You are on page 1of 74

Excel

Life Safety

Honeywell
XLS 80e
2 to 8 Loop Intelligent Control Panel

Excel
Life Safety

XLS80e
2 to 8 Loop Intelligent Control Panel

Excel
Life Safety

XLS80e
Intelligent Repeater Panel

Excel
Life Safety

XLS80e - Network

Peer-to-peer network
ArcNet based
Re-transmission and isolation between nodes
(1 km btw. nodes)
Error checking and correction
at each node
Message routing
Up to 100 network nodes
Up to 158,400 devices
Up to 25,500 zones
Up to 700A PSU
Network alarm response less than 10 seconds

Excel
Life Safety

Master/Slave or Peer to Peer

IONISATION
SENSOR

BREAK GLASS

MCP

CONTROL
RELAY MODULE

MCP

PRESS HERE

THERMAL
SENSOR

ISOLATOR
MODULE
DOOR
HOLDER

CONTROL
MODULE

ISOLATOR
MODULE

EXTERNALLY
POWERED
SOUNDER
CONVENTIONAL
DEVICES
BREAK GLASS

PHOTO
SENSOR

PRESS HERE

CONVENTIONAL
DETECTOR
INTERFACE
MODULE

BEAM
DETECTOR
DUCT
HOUSING
AND SENSOR

THERMAL
SENSOR

LOOP-POWERED
BASE SOUNDER

CONVENTIONAL ZONE

LOOP-POWERED
SOUNDER

Excel
Life Safety

Life Safety System Goals

Greater fire detection accuracy with


elimination of nuisance alarms
Faster response
Greater flexibility in alarm system
design and application
Lower installed cost
Lower operating and maintenance cost

Excel
Life Safety

Global Market Offering

Compliant with EN54

Large graphic LCD


Multi-lingual capability
Modular design
Site configurable
Application software flexibility

Excel
Life Safety

XLS80e Applications (1)

An advanced life safety system designed for large single site


and multi-site applications

Office towers
Airports
Hospitals
Universities
Manufacturing
complexes
Military bases
Government buildings

Excel
Life Safety

XLS80e Applications (2)

Retrofit and new construction


Medium to large multiple
building systems
Standalone systems
Networked systems

Excel
Life Safety

ID3000 Technical Advances

Modular design
Surface mount technology
Fully automated test equipment
User friendly interface
Peripheral options
Advanced software features
Easy programming
Multiple language options

10

Excel

Traditional Fire Alarm Functions

Life Safety

Smoke and fire detection


Sprinkler system supervision
Automatic and manual system operation

Added Value Options


Advanced detection products
Filtrex, Multi-criteria, loop powered sounders and beam
detectors
Enhanced loop interface board (E-LIB)
Active and passive repeaters
Graphic annunciator driver
11

Excel
Life Safety

Key Terms

Basic Equipment Kit


Extension Chassis Kit
LIB - Loop Interface Board
E-LIB - Enhanced Loop I/F Board
DTP - Dual Transmission Path Booster I/F Kit
PSU - Power Supply Unit
Node - A system panel in a network
LCD - Liquid Crystal Display
CBE - Control by Event Matrix
Mimic (Graphic Annuciator) Driver Kit

12

Excel
Life Safety

Hardware Overview

Excel

Modular Design

Life Safety

Basic Configuration

Installation/Commissioning Kit
Basic
Equipment Kit

Cover(s)

Extension Chassis
(if required)
Optional Expansion
Modules (if required)

Backbox(es)
Power Supply

14

Excel
Life Safety

Backbox

ID3000 Key Components

Power Supply
& Batteries

Basic Equipment Kit


& Extension Chassis

Covers

15

Excel
Life Safety

Modular Design

Modular design offers:


flexibility
ease of expansion
lower service cost

16

Excel

Basic Equipment Kit

Life Safety

Expansion Cards

Processor
PCB

Main
Chassis

Base Card

Display PCB

17

Excel

Basic Equipment Kit

Life Safety

Can be extended with:


Up to 3 Standard Loop Cards (LIB)
Up to 3 Enhanced Loop Cards (E-LIB)
One RS-232 Card
One RS-485 Card
One ID-Net Card (*)
Panel Printer

18

Excel

Basic Equipment Kit

Life Safety

19

Excel
Life Safety

BEK - Inputs & Outputs

Outputs:
A/B/C/D - Sounder or Relay programmable
Sounder - rated @ 1A/30V each
Dry contact relay - rated @ 1A/30V
Two can be programmed for German UE interface
Fault and Fire Relays
rated @ 1A/30V each
Auxiliary 26-28Vdc outputs 1 and 2
both rated @ 1A
Battery charger max. 8.6A (130Ah batteries)

20

Excel
Life Safety

BEK - Inputs & Outputs

Inputs:
Mains - 230Vac 15% 50/60 Hz
Two addressable loops - 500mA
Tamper switch input (VF dry contact)
Serial Ports:
RS232 Port 1
PC Programming, internal printer option
RS232 Port 2 (optional module)
RS485 Port (optional module)

21

Excel

Modular Design

Life Safety

Extension Chassis Options

Extension Chassis
with 64 Zone Display
Module Kit
(with or without Printer)

Double Extension Chassis


with 255 Zone Display
Module Kit

Extension Chassis
with PRN2000
Printer Module Kit

Extension Cover
Blanking Plate

22

Excel
Life Safety

Extended
Backbox

Extension Options

64/128 Zone LEDs


and Panel Printer

255 Zone LEDs External


Printer Support

23

Excel

Modular Design

Life Safety

Optional Expansion Modules

Printer
Module Kit

ID-Net
Network Card

Isolated RS232
Module Kit

Isolated RS485
Module Kit

Dual Loop
Module Kit

Enhanced Dual
Loop Module Kit

24

Excel

Standard LIB vs. E-LIB

Life Safety

E-LIB

LIB
Handles communication only
System CPU scans loops

In case of main CPU failure


all detection is lost

CPU always busy


Max. 512 devices per panel

Powerful microprocessor
Degrade mode

In case of main CPU failure the E-LIB will


still activate sounder circuits 1-4 and the
Fire Relay when an alarm is received from
the loop

CPU available for other tasks


Full device count on the
panel

25

Excel
Life Safety

Serial Communication

RS232 Option
Isolated port
Third party interface
External printer
UniNet (NION) connection
Pager interface
VDU for terminal emulation

RS485 Option
Isolated
Master/Slave network
Multi-drop
Repeaters
Graphic annunciators

26

Excel

Expansion Modules

Life Safety

27

Excel

Modular Design

Life Safety

Power Supply Selection

Power Supply Unit Kit


2.5 Amp

Remote Battery/Charger
Enclosure Kit

Universal PSU Kit


4.5A or 7.0A
(External enclosure
or deep boxes only)

PSU DTP
Booster Kit
(4.5 or 7.0A PSU only)

28

Excel

Power Supply Options

Life Safety

2.5A PSU
mounts on the
side of the
BEK

DTP Booster
mounts on the
side of the
BEK

4.5A PSU
mounts into the
deep (extended)
back box

7A PSU
mounts into
the external
charger/ battery
enclosure

29

Excel
Life Safety

PSU with Dual Transmission


Path Booster Kit

Temperature compensated battery charger


DTP required by EN54-4 for external PSU application
Maintains constant loop voltage over a wide range of mains and battery
voltages
Fault monitoring on the power supply, mains and the batteries
Inhibits charger in case of an alarm

30

Excel
Life Safety

Power Supply Options

PSU Size

Typical number
of loops

Available auxiliary
power (Total)

Battery Charger

2.5A

1A

1.9A max.
38Ah Batteries

4.5A

2A

2.7A max.
42Ah Batteries

7.0A

2A

8.6A max.
130Ah Batteries

7A PSU Status Indication LEDs


(for use in the Remote Enclosure)
31

Excel
Life Safety

Modular Design

Backbox Options

Flush Mounting Bezels

Standard
Back Box Kit

Backbox Extension Kit


(available in standard and deep)
Extended Back Box Kit
(available in standard and deep)

Double Extended Backbox Kit


(available in standard and deep)

32

Excel

Back-box Options

Life Safety

12Ah

Deep Boxes

Standard

17Ah

38Ah

Extended

17 Ah

Standard
depth

38Ah
78Ah

Double Extended

External Box

33

Excel
Life Safety

Modular Design

Cover/Door Kits

Security Door Kits


(available for main &
extension covers)
Main Cover Kit
(High Security option)

Extension Cover
Blanking Plate

Extension Cover Kit


(High Security option)
Double Extension Cover Kit

34

Excel
Life Safety

Cover Options

All covers are available in:


Black/Grey (standard) matching backbox and bezel
Red matching backbox and bezel
NEXTEL Grey - matching bezel
Stainless Steel- matching bezel

35

Excel

19 Rack Mounting Option

Life Safety

36

Excel

19 Rack Mounting Option

Life Safety

19 Rack Mounting Assembly for Basic Equipment Kit


6U x 19 Rack Mounting Assembly for 7A PSU
6U x 19 Rack Mounting Assembly
for 64 Zone LED Extension Chassis & Printer Kit
6U x 19 Rack Mounting Assembly for 256 Zone
LED Extension Chassis Kit
6U x 19 Rack Mounting Assembly for Printer
3U x 19 Rack Blank Cover with Mains Termination Kit
6U x 19 Rack Blank Cover with Mains Termination Kit
3U x 19 Rack Mounting Assembly for Mimic Driver Kit
6U x 19 Rack Blank Cover
3U x 19 Rack Blank Cover
All available in the standard black/grey colour

37

Excel
Life Safety

Take Your Pick!

38

Excel
Life Safety

User Interface

Excel
Life Safety

6 Line x 40
Character
Graphic LCD

Main
Control
Switches

System
Status
Indicators

Main User Interface

Numeric Data
Entry &
Enter/Cancel

Navigation
Keypad

Key switch
Access Level 2

40

Excel
Life Safety

Main User Interface

Fully EN54 compliant

Simple tabbed menu navigation

Prioritised event display


(Automatically displays highest priority event)
User in control/has choice
of what is displayed
Simple lights and switches for
common controls
Top level info displayed

41

Excel
Life Safety

Graphic Display

Large 240 x 64 pixel LCD


6 lines x40 characters

Short-cuts for test & disablement

Selection by direct addressing


Displays:
Time and Date
Active Point Count for each event
Event type, index and actions
Panel, Zone and Device descriptors

42

Excel
Life Safety

Graphic Display

System Information on Windows Style Tabbed Screens


43

Excel

Graphic Display

Life Safety

Highest
Priority

FIRE

PRE-A

EVENT TYPES AND


TAB DISPLAY PRIORITIES

FAULT

DISAB

TEST

EVAC

Lowest
Priority

AUX

USER

If there is insufficient room to display all 8 tabs, then the


lowest (on the right) are omitted.
44

Excel
Life Safety

Virtual Keyboard

Panel and Zone Text up to 32 Characters via Keyboard


to Navigate and to Select
45

Excel
Life Safety

Example - 3 Zones in Alarm:

Fire Alarm Display

2 Devices Alarmed in Zone 2


1 Device Alarmed in Zone 1

1 other zone in Alarm - Press Zones in Alarm to view others


Use Navigation keys 46 to scroll through zones and display other
devices, date/time of event and device % value, etc.
Short-cut key selects either device or zone disablement.

46

Excel
Life Safety

Pre-Alarm Display

PRE-ALM DISPLAY REQUIRED?????


FROM P21 OF OPERATING MANUAL
3 Zones are in Pre-Alarm with 4 events in the system
2 Pre-Alarms are currently in Zone 8.
Use to scroll through zones &for device selection.

47

Excel
Life Safety

Fault Display

3 Zones are in FAULT with 4 events in the system.


Use to scroll through zones and to display device, type,
value, etc.

48

Excel
Life Safety Disablement Display
Life Safety

Excel

142 Devices Disabled in 3 input zones. 12 devices are disabled in Zone 2


(all input devices).
No outputs are disabled. Use to scroll through zone list and to
see device details.

49

Excel
Life Safety

Main Control Switches

Activate 2nd
Silence &
Stage Delay
Re-start
(if in Day Mode)
Sounders
Silence
Panel
Override Delays
Panel
Reset
&
Buzzer
Operate Sounders

Show User Menu


Toggle User Menus
Toggle between Day
Accept Non-Fire
and Night Modes
Alarm
Disable Fire Relay
(German VdS
and Fire Output
Mode)
(if Configured)

Show Fire Info &


Scroll through Zones
in Fire
Accept Fire Alarm

50

Excel
Life Safety

System Status Indicators

Fire condition exists


Fault condition exists
Pre-Alarm condition exists
System/CPU failure
Sounder O/P fault or disabled
Fire relay disabled, or fire O/P
disabled/in fault
Fire relay or fire O/P is active

51

Excel
Life Safety

System Status Indicators - 2

One or more devices disabled


Test mode active (Walk-Test, etc.)
Mains or battery power OK
Day mode active (pushbutton
operated)
Programmed delays enabled
A Non-Fire (AUX) device activated
Spare for future features
Spare for future features

52

Excel
Life Safety

Navigation & Numeric Keys


Text Edit
Short-Cuts
Disable/Enable
Menu Select
Up (Next)
Left (Back)
Down (Previous)

Numeric
Data
Entry

Right (Forward)
Accept/
Accept Enter

Cancel/Escape

53

Excel
Life Safety

Zone Status Indicators

FIRE and FAULT/DISABLED/TEST


Indication
64 Zone LED Display Module
(Single Extension Chassis) Two
Variants: Zones 1 to 64 or Zones
65 to 128

255 Zone LED


Display Module
(Double Extension
Chassis)

54

Excel
Life Safety

Language Options

Easy translation/customisation
using Slide-In type text labels

55

Excel
Life Safety

Main Features

Approved to EN54 Parts 2 and 4


Degraded mode of operation
Enhanced LIB (parallel CPUs)
Support for:
Advanced detection devices (VIEW, HARSH,
MULTI)
Loop powered sounders (ABS4, IBS3, ANS4,
AWS3)
Loop powered beam detectors (LPB-500, LPB620)
Menu driven point/data access
Multi-level operator password control
Multiple language options
English, German, Spanish, Icelandic,
Dutch/French (*)

