You are on page 1of 16

Survey

Glries Centro Comercial Barcelona


Telefonica

Survey
Building Plan
Macro locations
Existing Technical rooms (Telefonica's
Technical Room)
New antenna locations and according to
the new implementation
Recommendations

Building Plan for 2017

Building Plan for 2017

3 Levels where the changes will be made


Ground floor
L+1

Ground floor
L0

Lower level
floor L-1

Indoor Parking
Indoor parking levels L-4,L-3,L-2, will stay the same;
L-1 the indoor park will be transformed into stores.
L-1 will be closed and not open to the outdoor as it is
now.
Identified on the photo gallery:
/0035 & 0040- Entrance between
shopping corridor to the park
/0036 0039 Park to be transformed
into stores

Macro locations

Macro locations
We assumed that 3 Macro sites close to the shopping have at lease 1
or 2 sectors to the Shopping mall on 2G, 3G and LTE1800 (confirmed
by Jorges smartphone) and 1/2 sectors to the surroundings of the
shopping mall.
Identifying the outdoor macros, we made sure to inforce the indoor,
by locating antennas strategically on the entrance of the shopping
mall especially where was LoS to the macro sectors.
This will also guarantee handover between outdoor to indoor and
avoid interference from the macro network.

Existing Technical rooms (L-1)

Telefonicas
Technical room (+25sqm room)
Maintenance team
mention the room
is pretty full
existing passage to
shopping mall (L-1)
Small technical
room and passage
to the indoor L-1
floor.

Observe
Photo gallery
0017-0023
Observe
Photo gallery
0024/25 and
26

Antenna Locations
New Technical Rooms
(Assumption)
2017

Observations
Level L-3 was closed on the survey;
The parking coverage and antenna locations on L-3
& L-4 can be replicated according to (L-2), the
building structure is the same;
We suggest to consider Level L-2 as the main
technical room level to distribute to all RUs (L-2
stands in between the higher and lower levels).
The shopping owner confirmed that most of the
cables energy, data and telecom cables will be from
lower levels to the higher levels but wasnt able

to be specific.

L-1,L0, L+1 antennas only to be located on the


corridors and not inside the stores.

Technical Room & Ant Location L-2


083

082

080

084

079

099
09
7

076
085

098
077

087

092

086

090

089

115
113

09
6

093

088

091

095

094

114

102

Panel MIMO Indoor


LoS and location
Possible Technical Rooms and vertical
passages (Assumption)
Omni MIMO Indoor

105

111

112

110

106

103

Technical Room & Ant Locations


L-3 & L-4
Replicate the o antenna locations and
technical rooms according to level L-2.
Example of antenna locations between
levels on the underground parking
118/119/1
20

We proposed panel
Because of the
height between
levels on the
escalators >9m

Level L-3

Antenna Locations L-1

051

053

050

052
046

043

041

044

042
075

036
075
073
074

055

039/03
7
040

Movistar
Store

057
058 059
068

069

066
067

071

070
072

Antenna Locations L0
149/ 150

145/146/147/
148

Photos not
allowed to be
taken

142/143/1
44

152/153/1
51
141

Carrefour

136/137/1
38/139/14
0

Cinema
160/ 161

Outdoor MIMO ODP065R09J


Coffee Restaurantes.
Blind spot outdoor from

Antenna Locations L+1


183

176/177/178

Tec room

180/181/182

Orange
167/173/174/
175

Vodafone

163 166/170
-172

Starbuc
ks

Recommendations
L-4,L-3 and L-2 will also need 2G and 3G
coverage among the 4G upgrade, no
coverage underground.
Antenna models:

OMNI MIMO - IXD-360VH03NT


PANEL MIMO - IWH-090VR08NT
OUTDOOR - ODP-065R09J
Active DAS: Multi Operator - Comflex 20W,
due to the size, space limitations and MIMO
(2 x RU) , we suggest the 10W, probably
well need to add more units.