You are on page 1of 20

WG001201 MSOFTX3000 hardware data configuration

ISSUE 1.0

Wireless Curriculum Development Section

Review

This chapter describes the related concepts and

configuration process of MSOFTX3000 equipment


data, including the configuration of hardware basic information and board data.

2
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

References
MSOFTX3000 Operation Manual-Data Configuration

MSOFTX3000 Hardware Description Manual

3
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Course Contents

Chapter 1 overview

Chapter 2 hardware configuration

4
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

MSOFTX3000 data configuration procedure


Start Data preparation Internal data configuration Configuring hardware data Configuring local office information Configuring data of interface Configuring number analysis data Service data configuration Configuring mobile service data

End
5
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Data configuration Preparation

Command LOF SET CWSON: SWT=OFF SET FMT: STS=OFF LON SET CWSON: SWT=ON SET FMT: STS=ON FMT Power off, power on, and start loading To set offline

Description

To disable the alarm switch To disable the format conversion switch To set online To enable the alarm switch To enable the format conversion switch To format data

6
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Course Contents

Chapter 1 overview

Chapter 2 hardware configuration

7
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Chapter 2 the Chapter Name

2.1 Related Concepts 2.2 Configuration Procedures

8
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

MSOFTX3000 Cabinet
Integrated Configuration Cabinet Expansion Configuration Cabinet
Power distribution subrack (2U)

Expansion Configuration Cabinet


Power distribution subrack (2U)

Expansion subrack (9U)

Expansion subrack (9U)

Air deflector (2U)

Air deflector (2U)

Expansion subrack (9U)

Expansion subrack (9U)

Air deflector (2U)

Air deflector (2U)

Expansion subrack (9U)

Expansion subrack (9U)

Air deflector (2U)

Air deflector (2U)

Expansion subrack (9U)

Expansion subrack (9U)

Air deflector (2U)

Air deflector (2U)

9
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Equipment Numbering

Shelf number:0-2 Frame number:0-9

The service processing frame number is set by the DIP switch of the WSIU of the
frame. (off=1,on=0)

The basic frame is numbered 0 and other frames are numbered 1~9 in bottom-up order.

Switch Frame number 0 1 2 3 4 5 6 7 8 9

8 on on on on on on on on on on

7 on on on on on on on on on on

6 on on on on on on on on on on

5 on on on on on on on on on on

4 on on on on on on on on off off

3 on on on on off off off off on on

2 on on off off on on off off on on

1 on off on off on off on off on off

10
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Equipment Numbering

Slot number

W C S U Front
0

W W C C S C U U

W C C U

B
S G

W W S B M S G U

W S M U

W I F

W W C F D M B

W W W W C M M A D G G L B C C U

U P W R

U P W R

10

11

12

13

14

15 16

17

18

Back W W E W P P I I W S I U

W W W W W
H S

S H I S U C

B F I

B F I

W C K I

C
K I

U P W R

U P W R

11
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Equipment Numbering

Slot number

WSMU boards (and back-insert board WSIU) must be installed in slots 6 and 8.

WALU must be installed in front slot 16. WHSC must be installed in back slots 7 and 9, and blank filter

panels are configured in corresponding front slots.

Each UPWR board occupies two slots, and there are two front UPWR boards and two back UPWR boards. The slot numbers designated are 17 and 19 fixedly.

Other slots (0~5, 10~15) are installed with service processing


boards (including WCCU, WCSU, WBSG, WIFM, WAFM, WCDB, WVDB and WMGC).
12

Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Equipment Numbering

Module number

WSMU module number: 2~21 (allocated automatically by the

system)

WCCU/WCSU module number: 22~101 WCDB/WVDB module number: 102~131 WMGC/WAFM/WIFM/WBSG/WSGU module number: 132~211

13
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Chapter 2 the Chapter Name

2.1 Related Concepts 2.2 Configuration Procedures

14
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Procedures for configuring equipment data

Procedure Step 1: Add shelf Step 2: Add frame Step 3: Add board Step 4: Configure functions of WCDB board

Command ADD SHF ADD FRM ADD BRD ADD CDBFUNC

Step 5: Configure E1 port information of WEPI ADD EPICFG board

Step 6: Configure FE port information of WIFM board


Step 7: Clock configuration Step 8: Load equipment data

ADD FECFG
SET CKICFG ADD BOSRC

15
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Parameter relationship of commands for configuring equipment data


ADD SHF
[Shelf Number] [Location Title] [Position Number]

ADD FRM
[Shelf Number] [Frame Number] [Position Number]

ADD EPICFG
[EPI Frame Number] [EPI Slot Number]

ADD BRD
[Frame Number] [Slot Number] [Board Type] [Module Number]

ADD FECFG
[IFM Module Number] [IP Address]

ADD CDBFUNC
[CDP Module Number] [Function]

16
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Locking Clock Reference Source through E1

Procedure Step 1: Adding WEPI and WCKI Step 2: Configuring clock reference source Step 3: Configuring E1 information Step 4: Extracting clock reference data from WEPI ADD BRD

Command

SET CKICFG ADD EPICFG ADD BOSRC

17
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Locking Clock Reference Source through BITS

Procedure Step 1: Adding WEPI and WCKI Step 2: Configuring clock reference source Step 3: Configuring E1 information ADD BRD SET CKICFG ADD EPICFG

Command

18
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Summary

Master hardware data configuration steps

ADD SHF ADD FRM ADD BRD ADD CDBFUNC ADD EPICFG ADD FECFG Clock configuration

Master hardware data configuration method

19
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

20
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal