User Archives

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.1 Automation and Drives
Siemens AG 2000. All rights reserved.
Objectives

- Creating a User Archive

- Creating a Table View

- Creating a Form View

- Accessing a User Archive

- Data Transfer to a Controller

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.2 Automation and Drives
Siemens AG 2000. All rights reserved.
User Archives

Advantages of user archives for:


Recipes
Batch data
Production data
Data storage for data from the controller
Tool management


Access to user archives through:
Table window
Internal functions
API functions (described in the WinCC Help, among others)
ODBC / SQL
MS Query
Communication with the controller using tags
Communication with the controller using raw data

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.3 Automation and Drives
Siemens AG 2000. All rights reserved.
WinCC Help (System)
WinCC Help

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.4 Automation and Drives
Siemens AG 2000. All rights reserved.
Creating a User Archive
Toggle for Table window or Wizard enabling

Data window
Navigation window

Table window for


editing online data
records

Archive name: H1_Heating

H1
_Heater

_Actual

_Setpoint

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.5 Automation and Drives
Siemens AG 2000. All rights reserved.
Exporting/Importing a User Archive

Archive
Fields

Note:
You can copy Fields and
Archives with Ctrl+C, and
insert them with Ctrl+V

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.6 Automation and Drives
Siemens AG 2000. All rights reserved.
Table View of the User Archive Control
Switchover Read and Write
Create new
Change tags
record
current field Import/Export
Delete archives (.CSV) Define sort
record Scroll in table condition
Define filter
window
condition
Help

Floor/Room

Actual room temp.


Setpoint room temp.
LastUser

Last data record


change

Note: The ID number is an internal reference of the database. The numbering does
not have to be consecutive. It should not be used for selections.

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.7 Automation and Drives
Siemens AG 2000. All rights reserved.
Form View of the User Archive Control

Operation outside of the Control

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.8 Automation and Drives
Siemens AG 2000. All rights reserved.
Communication with the Controller using Tags,
Operator Controlled

Runtime

RT DB

Select

Interface tags

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.9 Automation and Drives
Siemens AG 2000. All rights reserved.
Communication with the Controller using Tags,
PLC Controlled
Runtime

RT DB

Control tags Interface tags

Are supplied by the controller

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.10 Automation and Drives
Siemens AG 2000. All rights reserved.
Sort

Runtime

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.11 Automation and Drives
Siemens AG 2000. All rights reserved.
Filter Condition

Runtime

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.12 Automation and Drives
Siemens AG 2000. All rights reserved.
Creating Views

Shortcut menu

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.13 Automation and Drives
Siemens AG 2000. All rights reserved.
Exercise 1: Creating an Archive

User Archive Editor

Creating an Archive

Creating Archive Fields

Editing Table Windows

Archive fields

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.14 Automation and Drives
Siemens AG 2000. All rights reserved.
Exercise 1: Integrating a Control

You can activate the editing mode for the form window by
pressing Ctrl+double-click!

Form window call

You can change the column width after you press Ctrl+double-click.

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.15 Automation and Drives
Siemens AG 2000. All rights reserved.
Exercise 1: Setting Control Parameters

Double-click

Note: Every time you make a change to the archive structure, you have to reselect the source (archive).

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.16 Automation and Drives
Siemens AG 2000. All rights reserved.
Exercise 2: Form View
Expanding the exercise picture with the form view of the
User Archive- Table Element

Switch over

Shortcut menu

Configuration

Runtime

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.17 Automation and Drives
Siemens AG 2000. All rights reserved.
Exercise 3: A Second User Archive
Expanding the exercise picture

Views Archives

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.18 Automation and Drives
Siemens AG 2000. All rights reserved.
Exercise 4: Views of the Two Databases
Expanding the exercise picture

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.19 Automation and Drives
Siemens AG 2000. All rights reserved.
Exercise 4: Integrating a Control

Double-click

for views

SIMATIC HMI Date: 06.10.2017


SITRAIN Training for
File: SWINCCS_07e.20 Automation and Drives
Siemens AG 2000. All rights reserved.