WAGO

GROUNDING SHIELDING
SYSTEM

Created by :
Leksono Mugi _ Indonesia
Shield Connecting System

Easy handling and a wide range of accessories for the WAGO shield
connecting system provides for user-tailored installation.

These magnetic fluxes can cause many different types of


errors (frequency converter, quicker load change, etc)

With its shield connecting system, WAGO offers a


comprehensive and very effective program for this. Both
the EMV and the nominal values given will be controlled
within the expected range. Installation at a later date is
also a simple process. The WAGO shield connecting
system is insulated and can also be used as a grounding
potentia
Shield Clamping Saddles (790 Series)

Shield clamping saddles are available in


different sizes up to a max. shield diameter
of 40 mm.

The spring material is part of the clamping


saddle, providing a good electrical
connection (the system also acts as a
partial strain relief). The spring element
integrated in the shield clamping saddle
compensates deformation and settling that
results from a connected shield.
791 Series Shield Clamps

WAGO offers a wide range of shield clamps


for connectable shield diameters from 1.5 up
to 24 mm. Shielding the connection of
conductors is made safe and easy!
Please note: Shield terminal blocks are not
suitable for connecting ground conductors.
Shield Clamping Saddles with a Spring (Series 790)

Boasting a unique latching mechanism, WAGO's spring-equipped


790 Series Shield Clamping Saddles feature exceptional usability
and the simplicity of force-free mounting.
Utilizing a spring solution, the shield clamping saddle is fastened
on the busbar at the precise pressure required for optimal contact
and shielding effect.
The spring also simultaneously compensates for any settling of
the cable, and the large shield connection area ensures good
discharge performance.
The shield clamping saddles are suitable for various mounting
options, e.g., 10 x 3 mm busbar, specialty slotted carrier rail and
mounting plate.
They are available for shield diameters ranging from 3 to 20 mm:
38 mm (790-208), 616 mm (790-216) and 620 mm (790-220).
For safety and convenience, all three variants can be clearly
labeled with marking strips or WMB markers.
GROUNDING

The ground conductor terminal blocks


have a contact foot in the bottom level,
automatically establishing direct contact
to the carrier rail.

They are available as 2-, 3- and 4-conductor


versions.
These terminal blocks cannot be
commoned with push-in type jumper bars!