Hicap Monitoring Process Flow

Private & Confidential

Hicap Monitoring Process Flow


NSN Project Team will send sms, email to EFlag Team about Hicap Implementation Plan including sites list and date of plan.

If NSN revise any ROC, EFlag Team need to revise soon.


EFlag Team preparing DT for Drive Test before Hicap Implementation. After Hicap Implementation, NSN Project Team will send sms about date and time of implemented sites.

EFlag Team need to collect KPI hourly, check alarm, parameter audit (consistencies check) and send report to NSN.

Private & Confidential

Hicap Monitoring Process Flow


EFlag Team also need to send rigger to site audit and make sure the hardware installer meets all the RNP requirement like antenna type, antenna height, azimuth and tilting, else we have to escalate to NSN with actual data in field. EFlag Team preparing DT for Drive Test after Hicap Implementation.

EFlag Team need to monitor and optimize the site until KPI meets the target and keep communicating with NSN for any information update and problem occurrence.
After KPI meets the target, EFlag Team can generate the final report to compare 5 days before and 5 days after Hicap Implementation including DT result statistic before and after to NSN and then Tsel.

Private & Confidential

Hicap Monitoring Process Flow


The example of the KPI & traffic before and after:
KPI BEFORE KPI DCR (%) HOSR (%) SDSR (%) TCH Block (%) KPI DCR (%) HOSR (%) SDSR (%) TCH Block (%) TRAFFIC Day 1 15-Aug-08
Traffic Carried (Erl.) BH Traffic After

Day 1 19-Jul-08 0.31 95.99 99.71 0.111 Day 1 15-Aug-08 0.22 98.34 99.73 0.02

Day 2 20-Jul-08 0.43 96.82 99.58 0.03 Day 2 16-Aug-08 0.54 97.64 99.7 0.00

Day 3 Day 4 21-Jul-08 22-Jul-08 0.29 0.22 95.97 97.63 99.73 99.74 0.02 0.03 AFTER Day 3 Day 4 17-Aug-08 18-Aug-08 0.21 0.49 98.14 97.45 99.75 99.53 0.06 0.19

Day 5 23-Jul-08 0.25 97.06 99.74 0.19 Day 5 19-Aug-08 0.23 98.00 99.77 0.16

Average 0.30 96.69 99.70 0.077 Average 0.34 97.91 99.70 0.086

0.08 0.72 0.07 0.07

Result Before Implementation 0.38 95.98 99.63 0.15 PASSED Y Y Y Y

Day 2 16-Aug-08 42.71 5 TRX =

Day 3 17-Aug-08 56.12 34 TS =

Day 4 18-Aug-08 56.56

Day 5 19-Aug-08 60.96

Average 54.60

PASSED Y

56.64

By using Erl-B Table (N, GOS 5%) :

28.70 Erlang

Private & Confidential

Hicap Monitoring Process Flow


The example of Drive Test Quality before and after:

Drive Test Statistic Threshold

Measurement RxLev (Idle) Before ( >= -85 dBm) RxLev (Idle) After ( >= -85 dBm )

Threshold 94.63% 92.48%

Passed (Y/N) Y Y

Private & Confidential

Hicap Monitoring Process Flow


The example of Idle mode, RxLevel (plot) Before:

Private & Confidential

Hicap Monitoring Process Flow


The example of Idle mode, RxLevel (plot) After: