Professional Documents
Culture Documents
PROJECT DESCRIPTION
OBJECTIVE :
Provide a fully documented study to clean and disinfect 5 gallon PC
bottles
HOW :
Optimize current cleaning & disinfection (C&D) procedures.
Demonstrate superior performance of proposed C&D procedures.
Test and validate the selected procedures in practice.
Ecolab Confidential 1
Five Gallon study
PLAN
Ecolab Confidential 2
Five Gallon study
Cleaning tests : procedure
Ecolab Confidential 3
Five Gallon study
Cleaning tests : results
best score based on lowest chemical cost
Ecolab Confidential 4
Five Gallon study
Cleaning tests : results
best score based on lowest temperature
Ecolab Confidential 5
Five Gallon study
Cleaning tests : results
best score based on lowest contact time
Ecolab Confidential 6
Five Gallon study
Compatibility tests : cleaners & disinfectants
Ecolab Confidential 7
Five Gallon study
Compatibility tests : results
products concentration % temperature C compatibility
mip zentra 0.5 60 ++
mip CIP 0.5 60 ++
NaOH + st WT 0.5 + 0.2 40 ++
horolith PA 0.5 40 +
NaOH 1.5 60 0
liquid spearhead 1.5 60 ++
polybrite 1 60 ++
oxonia active 450 ppm PAA 40 ++
hypochloran 500 ppm Cl2 40 ++
Na-hypochlorite (13%) 500 ppm Cl2 40 ++
Vortexx 225 ppm PAA 40 ++
oxysan ZS 385 ppm PAA 40 ++
Ecolab Confidential 8
Five Gallon study
Mark 0 Mark ++
for hazing no change / blank
SHOULDER
CM-meeting NW - January 14th 2004
Ecolab Confidential 9
Five Gallon study
Microbiological tests
Contents
Ecolab Confidential 10
Five Gallon study
Ecolab Confidential 11
Five Gallon study
Temperature effect on the strains
Main comment : temperature alone is not efficient enough to kill all the cells
in a short time
cfu/ml: colony forming unit
Ecolab Confidential 12
Five Gallon study
Comparison of the efficacy of
Na-hypochlorite versus Hypochloran
T = 20 C P3-HYPOCHLORAN Sodium Hypochlorite
Hard Water 30 F SPECIAL (Raw material)
BACTERIA 100 ppm chlorine 100 ppm chlorine
MOULDS 30 sec. 1 min. 2 min. 30 sec. 1 min. 2 min.
P. aeruginosa 4,42 >5 >5 4,68 >5 >5
ATCC 15442
E. coli >5 >5 >5 >5 >5 >5
ATCC 10536
S. aureus >5 >5 >5 >5 >5 >5
ATCC 6538
E. hirae >5 >5 >5 >5 >5 >5
ATCC 10541
A.niger NR NR NR NR NR NR
ATCC 16404
Results expressed in log reduction
NR: no reduction
CM-meeting NW - January 14th 2004
Ecolab Confidential 13
Five Gallon study
Comparison of the efficacy of
Na-hypochlorite versus Hypochloran
T = 45C
P3-HYPOCHLORAN Sodium Hypochlorite
Hard Water 30 F SPECIAL (Raw material)
BACTERIA 100 ppm chlorine 100 ppm chlorine
MOULDS 30 sec. 1 min. 2 min. 30 sec. 1 min. 2 min.
P. aeruginosa 4,14 >5 >5 4,72 >5 >5
ATCC 15442
E. coli >5 >5 >5 >5 >5 >5
ATCC 10536
S. aureus >5 >5 >5 >5 >5 >5
ATCC 6538
E. hirae >5 >5 >5 >5 >5 >5
ATCC 10541
A.niger NR NR NR NR NR NR
ATCC 16404
Results expressed in log reduction
NR: no reduction
CM-meeting NW - January 14th 2004
Ecolab Confidential 14
Five Gallon study
Warning
The use of P3-hypochloran products can avoid these problems: they contain
sequestring agents
hard water
membrane structure stabilisation of Gram negative bacteria
stabiliser, pH buffer
Ecolab Confidential 15
Five Gallon study
Comparison of the efficacy of chlorine versus PAA
TEMPERATURE 20C
Ecolab Confidential 16
Five Gallon study
Comparison of the efficacy of chlorine versus PAA
TEMPERATURE 45C
Ecolab Confidential 17
Five Gallon study
TEMPERATURE 20C
Ecolab Confidential 18
Five Gallon study
TEMPERATURE 45C
Ecolab Confidential 19
Five Gallon study
CONCLUSION
at 20C and 30 sec., the results are better against P. aeruginosa with P3-oxonia active
at 45C, the results are similar but P3-oxonia active (PAA) is more effective against
adhered bacteria (cannot be appreciated in the suspension tests)
against moulds (A. niger), 2 minutes and 1 % P3-oxonia active at 45C are
necessary to achieve 4 log reduction
Ecolab Confidential 20
Five Gallon study
CONCLUSION
The association of disinfectant and temperature increases the efficacy and allows
a significant reduction of the contact time !
Ecolab Confidential 21
Five Gallon study
VORTEXX
P3-OXYSAN ZS
Ecolab Confidential 22
Five Gallon study
TEMPERATURE 45C
T VORTEXX P3-OXYSAN ZS
MOULD control 225 ppm PAA (0,5%) 225 ppm PAA (0,3%) 450 ppm PAA (0,5%)
1 min. 30 sec. 1 min. 30 sec. 1 min. 30 sec. 1 min.
NR : No Reduction
Results expressed in log reduction
Ecolab Confidential 23
Five Gallon study
Ecolab Confidential 24
Five Gallon study
Best practice
recommendation
before field test
Ecolab Confidential 26
Five Gallon study
Ecolab Confidential 27