56

Excel
Life Safety

Key Functions

10 sensitivity levels for Fire & Pre-alarm


Adjustable alarm & fault verification delay
Two-stage alarm operation
Alarm silence/re-sound
Sound general alarm (Evacuate)
Day and Night modes
Fire output(s) inhibit
Internal and external printer options

57

Excel
Life Safety

Key Functions (continued)

Powerful Control-by-Event (CBE)


Auto-Learn or PC programming
Duplicate address detection
One-man Walk Test with counter
Output device test
Daily high test
2 pulse rates for outputs
Time of day functions

58

System Capacity
Stand-Alone

Excel
Life Safety

Up to 8 loops
198 (99+99) devices per loop
Up to 99 VIEW per loop
Up to 1584 devices
Up to 255 zones
Up to 7A PSU
Up to 31 repeaters
Graphic annunciators (Mimic)
Up to 512 LEDs per controller
600 event history log
59

Excel
Life Safety

System Capacity
Stand-Alone (continued)

Four sounder circuits (NACs)


rated @ 1A each
Two programmable as VF relays
rated @ 30Vdc/1A
Two 24Vdc auxiliary outputs
rated at 1A each
Two programmable inputs
SPDT Fault and Fire relays
rated @ 30Vdc/1A
Two loops as standard
One isolated RS232 port (optional)
One isolated RS485 port (optional)

60

Excel
Life Safety

System Capacity
Networked - I

Master/Slave network
Up to 32 network nodes
Maximum 8 panels
Remainder repeaters
and graphic annunciators
Up to 64 loops
Up to 12,672 devices
Up to 2040 zones
Up to 56A PSU
Max. RS485 bus length of 3000m
61

Excel
Life Safety

Master/Slave Network

Functionality supported across the network:

Reset
Silence/Re-sound
Mute
Evacuate
Point/Zone Isolate
Walk Test
Zone Event Broadcast
Control by Event (CBE)

62

Excel
Life Safety

Bldg.2

Bldg.1

Bldg.3

System Capacity
Networked - II

Peer-to-peer network
ArcNet based
Re-transmission and isolation between
nodes (1 km btw. nodes)
Error checking and correction
at each node
Message routing
Up to 100 network nodes
Up to 158,400 devices
Up to 25,500 zones
Up to 700A PSU
Network alarm response less than 10
seconds

Bldg.4

63

Excel
Life Safety

Off-Line Configuration Tool

Stand-alone and Master/Slave network


DOS based
Individual panel programming
Manual software authentication
Same format as ID1000 and ID2000
Minimum training required
No special hardware requirement
Windows based Loop & Battery Calculator tool
Peer-to-peer network
Windows based
System-wide programming

64

Excel
Life Safety

Off-Line Configuration Tool


Windows version

Windows 95/98/ME/NT4/2000 Operating Systems


Windows XP under consideration
Standard Windows editing features
(cut, copy, paste, etc)
On-line error checking
Easy report printouts
On-Line Help menu

65

Excel
Life Safety

On-Site Configuration

Multi-level password/key-switch access


Level 2: Code 1/Keyswitch - Panel controls & menus
Level 3: Code 2 - Level 2 + Configuration menus
Level 3A: Code 3 - Level 3 + Advanced Configuration
Panel settings
Auto-learn facility
Loop/Device configuration
Text Editor (Virtual keyboard)
Control matrix editor (512 lines)
Network configuration

66

Excel
Life Safety

User Menu

C o n f i g u r a t i o n (E n t e r L e v e l 3 P a
s s c o d e)

67

Excel
Life Safety

Easy-to-use Test Mode

FIRE
B REAK

GLAS S

PRESS

HERE

1 sec ON or
follow me

LED ON
for 5sec
Use to scroll through inputs currently under walk-test.
Either Tested or Not Tested is highlighted for that device.
Use to scroll through device descriptions.

68

Excel
Life Safety

User Menu - Examples

Lamp Test checks all panel LEDs, Buzzer, L.C.D. & Contrast
adjustment

69

Excel

User Menu - Examples

Life Safety

Lamp Test also displays Panel & LIB software versions

70

Excel
Life Safety

Configuration Menu

Level 3 Access
Configuration:

1: Loop Device Configuration (auto-learn)


2: Zone Text Editor
3: Panel Text Editor
4: Control Matrix Configuration (512 lines)
5: Network Configuration
6: Panel Settings

71

Excel
Life Safety

Configuration Menu - 2

Loop Device Configuration

72

Excel
Life Safety

Configuration Menu - 3

73

Excel
Life Safety

Configuration Menu - 4

Network Configuration

74