Alarm 7745_Channel failure rate above defined threshold

For internalconfidential
Company
use only for internal use only
1
Nokia Siemens Networks

Contents
Alarm Definition as per NED
Reasons for Alarm
Troubleshooting

For internalconfidential
Company
use only for internal use only
2
Nokia Siemens Networks

Alarm Definition as per NED :


7745

CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD

Meaning :
The rate of calls terminating in failure on a channel is above the threshold value set by
the operator. The alarm is used to supervise the functioning of traffic and signaling
channels, and to detect the possible faulty channels.
Parameters, with their default values, affecting the alarm:
ZEEN:TCHFR = TCH failure rate (20 %)
SCHFR = SDCCH failure rate (80 %)
PRDCFR = length of supervision period (60 min)
CS = channel seizure threshold value (10)
SMBNT = supervision start time (08-00) EMBNT = supervision end time (18-00)

For internalconfidential
Company
use only for internal use only
3
Nokia Siemens Networks

Supplementary information fields :

For internalconfidential
Company
use only for internal use only
4
Nokia Siemens Networks

HOW ALARM 7745 Works


This alarm is generated if the percentage of abnormally ended transactions on SDCCH or TCH
channels during a measurement period is greater than or equal to the alarm threshold defined by
the operator. However, the alarm is not generated again for a channel with an already active
alarm. There are separate alarm thresholds for the SDCCH and the TCH failure rates.
when a SDCCH/TCH is released with the following error causes, the lost call counter is
augmented.
Both SDCCHs and TCHs, release because of:

a channel activation failure

user actions

a BTS failure

an LAPD failure

a BSC signalling unit (BCSU) reset

Abis problems

A interface problems

a radio failure

a radio failure on an old channel during handover

a radio failure on a new channel during handover

For internalconfidential
Company
use only for internal use only
5
Nokia Siemens Networks

TCHs only, release because of:

a transcoder failure

a transcoder failure on an old channel during handover

a transcoder failure on a new channel during handover


The counter for lost calls during a measurement period is cleared at the end of each
measurement period.
The filtering of the alarm generation is achieved with a threshold value defined by the
operator for the number of channel seizure requests. The number of channel seizure
requests during a measurement period must be greater than or equal to the threshold
value for the alarm to be generated. Although the Channel failure rate exceeded
(SDCCH, TCH) supervision is channel-specific, only one alarm per TRX and channel
type is generated during one measurement period. In the alarm printout, more
specified information is given of the channel with the greatest failure rate.
The system cancels the alarm at the end of the first such measurement period during
which conditions for alarm generation are no longer met or in connection with user's
locking and unlocking commands .

For internalconfidential
Company
use only for internal use only
6
Nokia Siemens Networks

Reasons for Alarm


Hardware Issues:

BTS unit hardware failures (TRX, BB2F,WCxA,DVxA)

Crossed feeder cables.

Bad SMA cable , bad feeder quality or their improper connectivity.

RSSI values on the main and diversity paths are differing a lot.

RF Issues:

BCCH Frequency used in MAL list

Some segments in the network using same BCCH Frequency

Value of TSC parameter is same as BCC value

High Interference caused in the network

BSC/Network Issues:

LAPD message distribution problem due to unused (floating) TRX signaling links on the
BCSU concerned

Telecom links overloading the BCSU

Repeated Transmission Failures

For internalconfidential
Company
use only for internal use only
7
Nokia Siemens Networks

Troubleshooting
Adobe Acrobat
Document

The Troubleshooting document uses the Ultra site nomenclatures for e.g. WCxA.
The document is equally applicable to Flexi EDGE BTS.Note: Flexi Edge BTS does not
have BB2F unit.

For BSC/Network Issues refer the followings:

There are a number of BSC alarms and counters which may indicate that BSC
load is a problem.
Increase in counters 3005, 3038, 3039, 3040, 3041, 500627
(DAT files are needed to see these counters)
Alarms 1014, 2133, 2478, 2720, 3164
Alarms 2993 & 7745 may also be caused by BSC overload.
Check the Transmission Links for any jitters, slips and BER.