You are on page 1of 78

www.huawei.

com
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
OptiX RTN 600 Configuration
Using the T2000 and T2000 Web LCT
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 1
Foreword
Huawei provides NE-level, subnet-level and network-level
management systems for the RTN 600 series products.
This course describes the NE-level management system OptiX
iManager T2000 Web LCT and the subnet-level management
system OptiX iManager T2000.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 2
Reference
Digital Microwave Communication
principles
OptiX iManager T2000 Management
System Solution V2.31
OptiX iManager T2000 Web LCT
Installation Guide and User Guide
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 3
Objectives
Upon completion of this course, you will be able to:
Describe the functions of the T2000 and the T2000 Web LCT.
Install the T2000 Web LCT.
Configure services and protection by using the T2000 and the
T2000 Web LCT.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 4
Contents
1. Introduction to Networks
Management Systems
2. Introduction to T2000 Web LCT
3. Introduction to the T2000

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 5
Comprehensive Management
System Solution
iManager T2000 iManager T2000
iManager T2100
OSS or integrated
NMS
MML MML MML
NE
management
layer
Network
management
layer
Service
management
layer
Qx Qx
NE layer
iManager T2100
iManager T2000
CORBA
iManager T2000
Integrated NMS & OSS
CORBA
CORBA
LCT
Qx
Qx
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 6
Introduction to Management Systems
The orientation of each management system is as follows:
iManager T2000 LCT
The T2000 local craft terminal (LCT) realizes the local maintenance and
equipment turn-up of Huawei OptiX products.
iManager T2000
The iManager T2000 (T2000 for short) is a subnet management system (SNMS)
for transport networks. The T2000 manages the full series of Huawei OptiX
products. The T2000 supports all functions of the NE layer and some of the
network layer management functions.
iManager T2100
The iManager T2100 (T2100 for short) is a network-level management system
that uniformly manages the full series of Huawei OptiX products. It manages
large-scale optical transport networks in a uniform manner.
iManager MDS
The iManager MDS (MDS for short) is a business-level management system for
transport networks. It assists users to plan and simulate an optical transport
network.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 7
Introduction to Management Systems
Platforms where the management systems are
running

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 8
Contents
1. Introduction to Management Systems
2. Introduction to the T2000 Web LCT
3. Introduction to the T2000

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 9
Contents



Introduction to the T2000
Web LCT
2.1 Main Characteristics
2.2 Application Scenario
2.3 Installation Guide
2.4 Connecting to NEs
2.5 Configuration Operations
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 10
T2000 Web LCT Main Characteristics
The characteristics of the T2000 Web LCT are as
follows:
Web-based solution
Per-NE configuration and maintenance
Access to a local NE through a LAN/RS 232
Access to a remote NE through DCC
Management of NEs of various types
Concurrent login to a maximum of 32 NEs
Integration with the T2000, T2100 or third-
party management system

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 11
T2000 Web LCT Function
The T2000 Web LCT provides the following NE-layer management functions:
Service configuration (including PDH and SDH microwave services)
Protection configuration (intermediate frequency protection, SNCP,
LMSP)
Setting and query of the intermediate frequency attributes
Setting and query of the radio frequency attributes
Data services (the 10M/100M fast Ethernet transparent transmission
board EFT4 is supported)
Setting and viewing of alarms and performance data
Communication and security


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 12
Contents



Introduction to the T2000 Web LCT
2.1 Main Characteristics
2.2 Application Scenario
2.3 Installation Guide
2.4 Connecting to NEs
2.5 Configuration Operations
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 13
T2000 Web LCT Application Scenario
Stand-alone
The equipment maintenance personnel installs the
T2000 Web LCT on a PC.
The equipment maintenance personnel manages local
or remote NEs by using the T2000 Web LCT.


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 14
T2000 Web LCT Application Scenario
Integrated
The personnel at the network operations center install the EMS or NMS on a PC.
Install the T2000 Web LCT as a part of the EMS. The NMS need not be installed.
The personnel at the network operations center starts the T2000 Web LCT by
using the EMS or NMS client.
NE network
DCN
NMS
EMS
EMS
NE network
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 15
Contents



Introduction to the T2000 Web LCT
2.1 Main Characteristics
2.2 Application Scenario
2.3 Installation Guide
2.4 Connecting to NEs
2.5 Configuration Operations
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 16
T2000 Web LCT Installation Guide
Pre-installation
Configuration requirements
The T2000 Web LCT runs on the Windows operating system.
Hardware requirements
CPU: Pentium III 700 MHz or higher
RAM: 256 MB (recommended 512 MB or higher)
Monitor: 1024 x 768 resolution
Serial port: RS 232
Ethernet port: 10M/100M
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 17
T2000 Web LCT Installation Guide
Pre-installation (continued)
Software requirements
Windows XP Professional SP2/Windows 2003
Server Standard SP1
Internet Explorer 6.0 or better
Tomcat 5.0
JDK1.4.2
Servlet 2.3



Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 18
T2000 Web LCT Installation Guide
Prerequisite: Windows XP Professional SP2 or Windows 2003 Server
standard SP1 must be installed.
Procedure
Step 1 Uncompress the installation package or Insert the installation CD-
ROM, and run the setup.exe file. Click Next.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 19
T2000 Web LCT Installation Guide
Step 2 Select I accept the terms of the license agreement and click Next.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 20
T2000 Web LCT Installation Guide
Step 3 Enter your user name, company name, and serial
number Click Next.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 21
T2000 Web LCT Installation Guide
Step 4 Click Next.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 22
T2000 Web LCT Installation Guide
Step 5 Click Install and the Setup Status dialog box is displayed. After the
T2000 Web LCT is installed, the Installation Complete dialog box is displayed.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 23
T2000 Web LCT Installation Guide
Step 6 Click Finish.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 24
T2000 Web LCT Installation Guide
Checking the Installation
After you install the T2000 Web LCT, you need to check the
correctness of installation. Check directories and files as follows:
The T2000 Web LCT installation directory.
By default is C:\Web_LCT.
The installation directory of the jre software.
By default is C:\Web_LCT\jre.
The installation directory of the Tomcat software.
By default is C:\Web_LCT\Tomcat .
Check the shortcut icon on desktop. The iManager T2000 Web LCT group
is created in the Windows Program bar.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 25
Contents



Introduction to the T2000
Web LCT
2.1 Main Characteristics
2.2 Application Scenario
2.3 Installation Guide
2.4 Connecting to NEs
2.5 Configuration Operations
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 26
T2000 Web LCT Connecting to NEs
To use the T2000 Web LCT to configure and manage NEs, you need to
connect the T2000 Web LCT to NEs with an Ethernet cable or a serial
port.
Procedure
By using a network cable
1. Connect a network cable to the computer where the T2000 Web
LCT resides.
2. Route the network cable to the equipment side and connect the
RJ-45 connector of the network cable to the network
management interface on the front panel of the equipment.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 27
T2000 Web LCT Connecting to NEs
Procedure (continued)
By using DCN
1. Use a network cable to connect the computer where the T2000
Web LCT resides to the DCN.
2. Connect one end of another network cable to the network
management interface on the front panel of the equipment.
Connect another end to the DCN.
By using an RS 232 serial port cable
1. Connect the serial port cable to the computer where the T2000
Web LCT resides.
2. Route the serial port cable to the equipment side. Connect the RS
232 connector of the serial port cable to the RS 232 interface on
the front panel of the equipment.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 28
Contents



Introduction to the T2000 Web
LCT
2.1 Main Characteristics
2.2 Application Scenario
2.3 Installation Guide
2.4 Connecting to NEs
2.5 Configuration Operations
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 29
Contents



Configuration Operations
2.5.1 Logging In to an NE
2.5.2 Modifying the NE ID
2.5.3 Configuring IF Protection
2.5.4 Setting IF Attributes
2.5.5 Setting RF Attributes
2.5.7 Configuring Service
2.5.7 Configuring SNCP Service
2.5.8 Converting service
2.5.9 Alarm
2.5.10 Performance
2.5.11 Communications and Security
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 30
Web LCT Configuration Logging In to an NE
Step1 Double-click the T2000 Web LCT shortcut icon on the desktop to launch the
T2000 Web LCT.
Step2 The User Login screen is displayed. Enter the user name and password. Click
Login.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 31
Web LCT Configuration Logging In to an NE
Step3 Create an NE in one of the following two ways.
1. Click NE Search and specify the search criteria. Select the NE to be added
to create a new NE.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 32
Web LCT Configuration Logging In to an NE
2. Create an NE directly. Click the Add NE and Enter the information
of the NE and create the NE.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 33
Web LCT Configuration Logging In to an NE
Step 4: In the NE List, select the target NE and click NE Login.Then, the IE
displays the NE Login dialog box.
Step 5:Enter the User Name and the Password. Then, click OK.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 34
Web LCT Configuration Modifying the NE ID
Step 1 In the NE Explorer, choose Configuration > NE Attribute from the
Function Tree. Click Modify NE ID.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 35
Web LCT Configuration Modifying the NE ID
Step 2 Enter a new ID and click OK.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 36
Web LCT Configuration Modifying the NE ID
Step 3 In the NE list, delete the original NE. Create a new NE with the new
ID.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 37
Web LCT Configuration Configuring IF Protection
The supported IF protection is 1+1 HSB, 1+1 SD, and 1+1 FD.
Create IF protection

Step 1 In the NE Explorer, choose Configuration > IF 1+1 Protection
from the Function Tree.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 38
Web LCT Configuration Configuring IF Protection
Step 2 Click New and enter the information of the IF protection. Click OK or
Apply.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 39
Web LCT Configuration Configuring IF Protection
Perform IF protection external switching. The priorities of external
switching commands are as follows: clear, lockout, force, and manual.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 40
Web LCT Configuration Setting IF Attributes
You can set the following IF attributes by using the T2000 Web LCT:
working mode, link ID, IF port loopback, 2 Mbit/s wayside service, and
ATPC-related information.
In the NE Explorer, select an IF board and choose IF Interface from the
Function Tree.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 41
Web LCT Configuration Setting IF Attributes
You can enable automatic transmit power control (ATPC), and adjust
the threshold and the ATPC adjustment.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 42
Web LCT Configuration Setting RF Attributes
By using the T2000 Web LCT, you can query and configure the following
RF attributes: transmit frequency, T/R spacing, transmitted power, ODU
manufacturer information, RF loopback status, and ODU status.
Frequency attributes
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 43
Web LCT Configuration Setting RF Attributes
Power attributes
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 44
Web LCT Configuration Setting RF Attributes
ODU manufacturer information
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 45
Web LCT Configuration Setting RF Attributes
In the Advanced Attributes tab, you set RF loopback and ODU status.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 46
Web LCT Configuration Configuring a Service
This operation is applicable to VC4, VC3, and VC12 services.
Procedure
Step 1 In the NE Explorer, Configuration -> Cross-Connection
Configuration from the Function Tree.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 47
Web LCT Configuration Configuring a Service
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 48
Web LCT Configuration Configuring a Service
Step 2 Click New, enter the information of a service and click OK or Apply.


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 49
Web LCT Configuration Configuring an SNCP Service
This operation is applicable to VC12, VC3, and VC4 SNCP services.
Procedure
Step 1 In the Cross-Connection Configuration window, click Create SNCP.
Enter the information of an SNCP service.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 50
Web LCT Configuration Configuring an SNCP Service

Step 2 After you create an SNCP service, the window is divided into two
panes. The upper pane displays the working service and the lower pane
displays the protection service. You can perform external switching for the
working and protection services.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 51
Web LCT Configuration Converting a Service
The T2000 Web LCT supports the conversion between a normal service
and an SNCP service.
To convert a normal service to an SNCP service, select a normal
service, right-click and choose Convert to SNCP from the shortcut
menu. Enter the source of the service in the protection channel and
click OK.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 52
Web LCT Configuration Converting a Service
You can convert the working or protection channel of an SNCP service to a
normal service.
To convert a working channel, right-click the service in the working channel
and choose SNCP Working Service Change to Normal Service from the
shortcut menu.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 53
Web LCT Configuration Converting a Service
To convert a protection channel, right-click the service in the protection channel
and choose SNCP Protection Service Change to Normal Service from the
shortcut menu.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 54
Web LCT Configuration Alarm
By using the T2000 Web LCT, you can view the current and history
alarms, the reporting status of alarms for an NE and boards, and
abnormal events.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 55
Web LCT Configuration Performance
The T2000 Web LCT supports 15-minute and 24-hour performance
monitoring intervals.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 56
You can view the current and history performance data, UAT events,
threshold crossings, and performance monitoring status. You can set the
performance threshold and reset a board registry.
Web LCT Configuration Performance
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 57
Web LCT Configuration Communications
The RTN 600 uses the OSP NE platform.
You can set multiple protocol stacks, including the OSI, IP, and
HWECC.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 58
Web LCT Configuration Communications
For DCC management, an IF board supports the configuration of
different DCC rates in different working modes.
When the working mode is PDH, the configuration of one-byte DCC
(D1-D1) rate is supported.
When the working mode is SDH, the configuration of D1-D3, D4-D12,
D1-D12, and D1-D1 is supported.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 59
Contents
1. Introduction to Management Systems
2. Introduction to T2000 Web LCT
3. Introduction to T2000

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 60
Contents
Introduction to T2000
3.1 Main Characteristics
3.2 Application Scenario
3.3 Configuration Operations
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 61
T2000 Main Characteristics
The T2000 consists of server and client.
The server is developed based on C++ and the client is based
on Java.
The T2000 manages a maximum of 1000 equivalent NEs and
supports concurrent operations of 32 clients.
T2000 server
T2000 client T2000 client
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 62
T2000 Main Characteristics
Modular architecture
Open and integrated
High efficiency and reliability
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 63
Contents
Introduction to T2000
3.1 Main Characteristics
3.2 Application Scenario
3.3 Configuration Operations
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 64
T2000 Application Scenario
Subnet management system (SNMS)
Applicable to small and medium network management
Provides power NE management functions
Uniformly manage the RTN/SDH/ASON/MSTP/WDM
equipment
Provides the standard northbound interfaces and supports
OSS integration
iManager T2000
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 65
Contents
Introduction to T2000
3.1 Main Characteristics
3.2 Application Scenario
3.3 Configuration Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 66
Contents
Configuration Operations
3.3.1 Microwave link
3.3.2 Alarm
3.3.3 Performance
3.3. 4 Linear MSP


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 67
T2000 Configuration Creating a Microwave
Link
The T2000 allows you to create a Microwave link. You can view the
networking on the Main Topology.
Step 1 On the Main Topology, right-click and choose Microwave link
from the shortcut menu. Enter the information of the Microwave link.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 68
T2000 Configuration Creating a Microwave
Link
Alternatively, click the icon on the toolbar to display the Create Link
window.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 69
T2000 Configuration Creating a Microwave Link
Step 2 Click OK or Apply. The link is displayed as follows:
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 70
T2000 Configuration Creating a Microwave Link

When the source and the sink have different working modes,
the link status is abnormal.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 71
Current Alarm Statistics
An NE reports current alarms to the T2000.
You can filter alarms according to the report time of
alarms.
You can view alarm statistics in each NE.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 72
Customizing Alarm Attributes
You can customize alarm functions, such as alarm severity, alarm
suppression, and alarm reporting.
The T2000 supports a maximum of 16 alarm templates.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 73
Alarm Correlation Analysis and Suppression
A number of NE alarms
Root alarm
Alarm analysis rule
Characteristics:
Retain the root alarms.
Suppress the non-root alarms.
Customize the analysis rules.
Suppress non-
root alarms
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 74
Customizing Performance Threshold
The T2000 supports customization of a maximum
of 16 performance thresholds.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 75
History Performance Analysis
The T2000 provides graphic history performance data analysis.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 76
T2000 Configuration
The T2000 and T2000 Web LCT are the same in terms of service
configuration, IF protection, IF and RF attributes, and communications.
Refer to the description in the T2000 Web LCT part.
www.huawei.com
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Thank You