1 Nokia Siemens Networks

R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
BSSPAR1: Chapter 1
Introduction to Parameter Planning
2 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
Legal Notice
Intellectual Property Rights

All copyrights and intellectual property rights for Nokia Siemens Networks training documentation, product documentation and
slide presentation material, all of which are forthwith known as Nokia Siemens Networks training material, are the exclusive
property of Nokia Siemens Networks . Nokia Siemens Networks owns the rights to copying, modification, translation, adaptation
or derivatives including any improvements or developments. Nokia Siemens Networks has the sole right to copy, distribute,
amend, modify, develop, license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material.

Individuals can use the Nokia Siemens Networks training material for their own personal self-development only, those same
individuals cannot subsequently pass on that same Intellectual Property to others without the prior written agreement of Nokia
Siemens Networks .

The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networks training session
for development of groups without the prior written agreement of Nokia Siemens Networks.

3 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
At the end of the module, the participant will be able to:
Sketch a BSS Managed Object Hierarchy
Look up the parameters at each level, in the parameter dictionary
Identify parameter value ranges and default settings
Find the changes to objects and parameters, that occur with each
BSS software release

Module Objectives
4 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
Managed Object Hierarchy
PLMN
BSC
LAPD RA
MALD MAL BAL DAP BCF PCM PCU
BTS2 BTS1
ADCW TRX HOC ADCE POC
RTSL
SEG
5 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
Example from Parameter Dictionary
Parameter name Rxlev Access Min
Abbreviated name rxLevAccessMin
Managed object BTS
Multiplicity 1
Description
With this parameter you define the minimum power level an MS has to receive before it is allowed to
access the cell.
Additional information -
Range and step -110...-47 dBm, step 1 dBm
Formula for getting internal value internal_value = (gui_value + 110)
Default value -105 dBm
Default value notes -
Required on Creation optional
Related functions -
Modification Online
Modified -
Related parameters -
Parameter relationships -
Related options -
Related features -
Interfaces

RACApp <-> RAC
Planner <-> RAC
RAC <-> Optimizer
RAC <-> BSC
References

3GPP Reference: 44.018, 45.008
MML Commands EQG, EQO
MML Abbreviated Name RXP
MML Full Name rxlev access min
Segment Level Parameter true
File Based Provisioning supported true
6 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
PRFILE, FIFILE and PAFILE parameters
PRFILE (General Parameter File)
Standard features
Optional features
Interrogate with MML command ZWOS

FIFILE (Feature Information Control File)
Stores optional parameters from the PRFILE
Interrogate with MML command ZWOI


PAFILE (BSC Control Parameter File)
GSM-BSC parameters
GSM Timers
Interrogate with MML command ZEGO
7 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
Features & Activation status
ZWOS command
ZWOI command
8 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
GSM-BSC Parameters & Timers
ZEGO command
9 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
Viewing parameters
Using NetAct CM Editor
10 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
Viewing parameters
with MML Commands in BSC
ZEQO Output
11 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
Exporting parameters
Using NetAct CM Ops Manager
12 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
New objects & parameters
13 Nokia Siemens Networks
R 255
G 211
B 8
R 255
G 175
B 0
R 127
G 16
B 162
R 163
G 166
B 173
R 137
G 146
B 155
R 175
G 0
B 51
R 52
G 195
B 51
R 0
G 0
B 0
R 255
G 255
B 255
Primary colours: Supporting colours:
Call Phases (MOC case)
MS BTS BSC
AUTHENTICATION (SDCCH)
Phase 2 : MM signalling
CIPHERING MODE (SDCCH)
Phase 8 : Ciphering
TMSI REALLOCATION (SDCCH)
SETUP (SDCCH)
Phase 2 : MM signalling
CH. REQUEST (RACH)
IMMEDIATE ASSIGN(AGCH)
SERVICE REQUEST (SDCCH)
Phase 1 : Paging, initial MS
CH.RELEASE
Phase 4 : Release
ALERTING & CONNECT
(FACCH)
Phase 2 : MM signalling
CONN. ACK. and MEASUREMENT
Phase 15 : Conversation
DISCONNECT & RELEASE
(FACCH)
Phase 4 : Release
ASSIGNMENT (SDCCH-FACCH)
Phase 3 : Basic assignment
Signalling procedures are used during the 15 phases in a basic call
Certain parameters influence the setting up and the release of a call