Presentation

on
Radiography Testing

By
Abhishek A V
abhishek.agyarapu@gmail.com
Outline
Application, Pros & Cons
Principle/Source Generation
Exposing Time, Film & its Characteristics
Penetrameters / IQI
Type of Technique
Defects/Identification
Film Interpretation
Acceptance Criteria
Report Format
Safety Precaution
RT- Radiography Testing
Advantages & Disadvantages
S.No Advantages Disadvantages
1 Can be used to inspect virtually all Extensive operator training and skill
materials. required.
2 Detects surface and subsurface Depth of Discontinuity not Indicated
defects.
3 Permanent Test Report can be Access to both sides of the structure is
Obtained usually required.
4 Ability to inspect complex shapes, Orientation of the radiation beam to non-
Hidden areas and multi-layered volumetric defects is critical.
structures without disassembly.
5 Minimum part preparation is Relatively expensive equipment and
required. investment is required.
6 Technique standardized and Possible radiation hazard for personnel.
Reference standards available

Application:
o Pipe work
o Pressure vessels and boilers Note:
o Structural steel works Testing can be carried out upto 200 mm
o Ship building
Introduction to Radiography
o The radiation are of higher energy (shorter
wavelength) version of the electromagnetic waves
o Source X ray/ Gamma ray High Electrical Potential
o X-rays are produced by an x-ray generator
o Gamma radiation is the product of radioactive Electrons
atoms. + -

o X-rays and gamma rays can be characterized by


frequency, wavelength, and velocity. X-ray Generator
or Radioactive
Source Creates
Radiation

Radiation
Penetrate
the Sample

Exposure Recording Device


Principle Differential Absorption
Different parts of object will absorb the radiation differently depending
on thickness, density and the atomic no of the object

Thinner portion will absorb less radiation and


transmit more radiation on to film and hence
more black will be on film and vice-versa

X-ray film
The film darkness (density) will vary
with the amount of radiation reaching
the film through the test object.

= less exposure
Top view of developed film
= more exposure
Generation of Sources
Source Depends on Type of Material

Material Thickness

Location of Testing
Thickness , Energy , Penetration, Radiation Hazards

Electrically Generated form


X Ray Tube/Tube Heads
Requires Power Supply
Radiation Controllable
Less Hazardous

Generated by decay of unstable atoms


Source - Artificial Isotopes Iridium, Cobalt
Iridium Max Penetration -75 mm in steel
CobaltMax Penetration -200 mm in Steel
Applicable for Onsite
No Power Required
Radiation is Non Controllable
Isotopes can be replaced & periodic Inspection
More Hazardous
Penetration Level w.r.t Source w.r.t Exposure

Steel Aluminum

X rays are measured in KV


Gamma measured Rays in MeV

Medical Diagnostics 50 KV
Exposing Time
Depends on
o Material of the Object Steel/Al/Cu
o Material thickness
o Type of Film Slow/Medium/Fast
o Film Density
o Source to Film Distance SFD
o Source X Ray/Gamma Ray Intensity/Energy

How to find Exposure Time:


o Exposure Chart X Ray Only
o Exposure Scale Gamma Ray Onsite Application
o Exposure Formulae - Gamma Ray

Exposure Time Formulae


= Film Factor x 2 N x (SFD)2 x 60
RHM x S x (100)2
RHM = Roentgen Hour Meter
SFD = Source to Film Distance
N = Thickness /Half Value Thickness

Exposure Scale
Exposure Time for X Ray
Less straight forward because the wavelength and intensity are variable

Exposure for X Rays determined by


o By Exposure Charts
o By Reference to previous exposure records
o By Trial and error test shots
o By combination of above

Exposure Equivalent Chart Exposure Chart


Geometric Principle of Shadow
Sharpness of the shadow dividing line b/w areas of different density

Controlled by Controlled by

Note
Object Should be kept as close as touch/near to Film
Object to be kept parallel to film axis
Central ray of beam (Focal Spot) should be perpendicular to film axis
Geometric Unsharpness (Ug) Width b/w Umbra & Penumbra
Sharp Image Umbra
Unsharp Image Penumbra

To minimize penumbra
o Source size as small as possible
o SOD/FFD as large as possible
o OFD as small as possible

Ug= f x t /SOD
f focal point
t - thickness (for solid object)
SOD Source to Object Distance

Object Thickness / Ug
Below (50mm) = max. Ug. (0.50mm)
(50 - 75mm) = max. Ug. (0.75mm)
(75 - 100mm) = max. Ug. (1.00mm)
Above (100mm) = Ug (1.75mm)
Film Characteristics
Film Density - Degree of Blackening
Low Film/High Film Density
Measure by Densitometer
For X Rays :1.8 4; For Gamma rays : 2-4
Film Speed Film which gives exposing time
Exposing Time less Fast Film
Exposing time medium Medium Film
Exposing time Fast Slow Film
Film Sensitivity Ability to detect smallest flaw
Film Resolution Separation of close lying Defects Film type Material Thickness
Film Graininess Small Size- Slow Film Less Graininess Class I T < 0.5
Big Size- Fast Film More Graininess
Class II T >0.5 to T < 1.0
Film Contrast Degree of Shining
More Shining High Film Contrast Class III T >1
Less Shining Low Film Contrast
Film Characteristics Curve / Sensitometric Curve/Hunter & Driffield Curve
Density is plotted against log of exposure
Film Characteristics Curve / Sensitometric /Hunter & Driffield Curve
1. Position of Curve on Exposure axis gives information on film speed
2. Position of Straight line portion of curve against density axis gives density range with which
the film is at its optimal
3. Gradient of Curve gives information on films contrast

Films are classified into Type 1, Type II and Type III


Intensifying Screens
Film is sandwiched between intensifying screens
Three types a) Lead Screens
b) Fluorescent Screens
c) Flurometallic screens
Lead Intensifying Screens
o Front Screen shortens exposure time and improves quality by filtering backscatter
o Back screens act as filter only
o Screen thickness 0.02 mm to 0.15 mm

Fluorescent Screens
o Intensification twice of Lead Screen
o Cost effective

Flurometallic screens
o Front screen act as filter and intensifier
o Intensifying Action achieved by emitting light radiation and particulate radiation electrons
Film Processing

Types of Processing
1. Manual
2. Semi Automatic
3. Automatic
Stop Wash
Dev. Fix Dryer
Bath Running Water

o Developer - converts latent image into manifest image (10-12 Min- Agitate)
o Stop Bath Removes Excess Developer (10-15 Sec)
o Fixer -Clean the film of unexposed, undeveloped AgBr crystals, promotes archival quality (5 Min)
o Wash rid the film of residual chemicals
o Wetting the film to swell the emulsion
Note :For manual processing a floating thermometer, a timer and the time -temperature chart are
essential.
Penetrameters /Image Quality Indication
o To achieve a radiographic image with highest quality
o It provide a means of visually informing the film interpreter of the contrast
sensitivity and definition of the radiograph

Types of IQI Commonly Used


1. Wire Type
2. Step Hole Type
3. Plaque Hole Type (Step Hole Type)

1% Sensitivity Aerospace Application


2 % Sensitivity Industrial Application
SensitivityAbility to detect smallest flaw

Suppose, Object 8 mm Thickness


o IQI Thickness = 2 % (Object Thickness) = 2 % (8) = 0.16 mm
So, the minimum size of the discontinuity
o Unit of IQI Thickness = Thou (40 Thou =1 mm) that should be visible in the radiography film
is of 0.16mm
Placement of Penetrameters /IQI
o To be placed at worst location/Extreme edge of radiographic film
o To be placed at Source Side, in case use Film Side ~ DWSI/DWDI (Indicate Letter F)
o For Weld, Wire Type IQI to be kept across the weld
o For Weld, Plate & Hole, Step Wedge , parallel to weld 3mm away from weld edge
o When there is no accessibility , Block/shim to be used & IQI to be placed on it.
o Density of radiograph varies from location of IQI by more than -15%
to 30 % then another IQI is required
o For Circumferential weld in SWSI-Panaromic technique,
3 IQIs at 120o apart, 4 IQI at 90o apart
o Backing rings or strips and root penetration are not to be considered as part of the weld or
reinforcement thickness in selection of the IQI.
o The material of the IQI shall be of similar radiographic density to that of the material under
examination, i.e. use steel for steel, aluminium for aluminium, etc.,
Wire Type Penetrameters /IQI
o In Wire Type IQI, Four standards - ATSM, ISO, DIN, EN
o ASTM has four Sets- A, B,C,D & its wire identification
o All 6 wires are equally spaced and same height
o 4 alternative Sets for ASTM Standard available Selected by End User

Selection of Wire Type IQI as per ASTM E 747-97

Alternative Sets- ASTM


Plate Hole/Plaque Penetrameters /IQI
Different Sensitivity Level
XX- Thickness of IQI on thou
1-1T 2-2T 4-1T A - 4 T Hole
1-2T 2-2T 4-2T B 1 T Hole
1-4T 2-4T 4-4T C 2 T Hole

2-2T IQI normally used


2- % of thickness of Object
2T- Image to be seen on Film

Selection of Plate Hole IQI Can be differentiated by Notch


IQI Sensitivity
For the wire type IQI:
%Sensitivity = (Diameter of the smallest visible wire / Thickness of metal) * 100
For the step-hole IQI:
%Sensitivity = Diameter of the smallest visible hole / Thickness of metal * 100
For the plaque hole IQI, % of Sensitivity = square root of (AxB/2)
A is thickness of the smallest plaque image visible, expressed as a percentage of metal thickness
B is the diameter of the smallest hole visible, expressed as a percentage of metal thickness

Back Scatter Radiation


o A lead symbol B with minimum dimensions of 1/2 inch in height and 1/16
inch in thickness, shall be attached to the back of film holder to determine if
backscatter radiation is exposing the film.
o If a light image of the B appears on a darker background of the radiograph,
protection from backscatter is insufficient and the radiograph shall be considered
unacceptable.
Radiography Techniques

Selection of Technique based on

o Test Object material/thickness/configuration

o Weld/Casting/Forging/Assembled part

o Anticipate location and nature of discontinuities

o Critical and vulnerable locations

o Sensitivity level required

o Accessibility of Film
Radiography Techniques

Types of Techniques
Single wall Single Image (SWSI)
o Flat Surfaces/Plates/sheets/Large Pipe Joints (Dia> 8)
o Film Inside, Source Outside

Single Wall Single Image (SWSI) Panoramic


o Film Outside, Source Inside

Double Wall Single Image (DWSI)


o Film Outside, source outside (External Exposure), Dia of Pipe > 3inch

Double Wall Double Image (DWDI)


o Film Outside, source outside (Elliptical Exposure), Dia of Pipe <3inch
For Panaromic, Multiple films are used and films must be same type
One Inch film to be overlapped with other
Single Shot, No of IQI to be calculated
Double Wall Single Image Double Wall Double Image

SOD=Pipe Dia

SOD wrt Top wall 0


Source Outside, Film Outside Source Outside, Film Outside
Source Displacement Angle
= 360 /n where n is odd, n= no of shots Exposing Time will be double
= 180 /n where n is even Only 2 Shots required
(OD/ID > 1.4)x1.7 = XX shots
(OD/ID < 1.4) =2 shots Elliptical image will be observed
OD Outer Diameter, ID Inner Diameter
For Example
OD= 50mm, t=12.5, ID = 25 N=?
(OD/ID > 1.4)x1.7 =3.4 ~ 4 Shots
Reference Source - ASNT Section 5
Reference Source - ASNT Section 5
Defects
o Casting
o Welding
o Forging
o Rolling
o Assembly
o Faults occurred during Handling/ Film Processing
Type of Defects - Casting
Defect Shape Location Indication
Shrinkage Linear Surface/Internal Black Line
Hot Tears Linear Surface Black Line
Cold Shuts Linear Surface Black Line
Porosity Round Surface/Internal/Root Black Spot
Non Metallic/Metallic Round Surface/Internal Black/White Spot
Inclusions

Type of Defects - Welding

Defect Shape Location Indication


Lack of Penetration Linear Root Black Line
Lack of Sidewall Fusion Linear Internal Black Line
Porosity Round Surface/Internal/Root Black spot
Slag Inclusions Round Internal Black/White Spot
Defects in Welding

Four Pases in Weld


a) Root
b) Hand pass
c) Fill
d) Cap

Root Pass(Bottom side of Welded piece) Cap Pass (Top side of Welded piece)
Types of Defects
Defects in Welding
o Lack of Penetration
o Lack of Fusion
o Porosity Cluster Porosity
o Slag Inclusions
o Root Undercut
o Crown Undercut
o Mismatch
oInadequate Weld Reinforcement
o Excess Weld Reinforcement
o Cracks
o Weld Spatter
o Arc Strike
o Tungsten/Oxide Inclusions (In TIG Welding)
o Whiskers / Burn through ( In MIG Welding)
Defects in Welding
Defects in Welding
Defects in Welding
Types of Defects
Casting Defects Can be classified as
Filling related defect
oBlow Hole
oSand Burning
oSand Inclusion Cold Lap/Cold Shut
oMisrun
oGas Porosity
Shape related defect
oMismatch /Misrun
oDistortion/Wrap
oFlash
Thermal defect
oCrack/Tears
oShrinkage - Cavity/ Dendritic/Filamentary/Sponge
oSink Mark
Defect by appearance
oMetallic Projections
oCavities
oDiscontinuities
oIncomplete casting
oRat Tail/ Buckles
Defects in Casting

Sand Inclusions Porosity Cavity Shrinkage Dendrite Shrinkage

Cracks Slag Inclusion Core Shit Sponge Shrinkage


Types of Defects
Defects in Forging Process
oUnfilled Section
oCold Shut
oScale Pits
oDie Pits
oImproper Grain Flow

Defects in Parent Material


o Surface Irregularities Rust/weld spatter/notches/ grooves/ loose scale
o Surface Roughness
oPorosity
oInclusions Metallic/Non Metallic
oLaminations/High Hydrogen Content
Types of Defects
Faults Associated with Storage
o Light Fog Exposed to light while yet covered with interleaving paper
o Radiation Fog Exposed to X Rays or Gamma rays during storage

Faults Associated with Safelight


o Safelight Fog Higher capacity lamp used
Film has been allowed to stand under safelight Illumination too long period
White light is leaking from a slit in the safelight box

Faults Associated with Before Development


o Dirt Deposit on intensifying screens
o Dark Spots due to low density and Hugh density
o Water Spattered/Fixer Solution on film
Types of Defects
Faults Associated with Loading and Unloading

o Film Adhesion Cassette adhered to intensifying lead screens

o Static Marks - Contact, peeling of foreign matter bcoz of electricity

o Kink Marks Bents occurred during handling

Faults Associated with Post Development Process

o Uneven Fixing

o Uneven Drying
Radiographic Interpretation in Steel Casting

ASTM E 446 - Reference Radiographs for Steel Castings Up to (51 mm) in Thickness
ASTM E 186 - Reference Radiographs for Heavy-wall (51 mm- 114 mm)) Steel Castings
ASTM E 280 - Reference Radiographs for Heavy-walled (114 to 305 mm)) Steel Castings
MIL STD 1265 A Radiographic Inspection, Classification & Sound Requirements for Steel Castings
Classification of Classes:
Radiographic Interpretation in Steel Casting
Aluminium Casting Defects
ASTM E 155 - Reference Radiographs for Inspection of Al & Mg Castings
MIL STD 139 A Radiographic Inspection, Soundness Requirements for Al & Mg Castings

Classification of Classes:
Acceptance Criteria for Al & Mg
Copper base & Nickel Copper Castings
ASTM E 155 - Reference Radiographs for High Strength Copperbase & Nickel-Cu Alloy Castings
Film Identification

Each radiograph shall be identified through the use of lead markers(numbers and letters).

