Me:15 Lo:14 Hi:13 Me:12 Lo:11 Hi:20 Me:18 Lo:15 Hi:28 Me:25 Lo:22 40 Cooling:60 Heating:50 100 Standard:50/40, Max:85/90 Standard:50/40, Max:85/100 Standard:60/60, Max:90/100 299x750x635 299x950x635 350x1,370x635 34 40 59 Procure locally Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E 640x800(+71)x290 1,300x970x370 750x880(+88)x340 43 105 60 Rotary Scroll 1.4(15) 4.5(30) 2.95(30) 6.35/12.7 9.52/15.88 30 100 50 20 30 20 15 -15~43*2 -20~20 -15~20

Range of Outdoor unit Indoor unit usage

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) Power Consumption Cooling/Heating kW Cooling/Heating COP Cooling/Heating Energy label Inrush current (Max. running current) A Indoor Sound Ievel*1 dB(A) Outdoor Indoor Air flow CMM Outdoor 50Hz/60Hz Static pressure Pa Exterior dimensions Height x Width x Depth mm Net weight kg Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm Net weight kg Type of compressor Ref.amount precharged kg(m) Ref.piping size Liquid/Gas Ref.piping length m Vertical height O/U is higher m difference O/U is lower m Cooling O/U Operating temperature range Heating O/U
FDUM125VNXVD FDUM125VD FDC125VNX FDUM140VNXVD FDUM140VD FDC140VNX FDUM100VSXVD FDUM100VD FDC100VSX FDUM125VSXVD FDUM125VD FDC125VSX FDUM140VSXVD FDUM140VD FDC140VSX

1Phase 220-240V 50Hz, 1Phase 220V 60Hz


12.5 (5.0~14.0) 14.0 (4.0~17.0) 3.62/3.77 3.45/3.71 A/A 14.0 (5.0~16.0) 16.0 (4.0~18.0) 4.34/4.69 3.23/3.41 A/B 10.0 (4.0~11.2) 11.2 (4.0~16.0) 2.72/2.95 3.68/3.80 A/A

3Phase 380-415V 50Hz, 3Phase 380V 60Hz


12.5 (5.0~14.0) 14.0 (4.0~18.0) 14.0 (5.0~16.0) 16.0 (4.0~20.0)

4.34/4.69 3.62/3.77 3.23/3.41 3.45/3.71 A/B A/A 5(15) 5(26) Hi:37 Me:35 Lo:32 Hi:38 Me:36 Lo:33 Hi:38 Me:36 Lo:33 Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling:48 Heating:50 Cooling:49 Heating:52 Hi:28 Me:25 Lo:22 100 Standard:60/55, Max:85/100 Standard:60/55, Max:85/100 Standard:60/60, Max:90/100 350x1,370x635 59 Procure locally Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E 1,300x970x370 105 Rotary 4.5(30) 9.52/15.88 100 30 15 -15~43*2 -20~20

Range of Outdoor unit Indoor unit usage

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static pressure of indoor units is 60Pa. 1 Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *2 :: If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 50ZIXVD 35dB, 60ZIXVD 38dB, 71VNXVD 38dB, 100/125/140VNXVD 41dB, 100/125/140VSXVD 41dB Air flow: 50ZIXVD 14CMM, 60ZIXVD 18CMM, 71VNXVD 23CMM, 100/125/140VNXVD 34CMM, 100/125/140VSXVD 34CMM

17

[ INDOOR UNIT ]
CEILING SUSPENDED

FDEN

CLASS

FDEN 40/50/60/71/100/125/140VD

Wired remote control

Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-E1R
(Option)

Point

1 Improved installation workability


Up Right Rear

Point

2 Compact and modern design

Increased freedom of a piping layout


Height 210mm

The refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from the bottom.

All models fit compactly on ceiling. (Height-210mm or 250mm). Plain, modern design featuring rounded edges gives room a comfortable atmosphere. FDEN40VD, 50VD weights 30kg the lightest level in the industry. Convenient and quick installation.

Outline drawing (Unit:mm)


24 a (Suspension bolts pitch) 24 5 290(Suspension bolts pitch) 135 68 Holes for suspension bolts (M8 to M10X 4pcs.Not included) 410 145 52 Liquid piping Gas piping 100 or more Space for installation and service

300 or more

e d

150 or more

173

40

b c

40 Air outlet 690 195 235 271 Indication board Note(1) The slope of drain piping inside the unit is able to take incline of 10mm. 53 109 Drain hole connection(1) (VP20 (I.D.20))

5 or more

Obstacles

Drain hole connection(1) (VP20(I.D.20)) 76

Dimension Table
model a 1022 1272 1572 b 990 1240 1540 c 1070 1320 1620 d 215 215 255 e 210 210 250 FDEN40,50 FDEN60,71 FDEN100~140

308

Air inlet grille

Gas piping Drain hole connection(1) (VP20(I.D.20))

75 Liquid piping 110 135

18

10

53

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source

FDEN40ZIXVD FDEN40VD SRC40ZIX-S

FDEN50ZIXVD FDEN50VD SRC50ZIX-S

FDEN60ZIXVD FDEN60VD SRC60ZIX-S

FDEN71VNXVD FDEN71VD FDC71VNX

FDEN100VNXVD FDEN100VD FDC100VNX

1Phase 220-240V 50Hz, 1Phase 220V 60Hz 4.0 5.0 (1.8~4.7) (2.2~5.6) 4.5 5.4 (2.0~5.4) (2.5~6.3) 1.04/1.13 1.59/1.58 3.85/3.98 3.14/3.42 A/A B/B 5(12) Hi:39 Me:38 Lo:37 47 Hi:11 Me:9 Lo:7 40 210x1,070x690 28 7.1 10.0 (3.2~8.0) (4.0~11.2) 8.0 11.2 (3.6~9.0) (4.0~12.5) 2.11/2.11 2.80/2.88 3.36/3.79 3.57/3.89 A/A A/A 5(17) 5(24) 5(14) Hi:44 Me:41 Lo:39 Hi:41 Me:39 Lo:38 48 Cooling:51 Heating:48 Cooling:48 Heating:50 Hi:18 Me:14 Lo:12 Hi:26 Me:23 Lo:21 Hi:18 Me:14 Lo:12 100 Cooling:60 Heating:50 210x1,320x690 250x1,620x690 37 49 Pocket Plastic net x2 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-E1R 640x800(+71)x290 1,300x970x370 750x880(+88)x340 43 105 60 Scroll Rotary 1.4(15) 4.5(30) 2.95(30) 6.35/12.7 9.52/15.88 30 50 20 30 20 15 -15~43*2 -15~20 -20~20 5.6 (2.8~6.3) 6.7 (3.1~7.1) 1.95/2.12 2.87/3.16 C/D

Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) kW Power Consumption Cooling/Heating Cooling/Heating COP Cooling/Heating Energy label A Inrush current (Max. running current) Indoor *1 Sound Ievel dB(A) Outdoor Indoor Air flow CMM Outdoor Exterior dimensions Height x Width x Depth mm Net weight kg Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm Net weight kg Type of compressor Ref.amount precharged kg(m) Ref.piping size Liquid/Gas Ref.piping length m Vertical height O/U is higher m difference m O/U is lower O/U Cooling Operating temperature range Heating O/U

Range of Outdoor unit Indoor unit usage

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) kW Power Consumption Cooling/Heating Cooling/Heating COP Cooling/Heating Energy label A Inrush current (Max. running current) Indoor Sound Ievel*1 dB(A) Outdoor Indoor Air flow CMM Outdoor Exterior dimensions Height x Width x Depth mm Net weight kg Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m O/U is lower difference O/U Cooling Operating temperature range Heating O/U FDEN125VNXVD FDEN125VD FDC125VNX FDEN140VNXVD FDEN140VD FDC140VNX FDEN100VSXVD FDEN100VD FDC100VSX FDEN125VSXVD FDEN125VD FDC125VSX FDEN140VSXVD FDEN140VD FDC140VSX

1Phase 220-240V 50Hz, 1Phase 220V 60Hz 12.5 (5.0~14.0) 14.0 (4.0~17.0) 3.86/3.77 3.24/3.71 A/A 14.0 (5.0~16.0) 16.0 (4.0~18.0) 4.98/4.69 2.81/3.41 C/B 10.0 (4.0~11.2) 11.2 (4.0~16.0) 2.80/2.88 3.57/3.89 A/A

3Phase 380-415V 50Hz, 3Phase 380V 60Hz 12.5 14.0 (5.0~14.0) (5.0~16.0) 14.0 16.0 (4.0~18.0) (4.0~20.0) 3.86/3.77 4.98/4.69 3.24/3.71 2.81/3.41 A/A C/B 5(15) Hi:46 Me:44 Lo:43 Cooling:48 Heating:50 Cooling:49 Heating:52 Hi:29 Me:26 Lo:23

5(26) Hi:46 Me:44 Lo:43 Cooling:48 Heating:50 Cooling:49 Heating:52 Hi:29 Me:26 Lo:23

100

Hi:44 Me:41 Lo:39 Cooling:48 Heating:50 Hi:26 Me:23 Lo:21 100 250x1,620x690 49 Pocket Plastic net x2 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-E1R 1,300x970x370 105 Rotary 4.5(30) 9.52/15.88 50 30 15 -15~43*2 -20~20

Range of Outdoor unit Indoor unit usage

100

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *2 :: If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 40/50ZIXVD 46dB, 60ZIXVD 50dB, 71VNXVD 50dB, 100VNXVD 46dB, 125/140VNXVD 50dB, 100VSXVD 46dB, 125/140VSXVD 50dB Air flow: 40/50ZIXVD 13CMM, 60ZIXVD 22CMM, 71VNXVD 22CMM, 100VNXVD 28CMM, 125/140VNXVD 32CMM, 100VSXVD 28CMM, 125/140VSXVD 32CMM

19

Micro Inverter [ INDOOR UNIT ]


CEILING CASSETTE -4way-

FDT

CLASS

FDT 100/125/140VD

Wired remote control

Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-T-36W-E
(Option)

SPECIFICATIONS
Micro Inverter
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating Cooling/Heating COP Cooling/Heating Energy label Inrush current (Max. running current) Sound Ievel

FDT100VNVD FDT100VD FDC100VN

FDT125VNVD FDT125VD FDC125VN

FDT140VNVD FDT140VD FDC140VN

FDT100VSVD FDT100VD FDC100VS

FDT125VSVD FDT125VD FDC125VS

FDT140VSVD FDT140VD FDC140VS

1Phase 220-240V 50Hz, 1Phase 220V 60Hz

3Phase 380-415V 50Hz, 3Phase 380V 60Hz 10.0 (4.0~11.2) 11.2 (4.0~12.5) 2.76/2.74 3.62/4.09 A/A Hi:40 Me:37 Lo:35 49 Hi:27 Me:24 Lo:20 12.5 (5.0~14.0) 14.0 (4.0~16.0) 4.05/3.77 3.09/3.71 B/A 5(15) Hi:42 Me:40 Lo:37 Cooling:50 Heating:51 Hi:30 Me:27 Lo:23 Cooling:75 Heating:73 14.0 (5.0~14.5) 16.0 (4.0~16.5) 4.98/4.57 2.81/3.50 C/B Hi:43 Me:41 Lo:38 51 Hi:30 Me:27 Lo:23

kW kW kW

10.0 (4.0~11.2) 11.2 (4.0~12.5) 2.76/2.74 3.62/4.09 A/A Hi:40 Me:37 Lo:35 49 Hi:27 Me:24 Lo:20

A dB(A)

*1

Indoor Outdoor

CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Unit+Panel Panel Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m difference O/U is lower O/U Cooling Operating temperature range Heating O/U
Air flow

Indoor

12.5 (5.0~14.0) 14.0 (4.0~16.0) 4.05/3.77 3.09/3.71 B/A 5(24) Hi:42 Me:40 Lo:37 Cooling:50 Heating:51 Hi:30 Me:27 Lo:23 Cooling:75 Heating:73

14.0 (5.0~14.5) 16.0 (4.0~16.5) 4.98/4.57 2.81/3.50 C/B Hi:43 Me:41 Lo:38 51 Hi:30 Me:27 Lo:23

Range of Outdoor unit usage

Unit:298x840x840 Panel:35x950x950 32.5(Unit:27 Panel:5.5) T-PSA-3AW-E Pocket Plastic net x1 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-T-36W-E 845x970x370 81 Rotary 3.8(30) 9.52/15.88 50 30 15 -15~43*2 -20~20 83

20

Indoor unit

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *2 :: If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 100/125/140VNVD 51dB, 100/125/140VSVD 51dB Air flow: 100/125/140VNVD 37CMM, 100/125/140VSVD 37CMM

DUCT CONNECTED -High Static pressure-

FDU
FDU 100/125/140VD

CLASS

A
*

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity kW ISO-T1(JIS) (Min~Max) Nominal heating capacity kW ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating kW COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) A Indoor *1 dB(A) Sound Ievel Outdoor Indoor Air flow CMM Outdoor External static pressure Pa Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m difference O/U is lower Cooling O/U Operating temperature range Heating O/U

*FDU100VNVD FDU100VD

Not available in 60Hz Micro Inverter

*FDU125VNVD FDU125VD

Wired remote control

RC-E4
(Option)

RCH-E3
(Option)

Wireless remote control

FDU 200/250VD
Fan control kit
(100~200Pa) [For 200/250VD] (option)

RCN-KIT3-E
(Option)

U-FCRA

FDC125VN FDC100VN 1Phase 220-240V 50Hz 10.0 12.5 (4.0~11.2) (5.0~14.0) 11.2 14.0 (4.0~12.5) (4.0~16.0) 2.88/2.99 4.04/3.79 3.09/3.69 3.47/3.75 B/A A/A 5(27) 5(25) Hi:43 Lo:38 Hi:42 Lo:37 Cooling:50 Heating:51 49 Hi:42 Lo:33.5 Hi:34 Lo:27 Cooling:75 Heating:73 Standard:50, Max:130 350x1,370x650 63 Procure locally Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E 845x970x370 81 Rotary 3.8(30) 9.52/15.88 50 30 15 -15~43*3 -15~43*2 -20~20

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating COP
Cooling/Heating kW kW kW

Range of Outdoor unit Indoor unit usage

FDU140VNVD FDU140VD FDC140VN 1Phase 220-240V 50Hz 14.0 (5.0~14.5) 16.0 (4.0~16.5)
4.95/4.43 2.83/3.61 C/A 5(28) Hi:43 Lo:38 51 Hi:42 Lo:33.5

FDU100VSVD FDU100VD FDC100VS

*FDU125VSVD FDU125VD
FDC125VS 3Phase 380-415V 50Hz
12.5 (5.0~14.0) 14.0 (4.0~16.0) 4.04/3.79 3.09/3.69

Micro Inverter

*FDU140VSVD FDU140VD
FDC140VS
14.0 (5.0~14.5) 16.0 (4.0~16.5) 4.95/4.43 2.83/3.61

FDU200VSVD FDU200VD FDC200VS

FDU250VSVD FDU250VD FDC250VS

3Phase 380-415V 50Hz, 3Phase 380V 60Hz 20.0 25.0 (7.0~22.4) (10.0~28.0) 22.4 28.0 (7.6~25.0) (9.5~31.5) 50Hz:6.59/6.08 50Hz: 9.91/8.50 60Hz:6.58/5.84 60Hz:10.21/8.22 50Hz:3.03/3.68 50Hz:2.52/3.29 60Hz:3.04/3.83 60Hz:2.45/3.41 50Hz:E/C 60Hz:E/B B/A 5(27) 5(24) 52 51 Cooling:57 Heating:58 57 50Hz:68, 60Hz:80 50Hz:51, 60Hz:60 Cooling:150 Heating:145 Standard:100, Max:200 360x1,570x830 92

10.0 (4.0~11.2) 11.2 (4.0~12.5) 2.88/2.99 3.47/3.75

Cooling/Heating Energy label A Inrush current (Max. running current) Indoor 1 dB(A) Sound Ievel* Outdoor Indoor CMM Air flow Outdoor 2 Pa External static pressure * Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m O/U is lower difference O/U Cooling Operating temperature range Heating O/U

81

A/A C/A B/A 5(16) 5(19) 5(18) Hi:42 Lo:37 Hi:43 Lo:38 51 Cooling:50 Heating:51 49 Hi:34 Lo:27 Hi:42 Lo:33.5 Cooling:75 Heating:73 Standard:50, Max:130 350x1,370x650 63 Procure locally Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E 845x970x370 83 Rotary 3.8(30) 9.52/15.88 50 30 15 -15~43 *3 -20~20

Range of Outdoor unit Indoor unit usage

1,300x970x370 122 Scroll 5.4(30) 9.52/25.4 70 7.2(30) 12.7/25.4 140

-15~20

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static pressure of FDU100/125/140 is 60Pa and that of FDU200/250 is 100Pa. 1 Indicates the these somewhat higher due *2 :: External staticvalue in an anechoic chamber. During operationcontrol.values areexternal static pressure to ambient conditions. external static pressure is ''High static pressure is changeable to be set by the remote Standard is factory setting. MAX * pressure'' setting. The values of sound pressure level become 5dB(A) higher at eternal static pressure of 130Pa. *3 : If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.

21

Micro Inverter [ INDOOR UNIT ]

FDUM

DUCT CONNECTED -Low/Middle Static pressure-

CLASS

FDUM 100/125/140VD
Filter kit UM-FL3E : for 100, 125, 140
(option)
external static pressure loss:5pa

Wired remote control

Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-KIT3-E
(Option)

SPECIFICATIONS
Micro Inverter
FDUM140VSVD FDUM100VSVD FDUM125VSVD FDUM100VNVD FDUM125VNVD FDUM140VNVD FDUM140VD FDUM100VD FDUM125VD FDUM100VD FDUM125VD FDUM140VD FDC140VS FDC100VS FDC125VS FDC100VN FDC125VN FDC140VN 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 10.0 14.0 12.5 10.0 14.0 12.5 kW (4.0~11.2) (5.0~14.5) (5.0~14.0) (4.0~11.2) (5.0~14.5) (5.0~14.0) 11.2 16.0 14.0 11.2 16.0 14.0 kW (4.0~12.5) (4.0~16.5) (4.0~16.0) (4.0~12.5) (4.0~16.5) (4.0~16.0) 50Hz:2.80/2.77 50Hz:4.95/4.89 50Hz:4.03/3.80 50Hz:2.80/2.77 50Hz:4.95/4.89 50Hz:4.03/3.80 Power Consumption Cooling/Heating kW 60Hz:2.80/2.80 60Hz:4.95/4.91 60Hz:4.03/3.85 60Hz:2.80/2.80 60Hz:4.95/4.91 60Hz:4.03/3.85 50Hz:3.57/4.04 50Hz:2.83/3.27 50Hz:3.10/3.68 50Hz:3.57/4.04 50Hz:2.83/3.27 50Hz:3.10/3.68 COP Cooling/Heating 60Hz:3.57/4.00 60Hz:2.83/3.26 60Hz:3.10/3.64 60Hz:3.57/4.00 60Hz:2.83/3.26 60Hz:3.10/3.64 Energy label A/A C/C B/A A/A C/C B/A Cooling/Heating 5(24) 5(15) Inrush current (Max. running current) A Hi:37 Me:35 Lo:32 Hi:38 Me:36 Lo:33 Hi:38 Me:36 Lo:33 Hi:37 Me:35 Lo:32 1 Indoor dB(A) Sound Ievel* 49 Cooling:50 Heating:51 51 49 Cooling:50 Heating:51 51 Outdoor Hi:28 Me:25 Lo:22 Indoor Air flow CMM Cooling:75 Heating:73 Outdoor Standard:60, Max:90/100 Standard:60/55, Max:85/100 Standard:60, Max:90/100 Standard:60/55, Max:85/100 Static pressure Pa Exterior dimensions Height x Width x Depth mm 350x1,370x635 Net weight kg 59 Air filter, Q'ty Procure locally Remote control(option) Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E Exterior dimensions Height x Width x Depth mm 845x970x370 Net weight kg 81 83 Type of compressor Rotary Ref.amount precharged kg(m) 3.8(30) Ref.piping size Liquid/Gas 9.52/15.88 Ref.piping length m 50 Vertical height O/U is higher m 30 difference m 15 O/U is lower Cooling O/U -15~43*2 Operating temperature range Heating O/U -20~20 Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max)

22

Range of Outdoor unit Indoor unit usage

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static pressure of indoor units is 60Pa. 1 Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *2 :: If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 100/125/140VNVD 41dB, 100/125/140VSVD 41dB Air flow: 100/125/140VNVD 34CMM, 100/125/140VSVD 34CMM

FDEN

CEILING SUSPENDED

CLASS

FDEN 100/125/140VD

Wired remote control

Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-E1R
(Option)

SPECIFICATIONS
Micro Inverter
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current)

kW kW kW

A dB(A)

*1 Sound Ievel

Indoor Outdoor

CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight Type of compressor kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m difference O/U is lower O/U Cooling Operating temperature range Heating O/U

Air flow

Indoor

FDEN140VNVD FDEN125VNVD FDEN100VNVD FDEN100VSVD FDEN125VSVD FDEN140VSVD FDEN100VD FDEN125VD FDEN140VD FDEN140VD FDEN125VD FDEN100VD FDC100VS FDC125VS FDC140VS FDC140VN FDC125VN FDC100VN 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 12.5 14.0 10.0 10.0 12.5 14.0 (5.0~14.5) (4.0~11.2) (4.0~11.2) (5.0~14.0) (5.0~14.5) (5.0~14.0) 16.0 14.0 11.2 11.2 14.0 16.0 (4.0~16.5) (4.0~16.0) (4.0~12.5) (4.0~12.5) (4.0~16.0) (4.0~16.5) 5.80/4.92 4.45/4.08 2.85/2.97 2.85/2.97 4.45/4.08 5.80/4.92 3.51/3.77 2.41/3.25 2.80/3.43 3.51/3.77 2.80/3.43 2.41/3.25 A/A E/C C/B A/A C/B E/C 5(24) 5(15) Hi:44 Hi:44 Hi:46 Me:44 Lo:43 Hi:46 Me:44 Lo:43 Me:41 Lo:39 Me:41 Lo:39 49 49 Cooling:50 Heating:51 Cooling:50 Heating:51 51 51 Hi:26 Hi:26 Hi:29 Me:26 Lo:23 Hi:29 Me:26 Lo:23 Me:23 Lo:21 Me:23 Lo:21 Cooling:75 Heating:73 250x1,620x690 49 Pocket Plastic net x2 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-E1R 845x970x370 81 83 Rotary 3.8(30) 9.52/15.88 50 30 15 -15~43*2 -20~20

Range of Outdoor unit Indoor unit usage

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *2 :: If a cooling operation is conducted when the outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 100VNVD 46dB, 125/140VNVD 50dB, 100VSVD 46dB, 125/140VSVD 50dB Air flow: 100VNVD 28CMM, 125/140VNVD 32CMM, 100VSVD 28CMM, 125/140VSVD 32CMM

23

MULTI SYSTEM
Up to Four indoor units can be connected to a single outdoor unit and simultaneously operated with a single remote control.

Twin / Triple / Double Twin Multi System


By referring to the following table for applicable indoor units, select the same models and capacities.
Applicable indoor units
Model Capacity Combination

4way

4way compact (600 x 600mm)

Low/Middle Static pressure Ceiling Suspended

Wall Mounted
Only used with outdoor units of Multi System

Combination of indoor units

Micro Inverter
NEW

FDC125VNX FDC140VNX FDC100VNV FDC125VNV FDC140VNV FDC71VNX FDC100VNX FDC125VSX FDC140VSX FDC100VSV FDC125VSV FDC140VSV FDC200VSV FDC250VSV FDC100VSX 40 + 40 50 + 50 60 + 60 71 + 71 50 + 50 60 + 60 71 + 71 100 + 100 125 + 125 50 + 50 + 50 50 + 50 + 50 71 + 71 + 71 50+50+50+50 60+60+60+60

Decision of piping specification Twin type


Models FDC71VNX, FDC100~140VNV/VSV
[Branch pipe set : DIS-WA1]
Gas line 4 L 4 Liquid line 3
Gas pipe Symbol
48 ID15.88 ID15.88 11 11 24 ID9.52

Diagrams below show the application as samples. For further information, refer to TECHNICAL MANUAL.

(Example)

Item Model FDC71 FDC100 FDC125 FDC140

Indoor unit

Outdoor unit

Indoor unit combinations 40+40 50+50 60+60 71+71

Liquid pipe Main pipe Branch pipe

Gas pipe Main pipe Branch pipe 12.7Xt 0.8

The branch piping (both gas and liquid lines) should always be arranged to have a level or perpendicular position.

9.52Xt 0.8 9.52Xt 0.8 15.88Xt1.0 15.88Xt1.0

2-Way Branch

Notes (1) When 40-60 models of indoor units are applied to this combination, the reducer 3 supplied with the branch piping set should be used in order to reduce the liquid piping size from 9.52mm to 6.35mm at indoor unit side (are connection). Accordingly be sure to select the liquid piping size 9.52mm from branch to indoor unit. (2) The reducer 4 is for FDC71 and 100 models only.

Floor

Floor

Mount sections level with the floor.

Mount sections perpendicular to the floor.

Liquid pipe
ID9.52 180

Symbol

Reducer
6.35 flared nut 50 105 2 piece

Symbol

Reducer
OD15.88 80 ID12.7 10 2 piece

Symbol

Chart of shapes of branch piping parts (DIS-WA1)

3-Way Branch

8 ID9.52 210

ID9.52 8

ID15.88

Notes (1) Symbol 1 to 4 in the drawing shows the symbols of branch piping parts in the chart respectively. (2) Branch piping should always be arranged to have level or perpendicular position.

Floor

Floor

24

Ideal for the installation in large area and L-shaped rooms, the V Multi System has an extensive degree of flexibility in the selection of indoor units. Specifically, the selection of indoor units with different capacities in different types can be made.

V Multi System
Different models and capacities can be selected.

Applicable indoor units


Model Capacity

4way

Ceiling Suspended

Combination of indoor units

NEW

FDC71VNX

FDC100VNX FDC100VSX FDC100VNV FDC100VSV

FDC125VNX FDC125VSX FDC125VNV FDC125VSV 60 + 60 50 + 71

FDC140VNX FDC140VSX FDC140VNV FDC140VSV 71 + 71 50 + 50 + 50 FDC200VSV 100 + 100 71 + 125 71 + 71 + 71 FDC250VSV 125 + 125 60 + 60 + 125 71 + 71 + 100

Micro Inverter
40 + 40

50 + 50

50+50+50+50 60+60+60+60

Triple type
[Branch pipe set : DIS-TA1]

The indoor_outdoor piping length differences among indoor units are less than 3m.
(Example)

Model FDC140VNV/VSV
Indoor unit
Model FDC140 Item Indoor unit combinations 50+50+50 Liquid pipe Main pipe Branch pipe 9.52X t0.8 9.52Xt 0.8 Gas pipe Main pipe Branch pipe 15.88Xt 1.0 12.7X t0.8

3 Gas line
Floor

Outdoor unit L Liquid line

Notes (1) The reducer 3 supplied with the branch piping set should be used in order to reduce the liquid piping size from 9.52mm to 6.35mm at indoor unit side (are connection). Accordingly be sure to select the liquid piping size 9.52mm from branch to indoor unit.

Gas pipe

Symbol
ID12.7x3 100

Liquid pipe
10 0

Symbol
ID9.52x3

Reducer

Symbol

8 10 300 8 237

30

Chart of shapes of branch piping parts (DIS-TA1)


3

100

80 80

30

ID15.88

10

ID9.52

ID9.52 8 105 50

6.35 flared nut

14

Floor

Notes (1) Symbol 1 to 3 in the drawing shows the symbols of branch piping parts in the chart respectively. (2) Branch piping should always be arranged to have level or perpendicular position.

25

MULTI [ INDOOR UNIT ]


CEILING CASSETTE -4way-

FDT

CLASS

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.


FDT100VNXPVD FDT71VNXPVD Twin FDT40VD FDT50VD FDC71VNX FDC100VNX

FDT 40/50/60/71/100/125VD

Wired remote control

Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-T-36W-E
(Option)

Indoor name Outdoor name Power source 1Phase 220-240V 50Hz, 1Phase 220V 60Hz Nominal cooling capacity 7.1 10.0 kW ISO-T1(JIS) (3.2~8.0) (4.0~11.2) (Min~Max) Nominal heating capacity 8.0 11.2 kW ISO-T1(JIS) (3.6~9.0) (4.0~12.5) (Min~Max) Power Consumption Cooling/Heating kW 1.85/1.99 2.56/2.66 COP Cooling/Heating 3.84/4.02 3.91/4.21 Energy label Cooling/Heating A/A A/A Inrush current (Max. running current) A 5(24) 5(17) Hi:33 Me:31 Lo:30 Indoor*2 Sound Ievel*1 dB(A) Cooling:51 Heating:48 Cooling:48 Heating:50 Outdoor 2 Hi:18 Me:16 Lo:14 Indoor* Air flow CMM Cooling:60 Heating:50 Outdoor 100 Exterior dimensions Height x Width x Depth mm Unit:246x840x840 Panel:35x950x950 kg Unit+Panel Net weight 27.5(Unit:22 Panel:5.5) Panel T-PSA-3AW-E Air filter, Q'ty Pocket Plastic net x1 (Washable) Remote control(option) Wired:RC-E4, RCH-E3 Wireless:RCN-T-36W-E Exterior dimensions Height x Width x Depth mm 750x880(+88)x340 1,300x970x370 Net weight kg 105 60 kg(m) Ref.amount precharged 4.5(30) 2.95(30) Ref.piping size Liquid/Gas 9.52/15.88 m Ref.piping length 100 50 m Vertical height O/U is higher 30 m difference O/U is lower 15 Operating O/U Cooling -15~43*3 temperature range Heating O/U -20~20

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.


FDT125VNXPVD FDT140VNXPVD FDT140VNXTVD FDT100VSXPVD FDT125VSXPVD FDT140VSXPVD FDT140VSXTVD Twin Triple Twin Triple FDT50VD FDT60VD FDT71VD FDT50VD FDT71VD FDT50VD FDT60VD FDC140VNX FDC125VSX FDC140VSX FDC140VSX FDC140VNX FDC100VSX FDC125VNX

Indoor name Outdoor name Power source 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 3Phase 380-415V 50Hz, 3Phase 380V 60Hz Nominal cooling capacity 14.0 12.5 14.0 10.0 12.5 14.0 14.0 kW ISO-T1(JIS) (5.0~16.0) (5.0~14.0) (5.0~16.0) (4.0~11.2) (5.0~14.0) (5.0~14.5) (5.0~14.5) (Min~Max) Nominal heating capacity 16.0 14.0 16.0 11.2 14.0 16.0 16.0 kW ISO-T1(JIS) (4.0~18.0) (4.0~17.0) (4.0~18.0) (4.0~16.0) (4.0~18.0) (4.0~20.0) (4.0~20.0) (Min~Max) Power Consumption Cooling/Heating kW 3.88/3.70 3.06/3.22 3.88/3.76 2.56/2.66 3.06/3.22 3.88/3.70 3.88/3.76 COP Cooling/Heating 3.61/4.32 4.08/4.35 3.61/4.26 3.91/4.21 4.08/4.35 3.61/4.32 3.61/4.26 Energy label Cooling/Heating A/A A/A A/A A/A A/A A/A A/A Inrush current (Max. running current) A 5(26) 5(15) 2 Hi:33 Me:31 Lo:30 Hi:35 Me:33 Lo:31 Hi:33 Me:31 Lo:30 Hi:33 Me:31 Lo:30 Hi:35 Me:33 Lo:31 Hi:33 Me:31 Lo:30 Indoor* Sound Ievel*1 dB(A) Cooling:48 Heating:50 Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling:49 Heating:52 Outdoor Hi:18 Me:16 Lo:14 Hi:21 Me:19 Lo:17 Hi:18 Me:16 Lo:14 Indoor*2 Hi:21 Me:19 Lo:17 Hi:18 Me:16 Lo:14 Hi:18 Me:16 Lo:14 Air flow CMM 100 Outdoor Exterior dimensions Height x Width x Depth mm Unit:246x840x840 Panel:35x950x950 kg Unit+Panel Net weight 27.5(Unit:22 Panel:5.5) 29.5(Unit:24 Panel:5.5) 27.5(Unit:22 Panel:5.5) 29.5(Unit:24 Panel:5.5) Panel T-PSA-3AW-E Air filter, Q'ty Pocket Plastic net x1 (Washable) Remote control(option) Wired:RC-E4, RCH-E3 Wireless:RCN-T-36W-E Exterior dimensions Height x Width x Depth mm 1,300x970x370 Net weight kg 105 kg(m) Ref.amount precharged 4.5(30) Ref.piping size Liquid/Gas 9.52/15.88 m Ref.piping length 100 m Vertical height O/U is higher 30 m difference O/U is lower 15 Operating O/U Cooling -15~43*3 temperature range Heating O/U -20~20

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 71/100VNXPVD 39dB, 100VSXPVD 39dB, 125/140VNXPVD 46dB, 125/140VSXPVD 46dB, 140VNXTVD 39dB, 140VSXTVD 39dB Air flow: 71/100VNXPVD 20CMM, 100VSXPVD 20CMM, 125/140VNXPVD 28CMM, 125/140VSXPVD 28CMM, 140VNXTVD 20CMM, 140VSXTVD 20CMM

26

Range of Outdoor unit usage

Indoor unit

Range of Outdoor unit usage

Indoor unit

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.

Micro Inverter
FDT100VNPVD FDT125VNPVD FDT140VNPVD FDT140VNTVD FDT100VSPVD FDT125VSPVD FDT140VSPVD Twin Triple Twin Indoor name FDT50VD FDT50VD FDT60VD FDT71VD FDT71VD FDT50VD FDT60VD Outdoor name FDC140VN FDC125VS FDC140VS FDC100VS FDC140VN FDC100VN FDC125VN Power source 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 3Phase 380-415V 50Hz, 3Phase 380V 60Hz Nominal cooling capacity 10.0 14.0 10.0 12.5 14.0 12.5 14.0 kW ISO-T1(JIS) (4.0~11.2) (5.0~14.5) (4.0~11.2) (5.0~14.0) (5.0~14.5) (5.0~14.0) (5.0~14.5) (Min~Max) Nominal heating capacity 11.2 16.0 11.2 14.0 16.0 14.0 16.0 kW ISO-T1(JIS) (4.0~12.5) (4.0~16.5) (4.0~12.5) (4.0~16.0) (4.0~16.5) (4.0~16.0) (4.0~16.5) (Min~Max) Power Consumption Cooling/Heating kW 2.94/3.09 4.65/4.63 2.94/3.09 3.95/3.70 4.51/4.58 3.95/3.70 4.51/4.58 COP Cooling/Heating 3.40/3.62 3.01/3.46 3.40/3.62 3.16/3.78 3.10/3.49 3.16/3.78 3.10/3.49 Energy label Cooling/Heating A/A B/B A/A B/A B/B B/A B/B 5(15) Inrush current (Max. running current) A 5(24) Hi:33 Hi:35 Hi:33 Hi:33 Hi:33 Hi:35 Hi:33 Indoor*2 *1 Sound Ievel dB(A) Me:31 Lo:30 Me:33 Lo:31 Me:31 Lo:30 Me:31 Lo:30 Me:31 Lo:30 Me:33 Lo:31 Me:31 Lo:30 49 Cooling:50 Heating:51 51 Outdoor Cooling:50 Heating:51 49 51 Hi:21 Hi:18 Hi:21 *2 Hi:18 Me:16 Lo:14 Hi:18 Me:16 Lo:14 Indoor Me:19 Lo:17 Me:16 Lo:14 Air flow CMM Me:19 Lo:17 Cooling:75 Heating:73 Outdoor Exterior dimensions Height x Width x Depth mm Unit:246x840x840 Panel:35x950x950 29.5(Unit:24 Panel:5.5) 29.5(Unit:24 Panel:5.5) 27.5(Unit:22 Panel:5.5) kg 27.5(Unit:22 Panel:5.5) Net weight Unit+Panel Panel T-PSA-3AW-E Air filter, Q'ty Pocket Plastic net x1 (Washable) Remote control(option) Wired:RC-E4, RCH-E3 Wireless:RCN-T-36W-E Exterior dimensions 845x970x370 Net weight kg 81 83 Ref.amount precharged kg(m) 3.8(30) Ref.piping size Liquid/Gas 9.52/15.88 m 50 Ref.piping length m 30 Vertical height O/U is higher O/U is lower m 15 difference Cooling Operating O/U -15~43*3 temperature range Heating O/U -20~20 Powerful-Hi can be selected. Sound level: 100VNPVD 39dB, 125/140VNPVD 46dB, 140VNTVD 39dB, 100VSPVD 39dB, 125/140VSPVD 46dB Air flow: 100VNPVD 20CMM, 125/140VNPVD 28CMM, 140VNTVD 20CMM, 100VSPVD 20CMM, 125/140VSPVD 28CMM

Range of Outdoor unit usage

Indoor unit

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.

Micro Inverter
FDT140VSTVD FDT200VSTVD FDT200VSDVD FDT250VSDVD Triple Double Twin Indoor name FDT50VD FDT71VD FDT50VD FDT60VD Outdoor name FDC140VS FDC200VS FDC200VS FDC250VS Power source 3Phase 380-415V 50Hz, 3Phase 380V 60Hz Nominal cooling capacity 25.0 14.0 20.0 20.0 25.0 20.0 kW ISO-T1(JIS) (10.0~28.0) (5.0~14.5) (7.0~22.4) (7.0~22.4) (10.0~28.0) (7.0~22.4) (Min~Max) Nominal heating capacity 28.0 16.0 22.4 22.4 28.0 22.4 kW ISO-T1(JIS) (9.5~31.5) (4.0~16.5) (7.6~25.0) (7.6~25.0) (9.5~31.5) (7.6~25.0) (Min~Max) Power Consumption Cooling/Heating kW 8.30/7.75 4.65/4.63 6.49/6.12 6.58/6.15 8.28/7.70 6.58/6.02 COP Cooling/Heating 3.01/3.61 3.01/3.46 3.08/3.66 3.04/3.64 3.02/3.64 3.04/3.72 Energy label Cooling/Heating B/A B/B B/A B/A B/A B/A Inrush current (Max. running current) A 5(22) 5(15) 5(19) 5(19) 5(22) 5(19) Hi:42 Hi:40 Hi:33 Hi:35 Hi:33 Hi:33 Indoor*2 Sound Ievel*1 Me:40 Lo:37 Me:37 Lo:35 Me:31 Lo:30 Me:33 Lo:31 dB(A) Me:31 Lo:30 Me:31 Lo:30 51 57 57 Cooling:57 Heating:58 Outdoor 57 Cooling:57 Heating:58 Hi:27 Hi:21 Hi:18 Hi:30 Hi:18 Indoor*2 Me:24 Lo:20 Me:19 Lo:17 Air flow CMM Me:16 Lo:14 Me:27 Lo:23 Me:16 Lo:14 Cooling:150 Heating:145 Cooling:75 Heating:73 Cooling:150 Heating:145 Cooling:150 Heating:145 Outdoor Exterior dimensions Height x Width x Depth mm Unit:298x840x840 Panel:35x950x950 Unit:246x840x840 Panel:35x950x950 27.5(Unit:22 Panel:5.5) 29.5(Unit:24 Panel:5.5) 27.5(Unit:22 Panel:5.5) 29.5(Unit:24 Panel:5.5) kg Unit+Panel Net weight 32.5(Unit:27 Panel:5.5) Panel T-PSA-3AW-E Air filter, Q'ty Pocket Plastic net x1 (Washable) Remote control(option) Wired:RC-E4, RCH-E3 Wireless:RCN-T-36W-E 1,505x970x370 1,300x970x370 1,505x970x370 Exterior dimensions Height x Width x Depth mm 1,300x970x370 845x970x370 kg 140 122 140 Net weight 122 83 kg(m) 7.2(30) 5.4(30) 7.2(30) Ref.amount precharged 5.4(30) 3.8(30) 12.7/22.22 9.52/22.22 12.7/22.22 Ref.piping size Liquid/Gas 9.52/22.22 9.52/15.88 Ref.piping length m 70 70 50 Vertical height O/U is higher m 30 O/U is lower difference m 15 O/U Cooling Operating -15~43*3 O/U temperature range Heating -15~20 -20~20 -15~20 The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. FDT250VSPVD FDT200VSPVD Twin FDT125VD FDT100VD FDC250VS FDC200VS Range of Outdoor unit usage Indoor unit Powerful-Hi can be selected. Sound level: 200/250VSPVD 51dB, 140VSTVD 39dB, 200VSTVD 46dB, 200VSDVD 39dB, 250VSDVD 46dB Air flow: 200/250VSPVD 37CMM, 140VSTVD 20CMM, 200VSTVD 28CMM, 200VSDVD 20CMM, 250VSDVD 28CMM

27

MULTI [ INDOOR UNIT ]


CEILING CASSETTE -4way Compact (600 X 600mm)-

FDTC

CLASS

FDTC 40/50/60VD

Wired remote control

Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-TC-24W-ER
(Option)

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) *1 Sound Ievel Air flow Indoor*2 Outdoor Indoor*2

The values are for simultaneous Multi operation.


FDTC71VNXPVD FDTC100VNXPVD FDTC125VNXPVD FDTC140VNXTVD FDTC100VSXPVD FDTC125VSXPVD FDTC140VSXTVD Twin Triple Twin Triple FDTC60VD FDTC50VD FDTC50VD FDTC40VD FDTC50VD FDTC60VD FDTC50VD FDC125VSX FDC140VSX FDC100VSX FDC71VNX FDC100VNX FDC125VNX FDC140VNX 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 14.0 12.5 7.1 10.0 14.0 10.0 12.5 (5.0~14.0) (5.0~16.0) (3.2~8.0) (4.0~11.2) (5.0~16.0) (4.0~11.2) (5.0~14.0) 14.0 16.0 8.0 11.2 16.0 11.2 14.0 (4.0~18.0) (4.0~17.0) (3.6~9.0) (4.0~12.5) (4.0~20.0) (4.0~16.0) (4.0~18.0) 4.10/4.10 4.34/4.34 1.99/2.18 2.78/3.02 4.34/4.34 2.78/3.02 4.10/4.10 3.05/3.41 3.23/3.69 3.57/3.67 3.60/3.71 3.23/3.69 3.60/3.71 3.05/3.41 A/A B/B A/A A/A A/A A/A B/B 5(17) 5(24) 5(15) 5(26) Cooling : Hi:42 Me:36 Lo:30 Cooling : Hi:46 Me:39 Lo:30 Cooling : Hi:42 Me:36 Lo:30 Cooling : Hi:46 Me:39 Lo:30 Cooling : Hi:42 Me:36 Lo:30 Heating : Hi:42 Me:36 Lo:32 Heating : Hi:46 Me:39 Lo:32 Heating : Hi:42 Me:36 Lo:32 Heating : Hi:46 Me:39 Lo:32 Heating : Hi:42 Me:36 Lo:32 Cooling:51 Heating:48 Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling : Hi:13.5 Me:10 Lo:7 Cooling : Hi:11.5 Me:9 Lo:7 Cooling : Hi:13.5 Me:10 Lo:7 Cooling : Hi:11.5 Me:9 Lo:7 Cooling : Hi:11.5 Me:9 Lo:7 Heating : Hi:13.5 Me:10 Lo:8 Heating : Hi:11.5 Me:9 Lo:8 Heating : Hi:13.5 Me:10 Lo:8 Heating : Hi:11.5 Me:9 Lo:8 Heating : Hi:11.5 Me:9 Lo:8 100 Cooling:60 Heating:50 Unit:248x570x570 Panel:35x700x700 18.5(Unit:15 Panel:3.5) TC-PSA-25W-E Pocket Plastic net x1 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-TC-24W-ER 1,300x970x370 750x880(+88)x340 105 60 4.5(30) 2.95(30) 9.52/15.88 100 50 30 15 -15~43*3 -20~20

kW kW kW A dB(A)

CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Unit+Panel Panel Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm Net weight kg kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m O/U is lower difference Operating O/U Cooling temperature range Heating O/U

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 71/100/125VNXPVD 47dB, 100/125VSXPVD 47dB, 140VNXTVD 47dB, 140VSXTVD 47dB Air flow: 71/100/125VNXPVD 13.5CMM, 100/125VSXPVD 13.5CMM, 140VNXTVD 13.5CMM, 140VSXTVD 13.5CMM

28

Range of Outdoor unit usage

Indoor unit

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) Sound Ievel Air flow Indoor unit *1 Indoor*2 Outdoor Indoor*2

The values are for simultaneous Multi operation.

Micro Inverter
FDTC100VNPVD Twin FDTC50VD FDC100VN kW kW kW A dB(A) 10.0 (4.0~11.2) 11.2 (4.0~12.5) 2.84/3.08 3.52/3.64 A/A 5(24) Cooling : Hi:42 Me:36 Lo:30 Heating : Hi:42 Me:36 Lo:32 49 Cooling : Hi:11.5 Me:9 Lo:7 Heating : Hi:11.5 Me:9 Lo:8 FDTC60VD FDC125VN 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 12.5 (5.0~14.0) 14.0 (4.0~16.0) 5.35/4.62 2.34/3.03 F/D 5(27) Cooling : Hi:46 Me:39 Lo:30 Heating : Hi:46 Me:39 Lo:32 Cooling:50 Heating:51 Cooling : Hi:13.5 Me:10 Lo:7 Heating : Hi:13.5 Me:10 Lo:8 Cooling:75 Heating:73 Unit:248x570x570 Panel:35x700x700 18.5(Unit:15 Panel:3.5) TC-PSA-25W-E Pocket Plastic net x1 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-TC-24W-ER 845x970x370 81 3.8(30) 9.52/15.88 50 30 15 -15~43*3 -20~20 FDTC125VNPVD FDTC140VNTVD Triple FDTC50VD FDC140VN 14.0 (5.0~14.5) 16.0 (4.0~16.5) 4.64/4.52 3.02/3.54 B/B 5(24) Cooling : Hi:42 Me:36 Lo:30 Heating : Hi:42 Me:36 Lo:32 51 Cooling : Hi:11.5 Me:9 Lo:7 Heating : Hi:11.5 Me:9 Lo:8

CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Unit+Panel Panel Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher O/U is lower m difference O/U Cooling Operating temperature range Heating O/U

Range of Outdoor unit usage

Powerful-Hi can be selected. Sound level: 100/125VNPVD 47dB, 140VNTVD 47dB Air flow: 100/125VNPVD 13.5CMM, 140VNTVD 13.5CMM

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.

Micro Inverter
FDTC140VSTVD FDTC200VSDVD FDTC250VSDVD Twin Triple Double Twin Indoor name FDTC60VD FDTC50VD FDTC50VD FDTC60VD FDTC50VD Outdoor name FDC125VS FDC140VS FDC200VS FDC250VS FDC100VS Power source 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 20.0 25.0 14.0 Nominal cooling capacity 12.5 10.0 kW ISO-T1(JIS) (7.0~22.4) (10.0~28.0) (5.0~14.5) (5.0~14.0) (4.0~11.2) (Min~Max) 22.4 28.0 16.0 Nominal heating capacity 14.0 11.2 kW ISO-T1(JIS) (7.6~25.0) (9.5~31.5) (4.0~16.5) (4.0~16.0) (4.0~12.5) (Min~Max) 7.33/6.98 11.28/10.19 4.64/4.52 Power Consumption Cooling/Heating kW 5.35/4.62 2.84/3.08 2.73/3.21 2.22/2.75 3.02/3.54 COP Cooling/Heating 2.34/3.03 3.52/3.64 D/C F/E B/B Energy label Cooling/Heating F/D A/A 5(19) 5(22) 5(15) Inrush current (Max. running current) A 5(15) 5(15) Cooling : Hi:42 Me:36 Lo:30 Cooling : Hi:46 Me:39 Lo:30 Cooling : Hi:42 Me:36 Lo:30 Cooling : Hi:46 Me:39 Lo:30 *1 Indoor*2 Sound Ievel Heating : Hi:42 Me:36 Lo:32 Heating : Hi:46 Me:39 Lo:32 dB(A) Heating : Hi:42 Me:36 Lo:32 Heating : Hi:46 Me:39 Lo:32 Cooling:57 Heating:58 Cooling:50 Heating:51 Outdoor 51 57 49 Cooling : Hi:11.5 Me:9 Lo:7 Cooling : Hi:13.5 Me:10 Lo:7 Cooling : Hi:13.5 Me:10 Lo:7 Cooling : PHi:11.5 Me:9 Lo:7 Indoor*2 Air flow Heating : Hi:13.5 Me:10 Lo:8 Heating : Hi:11.5 Me:9 Lo:8 CMM Heating : Hi:11.5 Me:9 Lo:8 Heating : Hi:13.5 Me:10 Lo:8 Cooling:150 Heating:145 Cooling:75 Heating:73 Outdoor Unit:248x570x570 Panel:35x700x700 Exterior dimensions Height x Width x Depth mm 18.5(Unit:15 Panel:3.5) Unit+Panel kg Net weight TC-PSA-25W-E Panel Pocket Plastic net x1 (Washable) Air filter, Q'ty Wired:RC-E4, RCH-E3 Wireless:RCN-TC-24W-ER Remote control(option) 1,505x970x370 1,300x970x370 845x970x370 Exterior dimensions Height x Width x Depth mm 140 122 83 kg Net weight 7.2(30) 5.4(30) 3.8(30) kg(m) Ref.amount precharged 9.52/22.22 12.7/22.22 9.52/15.88 Ref.piping size Liquid/Gas 50 Ref.piping length m 70 Vertical height O/U is higher 30 m 15 difference m O/U is lower Operating -15~43*3 O/U Cooling temperature range Heating -20~20 -15~20 O/U FDTC100VSPVD FDTC125VSPVD

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 100/125VSPVD 47dB, 140VSTVD 47dB, 200/250VSDVD 47dB Air flow: 100/125VSPVD 13.5CMM, 140VSTVD 13.5CMM, 200/250VSDVD 13.5CMM

Range of Outdoor unit usage

Indoor unit

29

MULTI [ INDOOR UNIT ]


DUCT CONNECTED -Low/Middle Static pressure-

FDUM
external static pressure loss:5pa

CLASS

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.


FDUM100VNXPVD FDUM125VNXPVD Twin FDUM50VD FDUM60VD FDC100VNX FDC125VNX 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 10.0 12.5 (4.0~11.2) (5.0~14.0) 11.2 14.0 (4.0~12.5) (4.0~17.0) 2.94/2.94 3.86/4.10 3.40/3.81 3.24/3.41 A/A A/B 5(24) 5(26) Hi:34 Me:31 Lo:28 Cooling:48 Heating:50 Hi:13 Me:12 Lo:11 Hi:16 Me:15 Lo:14 100 299x750x635 299x950x635 34 40 Procure locally Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E 1,300x970x370 105 4.5(30) 9.52/15.88 100 30 15 -15~43*3 -20~20

FDUM 50/60/71/ 100/125VD


Filter kit UM-FL1E : for 50 UM-FL2E : for 60, 71 UM-FL3E : for 100, 125
(option)

Wired remote control

Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-KIT3-E
(Option)

Indoor name Outdoor name Power source Nominal cooling capacity kW ISO-T1(JIS) (Min~Max) Nominal heating capacity kW ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating kW COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) A Indoor*2 Sound Ievel*1 dB(A) Outdoor Indoor*2 Air flow CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm Net weight kg Ref.amount precharged kg(m) Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m O/U is lower difference Operating O/U Cooling temperature range Heating O/U

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating COP Cooling/Heating

The values are for simultaneous Multi operation.


FDUM140VNXPVD FDUM140VNXTVD FDUM100VSXPVD FDUM125VSXPVD FDUM140VSXPVD FDUM140VSXTVD Twin Triple Twin Triple FDUM60VD FDUM71VD FDUM50VD FDUM50VD FDUM71VD FDUM50VD FDC125VSX FDC140VSX FDC140VSX FDC140VNX FDC140VNX FDC100VSX 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 12.5 10.0 14.0 14.0 14.0 14.0 (5.0~14.0) (4.0~11.2) (5.0~16.0) (5.0~16.0) (5.0~16.0) (5.0~16.0) 14.0 11.2 16.0 16.0 16.0 16.0 (4.0~18.0) (4.0~16.0) (4.0~20.0) (4.0~18.0) (4.0~18.0) (4.0~20.0) 4.60/4.69 3.04/3.41 4.60/4.69 3.04/3.41 2.94/2.94 3.40/3.81 3.86/4.10 3.24/3.41 4.60/4.69 3.04/3.41 4.60/4.69 3.04/3.41

kW kW kW

Energy label Cooling/Heating B/B B/B B/B A/A A/B B/B Inrush current (Max. running current) A 5(15) 5(26) Indoor*2 Hi:35 Me:32 Lo:29 Hi:34 Me:31 Lo:28 Hi:35 Me:32 Lo:29 Hi:34 Me:31 Lo:28 Sound Ievel*1 dB(A) Cooling:49 Heating:52 Cooling:49 Heating:52 Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling:49 Heating:52 Outdoor Indoor*2 Hi:20 Me:18 Lo:15 Hi:13 Me:12 Lo:11 Hi:13 Me:12 Lo:11 Hi:16 Me:15 Lo:14 Hi:20 Me:18 Lo:15 Hi:13 Me:12 Lo:11 Air flow CMM Outdoor 100 Exterior dimensions Height x Width x Depth mm 299x750x635 299x950x635 299x950x635 299x750x635 kg Net weight 34 40 40 34 Air filter, Q'ty Procure locally Remote control(option) Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E Exterior dimensions Height x Width x Depth mm 1,300x970x370 kg Net weight 105 kg(m) Ref.amount precharged 4.5(30) Ref.piping size Liquid/Gas 9.52/15.88 m 100 Ref.piping length m 30 Vertical height O/U is higher m O/U is lower 15 difference Operating O/U Cooling -15~43*3 temperature range Heating O/U -20~20

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 100VNXPVD 35dB, 100VSXPVD 35dB, 125/140VNXPVD 38dB, 125/140VSXPVD 38dB, 140VNXTVD 35dB, 140VSXTVD 35dB Air flow: 100VNXPVD 14CMM, 100VSXPVD 14CMM, 125/140VNXPVD 18CMM, 125/140VSXPVD 18CMM, 140VNXTVD 14CMM, 140VSXTVD 14CMM

30

Range of Outdoor unit Indoor unit usage

Range of Outdoor unit Indoor unit usage

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating COP Cooling/Heating

The values are for simultaneous Multi operation.

Micro Inverter
FDUM100VNPVD FDUM50VD FDC100VN 10.0 (4.0~11.2) 11.2 (4.0~12.5) 3.12/3.27 3.21/3.43 A/B Hi:34 Me:31 Lo:28 49 Hi:13 Me:12 Lo:11 299x750x635 34 FDUM125VNPVD Twin FDUM60VD FDC125VN 12.5 (5.0~14.0) 14.0 (4.0~16.0) 4.47/4.51 2.80/3.10 C/D 5(24) Hi:34 Me:31 Lo:28 Cooling:50 Heating:51 Hi:16 Me:15 Lo:14 Hi:35 Me:32 Lo:29 51 Hi:13 Me:12 Lo:11 34 Hi:34 Me:31 Lo:28 49 Hi:20 Me:18 Lo:15 Cooling:75 Heating:73 299x950x635 40 Procure locally Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E 845x970x370 81 3.8(30) 9.52/15.88 50 30 15 -15~43*3 -20~20 FDUM140VNPVD FDUM71VD FDC140VN 14.0 (5.0~14.5) 16.0 (4.0~16.5) 50Hz:5.00/4.94 60Hz:5.00/4.80 50Hz:2.80/3.24 60Hz:2.80/3.33 C/C FDUM140VNTVD Triple FDUM50VD FDC140VN 14.0 (5.0~14.5) 16.0 (4.0~16.5) 50Hz:5.09/5.03 60Hz:5.09/4.89 50Hz:2.75/3.18 60Hz:2.75/3.27 50Hz:D/D 60Hz:D/C FDUM100VSPVD Twin FDUM50VD FDC100VS 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 10.0 (4.0~11.2) 11.2 (4.0~12.5) 3.12/3.27 3.21/3.43 A/B 5(15)

1Phase 220-240V 50Hz, 1Phase 220V 60Hz kW kW kW

Energy label Cooling/Heating Inrush current (Max. running current) A Indoor*2 Sound Ievel*1 dB(A) Outdoor Indoor*2 Air flow CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight kg(m) Ref.amount precharged Ref.piping size Liquid/Gas Ref.piping length m Vertical height O/U is higher m difference m O/U is lower Operating O/U Cooling temperature range Heating O/U

Range of Outdoor unit Indoor unit usage

299x750x635

83

Powerful-Hi can be selected. Sound level: 100VNPVD 35dB, 125VNPVD 38dB, 140VNPVD 38dB, 140VNTVD 35dB, 100VSPVD 35dB Air flow: 100VNPVD 14CMM, 125VNPVD 18CMM, 140VNPVD 23CMM, 140VNTVD 14CMM, 100VSPVD 14CMM

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.

Micro Inverter
FDUM140VSPVD FDUM200VSPVD FDUM250VSPVD FDUM140VSTVD FDUM200VSTVD Triple Twin Indoor name FDUM125VD FDUM50VD FDUM71VD FDUM60VD FDUM71VD FDUM100VD Outdoor name FDC250VS FDC140VS FDC200VS FDC125VS FDC140VS FDC200VS Power source 3Phase 380-415V 50Hz, 3Phase 380V 60Hz Nominal cooling capacity 14.0 25.0 20.0 14.0 20.0 12.5 ISO-T1(JIS) kW (5.0~14.5) (10.0~28.0) (7.0~22.4) (5.0~14.5) (7.0~22.4) (5.0~14.0) (Min~Max) Nominal heating capacity 16.0 28.0 22.4 16.0 22.4 14.0 ISO-T1(JIS) kW (4.0~16.5) (9.5~31.5) (7.6~25.0) (4.0~16.5) (7.6~25.0) (4.0~16.0) (Min~Max) 50Hz:5.09/5.03 50Hz:5.00/4.94 Power Consumption Cooling/Heating kW 6.86/6.72 9.31/8.35 6.88/6.74 4.47/4.51 60Hz:5.09/4.89 60Hz:5.00/4.80 50Hz:2.75/3.18 50Hz:2.80/3.24 COP Cooling/Heating 2.92/3.33 2.69/3.35 2.91/3.32 2.80/3.10 60Hz:2.75/3.27 60Hz:2.80/3.33 Energy label Cooling/Heating C/C D/C C/C 50Hz:D/D 60Hz:D/C C/C C/D Inrush current (Max. running current) 5(15) A 5(22) 5(19) 5(19) 5(15) Indoor*2 Hi:34 Me:31 Lo:28 Hi:35 Me:32 Lo:29 Hi:37 Me:35 Lo:32 Hi:38 Me:36 Lo:33 Hi:34 Me:31 Lo:28 Hi:35 Me:32 Lo:29 Sound Ievel*1 dB(A) Cooling:50 Heating:51 Outdoor 57 57 51 Cooling:57 Heating:58 51 Indoor*2 Hi:16 Me:15 Lo:14 Hi:20 Me:18 Lo:15 Hi:13 Me:12 Lo:11 Hi:20 Me:18 Lo:15 Hi:28 Me:25 Lo:22 Air flow CMM Cooling:75 Heating:73 Cooling:150 Heating:145 Cooling:150 Heating:145 Cooling:75 Heating:73 Outdoor 350x1,370x635 299x950x635 Exterior dimensions Height x Width x Depth mm 299x750x635 1,300x970x370 59 40 kg Net weight 34 122 Air filter, Q'ty Procure locally Remote control(option) Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E Exterior dimensions Height x Width x Depth mm 1,505x970x370 1,300x970x370 1,300x970x370 845x970x370 845x970x370 kg Net weight 140 122 122 83 83 kg(m) Ref.amount precharged 7.2(30) 5.4(30) 5.4(30) 3.8(30) 3.8(30) Ref.piping size Liquid/Gas 12.7/22.22 9.52/22.22 9.52/22.22 9.52/15.88 9.52/15.88 m 70 70 50 Ref.piping length 50 m Vertical height O/U is higher 30 m O/U is lower difference 15 Operating O/U Cooling -15~43*3 temperature range Heating -20~20 -20~20 -15~20 -15~20 O/U FDUM125VSPVD

Range of Outdoor unit Indoor unit usage

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static pressure of indoor units is 60Pa. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 125/140VSPVD 38dB, 200/250VSPVD 41dB, 140VSTVD 35dB, 200VSTVD 38dB Air flow: 125VSPVD 18CMM, 140VSPVD 23CMM, 200/250VSPVD 34CMM, 140VSTVD 14CMM, 200VSTVD 23CMM

31

MULTI [ INDOOR UNIT ]


CEILING SUSPENDED

FDEN
FDEN 40/50/60/71/100/125VD

CLASS

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.


FDEN71VNXPVD FDEN100VNXPVD Twin FDEN40VD FDEN50VD FDC71VNX FDC100VNX 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 7.1 10.0 (3.2~8.0) (4.0~11.2) 8.0 11.2 (3.6~9.0) (4.0~12.5) 1.98/2.40 3.02/3.18 3.59/3.33 3.31/3.52 A/C A/B 5(24) 5(17) Hi:39 Me:38 Lo:37 Cooling:51 Heating:48 Cooling:48 Heating:50 Hi:11 Me:9 Lo:7 Cooling:60 Heating:50 100 210x1,070x690 28 Pocket Plastic net x2 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-E1R 750X880(+88)X340 1,300x970x370 105 60 4.5(30) 2.95(30) 9.52/15.88 50 100 30 15 -15~43*3 -20~20

Wired remote control

Wireless remote control

RC-E4
(Option)

RCH-E3
(Option)

RCN-E1R
(Option)

Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) Power Consumption Cooling/Heating kW COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) A Indoor*2 Sound Ievel*1 dB(A) Outdoor Indoor*2 Air flow CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m difference O/U is lower Operating O/U Cooling temperature range Heating O/U

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.

FDEN125VNXPVD FDEN140VNXPVD FDEN140VNXTVD FDEN100VSXPVD FDEN125VSXPVD FDEN140VSXPVD FDEN140VSXTVD Twin Triple Twin Triple Indoor name FDEN71VD FDEN50VD FDEN50VD FDEN60VD FDEN71VD FDEN50VD FDEN60VD Outdoor name FDC140VNX FDC140VNX FDC100VSX FDC125VSX FDC140VSX FDC140VSX FDC125VNX Power source 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 1Phase 220-240V 50Hz, 1Phase 220V 60Hz Nominal cooling capacity 12.5 14.0 14.0 10.0 12.5 14.0 14.0 ISO-T1(JIS) kW (5.0~14.0) (5.0~16.0) (5.0~16.0) (4.0~11.2) (5.0~14.0) (5.0~16.0) (5.0~16.0) (Min~Max) Nominal heating capacity 14.0 16.0 16.0 11.2 14.0 16.0 16.0 ISO-T1(JIS) kW (4.0~17.0) (4.0~18.0) (4.0~18.0) (4.0~16.0) (4.0~18.0) (4.0~20.0) (4.0~20.0) (Min~Max) Power Consumption Cooling/Heating kW 3.86/3.70 4.78/4.43 4.72/4.38 3.02/3.18 3.86/3.70 4.78/4.43 4.72/4.38 COP Cooling/Heating 3.24/3.78 2.93/3.61 2.97/3.65 3.31/3.52 3.24/3.78 2.93/3.61 2.97/3.65 Energy label Cooling/Heating A/A C/A C/A A/B A/A C/A C/A Inrush current (Max. running current) 5(26) A 5(15) 2 Indoor* Hi:39 Me:38 Lo:37 Hi:39 Me:38 Lo:37 Hi:41 Me:39 Lo:38 Hi:41 Me:39 Lo:38 Sound Ievel*1 dB(A) Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling:49 Heating:52 Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling:49 Heating:52 49 Outdoor Indoor*2 Hi:18 Me:14 Lo:12 Hi:11 Me:9 Lo:7 Hi:18 Me:14 Lo:12 Hi:11 Me:9 Lo:7 Air flow CMM 100 Outdoor Exterior dimensions Height x Width x Depth mm 210x1,070x690 210x1,070x690 210x1,320x690 210x1,320x690 kg Net weight 28 28 37 37 Pocket Plastic net x2 (Washable) Air filter, Q'ty Wired:RC-E4, RCH-E3 Wireless:RCN-E1R Remote control(option) 1,300x970x370 Exterior dimensions Height x Width x Depth mm 105 kg Net weight 4.5(30) kg(m) Ref.amount precharged 9.52/15.88 Ref.piping size Liquid/Gas 100 m Ref.piping length 30 m Vertical height O/U is higher 15 m difference O/U is lower Operating -15~43*3 O/U Cooling temperature range Heating -20~20 O/U

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 71/100VNXPVD 46dB, 100VSXPVD 46dB, 125/140VNXPVD 50dB, 125/140VSXPVD 50dB, 140VNXTVD 46dB, 140VSXTVD 46dB Air flow: 71/100VNXPVD 13CMM, 100VSXPVD 13CMM, 125/140VNXPVD 22CMM, 125/140VSXPVD 22CMM, 140VNXTVD 13CMM, 140VSXTVD 13CMM

32

Range of Outdoor unit Indoor unit usage

Range of Outdoor unit Indoor unit usage

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) Sound Ievel Air flow *1 Indoor*2 Outdoor Indoor*2

The values are for simultaneous Multi operation.

Micro Inverter
FDEN100VNPVD FDEN50VD FDC100VN kW kW kW A dB(A) 10.0 (4.0~11.2) 11.2 (4.0~12.5) 3.12/3.28 3.21/3.41 A/B FDEN140VNTVD FDEN125VNPVD FDEN140VNPVD Twin Triple FDEN50VD FDEN71VD FDEN60VD FDC140VN FDC140VN FDC125VN 1Phase 220-240V 50Hz, 1Phase 220V 60Hz 14.0 12.5 14.0 (5.0~14.5) (5.0~14.0) (5.0~14.5) 16.0 14.0 16.0 (4.0~16.5) (4.0~16.0) (4.0~16.5) 4.88/4.58 4.23/3.83 4.87/4.59 2.87/3.49 2.96/3.66 2.87/3.49 C/B C/A C/B 5(24) Hi:41 Me:39 Lo:38 Cooling:50 Heating:51 Hi:18 Me:14 Lo:12 51 FDEN100VSPVD Twin FDEN125VSPVD FDEN50VD FDEN60VD FDC100VS FDC125VS 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 10.0 12.5 (4.0~11.2) (5.0~14.0) 11.2 14.0 (4.0~12.5) (4.0~16.0) 3.12/3.28 4.23/3.83 3.21/3.41 2.96/3.66 A/B C/A 5(15) Hi:41 Hi:39 Me:38 Lo:37 Me:39 Lo:38 49 Cooling:50 Heating:51 Hi:18 Hi:11 Me:9 Lo:7 Me:14 Lo:12 210x1,320x690 37

Hi:39 Me:38 Lo:37 49 Hi:11 Me:9 Lo:7 210x1,070x690 28

CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher O/U is lower m difference Cooling O/U Operating temperature range Heating O/U

Cooling:75 Heating:73 210x1,070x690 210x1,320x690 28 37 Pocket Plastic net x2 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-E1R 845x970x370 81 3.8(30) 9.52/15.88 50 30 15 -15~43*3 -20~20

Range of Outdoor unit Indoor unit usage

83

Powerful-Hi can be selected. Sound level: 100VNPVD 46dB, 125/140VNPVD 50dB, 140VNTVD 46dB, 100VSPVD 46dB, 125VSPVD 50dB Air flow: 100VNPVD 13CMM, 125/140VNPVD 22CMM, 140VNTVD 13CMM, 100VSPVD 13CMM, 125VSPVD 22CMM

SPECIFICATIONS
Set model name Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) (Min~Max) Nominal heating capacity ISO-T1(JIS) (Min~Max) Power Consumption Cooling/Heating COP Cooling/Heating Energy label Cooling/Heating Inrush current (Max. running current) Sound Ievel Air flow *1 Indoor*2 Outdoor Indoor*2

The values are for simultaneous Multi operation.

Micro Inverter
FDEN140VSPVD FDEN200VSPVD FDEN250VSPVD FDEN140VSTVD FDEN200VSTVD FDEN200VSDVD FDEN250VSDVD Triple Twin Double Twin FDEN125VD FDEN50VD FDEN71VD FDEN50VD FDEN60VD FDEN100VD FDEN71VD FDC250VS FDC140VS FDC200VS FDC200VS FDC250VS FDC200VS FDC140VS 3Phase 380-415V 50Hz, 3Phase 380V 60Hz 25.0 25.0 14.0 20.0 20.0 14.0 20.0 (10.0~28.0) (10.0~28.0) (5.0~14.5) (7.0~22.4) (7.0~22.4) (5.0~14.5) (7.0~22.4) 28.0 28.0 16.0 22.4 22.4 16.0 22.4 (9.5~31.5) (9.5~31.5) (7.6~25.0) (4.0~16.5) (7.6~25.0) (4.0~16.5) (7.6~25.0) 9.01/8.05 9.50/8.69 4.87/4.59 6.47/5.97 4.88/4.58 6.40/5.90 7.43/7.26 2.77/3.48 2.63/3.22 3.09/3.75 2.87/3.49 2.87/3.49 3.13/3.80 2.69/3.09 D/B D/C C/B B/A C/B B/A D/D 5(19) 5(22) 5(22) 5(15) 5(19) 5(15) Hi:46 Hi:41 Hi:41 Hi:44 Hi:39 Hi:41 Hi:39 Me:44 Lo:43 Me:39 Lo:38 Me:39 Lo:38 Me:41 Lo:39 Me:38 Lo:37 Me:39 Lo:38 Me:38 Lo:37 57 51 57 51 Cooling:57 Heating:58 Cooling:57 Heating:58 Hi:18 Hi:26 Hi:11 Hi:29 Hi:18 Hi:18 Hi:11 Me:14 Lo:12 Me:23 Lo:21 Me:9 Lo:7 Me:26 Lo:23 Me:14 Lo:12 Me:14 Lo:12 Me:9 Lo:7 Cooling:75 Heating:73 Cooling:75 Heating:73 Cooling:150 Heating:145 Cooling:150 Heating:145 210x1,320x690 210x1,070x690 210x1,320x690 210x1,070x690 210x1,320x690 250x1,620x690 37 28 37 49 37 28 Pocket Plastic net x2 (Washable) Wired:RC-E4, RCH-E3 Wireless:RCN-E1R 1,300x970x370 845x970x370 1,300x970x370 1,505x970x370 845x970x370 1,505x970x370 122 83 140 140 122 83 5.4(30) 3.8(30) 7.2(30) 7.2(30) 5.4(30) 3.8(30) 9.52/22.22 9.52/15.88 12.7/22.2 12.7/22.22 9.52/22.22 9.52/15.88 50 70 70 50 30 15 -15~43*3 -20~20 -15~20 -20~20 -15~20

kW kW kW A dB(A)

CMM Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m difference O/U is lower O/U Cooling Operating O/U temperature range Heating

Range of Outdoor unit Indoor unit usage

The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 140VSPVD 50dB, 200VSPVD 46dB, 250VSPVD 50dB, 140VSTVD 46dB, 200VSTVD 50dB, 200VSDVD 46dB, 250VSDVD 50dB Air flow: 140VSPVD 22CMM, 200VSPVD 28CMM, 250VSPVD 32CMM, 140VSTVD 13CMM, 200VSTVD 22CMM, 200VSDVD 13CMM, 250VSDVD 22CMM

33

MULTI [ INDOOR UNIT ]


WALL MOUNTED

Only used with outdoor units of TWIN, TRIPLE, MULTI System.

SRK

CLASS

SRK 50/60ZJX-S

Wired remote control

RC-E4
(Option)

RCH-E3
(Option)

Point

1 Jet Air Scroll

We used the same aerodynamic analysis technology as used in developing jet engines.
CFD (computational fluid dynamics), used in blade shape design of jet engines, has been applied to the design of air channels in air conditioners to develop the ideal air channel system (air circulation). The airflow of the jets created in this system enable a large volume of air to be blown with minimum power consumption, yet the air flow is uniform, quiet and reaches points a long distance from the blower.
SC-BIKN-E SC-BIKN-E

RC-E4

Fast Slow Colors in the figure show the air speed.

Point

2 Long Reach Air Flow


61.5

Outline drawing (Unit:mm)


881.9 26 46.5 60 60 21 46.5 61.5

Powerful airflow is realized by Jet technology. Good for large living rooms and shops. Increase your comfort.
SRK50/60ZJX-S
(in cooling operation)

890

220

3 (right, left)61.5

Piping hole right

309 3.1

Terminal block

122.1

34

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.


SRK100VNXPZJX SRK125VNXPZJX SRK140VNXTZJX SRK100VSXPZJX SRK125VSXPZJX SRK140VSXTZJX

Twin

Triple

Twin

Triple

Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) kW Power Consumption Cooling/Heating Cooling/Heating COP Cooling/Heating Energy label A Inrush current (Max. running current) Cooling Indoor*2 1 Heating dB(A) Sound Ievel* Outdoor Cooling Indoor*2 Heating CMM Air flow Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight kg(m) Ref.amount precharged Ref.piping size Liquid/Gas m Ref.piping length m Vertical height O/U is higher m O/U is lower difference Cooling O/U Operating temperature range Heating O/U

SRK60ZJX-S SRK50ZJX-S SRK50ZJX-S SRK50ZJX-S SRK60ZJX-S SRK50ZJX-S FDC125VNX FDC100VSX FDC100VNX FDC140VNX FDC125VSX FDC140VSX 1Phase 220-240 50Hz, 1Phase 220V 60Hz 3Phase 380-415 50Hz, 3Phase 380V 60Hz 12.5 10.0 10.0 14.0 12.5 14.0 (5.0~14.0) (4.0~11.2) (4.0~11.2) (5.0~16.0) (5.0~14.0) (5.0~16.0) 14.0 11.2 11.2 16.0 14.0 16.0 (4.0~17.0) (4.0~16.0) (4.0~12.5) (4.0~18.0) (4.0~18.0) (4.0~20.0) 3.60/3.48 2.66/2.60 2.66/2.60 3.98/3.68 3.60/3.48 3.98/3.68 3.47/4.02 3.76/4.31 3.76/4.31 3.52/4.35 3.47/4.02 3.52/4.35 A/A A/A A/A A/A A/A A/A 5 (24) 5 (15) Hi:45 Me:38 Lo:26 Hi:47 Me:38 Lo:26 Hi:45 Me:38 Lo:26 Hi:45 Me:38 Lo:26 Hi:47 Me:38 Lo:26 Hi:45 Me:38 Lo:26 Hi:45 Me:38 Lo:32 Hi:45 Me:39 Lo:33 Hi:45 Me:38 Lo:32 Hi:45 Me:38 Lo:32 Hi:45 Me:39 Lo:33 Hi:45 Me:38 Lo:32 Cooling:48 Heating:50 Cooling:48 Heating:50 Cooling:49 Heating:52 Cooling:49 Heating:52 Hi:13.5 Me:11 Lo:8 Hi:14.5 Me:12.5 Lo:8.5 Hi:13.5 Me:11 Lo:8 Hi:13.5 Me:11 Lo:8 Hi:14.5 Me:12.5 Lo:8.5 Hi:13.5 Me:11 Lo:8 Hi:16.5 Me:14.5 Lo:10.5 Hi:17 Me:15 Lo:11 Hi:16.5 Me:14.5 Lo:10.5 Hi:16.5 Me:14.5 Lo:10.5 Hi:17 Me:15 Lo:11 Hi:16.5 Me:14.5 Lo:10.5 100 309x890x220 15 Polypropylene net x2 (Washable) Wired:RC-E4, RCH-E3 & Interface kit:SC-BIKN-E 1,300x970x370 105 4.5(30) 9.52/15.88 100 30 15 -15~43*3 -20~20

Range of Outdoor unit Indoor unit usage

SPECIFICATIONS
Set model name

The values are for simultaneous Multi operation.

Micro Inverter
SRK100VNPZJX SRK125VNPZJX SRK140VNTZJX SRK100VSPZJX SRK125VSPZJX SRK140VSTZJX

Twin

Triple

Twin

Triple

Indoor name Outdoor name Power source Nominal cooling capacity ISO-T1(JIS) kW (Min~Max) Nominal heating capacity ISO-T1(JIS) kW (Min~Max) Cooling/Heating kW Power Consumption Cooling/Heating COP Cooling/Heating Energy label A Inrush current (Max. running current) Cooling Indoor*2 Heating dB(A) Sound Ievel*1 Outdoor Cooling Indoor*2 Heating CMM Air flow Outdoor Exterior dimensions Height x Width x Depth mm kg Net weight Air filter, Q'ty Remote control(option) Exterior dimensions Height x Width x Depth mm kg Net weight kg(m) Ref.amount precharged Ref.piping size Liquid/Gas Ref.piping length m Vertical height O/U is higher m difference O/U is lower m Cooling O/U Operating temperature range Heating O/U

SRK50ZJX-S SRK50ZJX-S SRK60ZJX-S SRK60ZJX-S SRK50ZJX-S SRK50ZJX-S FDC100VS FDC140VN FDC125VN FDC125VS FDC140VS FDC100VN 3Phase 380-415 50Hz, 3Phase 380V 60Hz 1Phase 220-240 50Hz, 1Phase 220V 60Hz 10.0 14.0 12.5 12.5 14.0 10.0 (4.0~11.2) (5.0~14.5) (5.0~14.0) (5.0~14.0) (5.0~14.5) (4.0~11.2) 11.2 16.0 14.0 14.0 16.0 11.2 (4.0~12.5) (4.0~16.5) (4.0~16.0) (4.0~16.0) (4.0~16.5) (4.0~12.5) 2.72/2.86 4.53/4.05 4.25/4.29 4.25/4.29 4.53/4.05 2.72/2.86 3.62/3.92 3.09/3.95 2.94/3.26 2.94/3.26 3.09/3.95 3.62/3.92 A/A B/A C/C C/C B/A A/A 5 (24) 5 (15) Hi:45 Me:38 Lo:26 Hi:47 Me:38 Lo:26 Hi:45 Me:38 Lo:26 Hi:45 Me:38 Lo:26 Hi:47 Me:38 Lo:26 Hi:45 Me:38 Lo:26 Hi:45 Me:38 Lo:32 Hi:45 Me:39 Lo:33 Hi:45 Me:38 Lo:32 Hi:45 Me:38 Lo:32 Hi:45 Me:39 Lo:33 Hi:45 Me:38 Lo:32 51 51 Cooling:50,Heating:51 Cooling:50,Heating:51 49 49 Hi:13.5 Me:11 Lo:8 Hi:14.5 Me:12.5 Lo:8.5 Hi:13.5 Me:11 Lo:8 Hi:13.5 Me:11 Lo:8 Hi:14.5 Me:12.5 Lo:8.5 Hi:13.5 Me:11 Lo:8 Hi:16.5 Me:14.5 Lo:10.5 Hi:17 Me:15 Lo:11 Hi:16.5 Me:14.5 Lo:10.5 Hi:16.5 Me:14.5 Lo:10.5 Hi:17 Me:15 Lo:11 Hi:16.5 Me:14.5 Lo:10.5 Cooling:75,Heating:73 309x890x220 15 Polypropylene net x2 (Washable) Wired:RC-E4, RCH-E3 & Interface kit:SC-BIKN-E 845x970x370 81 83 3.8(30) 9.52/15.88 50 30 15 -15~43*3 -20~20

Range of Outdoor unit Indoor unit usage

The data are measured under the following conditions (ISO-T1). Cooling:Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating:Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 1 Indicates the value in *2 :: The values are for onean anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *3 : If a cooling operation isindoor unit operation. outdoor air temperature is 5C or lower, the outdoor unit should be installed at a place where it is not influenced by natural conducted when the * wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.

35

OUTDOOR UNIT (1.5-10.0HP)


NEW
FDC100VNX FDC100VSX (4.0HP) FDC125VNX FDC125VSX (5.0HP) FDC71VNX (3.0HP) FDC140VNX FDC140VSX (6.0HP)

SRC40ZIX-S SRC50ZIX-S* SRC60ZIX-S* (1.5HP~2.5HP)


units of *SRC50/60ZIX-S is common for both of outdoor and 1.5, SRK50/60ZJX-S (Residential Air-conditioners) 2, 2.5HP of Inverter Packaged Air-Conditioners. Common components make for easy inventory control and the installation procedure will be the same.

Blue Fin (3~10HP)


Due to application of blue coated fins (KS101) for the heat exchanger of new outdoor unit, corrosion resistance has been improved compared to current models.

Micro Inverter

Base heater kit (option)


FDC100VN FDC100VS FDC125VN FDC125VS FDC140VN FDC140VS (4.0HP~6.0HP) FDC200VS (8.0HP) FDC250VS (10.0HP)
This kit is recommended to be used in an area where the lowest temperature drops below 0C. CW-H-E applied for FDC100~250VN,VS FDC100~140VNX,VSX

Installation workability
Enhanced installation workability thanks to the extended pipe length longest level in the industry and pre-charged refrigerant.
Point

1 Piping length 100m (Hyper Inverter 4~6HP)

Refer to our Technical Manual in detail

Micro Inverter
Height difference
(Outdoor higher than Indoor)

Height difference
(Outdoor higher than Indoor)

Piping length
Piping length 30m 50m 100m Height difference 20m 30m 30m

Piping length

HP 1.5~2.5 3 4~6

HP 4~6 8.10

Piping length 50m 70m

Height difference 30m 30m

Point

2 Refrigerant precharged piping length extending to 30m

Refrigerant precharged piping length extends up to 30m. (1.5~2.5HP:15m) This eliminates the need to add refrigerant on site, which sets it free from trouble of excessive or insufficient charging of refrigerant, and allows carrying out the installation smoothly.

36

Control Systems [Individual control]


Remote Control line up
indoor unit wired all models remote control RC-E4 RCH-E3 wireless indoor unit FDT FDTC FDUM, FDU FDEN remote control RCN-T-36W-E RCN-TC-24W-ER RCN-KIT3-E RCN-E1R

Wired remote control with weekly timer (option)


RC-E4
Run hour meters to facilitate maintenance checking
RC-E4 stores operation data when an anomaly occurs and indicates the error on the LCD. It also displays cumulative operation hours of the air conditioner and compressor since commissioning.

The RC-E4 controller enables extensive access to service and maintenance technical data combined with easy to use functions and a clear LCD display.

Room temperature controlled by the remote control sensor


The temperature sensor is housed in the top section of the remote control unit. This arrangement has improved the sensitivity of the remote control units sensor, which permits more finely controlled air conditioning.

Weekly timer function as standard


RC-E4 provides (as a standard feature) a weekly timer, which allows oneweek operation schedules to be registered. A user can specify up to four times a day to start/stop the air conditioner. (Temperature setting is also possible with the timer).

Changeable set temperature ranges


RC-E4 allows the upper and lower limits of a set temperature range to be specified separately. By adjusting a set temperature range, you can ensure energy saving air conditioning by avoiding excessive cooling or heating. Changeable range Upper limit Lower limit 20~30C(effective for heating operation) 18~26C(effective for non-heating operation)

Timer operation

Simple remote control (option)


RCH-E3 (wired)
Considering specialized usage in hotel rooms, control buttons are limited only to minimum required functions such as ON/OFF, mode, temperature setting and fan speed. It is really simple and easy to use.
RCH-E3 is not applicable to the Individual flap control system and the Flap control system. When RCH-E3 is used, the fan has 3 speed settings (HiMe-Lo) only.

Up to 16 units
It can control up to 16 units individually, with pressing the AIR CON No. button.

AUTO restart
This function allows starting the air conditioner automatically when power supply is restored after power failure or by turning on the power switch.

Wireless remote control (option)


For wireless control simply insert the infrared receiver kit on a corner of the panel.

Thermistor (option)
SC-THB-E3
In case sensor in the indoor units or the remote control sensor can not sense the room temperature correctly, or individual remote control in each room is not required but only censor is required (as when center control system is in place), install SC-THB-E3 at proper place in the rooms.

RCN-T-36W-E, RCN-TC-24W-ER

RCN-KIT3-E

RCN-E1R

When wireless remote control is used, the fan has 3 speed settings (Hi-Me-Lo) only.

37

Control System
KX6 series

SUPERLINKSC-SL1N-E RAC series (SRK/SRF-ZJX-S)

SC-BIKN-E

SC-ADNA-E

SC-SL2NA-E

SC-ADNA-E

SC-ADNA-E

Central Control

SC-SL1N-E

SC-SL2NA-E

SC-SL3N-AE/BE

Start/stop control of up to 16 indoor units is possible either individually or collectively. With simple operations, you can effect centralized control.

Centralized control of up to 64 indoor units. It can allow connection with a weekly timer without using any interface.

Easy operation realized with a large color LCD and touch panel. Up to 128 indoor units can be controlled, when three SUPERLINK-2 systems are connected.

PC windows central control

BMS interface unit

SC-WGWNA-A/B
(SC-WGWNA-B is with electric power calculation function)

SC-BGWN-A/B
(SC-WGWN-B is with electric power calculation function)

(BACnet gateway)

(LonWorks gateway)

SC-LGWN-A

Up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) are controlled from the Internet Explorer.
Additional engineering service cost etc. is required. Please consult your dealer when using this central control.

Up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) are controlled centrally from a BMS.
Additional engineering service cost etc. is required. In case of SC-BGWN-B, communication test by qualified person regarding electric cost calculation function is required before commissioning. Please consult your dealer when using this gateway.

Up to 96 indoor units (48 indoor unit x 2) are linked as an open network! Centrally controlled through LonWorks!
Additional engineering service cost etc. is required. Please consult your dealer when using this gateway.

38

SUPERLINK E BOARD (SC-ADNA-E)


This board is used when conducting control of the single package (wired remote control unit) 1-type series using a network option (SC-SL1N-E, SC-SL2NA-E, etc).

(1) Functions
(a) Transmits the settings from the network option to the indoor units. (b) Returns the priority indoor unit data in response to a data request from the network option. (c) Inspects the error status of connected indoor units and transmits the inspection codes to the network option. (d) A maximum of 16 units can be controlled (if in the same operation mode).

(2) Wiring connection diagram


Connected to the terminals for Superlink signal lines MVVS 0.75 - 1.25mm2

SL E board

A B X Y

Blue Blue Black White

A B X Y

Run Abnormal
ON

OFF SW3

Master/Sub address

Basic Connections
Outdoor unit Internal/external Crossing Indoor unit X Y SL E Board X Y A B Network A B options Remote control X Y

Plural Controls by Multiple Remote Controls. Mixture of Multiple Units


Outdoor unit Internal/external Crossing Inside Inside Inside Inside Outdoor unit Internal/external Crossing Inside Inside Inside

SL E Board Network options

(3) Metal box dimension


85 40 22.5 5 35 30

100

90

2-6

70

LED2

LED3
SW1 SW2

Connected to the remote controller terminals (no polarity) (the length should be 600 m or shorter) 200 m or shorter 300 m or shorter 400 m or shorter 600 m or shorter 0.5 mm2 x 2 cores 0.75 mm2 x 2 cores 1.25 mm2 x 2 cores 2.0 mm2 x 2 cores

Network address setting switches [000]-(127)

Plural Controls by Multiple Remote Controls. Mixture of Multiple Units

Outdoor unit Internal/external Crossing Inside Inside Inside Inside

SL E Board Network options

Transmit the information of plural Master units to the network. Transmit the abnormalities of the Slave units to the network. Setting the plural Master/Slave units with the dip SW of the printed circuit board. Setting the Master/Slave remote controls with the dip SW of the remote control board.

Without Remote Control


Outdoor unit Internal/external Crossing Inside Inside

Wireless Kit
Outdoor unit Internal/external Crossing Inside Inside

SL E Board

SL E Board Network options

Set up 000 to 127 using address switch on the SL E board.

Set the SL E board dip SW to Master SW3-1 ON. The network option SLA-1E, SL1N-E is not allowed (This will disturb switching of the operation mode)

SL E Board Network options

Wireless Kit

Wireless remote control

39

OUTDOOR UNIT DIMENSIONS


FDC100VNX, 100VSX, 125VNX, 125VSX, 140VNX, 140VSX (unit:mm)
B A
46 51 46 113

Mark A B C D E F

Item Service valve connection of the attached connecting pipe(gas 15.88(5/8")(Flare) side) Service valve connection(liquid side) 9.52(3/8")(Flare) Pipe/cable draw-out hole 20x3places Drain discharge hole M10x4places Anchor bolt hole 30x2places(front) 45(side) Cable draw-out hole 50(back)

Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts. An anchor bolt must not protrude more than 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave 1m or more space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The model name label is attached on the lower right corner of the front panel. (7) Connect the Service valve with local pipe by using the pipe of the attachment. (Gas side only)

Terminal block

B A
1300

35

612

624

85

170

85

50

50

C
970

10

50

15

50

55

155

52 27 50

160

70

50 15 50

190 20 40 60 60

580

15

200 60

15

L2
Intake

L3

Intake

Examples of installation Dimensions

L4

38

L1
Service space Outlet

L1 L2 L3 L4

Open Open 500 300 5 Open 150 300 150 5 5 5

410

370

55

20

40

262

388

103

Minimum installation space

SRC40ZIX-S, 50ZIX-S, 60ZIX-S (unit:mm)

Terminal block

148.4

33.5

L2
640 Check joint

Intake

L3

L4
Service space

B
40

Intake outlet

42.5

L1

40

12.4

93

D
43.5 327.3

Examples of installation

24.3

50.6 12

Dimensions

L1 L2 L3 L4

Open 280 280 100 75 Open 100 80 80 250 Open 250

312.5

351.6

290

89

510 800

201

E
71.2

14.8

327.3

17.9

Mark A B D E

Item Refrigerant gas side pipe connection tap Refrigerant liquid side pipe connection tap Drain discharge port Anchor bolt hole

83.5

12.7(flare) 6.35(flare) 20.5x5places M10x4places

Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts.An anchor bolt must not protrude more than 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave a 1m or larger space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The unit name plate is attached on the lower right corner of the front panel.

40

FDC71VNX (unit:mm)

Mark A B C D E

Item Service valve connection (gas side) Service valve connection (liquid side) Pipe/cable draw-out hole Drain discharge hole Anchor bolt hole

15.88(5/8") (Flare) 9.52(3/8") (Flare) 20x3places M10x4places

223
2. R7 5

310

60 15

Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts. An anchor bolt must not protrude more the 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave 1m or more space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The model name label is attached on the lower right corner of the front.

47.5

L3

L2
340 380 418

Intake

L4
Service space

Intake

61

L1

61 150

D
580 880 150 88

27 32

19

outlet

Terminal block

Minimum installation space

C
750

B
30

48.5

30

Examples of installation

24

Dimensions

1 Open 300 100 250

2 Open 250 150 250

3 500 Open 100 250

103.5

A
165.5 25

L1 L2 L3 L4

FDC100VN, 125VN, 140VN 100VS, 125VS, 140VS (unit:mm)


Mark A B C D E F Item Refrigerant gas side pipe 15.88(flare) connection tap Refrigerant liquid side pipe 9.52(flare) connection tap Pipe/cable draw-out port 20.3x3places Drain discharge port Anchor bolt hole M10x4places 30.3x3places Cable draw-out port
Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts.An anchor bolt must not protrude more than 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave a 1m or larger space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The unit name plate is attached on the lower right corner of the front panel.

40

36

100

Terminal block

B A
845

51

A
F
195 110

110

195

242

279

150 52 27 50

10

50

50

55

50

70

C
970

40

50

15

15

50

VIEW A

E
190 60 40 20 60 580 200 60 15

L2
Intake

15

L3

Intake

Examples of installation

410

370

55

103

L4 L1
outlet Service space

Dimensions

38

L1 L2 L3 L4

Open Open 500 300 5 Open 150 300 150 5 5 5

C
20 40 262 388

Minimum installation space

41

OUTDOOR UNIT DIMENSIONS


FDC200VS (unit:mm)

FDC250VS (unit:mm)

42

MEMO

43

Before starting use


Heating performance
The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.

Refrigerant leakage
The refrigerant (R410A) used for Air conditioner is non-toxic and inflammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc.

Indication of sound values


The sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing.

Use in snowy areas


Take the following measures when installing the outdoor unit in snowy areas.

Snow prevention
Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit.

Use in oil atmosphere


Avoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break.

Snow piling
In areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit.

Automatic defrosting device


If the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The "Automatic defrosting device" will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again.

Use in acidic or alkaline atmosphere


If this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere.

Servicing the air-conditioner


After the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist.

Use in places with high ceilings


If the ceiling is high, install a circulator to improve the heat and air flow distribution when heating.

Safety Precautions
Air-conditioner usage target
The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur.

Installation
Always commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and fires. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base.

Usage place
Do not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, flow or accumulate, or places containing carbon fibers could lead to fires.

Before use

, Always read the "User s Manual" thoroughly before starting use.

Japan Head Office:

Mitsubishi Heavy Industries Ltd 16-5 2-Chome Kounan Minato-ku Tokyo 108-8215, Japan www.mhi.co.jp Our factories are ISO9001 and ISO14001 certified.
Certified ISO 9001 Certified ISO 14001

Certificate 04104 1998 0813 E5 BIWAJIMA PLANT MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO., LTD.
Certificate Number : 04100 1998 0813

Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certificate number : JQA-0709

Certificate Number : 5170-1996-AQ-RCG-RvA

Mitsubishi Heavy Industries-Haier (Quingdao) Air-conditioners Co.,Ltd.

Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certificate number : JQA-EM0256

BIWAJIMA PLANT

MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO.,LTD.


Certificate Number : 04104 1998 0813 E5

Mitsubishi Heavy Industries-Haier (Quingdao) Air-conditioners Co.,Ltd.


Certificate number : 01-1998-083

HB91-10P01E-A-0

February 2010(3B)R

Because of our policy of continuous improvement, we reserve right to make changes in all specifications without notice.

Printed in Japan

You might also like