You are on page 1of 22

VAPOUR ABSORPTION MACHINES

Presented by - Cooling Division C&H SBU - Thermax

Welcome to the home of Energy & Environment


We have tried to answer the following questions, so that, it would help you understand the product in a much easier way

Who are you and what do you do? What is Cooling and what are the conventional methods of cooling? How does an Electrical Chiller work? When should one go for an Absorption Chiller and how did a VAM evolve in Thermax? Why should one go for an Absorption Chiller? What are the governing principles of a VAM? How does an Absorption Machine work? Can you explain the whole scheme? What makes Thermax VAMs more unique and reliable? What do we offer and where we can/have offered? What do those Abbreviations mean? I have more queries, how can I get them cleared? How can we reach you? Who has certified us?

Who are you and what do you do?


Vision To be a globally respected high performance organization offering sustainable solution in energy and environment
Boilers & Heaters Absorption Cooling

Water & Waste Solutions

Chemicals

Cogeneration

Air Pollution Control

What is Cooling and what are the conventional methods of cooling?


Cooling Transfer of heat from source to sink by performing

an external work; even a body @ -272*C has one more degree of heat energy to be removed to achieve absolute zero (i.e.), 0*K (or) -273*C 1 TR = 3024KCal = 3.52KW = amount of energy absorbed by 1ton of ice, when it melts to water, at 0*C CONVENTIONAL METHODS OF COOLING: Natural Refrigeration

E.g., Clay water pot, Sweating

Mechanical Refrigeration Gas Refrigerators Vapour Refrigerators


Vapour Compression Vapour Absorption

How does an Electrical Chiller work?


Parts & Process involved: Evaporator - Refrigerant Vapourization Compressor - Refrigerant (Vapour Phase) Compression Condenser - Refrigerant ---> Vapour to Liquid Expansion Valve - Pressure Reducer / Throttling Valve To help refrigerant achieve the required Temperature

Working Cycle Vapour Compression Machine

Reefer Cycle.swf

When should one go for an Absorption Chiller and how did a VAM evolve in Thermax?
We would go for an Absorption Chiller:

When excess heat source is available, for e.g., availability of excess steam in a boiler When Heat is ineffectively dissipated into the atmosphere, for e.g., exhaust from a D.G, steam from a turbine outlet When the operational expenditure of VAM is very much lesser than the VCM, for e.g., when the industry is facing issues with power supply from the grid (high cost/frequent power cuts) When the production cost of steam is almost negligible, for e.g., In sugar plants, they have a co-gen power plant by using the baggasse (a by-product of the process)
92% + 1984-87 Marketing tie-up with Sanyo, Japan Market Share 1988-94 Technology collaboration with Sanyo, Japan in India 1991-96 - Direct Fired Technology tie-up Kawasaki Till Date Installed over 3000 Machines in over 50 Countries

Evolution of VAM technology in Thermax:

Why should one go for an Absorption Chiller?


We should go for an Absorption Chiller, because:

It is a simple Heat Exchanger operating at different pressures, hence, we can assure that it has an unmatched Reliability It has a very less operating and maintenance cost, along with an automatic and step-less modulation system It does not have any moving parts, hence, no noise, no vibration and no dynamic load (Roof-top positioning is possible) Waste heat is utilized usefully and in-turn, avoids the need for switching to a HT connection and also avoids a DG running especially for the chilling purpose (the load on EB power and DG is reduced to a huge extent) It operates on an environment friendly refrigerant (i.e.), CFC free, ozone friendly machine It is fully automated, hence, we require minimal amount of human intervention

What are the governing principles of a VAM?


Working Materials Thermax VAM

Refrigerant Salt Inhibitor Performance Booster

DM Water Lithium Bromide (LiBr) Lithium Molybdate (Moly) Octyl Alcohol

Boiling Point of Water is directly proportional to the

Vapour Pressure of the system


@atm. Pressure (760mm of Hg) Water boils @100*C In VAM, we maintain a shell pressure of 6mm of Hg, which facilitates the water to boil @3.7*C As we need to separate salt and water, it has to have a higher Vapour pressure difference, hence, we use LiBr as the salt solution The operating concentration of LiBr lies between 57-64% in Water

Hygroscopic nature of Salt


How does an Absorption Machine work?


Parts & Process involved:
Evaporator Refrigerant Vapourization Absorber Refrigerant (Vapour) Absorption by Absorbent Generator Regeneration of Refrigerant & Absorbent Condenser Liquefaction of Refrigerant Totally we have 2 Shells: Lower Shell Evaporator and Absorber Upper Shell Generator and Condenser

Condenser(Top Left Chamber) - Condensation of Refrigerant - Heat transfer to Cooling Water

Can you explain the whole scheme?

What makes Thermax VAMs more unique and reliable?


Step-less Modulation

- for a cooling load of 10 to 100%, the heat input can be


modulated without any drop in Efficiency

Crystallization free m/c - pro-active, anti-crystallization mechanism is provided

instead of a Reactive Auto de-crystallization mechanism using Online Concentration Control setup
Split Evaporator Design - twin-evaporator is provided to improve the COP of

the machine by 5% and capacity by 10%


SS 430 Ti Generator Tubes - straight; plain; Titanium stabilized; Ferritic;

Stainless Steel tubes in the HTG, to avoid the failure of generator tubes due to the presence of high temperature and concentration
Canned Motor Pumps - the impeller and the motor are packaged in a single

shell, bolted construction


Distributor Tray

- gravity feed mechanism is paired up with the distributor


tray (nozzle is avoided) for the spray system

What makes Thermax VAMs more unique and reliable?

Advanced Series Flow:


In a double effect machine, we split the flow of the dil. LiBr into two different paths. One line would flow through LTHE, HTHE and then flows to the HTG, whereas, the other line flows through the DHE and HR and mixes into the first line before reaching the HTG, in order to have a maximum utilization of the heat input. The LTHE gets heated by the incoming Abs. spray line, the HTHE gets heated by the Intermediate solution coming out of the HTG, the DHE gets heated by the Vapour coming out of the LTG and the HR gets heated by the steam coming out of the HTG. Thus, we can say that, Thermax VAMs have minimum amount of heat loss

Variable Flow Drive:


VFD modulates the frequency input to the Abs. Pump, based on the Generator level, which subsequently avoids 1) frequent ON/OFF of Abs. Pump reduction in heat exchanger life 2) excess heat input during part load conditions

What do we offer and where we can/have offered?


We offer,
Steam Fired VAM

50 to 3500TR Exhaust Fired VAM 50 to 3500TR Direct Fired VAM 50 to 3000TR Hot Water Fired VAM 50 to 1150TR

Combination of two or three heat sources are possible: COGENIE or TRIGENIE

We had offered to,


Breweries & Distilleries Chemical Industry Commercial Centers Dairy & Confectionary Educational Institutions Engineering & Electronic Industry Hotels & Hospitality Medical Centers Paper Plants Pharmaceuticals Power Plants Refineries & Petro-chemicals Steel Plants Super Markets & Malls

What do those Abbreviations mean?


Abs. COP *C DG HT HTG HTHE Kg/scm LTG LiBr LTHE m/c SS SCV TR VAM VCM Absorbent Co-efficient Of Performance degree Celsius Diesel Generator High Transmission High Temperature Generator High Temperature Heat Exchanger kilogram/square centimeter Low Temperature Generator Lithium Bromide Low Temperature Heat Exchanger machine Stainless Steel Steam Control Valve Tonnage of Refrigeration Vapour Absorption Machine Vapour Compression Machine

I have more queries, how can I get them cleared?


Thank you for your patient viewing & hearing

We hope that we have answered the questions which

may rise, when you think of an absorption machine. If you have any of the feasible scenarios for an absorption machine, we are always on your searchlist. We would be very much delighted to work in one- breath with you for a greener, energy efficient future For anymore queries, please feel free to contact the respective regional sales engineer or visit www.thermaxindia.com and post your query The contact details are given below

You might also like