Central Control Room

Location
• Central control station room is
located on the Ground floor of the
mall with a door leading into the
parking lot.
• The room is accessible directly from
the basement.
• The central control station room is a
restricted area.
• Unauthorised entry is prohibited
• Entry only by showing of access card
What is Central Control
Room(CCR)?
• Central Control Room(CCR) functions
as a ‘Building Management System’
(BMS)
• It controls and monitors all utilities
and services present in the mall.
• It is predominantly handled by the IT
department of Inorbit Mall.
Building Management
System
• The Building Management system
consists of the following services :-
2.Closed Circuit Television (CCTV)
3. Public Access System (PAS)
4. Access Control Systems (ACS)
5. Fire Alarm System (FAS)
Closed Circuit Television
(CCTV)
• The monitoring Cameras are present
at
2.All entrances and exits
3.Elevators.
4.Elevator lobbies.
5. Corridors.
6. Exit Stairways.
7. Food court
Closed Circuit Television
(CCTV)
Public Address System

• All voice evacuation and public


address systems shall operate from
the Information Desk 1 (ID1) situated
near the CCR on the Ground floor.
• Manual control of evacuation tone
signals, alert tone signals, and voice
evacuation shall be provided on a
selective and all-call basis.
Public Address System
• Alert tones and voice instructions shall
be provided to the Amplifiers in the
following areas:
• Elevators.
• Elevator lobbies.
• Corridors.
• Exit Stairways.
• Individual shops
• Areas of rescue assistance
Access Control System
(ACS)
• The Access Control Systems monitors
the movement of people in the
restricted areas of the Mall
• This includes the Mall Office , Meter
Room , Central Control Room , Power
Room
• These areas can only be accessed by
authorized personnel with the help of
access cards.
• The entry and exit is recorded by this
Fire Alarm System (FAS)
• The Control Room consists of the Fire alarm Panel
• Alarm, supervisory and trouble signals shall be
annunciated in the central control station by means
of an audible and visual indicator.
• Inorbit Mall follows the Addressed System of Fire
detection
• In this system the exact location of the smoke can be
detected
• Here, the Fire Alarm Panel is connected to a electronic
flow chart which indicates the no. & position of the
smoke detector.
• Fire department communication system shall be
provided for fire department use.
• Fire detection System
 No. of Smoke detectors: 192 nos.
 Fire Extinguishers
 ABC Type: 112 nos.
Fire Alarm System (FAS)
• For the purpose of detection, zoning shall
be in accordance with the following:
 Each floor of a building shall be considered
as a separate zone.
 Each floor of a building is divided into two
separate zones
 Identification of the type of alarm,
initiation devices such as manual ,
automatic, sprinkler water flow, etc. shall
be separately indicated on electrically
supervised initiating circuits to the main
fire alarm control unit.
 Detection panels shall be graphic to
clearly indicate the layout of the building.
Other Components
 Building floor plans shall be permanently
mounted on an interior wall within the central
control station.

 Plans shall include the following:


• Stairways.
• Areas of rescue assistance.
• Shafts.
• Corridors.
• Elevators.
• Emergency generator and fuel locations.
• Fire pump.
• Smoke control supply and exhaust ducts.
• Mechanical rooms, gas, water, electrical, fire