Professional Documents
Culture Documents
SITE CRITERIA
BASIC NEEDS
Water
Movement and Circulation
*water
Storm Drainage
*movement and circulation
*storm drainage
Solid &and
*solid Liquid
liquid Water Disposal
water disposal
*parks and playgrounds
*power
Parks and Playgrounds
Power
LAND ALLOCATION
UNDER PD 957
ND ALLOCATION
70% saleable
30% non-saleable
LAND ALLOCATION
UNDER BP 220
No fixed ratio between saleable and non-
no fixed ratio between saleable and non saleable portions
saleable portions
100below -3.5
101-120 -4
121-130 -5
131-140 -6
141-150 -7
150above -9
centrally
located
mandatory
for 1
hectare and
above
non-
alienable
CIRCULATION SYSTEM
BP 220
observe
hierarchy of
roads
consider
topography
consider
access and
safety
optimize
no.of lots but
enhance
community
interaction
BP 220
CIRCULATION SYSTEM
BP 220
min. of 2
for
asphalt
pavement
min. of 6
for
concrete
INTERIOR SUBDIVISIONS
BP 220
must secure
right-of-way
to nearest
public road
minimum
R.O.W.of
10meters
SUBDIVISION ENTRANCES
BP 220
maximum of
400m
provide 3-m
path walk or
alley for
blocks
exceeding
250m.
ALLEYS AND PATHWALKS
BP 220
to serve as
block
breakers
3-meter
ROW
maximum
length of
60meters
paved with
macadam
CUL-DE-SAC/TURNABOUTS
BP 220
CUL-DE-SAC/TURNABOUTS
BP 220
LOT PLANNING
BP 220 AND PD 957
MINIMUM
FRONTAGE
6m 8m
LOT AREAS
UNDER BP 220
LOT AREAS
UNDER PD 957
ROWHOUSE BP 220 PD 957
MINIMUM
FRONTAGE
4 m.
3.5 m.
MAXIMUM
UNITS PER
BLOCK OR 20 UNITS
CLUSTER
MAXIMUM
BLOCK
100m
LENGTH
LOT AREAS
UNDER BP 220
LOT AREAS
UNDER PD 957
BP 220 PD 957
Economic Socialized Open Medium-
Market- cost
MINIMUM
FLOOR 22sq.m 18sq.m 42sq.m. 30sq.m
AREAS
MINIMUM Front - 1.5m. Front - 3.0m.
SET BACKS
Side - 2.0m. Side - 2.0m.
Economic -
complete based
on specifications
Socialized - shell
house with doors
and windows to
enclose the unit
MINIMUM LEVEL OF COMPLETION
UNDER PD 957
Complete
House
BASIC NEEDS BP 220
WATER SUPPLY
connection to public water supply system or
independent water supply system at 150
liters/capita/day
potable and adequate
ground reservoir 25 meters from source of
pollution/contaminants
BASIC NEEDS BP 220
POWER SUPPLY
provide 1 streetlight per pole if poles are
spaced at 50meters
provide 1 at every other pole if poles are
spaced at less than 50 meters
BASIC NEEDS BP 220
SEWER
AND
communal or DRAINAGE SYSTEMS
individual
septic tank
conforming to
Sanitation Code
drainage system
shall be
concrete-lined
with load-
bearing cover
NON-RESIDENTIAL USE
BP 220
BASIC NEEDS PD 957
provision of
elevator
mandatory
for projects
above 5
storeys
APPROVED ALTERATIONS
CEILING HEIGHT
MEZZANINE