The identification shall be as specified by the client but should consist of :-

1. Project Identification

2. Component, Casting, Pressure Vessel or Piping identifications

3. Seams or welds identification

4. R for repair, R2, R3 etc. if more than one repair.

5. C for new weld following complete cut out

6. Date of radiography

7. Welders identification
Film Viewing
o Equipment used to view radiographs for interpretation shall have a variable light source
sufficient for the essential designated IQI wire to be visible for the specified density range
of 2.0 to 4.0 High intensity light sources shall have exhaust arrangements for cooling to
prevent film damage
o Light from the viewer not transmitted through the film shall be masked when viewing the
radiograph.
o Calibrated densitometers or step wedge films shall be used to assure film density
compliance

Film Interpretation
o Radiographs shall be interpreted by Level II or Level III personnel
o Acceptance level shall be as per relevant Standard / project code
Quality Of Radiographs
All radiographs shall be free from mechanical, chemical or other blemishes to the extent that

they do not mask and are not confused with the image of any discontinuity in the area of

interest of the object being radiographed. Such blemishes include

a) Fogging

b) Processing defects such as streaks, watermarks, or chemical stains

c) Scratches, finger marks, crimps, dirtiness, static marks, smudges or tears

d) False indications due to defective screens.


Radiographic Testing Acceptance Standard For Weld
As per ASME Sec VIII, Div. I

a) All Welded joints surfaces shall be sufficiently free from coarse ripples,grooves, overlaps
and abrupt ridges & valleys to permit proper interpretation of radiographic and the
required non-destructive examinations. If any Default found on Surface, the film shall be
compared to the actual weld surface for determination of acceptability.
b) Indications shown on the radiographies of welds and characterized as imperfections are
un-acceptable under the following condition:

1) Any indications characterized as a crack or zone of incomplete fusion or penetration.


2) Any other elongated indication at radiography, which has length greater than:
(a) 6mm for t up to 19mm
(b) 8 mm for t from 19mm to 57mm
(c) 19mm for t over 57mm
Where: t= thickness of weld excluding any allowable reinforcement.

3) Any group of aligned indications that have an aggregate length greater than t in a length
of 12t , except when the distance between the successive imperfections exceed 6L
where L is the length of the longest imperfection in the group.

4) Rounded indications in excess of that specified by the acceptance standards given in


ASME sec. VIII, DIV I, appendix 4 fig. 4-2 to 4-8
Defect Removal for Welding
Repair area shall be located on the weld line after evaluation & interpretation of radiograph
defects shall be removed by suitable method such as grinding, chipping or gouging (if permitted)
welding of the repair area shall meet the requirement of related WPS,PQR.

Certification And Personnel Qualification In Radiographic Testing.


Personnel performing radiography examination to this procedure shall be qualified and certified
by XXX Company also shall meet the requirements of ASNT-SNT-TC-1A-2001 EDITION at least
level II and on ASNT-SNT-TC-IA for code section I and sec VII div 2.
Film interpreter shall have level II as a minimum
Report Format (General Electric, US)
Checklist for Reviewing Radiographic Inspection
Precautions for Radiation Safety
o Shielded Enclosures and Exposure Devices are manufactured in compliance with
authorizations, appropriately surveyed and followed by quality objectives
o Personnel are trained and competent to operate the exposure devices safely
o Approved Operational procedures are to be followed
o Sources are sealed and leak free
o Source to be maintained in safe and secure condition at end of use or are
decommissioned properly
o Every personnel involved in radiography shall wear personal monitoring film badge.
o Radiation warning signs shall be posted at sufficient locations along the rope and
monitored by the technician.
o Fire and safety regulations of clients shall be adhered to at all times.
Measurement of radiation as per MIL HDBK 728
Used to monitor amount of radiation received by man
Measured in REM- Roentgen Equivalent Man

Pocket Dosimeter Wrist Watch Dosimeter


Computed Tomography
o Computed Tomography (CT) is a powerful non destructive evaluation (NDE) technique
for producing 2-D and 3-D cross-sectional images of an object from flat X-ray images.
o Characteristics of the internal structure of an object such as dimensions, shape,
internal defects, and density are readily available from CT images.
o The component is placed on a turntable stage , b/w radiation source and imaging system.
o The turntable and the imaging system are connected to a computer.
o The imaging system produces a 2-D shadowgraph image of the specimen just like a film
radiograph.

Schematic View of a CT system


Pressure Vessel Inspection
The failure of a pressure vessel can
result in the rapid release of a large
amount of energy. To protect against
this dangerous event, the tanks are
inspected using radiography testing.
Thank You