You are on page 1of 16

Security Level:

Check Software Commissioning Quality

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

CONTENT
Software Quality Standard List Quality Checking

Software Quality Standard List


Item 1 Check ODU received power value whether match with the plan. Result

2
3 4 5 6 7 8 9 10

Check ODU TX power value whether match the plan


Check ODU TX and RX frequency whether match the plan Check IF working mode whether match the plan Check 1+1 configuration Check 1+1 switch state Check NE ID and name setting whether match the plan Check NE time whether synchronous with computer time Check NE synchronous clock configuration Check performance monitor state whether enabled

11

Check current and history alarm whether there are abnormal alarms

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 3

1. Check ODU received power value whether match with the plan.
The actual Rx Power value should within the plan designed receive value range according

to the customers requirement.


Plan Document

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 4

2. Check ODU TX power value whether match the plan.


The setting Tx Power value should equal to the plan designed transmit value.

The acceptable value: [25.5]

Plan Document

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 5

3. Check ODU TX and RX frequency whether match the plan.


The Tx Frequency and actual Tx Frequency should equal to the local site plan designed Tx

Frequency.

Plan Document

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 6

4. Check IF working mode whether match the plan.


The IF Mode should be the same as the plan document.

Plan Document

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 7

5. Check 1+1 configuration.


IF 1+1 configuration should correspond with the link design.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 8

6. Check 1+1 switch state.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 9

7. Check NE ID and name setting whether match the plan.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 10

8. Check NE time whether synchronous with computer time.


The NE currently time should be synchronous with your computer clock, and synchronous

mode is NM.

The Same

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 11

9. Check NE synchronous clock configuration.


For RTN 620/610, it is necessary to configure synchronous clock.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Page 12

9. Check NE synchronous clock configuration.


Typical mistakes:

5-IF

5-IF

RTN 620/610

RTN 620/610

Priority Priority

Internal 5-IF; Internal

Internal 5-IF; Internal

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 13

10. Check performance monitor state whether enabled.


Check on the setting of enabling performance monitor, which is required to be enabled.

State: Enable.
HUAWEI TECHNOLOGIES CO., LTD.

State: Enable.
Huawei Confidential

Page 14

11. Check current and history alarm whether there are abnormal alarms.
Browse current alarm, cant exist critical and abnormal alarm. Browse history alarm , cant exist critical and abnormal alarm during normal running time. For cant handle alarm, please save it and require help.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential