Professional Documents
Culture Documents
8D Report
2D Customer Complaint : Problem Description & Lot details
NC statement:
NC description:
Electronic parts which were waiting for COC where kept in Under inspection area,
whereas the disposition was taken as rejection. NCMR procedure was not followed
for the product.
2
1D Team Approach
SanminaTeam
S/n Name of the Employees Dept Title
3
3D Containment Action
Rejected materials where identified with a IQA Rejected sticker and materials
moved to NCMR location.
NCMR
material
5
4D Root Cause : Simulation of Root Cause & results
NCMR procedure defined process for dealing with Product related specifications.
It didnt provide guidance for any non conformance which is observed related to
other specific requirements like COC, test reports etc.
Operator were following NCMR procedure for only Product related issues.
6
5D Corrective Action :
(Action To Prevent The Re-Occurrence)
Correction Action Implementation
Actual
Target
S/n Corrective Action Resp Closure Status
Date
date
1 NCMR Procedure (QPI-QC-025) S.Balaji 01.07.2013 01.07.2013 Closed
modified to define process for (SQA)
addressing Non conformities
related to specific requirements
other than product
requirements.
2 Operator trained to follow the S.Balaji 02.07.2013 02.07.2013 Closed
NCMR process for all non (SQA)
conformances (Violation of
both Product requirement &
Documentation requirements)
3 NCMR location identified for Palani 01.07.2013 01.07.2013 Closed
keeping all NC material (IQA)
identified at incoming stage for
electronics and mechanical
parts
8
9